Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMAL MASS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A NUMERICAL STUDY OF HEAT TRANSFER IN THE FUEL CELL OF A SOLID OXIDE FUEL CELL-COMBUSTOR

A Solid Oxide Fuel Cell-Combustor (SOFC-C) concept was proposed to address many challenges a traditional fuel cell-gas turbine hybrid system (FC-GT) will have in aerospace applications. By taking advantage of the temperature rise during compression and the combustion of anode off-gas, the SOFC-C eliminates the recuperating heat exchanger usually required for cathode flows, greatly reducing the size and weight (thermal mass) of the system. The fuel cell is one of the key parts of the SOFC-C, so it is desired to understand the heat transfer in the fuel cell. In present work, a computational fluid dynamic (CFD) model was developed to reveal the gas flow and heat transfer in the fuel cell of the SOFC-C. The model includes not only convection heat transfer, but also includes the radiation heat transfer. The modeling results help to optimize the SOFC-C design.

Zhang, Mingkan↗

Field Performance of Commercial Building Load Flexibility Using Model Predictive Control

Model Predictive Control (MPC) applied to buildings is starting to see some commercial adoption by companies. However, it is hard to estimate if relative energy cost savings are enough to justify the cost of MPC implementation with few reported demonstrations. In small commercial and residential buildings, a one size-fits-all solution can help reduce implementation costs, while in very large buildings or districts the potential energy cost savings magnitude can cover more tailored solutions. This estimation becomes harder for medium to large commercial buildings, where a one-size-fits-all solution cannot be adopted and potential energy cost savings might not be sufficient to cover a tailored solution. Therefore, value propositions in addition to energy efficiency alone can make MPC technology more attractive through additional energy cost savings. One such value proposition is load shifting in response to dynamic electricity prices. On this aspect, MPC is a key technology to unlock building thermal mass for energy flexibility in response to electric grid conditions. This study shows the experimental results of MPC control of an office building in Berkeley, where different dynamic electricity price profiles were used in the MPC objective function to shift the building load and to calculate hypothetical electricity costs. Results show potential 50% cost savings with respect to the existing controller with the dynamic price scenario.

Zanetti, Ettore↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tailoring Charge Transport and Magnetism in Complex Half-Heusler/Full-Heusler Nanocomposites (Final Report)

This project exploits (1) the facile co-crystallization of the half-Heusler (HH) and full-Heusler (FH) structures, (2) the high coherency and stability of the HH/FH interfaces, and (3) the solid-state inter-conversion between HH and FH structures through local atomic diffusion, to investigate, for selected compositions of the HH and FH phases, the effect of size, dimensionality, dispersion and volume fraction of FH nanostructures on the electronic, phonon and magnetic behavior of the resulting HH/FH nanocomposites. Our goal is to identify and control key material and growth parameters governing phase formation, microstructural evolution, and to understand the mechanism by which these changes of the internal structure modify the material’s performance. To elucidate the mechanism by which the FH nanostructures regulate electronic charge transport and induce ferromagnetism within non-magnetic and magnetic semiconducting HH matrices, suitable series of HH/0D-FH and HH/2D-FH nanocomposites will be fabricated using synthesis conditions suggested by theoretical calculations of the formation energy and stability of various FH phases (varying M) in HH matrices with known chemical composition. The structure of the HH/FH interfaces (size, chemical composition, volume fraction and dispersion) will be investigated along with the evaluation of the electronic (carrier density, mobility, thermopower, electrical conductivity, effective mass), thermal and magnetic (susceptibility, magnetization etc.) properties of the resulting HH/FH nanocomposites.

36 MATERIALS SCIENCE↗

Heating and Cooling Energy Modeling of 3D-Printed Concrete Construction of Residential Buildings [Slides]

3D printed concrete construction (C3DP) is an emerging technology that comes with the associated benefits of high thermal mass walls. We investigated using BEopt software the heating and cooling energy use of a single story C3DP-constructed house. We then compared the heating/cooling energy use of the C3DP house against the corresponding energy use in a traditional timber (wood) frame construction (WFC), as well as a concrete masonry unit (CMU) construction. Both peak energy use for heating and cooling (Btu), as well as base energy use for both heating and cooling (MMBtu/yr) of the C3DP design were compared against the WFC and CMU baseline construction of identical geometries and orientations across all eight climate zones defined in the International Energy Conservation Code (IECC). The BEopt models for all three constructions (C3DP, WFC, and CMU) were built to comply with the 2018 IECC code. Results indicate that C3DP construction has significant heating and cooling energy benefits in certain climate zones, with the highest peak cooling energy savings (9% compared to WFC, and 5% compared to CMU) in the IECC Climate Zone 1 in the month of July. The peak heating and cooling energy demand reduction of C3DP were found to be more significant than the base heating and cooling energy demand in all IECC climate zones. The 2018 IECC compliance-related U-Factor adjustments of all models also resulted in more peak energy savings of the C3DP design in the cooling-dominated climate zones (climate zones 1 and 2), moderate energy savings in moderate climate zones (climate zones 3, 4, and 6), and little to no change in energy savings in very cold climates (climate zones 7 and 8).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CRADA Number NFE-19-07846 with Grid Fruit, LLC (CRADA Final Report)

Cooperative Research and Development Agreement (CRADA) NFE-19-07846 between Oak Ridge National Laboratory (ORNL) and Grid Fruit, LLC (Grid Fruit) focused on simulating, monitoring, and adjusting controls of commercial refrigerator and freezer systems to provide load flexibility and demand response services from these machines. Viewing these medium and low-temp coolers as thermal masses, the volumes of chilled air in these coolers make them time-shiftable loads ripe for deployment at optimal times. Grid Fruit is a startup company developing methods to schedule the chilling cycles (e.g., in “build load” and “shed load” grid events) to provide energy efficiency, peak shifting, and other benefits both to the grid and the broader environment. These benefits can be magnified by coordinating chillers with HVAC, lights, computers, and other loads. Grid Fruit completed simulations and then selected and ordered controls hardware to prove the technology were successful, but the diversity of chiller models in the field without digital controls, as well as limited market demand at present, make further exploration necessary before commercialization.

42 ENGINEERING↗

Evaluation of Envelope Energy in a High-Performance Manufactured Home in California

There are important applications for a robust energy model for new construction manufactured homes that can characterize the individual performance of the opaque wall and ceiling components of the building envelope. The efficacy of different insulation materials can be assessed with the confidence that modeled performance will closely predict installed performance. This study uses careful calibration of a standard energy model with a short-term co-heating test in an installed manufactured home to de-aggregate the contributions of planar wall sections from overall building envelope thermal resistance. The methodology takes into account thermal mass effects, solar gains, and physical adjustments to the structure to achieve successful calibration and to inform adjustments to the test procedure for future study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improved melt model for power flow

Accelerators that drive z-pinch experiments transport current densities in excess of 1 MA/cm 2 in order to melt or ionize the target and implode it on axis. These high current densities stress the transmission lines upstream from the target, where rapid electrode heating causes plasma formation, melt, and possibly vaporization. These plasmas negatively impact accelerator efficiency by diverting some portion of the current away from the target, referred to as “current loss”. Simulations that are able to reproduce this behavior may be applied to improving the efficiency of existing accelerators and to designing systems operating at ever higher current densities. The relativistic particle-in-cell code CHICAGO ® is the primary code for modeling power flow on Sandia National Laboratories’ Z accelerator. We report here on new algorithms that incorporate vaporization and melt into the standard power-flow simulation framework. Taking a hybrid approach, the CHICAGO® kinetic/multi-fluid treatment has been expanded to include vaporization while the quasi-neutral equation-of-motion has been updated for melt at high current-densities. For vaporization, a new one-dimensional substrate model provides a more accurate calculation of electrode thermal, mass, and magnetic field diffusion as well as a means of emitting absorbed contaminants and vaporized metal ions. A quasi-fluid model has been implemented expressly to mimic the motion of imploding liners for accurate inductance histories. For melt, a multi-ion Hall-MHD option has been implemented and benchmarked against Alegra MHD. This new model is described with sufficient detail to reproduce these algorithms in any hybrid kinetic code. Physics results from the new code are also presented. A CHICAGO ® Hall-MHD simulation of a radial transmission line demonstrates that Hall physics, not included in Alegra, has no significant impact on the diffusion of electrode material. When surface contaminant desorption is mocked in as a hydrogen surface plasma, both the surface and bulk-material plasmas largely compress under the influence of the j × B force. Similar results are seen in Alegra, which also shows magnetic and material diffusion scaling with peak current. Test vaporization simulations using MagLIF and a power-flow experimental geometry show Fe + ions diffuse only a few hundred µm from the electrodes, so present models of Z power flow remain valid.

43 PARTICLE ACCELERATORS↗

Predicting Building Envelope Construction from In-Situ Thermal Testing

When embarking on a retrofit of a building envelope, it is critical to understand the composition of its assembly. This practice is currently done by destructive and invasive material testing or demolition, which is sometimes not possible when in historic or protected buildings. To address this problem, in-situ thermal testing can be utilized along with machine learning classification algorithms to infer the composition of an assembly. In this paper, a proof-of-concept K-nearest neighbors classification model is developed to classify assembly composition from effective thermal resistance, effective thermal mass, and assembly cladding. This model was trained and tested utilizing a synthetic dataset producing an F1-score of 94.6%. This model was also validated with experimental data from a 100-year old wall assembly, confirming the model’s real-world validity. The paper presents a framework for inferring as-built envelope assemblies, all without having to damage or disturb the building and its occupants.

Pilet, Tyler J.↗

Novel Relaxation Time Approximation: A Consistent Calculation of Transport Coefficients with QCD-inspired Relaxation Times

We use a novel formulation of the relaxation time approximation to consistently calculate the bulk and shear viscosity coefficients using QCDinspired energy-dependent relaxation times and phenomenological thermal masses obtained from fits to lattice QCD thermodynamics. The matching conditions are conveniently chosen to simplify the computations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dark Sector Physics at High-Intensity Experiments

Is Dark Matter part of a Dark Sector? The possibility of a dark sector neutral under Standard Model (SM) forces furnishes an attractive explanation for the existence of Dark Matter (DM), and is a compelling new-physics direction to explore in its own right, with potential relevance to fundamental questions as varied as neutrino masses, the hierarchy problem, and the Universe's matter-antimatter asymmetry. Because dark sectors are generically weakly coupled to ordinary matter, and because they can naturally have MeV-to-GeV masses and respect the symmetries of the SM, they are only mildly constrained by high-energy collider data and precision atomic measurements. Yet upcoming and proposed intensity-frontier experiments will offer an unprecedented window into the physics of dark sectors, highlighted as a Priority Research Direction in the 2018 Dark Matter New Initiatives (DMNI) BRN report. Support for this program -- in the form of dark-sector analyses at multi-purpose experiments, realization of the intensity-frontier experiments receiving DMNI funds, an expansion of DMNI support to explore the full breadth of DM and visible final-state signatures (especially long-lived particles) called for in the BRN report, and support for a robust dark-sector theory effort -- will enable comprehensive exploration of low-mass thermal DM milestones, and greatly enhance the potential of intensity-frontier experiments to discover dark-sector particles decaying back to SM particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bayesian Statistical Analysis for Mass Spectrometric Data Processing

• Thermal ionization mass spectrometry (TIMS) is a “gold standard’ technique for actinide isotope amount ratio and assay measurements. • Ubiquitously used in: • Nuclear Nonproliferation • Nuclear Safeguards • Nuclear Forensics • Basic Science • Savannah River National Laboratory (SRNL) installed a new Thermo Scientific TRITON Plus TIMS in early 2024.

McLarty, Ellis C. [Savannah River National Laborat↗

Bayesian Statistical Analysis for Mass Spectrometric Data Processing

Thermal ionization mass spectrometry (TIMS) is a “gold standard’ technique for actinide isotope amount ratio and assay measurements. • Ubiquitously used in: • Nuclear Nonproliferation • Nuclear Safeguards • Nuclear Forensics • Basic Science • Savannah River National Laboratory (SRNL) installed a new Thermo Scientific TRITON Plus TIMS in early 2024.

McLarty, Ellis C. [Savannah River National Laborat↗

Testing of an Optical Fiber--Based Gamma Thermometer in the High Flux Isotope Reactor Gamma Irradiation Facility

This report describes the design, thermal modeling, and gamma irradiation testing of an optical fiber–based gamma thermometer (OFBGT), which was irradiated in the High Flux Isotope Reactor (HFIR) Gamma Irradiation Facility (GIF). OFBGTs are a promising technology for application in nuclear reactors because they can provide a distributed measurement of gamma ray heating rate, unlike thermocouple-based gamma thermometers, which are fixed in-core sensors that can be used in boiling water reactors to calibrate local power range monitors. OFBGTs measure gamma ray heating rate by measuring the temperature difference between a pair of optical fibers; one fiber is in thermal contact with a heat sink (usually the reactor coolant), and the other is in thermal contact with a thermally isolated mass. The device can be calibrated with a heating wire within the thermal mass. The OFBGT that was designed and fabricated at Oak Ridge National Laboratory can measure distributed gamma ray heating rate over an effective measurement length of 61 cm, and the outer diameter of the sensor is 12.7 mm, giving the prototypical sensor design a relatively small footprint. The sensor housing is backfilled with Ar to ensure a well-predicted thermal response that is not affected by humidity or chemical interactions during operation. For calibration, the sensor design uses a Ni–Cr wire, which can be supplied with currents from 0 to 1 A to capture the wide range of potential gamma ray heating rates expected in HFIR’s spent fuel elements. The OFBGT was thermally modeled analytically and numerically; both models account for temperature-dependent thermal conductivities of the materials and show good agreement. The thermal response of the sensor inside spent HFIR fuel elements was simulated for times up to 1 year after discharge of the fuel element. Out-of-pile open-air tests indicated that the steady-state response of the sensor matches modeled results within experimental uncertainty. Calibration tests were performed using electrical heating in the HFIR spent fuel pool, above the fuel elements, to establish a relationship between the difference in spectral shift measured by optical fibers located inside and outside the OFBGT and the applied electrical heating. Subsequently, the OFBGT was placed within the the spent fuel element from HFIR cycle 501 to measure the spatial profile of the gamma heating rates. Results showed good agreement between the theoretical and measured gamma dose rate profiles, with maximum deviations of ~10% or less.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Neutron Scattering Law for Beryllium Hydride and Critical Mass Calculations

The thermal neutron scattering law (TSL) for crystalline beryllium hydride (BeH 2 ) is developed from first-principles ab initio lattice dynamics calculations and the impact of neutron thermalization in this material on critical mass is estimated. BeH 2 has a body-centered orthorhombic crystal structure with 12 molecules per unit cell and a theoretical density of 0.755 g/cm 3 . The vibrational (phonon) densities of states for H and Be bound in BeH 2 are determined using VASP density functional theory and PHONON lattice dynamics calculations. The TSLs for H bound in BeH 2 , H(BeH 2 ), and Be bound in BeH 2 , Be(BeH 2 ), are then evaluated in the incoherent approximation from the calculated H and Be partial phonon density of states using FLASSH. Finally, critical mass as a function of 235 U loading density for bare and reflected BeH 2 moderated spheres is predicted from MC21 Monte Carlo neutron transport calculations using ENDF/B-VIII.0 cross sections and the H(BeH 2 ) and Be(BeH 2 ) TSL evaluations. Comparisons are made to water (H 2 O), polyethylene (CH 2 ), and beryllium oxide (BeO) as moderators. These critical mass predictions are a refinement upon the prior work by Rao and Srinivasan that neglected thermal neutron scattering effects. The minimum critical mass of a BeH 2 moderated assembly is estimated to be 0.207 kg 235 U for a 0.20 m thick BeO reflected sphere and 0.178 kg 235 U for a 0.40 m thick BeO reflected sphere.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Particle composition measurements for ultrafine particles collected at the EPCAPE Mount Soledad site from 04-27-2023 to 06-13-2023 using a Thermal Desorption Chemical Ionization Mass Spectrometer

The dataset contains particle composition data for both the positive and negative reagent ion modes of the Thermal Desorption Chemical Ionization Mass Spectrometer (TDCIMS). The dataset is split into two directories: one for particles with diameters of 30 nm and the other for particles with diameters of less than 100 nm. The positive reagent ion mode uses H3O+ as the reagent ion, and ionization usually occurs through hydrogen addition. The negative mode uses O2- as the reagent ion. Negative mode ionization generally occurs through hydrogen abstraction, but O2- addition is also possible. Ion concentrations were normalized to total ion counts, and unknown ions were then removed from the data. The name of each ion fraction time series includes the mass to charge ratio and the chemical formula for the ion. Time is recorded in seconds since 1/1/1904. The time zone is UTC.

54 ENVIRONMENTAL SCIENCES↗

Perturbation theory and thermal transport in mass-disordered alloys: Insights from Green's function methods

Lowest-order quantum perturbation theory (Fermi's golden rule) for phonon-disorder scattering has been used to predict thermal conductivities in several semiconducting alloys with surprising success given its underlying hypothesis of weak and dilute disorder. In this paper, we explain how this is possible by focusing on the case of maximally mass-disordered Mg 2 Si 1-x Sn x . In this work, we use a Chebyshev polynomials Green's function method, which allows a full treatment of disorder on very large systems (tens of millions of atoms) to probe individual phonon linewidths and frequency-resolved thermal transport. We demonstrate that the success of perturbation theory originates from the specific form of mass disorder terms in the phonon Green's function and from the interplay between anharmonic and disorder scattering.

36 MATERIALS SCIENCE↗