Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMIONIC CATHODE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Effects of emitting surfaces and trapped ions on the sheath physics and current flow in multidimensional plasma systems

Recent one-dimensional simulations of planar sheaths with strong electron emission have shown that trapping of charge-exchange ions causes transitions from space-charge limited (SCL) to inverse sheaths. However, multidimensional emitting sheath phenomena with collisions remained unexplored, due in part to high computational cost. As such, we developed a novel continuum kinetic code to study the sheath physics, current flow and potential distributions in two-dimensional unmagnetized configurations with emitting surfaces. For small negatively biased thermionic cathodes in a plasma, the cathode sheath can exist in an equilibrium SCL state. The SCL sheath carries an immense density of trapped ions, neutralized by thermoelectrons, within the potential well of the virtual cathode. For further increases of emitted flux, the trapped ion cloud expands in space. The trapped ion space charge causes an increase of thermionic current far beyond the saturation limit predicted by conventional collisionless SCL sheath models without ion trapping. For sufficiently strong emission, the trapped ion cloud consumes the entire 2D plasma domain, forming a mode with globally confined ions and an inverse sheath at the cathode. In situations where the emitted flux is fixed and the bias is swept (e.g. emissive probe), the trapped ions cause a large thermionic current to escape for all biases below the plasma potential. Strong suppression of the thermionic emission, required for the probe to float, only occurs when the probe is above the plasma potential.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bare-tether cathodic contact through thermionic emission by low-work-function materials

A new material, C12A7:e{sup -} electride, which might present a work function as low as 0.6 eV and moderately high temperature stability, was recently proposed as coating for floating bare tethers. Arising from heating under space operation, current is emitted by thermionic emission along a thus coated cathodic segment. A preliminary study on the space-charge-limited (SCL) double layer in front of the cathodic segment is presented using Langmuir's SCL electron current between cylindrical electrodes and orbital-motion-limited ion-collection sheath. A detailed calculation of current and bias profiles along the entire tether length is carried out with ohmic effects and the transition from SCL to full Richardson-Dushman emission included. Analysis shows that in the simplest drag mode, under typical orbital and tether conditions, thermionic emission leads to a short cathodic section and may eliminate the need for an active cathodic device and its corresponding gas feed requirements and power subsystem, which results in a truly 'propellant-less' tether system for such basic applications as de-orbiting low earth orbit satellites.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultra-high vacuum photoelectron linear accelerator

An rf linear accelerator for producing an electron beam. The outer wall of the rf cavity of said linear accelerator being perforated to allow gas inside said rf cavity to flow to a pressure chamber surrounding said rf cavity and having means of ultra high vacuum pumping of the cathode of said rf linear accelerator. Said rf linear accelerator is used to accelerate polarized or unpolarized electrons produced by a photocathode, or to accelerate thermally heated electrons produced by a thermionic cathode, or to accelerate rf heated field emission electrons produced by a field emission cathode.

43 PARTICLE ACCELERATORS↗

Experimental Investigation of Active Feedback Control of Turbulent Transport in a Magnetized Plasma

A new and unique basic plasma science laboratory device - the HelCat device (HELicon-CAThode) - has been constructed and is operating at the University of New Mexico. HelCat is a 4 m long, 0.5 m diameter device, with magnetic field up to 2.2 kG, that has two independent plasmas sources - an RF helicon source, and a thermionic cathode. These two sources, which can operate independently or simultaneously, are capable of producing plasmas with a wide range of parameters and turbulence characteristics, well suited to a variety of basic plasma physics experiments. An extensive set of plasma diagnostics is also operating. Experiments investigating the active feedback control of turbulent transport of particles and heat via electrode biasing to affect plasma ExB flows are underway, and ongoing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MAGNETIZED GRIDDED THERMIONIC ELECTRON SOURCE

A crucial part of achieving JLab's proposed electron ion collider (JLEIC) design luminosity is the application of electron cooling to reduce the ion emittance. One required cooling method is Bunched Beam Cooling (BBC). This cooling process requires beam characteristics that are difficult to achieve. In particular, a high current magnetized electron beam. Here we present a magnetized gridded cathode thermionic electron source, deigned and built by Xelera Research LLC as part of the DOE SBIR program, that could represent the correct technology to use in achieving BBC, as well as a beamline at JLab that will be used to characterize the source.

Stefani, M.↗

WE-G-BRD-09: Novel MRI Compatible Electron Accelerator for MRI-Linac Radiotherapy

Purpose: MRI guided radiotherapy is a rapidly growing field; however current linacs are not designed to operate in MRI fringe fields. As such, current MRI- Linac systems require magnetic shielding, impairing MR image quality and system flexibility. Here, we present a bespoke electron accelerator concept with robust operation in in-line magnetic fields. Methods: For in-line MRI-Linac systems, electron gun performance is the major constraint on accelerator performance. To overcome this, we propose placing a cathode directly within the first accelerating cavity. Such a configuration is used extensively in high energy particle physics, but not previously for radiotherapy. Benchmarked computational modelling (CST, Darmstadt, Germany) was employed to design and assess a 5.5 cell side coupled accelerator with a temperature limited thermionic cathode in the first accelerating cell. This simulation was coupled to magnetic fields from a 1T MRI model to assess robustness in magnetic fields for Source to Isocenter Distance between 1 and 2 meters. Performance was compared to a conventional electron gun based system in the same magnetic field. Results: A temperature limited cathode (work function 1.8eV, temperature 1245K, emission constant 60A/K/cm{sup 2}) will emit a mean current density of 24mA/mm{sup 2} (Richardson’s Law). We modeled a circular cathode with radius 2mm and mean current 300mA. Capture efficiency of the device was 43%, resulting in target current of 130 mA. The electron beam had a FWHM of 0.2mm, and mean energy of 5.9MeV (interquartile spread of 0.1MeV). Such an electron beam is suitable for radiotherapy, comparing favourably to conventional systems. This model was robust to operation the MRI fringe field, with a maximum current loss of 6% compared to 85% for the conventional system. Conclusion: The bespoke electron accelerator is robust to operation in in-line magnetic fields. This will enable MRI-Linacs with no accelerator magnetic shielding, and minimise painstaking optimisation of the MRI fringe field. This work was supported by US (NIH) and Australian (NHMRC & Cancer Institute NSW) government research funding. In addition, I would like to thank cancer institute NSW and the Ingham Institute for scholarship support.

60 APPLIED LIFE SCIENCES↗

Thermionic Properties of Carbon Based Nanomaterials Produced by Microhollow Cathode PECVD

Thermionic emission is the process in which materials at sufficiently high temperature spontaneously emit electrons. This process occurs when electrons in a material gain sufficient thermal energy from heating to overcome the material's potential barrier, referred to as the work function. For most bulk materials very high temperatures (greater than 1500 K) are needed to produce appreciable emission. Carbon‐based nanomaterials have shown significant promise as emission materials because of their low work functions, nanoscale geometry, and negative electron affinity. One method of producing these materials is through the process known as microhollow cathode PECVD. In a microhollow cathode plasma, high energy electrons oscillate at very high energies through the Pendel effect. These high energy electrons create numerous radical species and the technique has been shown to be an effective method of growing carbon based nanomaterials. In this work, we explore the thermionic emission properties of carbon based nanomaterials produced by microhollow cathode PECVD under a variety of synthesis conditions. Initial studies demonstrate measureable current at low temperatures (approximately 800 K) and work functions (approximately 3.3 eV) for these materials.

Haase, John R.↗

Beam Measurement of 11.424 GHz X-Band Linac for Compton Scattering X-ray Source

An inverse Compton scattering X-ray source for medical applications, consisting of an X-band (11.424 GHz) linac and Q-switched Nd:YAG laser, is currently being developed at the University of Tokyo. This system uses an X-band 3.5-cell thermionic cathode RF gun for electron beam generation. We can obtain a multi-bunch electron beam with this gun. The beam is accelerated to 30 MeV by a traveling-wave accelerating tube. So far, we have verified stable beam generation (around 2.3 MeV) by using the newly designed RF gun and we have succeeded in beam transportation to a beam dump.

43 PARTICLE ACCELERATORS↗

Evolution of the radiation processing industry

Early investigations of the effects of treating materials with ionizing radiations began in 1894 with the irradiation of gases at atmospheric pressure using cathode rays from a Crookes gas-discharge tube, in 1895 with the discovery of X-rays emitted from a Crookes tube, and in 1896 with the discovery of radioactivity in uranium. In 1897, small electrically charged particles were detected and identified in the gas discharges inside Crookes tubes. These particles were then named electrons. During the next three decades, it was found that these novel forms of energy could produce ions to initiate chemical reactions in some gases and liquids. By 1921, it had also been shown that insects, parasites and bacteria could be killed by treatment with ionizing radiation. In 1925, a high-vacuum tube with a thermionic cathode and a thin metallic anode was developed to produce electron beams in air by using accelerating potentials up to 250 kilovolts. That unique apparatus was the precursor of the many types of electron accelerators that have been developed since then for a variety of industrial applications. In 1929, the vulcanization of natural rubber without using any chemical additives was achieved by irradiation with electrons from a 250 kilovolt accelerator. In 1939, several liquid monomers were polymerized by treatment with gamma rays from radioactive nuclides. These early results were not exploited before the end of World War II because intense sources of ionizing radiation were not available then. Shortly after that war, there was increased interest in developing the peaceful uses of atomic energy, which included the chemical and biological effects of radiation exposures. Many uses that have been developed since then are described briefly in this paper. These industrial applications are now producing billions of US dollars in revenue every year.

36 MATERIALS SCIENCE↗

Helicon plasma generator-assisted surface conversion ion source for the production of H{sup -} ion beams at the Los Alamos Neutron Science Center

The converter-type negative ion source currently employed at the Los Alamos Neutron Science Center (LANSCE) is based on cesium enhanced surface production of H{sup -} ion beams in a filament-driven discharge. In this kind of an ion source the extracted H{sup -} beam current is limited by the achievable plasma density which depends primarily on the electron emission current from the filaments. The emission current can be increased by increasing the filament temperature but, unfortunately, this leads not only to shorter filament lifetime but also to an increase in metal evaporation from the filament, which deposits on the H{sup -} converter surface and degrades its performance. Therefore, we have started an ion source development project focused on replacing these thermionic cathodes (filaments) of the converter source by a helicon plasma generator capable of producing high-density hydrogen plasmas with low electron energy. In our studies which have so far shown that the plasma density of the surface conversion source can be increased significantly by exciting a helicon wave in the plasma, and we expect to improve the performance of the surface converter H{sup -} ion source in terms of beam brightness and time between services. The design of this new source and preliminary results are presented, along with a discussion of physical processes relevant for H{sup -} ion beam production with this novel design. Ultimately, we perceive this approach as an interim step towards our long-term goal, combining a helicon plasma generator with an SNS-type main discharge chamber, which will allow us to individually optimize the plasma properties of the plasma cathode (helicon) and H{sup -} production (main discharge) in order to further improve the brightness of extracted H{sup -} ion beams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On-site Real-Time Inspection System for Pump-impeller using X-band Linac X-ray Source

The methods of nondestructive testing (NDT) are generally ultrasonic, neutron, eddy-current and X-rays, NDT by using X-rays, in particular, is the most useful inspection technique having high resolution. We can especially evaluate corroded pipes of petrochemical complex, nuclear and thermal-power plants by the high energy X-ray NDT system. We develop a portable X-ray NDT system with X-band linac and magnetron. This system can generate a 950 keV electron beam. We are able to get X-ray images of samples with 1 mm spatial resolution. This system has application to real time impeller inspection because linac based X-ray sources are able to generate pulsed X-rays. So, we can inspect the rotating impeller if the X-ray pulse rate is synchronized with the impeller rotation rate. This system has application in condition based maintenance (CBM) of nuclear plants, for example. However, 950 keV X-ray source can only be used for thin tubes with 20 mm thickness. We have started design of a 3.95 MeV X-band linac for broader X-ray NDT application. We think that this X-ray NDT system will be useful for corrosion wastage and cracking in thicker tubes at nuclear plants and impeller of larger pumps. This system consists of X-band linac, thermionic cathode electron gun, magnetron and waveguide components. For achieving higher electric fields the 3.95 MeV X-band linac structure has the side-coupled acceleration structure. This structure has more efficient acceleration than the 950 keV linac with alternating periodic structure (APS). We adopt a 1.3 MW magnetron for the RF source. This accelerator system is about 30 cm long. The beam current is about 150 mA, and X-ray dose rate is 10 Gy at 1 m/500 pps. In this paper, the detail of the whole system concept and the electromagnetic field of designed linac structure will be reported.

43 PARTICLE ACCELERATORS↗

Wavelength modulation laser-induced fluorescence for plasma characterization

Laser-Induced Fluorescence (LIF) spectroscopy is an essential tool for probing ion and atom velocity distribution functions (VDFs) in complex plasmas. VDFs carry information about the kinetic properties of species that is critical for plasma characterization. Accurate interpretation of these functions is challenging due to factors such as multicomponent distributions, broadening effects, and background emissions. Our research investigates the use of Wavelength Modulation (WM) LIF to enhance the sensitivity of VDF measurements. Unlike standard Amplitude Modulation (AM) methods, WM–LIF measures the derivative of the LIF signal. This approach makes variations in VDF shape more pronounced. VDF measurements with WM–LIF were investigated with both numerical modeling and experimental measurements. The developed model enables the generation of both WM and AM signals, facilitating comparative analysis of fitting outcomes. Experiments were conducted in a weakly collisional argon plasma with magnetized electrons and non-magnetized ions. Measurements of the argon ion VDFs employed a narrow-band tunable diode laser, which scanned the 4p 4 D 7/2 –3d 4 F 9/2 transition centered at 664.553 nm in vacuum. A lock-in amplifier detected the second harmonic WM signal, which was generated by modulating the laser wavelength with an externally controlled piezo-driven mirror of the diode laser. Finally, our findings indicate that the WM–LIF signal is more sensitive to fitting parameters, allowing for better identification of VDF parameters such as the number of distribution components, their temperatures, and velocities. In addition, WM–LIF can serve as an independent method to verify AM measurements and is particularly beneficial in environments with substantial light noise or background emissions, such as those involving thermionic cathodes and reflective surfaces.

47 OTHER INSTRUMENTATION↗

Efficient continuous-wave normal conducting accelerator for industrial applications

A normal conducting, high power, high efficiency copper linear accelerator prototype is being developed for industrial applications. The system will be powered by low-cost high-efficiency magnetron RF sources and will use a gridded thermionic cathode electron gun. Leveraging the significant accelerator expertise at JLab and industry partners, these technologies will be combined to deliver high-power (>100 kW) electron beams with energies of 1 MeV or higher that are cost-effective to produce and operate. The design is modular such that energy and power can be increased by adding additional sections as required. The status of the design, prototype fabrication and plans for a beam demonstration at JLab are described.

Accelerator Physics↗

Preliminary Study on Two Possible Bunch Compression Schemes at NLCTA

In this paper, two possible bunch compression configurations are proposed and evaluated by numerical simulation in the Next Linear Collider Test Accelerator (NLCTA) at SLAC. A bunch compression ratio up to 20 could be achieved under a perfect condition, without consideration for the timing jitter and other error sources. The NLCTA is a test accelerator built at SLAC, which is approximately 42 meters long and composed of X-band acceleration structures. The main aim of building NLCTA is to develop and demonstrate the X-band rf acceleration technologies for the next generation linear collider, with a relatively high acceleration gradient between 50 MV/m and 100 MV/m. The current operation configuration of NLCTA features a thermionic-cathode electron gun at its starting point which generates an electron beam with an energy of 5 MeV. This is followed by a roughly 1.5 meter long X-band acceleration structure which boosts the electron beam energy to 60 MeV. Then there is a four-dipole magnetic chicane which is 6 meters long and provides a first order longitudinal dispersion of R{sub 56} = -73mm. Next the electron beam passes by several matching quadrupoles and can be accelerated further to 120 MeV through another one-meter-long X-band acceleration structure. After that, there are three small chicanes downstream, with a total first order longitudinal dispersion of R{sub 56} = -10mm. A sketch of the main components of NLCTA is shown in Figure 1, where the total length of this accelerator is 45 meters. Free Electron Lasers (FELs), proposed by J. Madey and demonstrated for the first time at Stanford University in 1970s [2] [3], use the lasing of relativistic electron beam traveling through a magnetic undulator, which can reach high power and can be widely tunable in wavelength. Linac based FEL source can provide sufficient brightness, and a short X-ray wavelength down to angstrom scale, which promises in supporting wide range of research experiments. In order to have an electron beam lasing coherently in an undulator, one needs a very bright beam in all three dimensions. In other words, one needs an electron beam with very short bunch length (high intensity), very small transverse emittance and very small energy spread. Most FELs currently being operated, commissioned, constructed or proposed are based on RF acceleration in a frequency range from L-band ( 1 GHz) to C-band ( 6 GHz). As RF frequency goes higher, wake fields effects tend to be much stronger and jitter tolerances are tighter. To demonstrate that X-band acceleration structures can be applied in constructing an FEL, one could perform bunch compression experiments at NLCTA as a first step, and investigate tolerances on timing jitter, misalignments etc.. Another important point is to evaluate the transverse emittance growth in this bunch compression process. In the following sections, two possible bunch compression schemes are proposed to be tested at NLCTA. Elegant [4] 3-D simulation is performed to evaluate these two schemes, with wake fields, space charge and coherent synchrotron radiation (CSR) effects included. One million macro particles are adopted in the numerical simulations. The simulation starts with an electron beam of 20 pC at a beam energy of 5 MeV. The initial RMS bunch length is taken as 0.5 ps at such a low bunch charge, and the RMS energy spread is 5 x 10{sup -3}. The normalized transverse emittance is 1 mm.mrad.

43 PARTICLE ACCELERATORS↗

New Photocathode materials for electron-ion-colliders

Our aim has been to explore new photocathode materials and schemes to develop strategies and technologies for next generation nuclear physics accelerator capabilities, particularly for Electron Ion Colliders (EIC). Thus, we investigated thin film deposition and ensuing properties for several adequate magnetic materials applicable to spin-polarized photocathodes. We also implemented a full experimental setup for light incidence at an acute angle onto the photocathode surface in order to excite surface Plasmon resonance hence increasing light absorption by a metallic surface. We successfully tested the setup with a thermionic cathode as well as Plasmonic silver-MgO samples and obtained very encouraging results. Our first results are very encouraging since the photocurrent measured on this preliminary plasmonic Ag-MgO sample under low power (~ 1mW) cw red light from a HeNe laser was 256 pA, thus two orders magnitude larger than that reported by others following also plasmonic approaches. We extended our studies to shorter wavelengths and we also started preliminary work on chemically ordered MnAl thin films –a component of the tertiary Ag-Mn-Al (silmanal) alloy in order to develop spin-polarized photocathodes capable of sustaining surface Plasmon resonance. It is worthwhile mentioning that a graduate student has been directly involved during this project ensuring the training of next generation of scientists in this area of research.

43 PARTICLE ACCELERATORS↗

Application of the solid lubricant molybdenum disulfide by sputtering

Molybdenum disulfide lubricant film is deposited on two substrates, niobium and nickel-chromium alloys, by means of physical direct-current sputtering. The sputtering system uses a three-electrode /triode/ geometry - a thermionic cathode, an anode, and the target, all enclosed in a vacuum chamber.

Przybyszewski, J.↗

CdS-metal contact at higher current densities.

An investigation is conducted concerning the mechanisms by which a steady flow of current proceeds through the contact when an external voltage is applied. The main characteristics of current mechanisms are examined, giving attention to photoemission from the cathode, thermionic emission, minority-carrier extraction, and the tunneling of electrons. A high-field domain analysis is conducted together with experimental studies. Particular attention is given to the range in which tunneling predominates.

Stirn, R. J.↗

In-FEEP ion beam neutralization with thermionic and field emission cathodes

Charge neutralization of an In-FEEP thruster was demonstrated with three different electron sources by zeroing the floating potential of the thruster and neutralizer system. The three cathodes used in the investigation include a mixed metal thermionic cathode, a carbon nanotube field emission cathode, and a Spindt-type Mo field emission array cathode.

field emission cathodes FEEP electric propulsion↗