Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMOCOUPLE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Thermocouple time constant measurement by cross power spectra

A method of measuring thermocouple time constants is outlined which requires Fourier signal processing. In this method, two thermocouples of differing time constants are placed in a gas flow as closely as possible to one another, and the time constant of the first thermocouple is determined directly from the extremum of the imaginary part of the ratio of the ensemble averaged cross-power spectrum to the ensemble averaged auto-power spectrum of that thermocouple. A coherence function is given for assuring the quality of the data, and results are presented for an experimental test of the method. Some problems with the method are briefly noted.

Strahle, W. C.↗

Thermocouples measure very-hot gas temperatures

Thermocouple probe incorporates small jet of inert gas to cool thermocouple. To measure gas temperatures, cooling jet is turned off momentarily, allowing thermocouple to heat up to near its melting point, then cooling is reapplied. Heating curve is recorded by high speed digital system. Computing system extrapolates final temperature thermocouple would have attained.

Glawe, G. E.↗

Evaluation of miniature single-wire sheathed thermocouples for turbine blade temperature measurement

Chromel Alumel thermocouples were used, with sheath diameters of 0.15 and 0.25 mm. Tests were conducted at temperatures ranging from 750 to 1250 K. Both steady state and thermal cycling tests were performed for times up to 200 hours. Initial testing was performed in a low velocity gas stream for long time periods using a Meker-type burner. Additional testing was done in a high velocity gas stream for short time periods using a hot gas tunnel and also in a J75 jet engine. A total of eleven 0.15 mm diameter thermocouples and six 0.25 mm diameter thermocouples were tested. Drift rates up to 2.5% in 10 hours were observed. Photomicrographs show that this design is near the limit of miniaturization based on present manufacturing capabilities. Results indicate that the effects of miniaturization on reliability and accuracy must be considered when choosing thermocouples for a particular application.

Hollanda, R.↗

Adhesive-Bonded Tab Attaches Thermocouples to Titanium

Mechanical strength of titanium-alloy structures that support thermocouples is preserved by first spotwelding thermocouples to titanium tabs and then attaching tabs to titanium with a thermosetting adhesive. In contrast to spot welding, a technique previously used for thermocouples, fatigue strength of the titanium is unaffected by adhesive bonding. Technique is also gentler than soldering or attaching thermocouples with a tap screw.

Cook, C. F.↗

Frequency response in short thermocouple wires

Theoretical expressions are derived for the steady state frequency response of a thermocouple wire. In particular, the effects of axial heat conduction are demonstrated for a nonuniform wire with unequal material properties and wire diameters across the junction. The amplitude ratio at low frequency omega approaches 0 agrees with the results of Scadron and Warshawsky (1952) for a steady state temperature distribution. Moreover, the frequency response for a nonuniform wire in the limit of infinite length l approaches infinity is shown to reduce to a simple expression that is analogous to the classic first order solution for a thermocouple wire with uniform properties. Theoretical expressions are also derived for the steady state frequency response of a supported thermocouple wire. In particular, the effects of axial heat conduction are demonstrated for both a supported one material wire and a two material wire with unequal material properties across the junction. For the case of a one material supported wire, an exact solution is derived which compares favorably with an approximate expression that only matches temperatures at the support junction. Moreover, for the case of a two material supported wire, an analytical expression is derived that closely correlates numerical results. Experimental measurements are made for the steady state frequency response of a supported thermocouple wire. In particular, the effects of axial heat conduction are demonstrated for both a supported one material wire (type K) and a two material wire (type T) with unequal material properties across the junction. The data for the amplitude ratio and phase angle are correlated to within 10 pct. with the theoretical predictions of Forney and Fralick (1991). This is accomplished by choosing a natural frequency omega sub n for the wire data to correlate the first order response at large gas temperature frequencies. It is found that a large bead size, however, will increase the amplitude ratio at low frequencies but decrease the natural frequency of the wire. The phase angle data are also distorted for imperfect junctions.

Forney, L. J.↗

A computer-controlled apparatus for Seebeck inhomogeneity testing of sheathed thermocouples

Mineral-insulated metal-sheathed (MIMS) thermocouple assemblies are used throughout industry and research facilities as a method of temperature measurement where requirements for either harsh environmental conditions exist, or where rigidity of the measurement probe is required. Seebeck inhomogeneity is the abnormal variation of the Seebeck coefficient from point to point in a material. It is not disclosed in conventional calibration. A standardized method of measuring thermoelectric inhomogeneity along the thermocouple probe length is not available. Therefore, calibration for sheathed probes normally does not include testing of probe inhomogeneity. The measurement accuracy would be severely impacted if significant inhomogeneity and a temperature gradient were present in the same region of the probe. A computer-controlled system for determining inhomogeneities was designed, fabricated, and tested. This system provides an accurate method for the identification of the location of inhomogeneity along the length of a sheathed thermocouple and for the quantification of the inhomogeneity. This paper will discuss the apparatus and procedure used to perform these tests and will present data showing tests performed on sheathed thermocouple probes.

Burkett, Cecil G., Jr.↗

High-Temperature, Oxidation-Resistant Thermocouples

Aluminum substituted for rhodium, which is scarce and expensive. Electromotive force increases with aluminum content in Pt/Al leg of Pt(Pt/Al) thermocouple. Wires baked longer in aluminizing bed produce larger voltages. Thermocouples containing platinum/aluminum legs used instead of thermocouples of type R in furnaces, heat engines, and chemical reactors. Expecially suited to high-velocity oxidizing environments. Constructed as thin-film sensors on turbine blades and vanes, where pre-oxidation provides insulating film needed between thermocouple legs. Because aluminum content slowly depleted by oxidation, long-term use recommended only where maximum temperature is 1,200 degrees C or less.

Smialek, James L.↗

Three-Wire Thermocouple: Frequency Response in Constant Flow

Theory and experimental measurements are compared with a novel three-wire thermocouple. Signals from three wires of unequal diameters are recorded from the thermocouple suspended in constant flow with a periodic temperature fluctuation. It is demonstrated that the reconstructed signal from the three-wire thermocouple requires no compensation for omega less than or equal to 5(omega(sub 1)), where omega(sub 1) is the natural frequency of the smaller wire. The latter result represents a significant improvement compared to previous work with two-wire thermocouples. A correction factor has also been derived to account for wires of arbitrary diameter.

Forney, L. J.↗

Three-wire Thermocouple: Frequency Response in Constant Flow

Theory and experimental measurements are compared with a novel three-wire thermocouple. Signals from three wires of unequal diameters arc recorded from the thermocouple suspended in constant flow with a periodic temperature fluctuation. It is demonstrated that the reconstructed signal from the three-wire thermocouple requires no compensation for omega less than or equal to 5(sub omega1), where omega, is the natural frequency of the smaller wire. The latter result represents a significant improvement compared to previous work with two-wire thermocouples. A correction factor has also been derived to account for wires of arbitrary diameter.

Forney, L. J.↗

Advanced Microscopic Integrated Thermocouple Arrays

The purpose of this research is to develop and refine a technique for making microscopic thermocouple arrays for use in measuring the temperature gradient across a solid-liquid interface during the solidification process. Current thermocouple technology does not allow for real-time measurements across the interface due to the prohibitive size of available thermocouples. Microscopic thermocouple arrays will offer a much greater accuracy and resolution of temperature measurements across the solid-liquid interface which will lead to a better characterization of the solidification process and interface reaction which affect the properties of the resulting material.

Pettigrew, Penny J.↗

Thin film ceramic thermocouples

A thin film ceramic thermocouple (10) having two ceramic thermocouple (12, 14) that are in contact with each other in at least on point to form a junction, and wherein each element was prepared in a different oxygen/nitrogen/argon plasma. Since each element is prepared under different plasma conditions, they have different electrical conductivity and different charge carrier concentration. The thin film thermocouple (10) can be transparent. A versatile ceramic sensor system having an RTD heat flux sensor can be combined with a thermocouple and a strain sensor to yield a multifunctional ceramic sensor array. The transparent ceramic temperature sensor that could ultimately be used for calibration of optical sensors.

Gregory, Otto↗

Thermocouple assembly

Disclosed is a thermocouple assembly having a resilient mount; a buffer having a first side and a second side, with the buffer first side connecting with the resilient mount; an insulator having a first side and a second side, with the insulator first side connecting with the buffer second side; and a thermocouple having a first side and a second side, the thermocouple first side connecting with the insulator second side, and the thermocouple second side being configured to be in thermal contact with an object to be measured.

Schwarting, Nelson↗

In situ embedment of type K sheathed thermocouples with directed energy deposition

Advanced nuclear reactor systems require new technologies for heat transfer and system monitoring. Additive manufacturing (AM) offers the design flexibility to allow in-situ sensor embedment through smart manufacturing for real-time monitoring, and performance of these systems. Here, this study focuses on experiments investigating the feasibility of in-situ sensor embedment using directed energy deposition (DED). Type K thermocouples are embedded into 316L stainless steel (SS) samples using two different configurations (e.g., exposed and embedded tips) and two designs (e.g., flush to substrate) within an AM base. Embedded sensor samples are analyzed via in-situ measurements and high-temperature performance validation tests at 350ºC and 900ºC. Temperature performance results at both temperature tests show good agreement with manufacturer specifications proving that these sensors could still capture accurate temperature readings after in-situ embedment during DED processing. An additional optimization experiment was conducted on the exposed tip configuration using a surrogate thermocouple to improve tolerances and the embedment process. Results improved tolerances, lower porosity, smaller gaps between the sensor and base, and better junction contact for the sensor. Although further optimization of this embedment strategy is necessary to improve the structural stability and tolerances within the component, this research strategy provides a proof-of-feasibility for DED embedment with commercial sheathed thermocouples. This research provides early impact on embedment of sensor for multiple materials and complex geometric components..

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Preparation of W-Ta thin-film thermocouple on diamond anvil cell for in-situ temperature measurement under high pressure

In this paper, a W-Ta thin-film thermocouple has been integrated on a diamond anvil cell by thin-film deposition and photolithography methods. The thermocouple was calibrated and its thermal electromotive force was studied under high pressure. The results indicate that the thermal electromotive force of the thermocouple exhibits a linear relationship with temperature and is not associated with pressure. The resistivity measurement of ZnS powders under high pressure at different temperatures shows that the phase transition pressure decreases as the temperature increases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Traceable Co-C eutectic points for thermocouple calibration

National Measurement Institute of Australia (NMIA) has developed a miniature crucible design suitable for measurement by both thermocouples and radiation thermometry, and has established an ensemble of five Co-C eutectic-point cells based on this design. The cells in this ensemble have been individually calibrated using both ITS-90 radiation thermometry and thermocouples calibrated on the ITS-90 by the NMIA mini-coil methodology. The assigned ITS-90 temperatures obtained using these different techniques are both repeatable and consistent, despite the use of different furnaces and measurement conditions. The results demonstrate that, if individually calibrated, such cells can be practically used as part of a national traceability scheme for thermocouple calibration, providing a useful intermediate calibration point between Cu and Pd.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self-calibration of a W/Re thermocouple using a miniature Ru-C (1954 °C) eutectic cell

Previous successful investigations of miniature cobalt-carbon (Co-C, 1324 °C) and palladium-carbon (Pd-C, 1492 °C) high temperature fixed-point cells for thermocouple self-calibration have been reported [1-2]. In the present work, we describe a series of measurements of a miniature ruthenium-carbon (Ru-C) eutectic cell (melting point 1954 °C) to evaluate the repeatability and stability of a W/Re thermocouple (type C) by means of in-situ calibration. A miniature Ru-C eutectic fixed-point cell with outside diameter 14 mm and length 30 mm was fabricated to be used as a self-calibrating device. The performance of the miniature Ru-C cell and the type C thermocouple is presented, including characterization of the stability, repeatability, thermal environment influence, ITS-90 temperature realization and measurement uncertainty.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New fixed-point mini-cell to investigate thermocouple drift in a high-temperature environment under neutron irradiation

Temperature measurements in the nuclear field require a high degree of reliability and accuracy. Despite their sheathed form, thermocouples subjected to nuclear radiations undergo changes due to radiation damage and transmutation that lead to significant EMF drift during long-term fuel irradiation experiment. For the purpose of a High Temperature Reactor fuel irradiation to take place in the High Flux Reactor Petten, a dedicated fixed-point cell was jointly developed by LNE-Cnam and JRC-IET. The developed cell to be housed in the irradiation rig was tailor made to quantify the thermocouple drift during the irradiation (about two year duration) and withstand high temperature (in the range 950 deg. C - 1100 deg. C) in the presence of contaminated helium in a graphite environment. Considering the different levels of temperature achieved in the irradiation facility and the large palette of thermocouple types aimed at surveying the HTR fuel pebble during the qualification test both copper (1084.62 deg. C) and gold (1064.18 deg. C) fixed-point materials were considered. The aim of this paper is to first describe the fixed-point mini-cell designed to be embedded in the reactor rig and to discuss the preliminary results achieved during some out of pile tests as much as some robustness tests representative of the reactor scram scenarios. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Reduction of Random Uncertainty in Differential Temperature Measurements Using Common Leg Thermocouples

The uncertainty quantification of random error is considered for common leg thermocouples (i.e., where one thermoelement is shared along the length of the TC for all other TC junctions present). The uncertainty is presented for both a common leg and individual, separate leg thermocouples. For Type K thermocouples a reduction in uncertainty by up to 3x is capable when differential temperatures, ?T, are within 150°C, and diminishes to little to no improvement above 150°C.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗