Search NASA⌕ Search

SEARCH · Search NASA

Results for “THRESHOLD DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Observations of cosmic gamma-ray bursts with IMP-7: Evidence for a single spectrum

Spectral observation of nine recent cosmic gamma-ray bursts are reported. The average photon number spectra of all nine events are shown to be consistent with a 150-keV exponential from 100 keV to about 400 keV, and a power law of index -2.5 from 400 keV to 1100 keV. The observations also indicate an event rate of 16 in 1972 and 1973, or 8 + or - 2 per year, higher than the 5 + or - 1 per year initially reported. This corresponds to an approximately 40-percent lower effective intensity threshold, attained by using more sensitive detectors in multiple-satellite coincidence.

Cline, T. L.↗

Angular distributions of electrons of energy E sub e greater than 0.06 MeV in the Jovian magnetosphere

The results of an angular distribution analysis of the electron intensity data recorded near Jupiter for the period from 26 November to 14 December 1973 are presented. The data were from three directional particle detectors with effective integral electron energy thresholds of 0.06, 0.55, and 5.0 Mev, respectively. It was found that the central core of the magnetosphere, within 12 Jupiter radii, is dominated by pitch angle distributions strongly peaked at alpha = 90 deg, while the region from 12 to 25 Jupiter radii shows bidirectional and approximately equal maxima at alpha = 0 and 180 deg. Bidirectional angular distributions in the magnetodisc out to the radius of the magnetopause strongly suggest quasi-trapping on closed field lines as the predominant situation. Substantial field aligned, unidirectional streaming was detected on only two occasions. No distinctive effects on angular distributions were discerned near the L-shells of satellites.

Sentman, D. D.↗

Observations of cosmic gamma-ray bursts with IMP-7 - Evidence for a single spectrum

Spectral observations of nine recent cosmic gamma-ray bursts are reported. The average photon number spectra of all nine events are each consistent with a 150-keV exponential from 100 keV to about 400 keV, and a power law of index -2.5 from 400 keV to 1100 keV. The observations also indicate an event rate of 16 in 1972 and 1973, or 8 plus or minus 2 per year, higher than the 5 plus or minus 1 per year initially reported. This corresponds to an approximately 40 percent lower effective intensity threshold, attained by using more sensitive detectors in multiple-satellite coincidence.

Cline, T. L.↗

A 163 micron laser heterodyne radiometer for OH

A 163 micron (1.836 THz) radiometer developed for airplane and/or balloon platforms is described. The laser local oscillator is a CO2 pumped methanol laser operating at a frequency which is approx. 1 GHz from the J = 3/2 - 1/2 transition of OH. The laser is used directly as a local oscillator or is translated in frequency to closer coincidence with the OH emission, depending on achieved detector IF bandwidth. Frequency translation techniques which are described are diode mixing and a method of single sideband generation using an external Stark modulated gas cell. The photoconductive mixer used is a strained Ge crystal, doped with Ga, originally used as an incoherent detector. The uniaxial strain on the Ga doped Ge crystal shifts the threshold for photoconduction from 100/cm to frequencies as low as 50/cm. These detectors are currently being characterized as mixers in the laboratory. Of particular interest are the effect of local oscillator power and strain on IF, bandwidth detector impedance, and conversion loss. Preliminary results of these tests are described and compared with theorectical expectations.

Pickett, H. M.↗

The search for evidence of particle acceleration at SN 1987A in MeV to PeV gamma rays

The prospects for obtaining evidence of the particle acceleration by SN 1987A pulsar wind are discussed. It is noted that, of the seven experiments that searched for high-energy signals since the discovery of SN 1987A, operating in both the TeV region (air Cerenkov arrays) and the 100-TeV region (air shower arrays), not one has reported a continuous signal from the supernova. The only signal reported so far that could be interpreted as a signal from the supernova remnant is from an air shower experiment YANZOS (Bond, 1988), in which a transient flux of photons above 3 TeV was observed. It is pointed out however, that, if a TeV signal is seen, the accompanying gamma-ray flux around 100 MeV should be well above threshold for detection by the EGRET detector on Gamma-Ray Observatory.

Harding, Alice K.↗

Access Accommodation Study

A new mission payload concept for the International Space Station (ISS) called ACCESS (Advanced Cosmic-ray Composition Experiment for Space Station) has undergone a preliminary study which is now complete, and its results are published here. The mission holds the promise for answering many of the outstanding astrophysical questions associated with Galactic cosmic rays and their role in our Galaxy. ACCESS science goals include measurement of the rare ultra-high energy and ultra-heavy components of cosmic radiation which have not been analyzed previously above the Earth's atmosphere. The critical resource made available by the ISS is collection factor (area x exposure time), as much as 10,000 square meters-sr-days for a four-year stay on-orbit. This will allow ACCESS to go beyond balloon-borne detectors and take the science of cosmic-ray observation to the threshold of space. The ACCESS instrument, consisting of a charge module, a transition radiation detector, and a calorimeter, should make valuable measurements of nuclei throughout the periodic table up to 1015 eV. The concept, options, mission plan, and accommodation issues for such an ISS payload are summarized. This includes the carrier, ISS Site, mass, thermal control, power, data and operations. The study demonstrates that the ISS, as a stable science platform at the threshold of space, makes improved cosmic-ray ACCESS possible at the turn of the century.

Wilson, Thomas L.↗

Sample Diluter for Detecting Hypergolic Propellants and Other Toxic or Hazardous Gases

Hardware was developed to dilute vapor samples of purged hypergolic propellants (with air) into the range of existing instruments for detection of such toxic vapors. Since these detectors are normally used to monitor at the threshold limit value (TLV), most do not have quantitative capability at percent levels which relate to lower explosion limit (LEL) and fire hazards. For example, the upper limits of Energetic Sciences (ESI) 6000 series detectors used at KSC are 200 parts per million (ppm) for monomethyl hydrazine (MMH) and 500 ppm for nitrogen dioxide (NO2) arising from decomposition of nitrogen tetroxide (N2O4). Orbiter Processing Facility (OPF) personnel servicing Shuttle thrusters need to measure up to 250 ppm MMH and 7,500 ppm NO2 with portable, intrinsically safe instruments. Our objective was to quickly fabricate a sample diluter out of existing materials as a temporary measure while other parallel efforts were conducted to provide a commercial or in-house-developed instrument to detect high propellant levels. A 3 to 1 diluter would bring 500 ppm MMH into the range of the existing fuel ESI, and a 30 to 1 diluter would do the same for NO2. In this way, familiar equipment already available would be used, resulting in minimal paperwork, safety, and training impacts and low cost. An MMH vapor sample-diluter was constructed from a 1/4-inch Kynar tee, along with specially designed lengths of sample and dilution tubing. The sample line was 3 feet of Bev-A-Line 4, 1/4-inch tube leading to the straight run of the tee. The side run of the tee had a 17-inch length of Bev-A-Line 4, 1/4-inch tube, for nominal 3 to 1 dilution. A gas sample bag was prepared and assayed at 113 ppm ppm MMH, and diluted vapor samples were assayed at 39.5 ppm, or a measured dilution of 2.9 to 1. For NO2, a 316 stainless steel (SS) 1/8-inch tee with 49.5 inches of coiled, 1/8-inch outside diameter (OD) 316 SS tubing was used as the sampling end of the dilution system. The side run of the tee was open. The measured dilution ratio, based on the input value of 6,480 ppm NO2, and the average output value of 233 ppm, was 28 to 1. Thus, sample-diluters were successful in diluting concentrated hypergolic propellant vapors, both MMH and N2O4 into the ranges of existing TLV detectors.

Barile, R. G.↗

Sample Diluter for Detecting Hypergolic Propellants and Other Toxic or Hazardous Gases

Hardware was developed to dilute vapor samples of purged hypergolic propellants (with air) into the range of existing instruments for detection of such toxic vapors. Since these detectors are normally used to monitor at the threshold limit value (TLV), most do not have quantitative capability at percent levels which relate to lower explosion limit (LEL) and fire hazards. For example, the upper limits of Energetic Sciences (ESI) 6000 series detectors used at KSC are 200 parts per million (ppm) for monomethyl hydrazine (MMH) and 500 ppm for nitrogen dioxide (NO2) arising from decomposition of nitrogen tetroxide (N2O4). Orbiter Processing Facility (OPF) personnel servicing Shuttle thrusters need to measure up to 250 ppm MMH and 7500 ppm NO2 with portable, intrinsically safe instruments. Our objective was to quickly fabricate a sample diluter out of existing materials as a temporary measure while other parallel efforts were conducted to provide a commercial or in-house-developed instrument to detect high propellant levels. A 3 to 1 diluter would bring 500 ppm MMH into the range of the existing fuel ESI, and a 30 to 1 diluter would do the same for NO2. In this way, familiar equipment already available would be used, resulting in minimal paperwork, safety, and training impacts and low cost. An MMH vapor sample-diluter was constructed from a 1/4-inch Kynar tee, along with specially designed lengths of sample and dilution tubing. The sample line was 3 feet of Bev-A-Line 4, 1/4 inch tube leading to the straight run of the tee. The side run of the tee had a 17-inch length of Bev-A-Line 4, 1/4-inch tube, for nominal 3 to 1 dilution. A gas sample bag was prepared and assayed at 113 ppm MMH, and diluted vapor sarnples were assayed at 39.5 ppm, or a measured dilution of 2.9 to 1. For NO2, a 316 stainless steel (SS) 1/8-inch tee with 49.5 inches of coiled, 1/8-inch outside diameter (OD) 316 SS tubing was used as the sarnpling end of the dilution system. The side run of the tee was open. The measured dilution ratio, based on the input value of 6,480 ppm NO2 and the average output value of 233 ppm, was 28 to 1. Thus, sample-diluters were successful in diluting concentrated hypergolic propellant vapors, both MMH and N2O4, into the ranges of existing TLV detectors.

Barile, R. G.↗

Cross sections relevant to gamma ray astronomy

Gamma-ray production cross sections were measured for protons and alpha particles incident on targets consisting of nuclei of high cosmic abundance: C-12, N-14, O-16, Ne-20, Mg-24, Si-28 and Fe-56. Solid or gaseous targets were bombarded by monoenergetic beams of protons and alpha particles, and gamma rays were detected by two Ge(Li) detectors. The proton energy for each target was varied from threshold to about 24 MeV (lab); for alphas the range was from threshold to about 27 MeV. For most transitions, it was possible to measure the total cross section by placing the detectors at 30.5 deg and 109.9 deg where the fourth-order Legendre polynomial is zero. For the case of the 16O (E sub gamma = 6.13 MeV, multipolarity E3) cross sections, yields were measured at four angles. Absolute cross sections were obtained by integrating the beam current and by measuring target thicknesses and detector efficiencies. The Ge(Li) detector resolution was a few keV (although the peak widths were greater, due to Doppler broadening).

Dyer, P.↗

CMOS detector cells for holographic optical interconnects in microcircuits

This paper reports on the characterization of CMOS detectors for holographic optical interconnects in micro circuits. A VLSI temporal response system has been built, which has high-magnification viewing capabilities to facilitate the identification of the sample area under investigation. An isolated photodiode and load circuit has been characterized to determine responsivity, response time, and light spot positioning effects. The threshold of optical gate cells incorporating the above detectors and a transistor inverter stage to couple to other circuitry has been determined. The rise time and fall time of the optical gate cells have also been determined experimentally. The results were compared with the results of SPICE simulation, and show satisfactory agreement. The time delay of optical gate cell output was thus determined to be 70 ns at 10 microW light input. Threshold power was 0.5 microW light input.

Wu, W. H.↗

High Z particle Apollo astronaut dosimetry with plastics

On Apollo missions, the individual astronauts' high Z particle exposure is measured by means of Lexan polycarbonate plastic. These layers form one component of the passive dosimetry packets worn in the constant wear garment. They serve as threshold type, high Z, charged particle track detectors, recording only the very highly ionizing particles. The detectors yield information on the particles' charge, energy, and direction of travel. This data, in turn, is used to obtain the track fluence, the stopping particle density as an integral Z distribution, and the particles' integral LET spectrum. Some of the data gathered on Apollo missions 8-13 is presented.

Benton, E. V.↗

Lightning discharge identification system

A system for differentiating between cloud to cloud and cloud to ground lightning discharges is described which includes an electric field antenna that senses the rate of charge of an electric field produced by a lightning discharge. When the signal produced by the electric field exceeds a predetermined threshold, it is fed to a coincidence detector. A VHF antenna is also provided and generates a video signal responsive to a cloud to cloud lightning discharge, and this signal is fed through a level sensor, an inverter, to the coincidence detector simultaneously with the signal from the field detector. When signals from the electric field antenna and the VHF antenna appear at the coincidence detector simultaneously, such indicates that there is a cloud to cloud lightning discharge; whereas, when there is not a signal produced on the VHF antenna simultaneously with a signal produced by the field sensor, then a strike indicator connected to the coincidence detector indicates a cloud to ground lightning discharge.

Lennon, C. L.↗

Time and energy dependence of the cosmic ray gradient in the outer heliosphere

Pioneers 10 and 11, now 35 and 18 AU from the Sun, continue to extend our knowledge of the spatial dependence of cosmic ray intensities in the heliosphere. Radial gradients measured from these spacecraft by UCSD detectors which have integral energy responses above thresholds of 80 and 500 MeV/nucleon are reported. An average gradient of 2%/AU typifies the data set as a whole, but there are time and energy dependences that deviate from this value. With operating lifetimes of 13 and 12 years, respectively, for the two spacecraft, the time dependence was followed for over a solar cycle. The higher energy channel shows less modulation on all time scales. At the start of the present cycle, the gradient is lower than the average value during the last solar cycle.

Fillius, W.↗

1 - 100 GeV Emission from Millisecond Pulsars

A number of rotation-powered millisecond pulsars are powerful sources of high-energy emission, detected so far at X-ray wavelengths. We present predictions for the spectral characteristics of these sources at gamma-ray energies, using a model for acceleration and pair cascades on open magnetic field lines above the polar caps. Although these pulsars have low surface magnetic fields, their short periods allow them to have large magnetospheric potential drops, but the majority do not produce sufficient pairs to completely screen the accelerating electric field. In these sources, the primary and secondary electrons continue to accelerate to high altitude and their Lorentz factors are limited by curvature and synchrotron radiation reaction. The resulting radiation above 1 GeV comes from curvature radiation by primary electrons with radiation-reaction-limited Lorentz factors. The spectra are very hard power-laws with exponential cutoffs between 1 and 50 GeV, and the spectral power peaks near the cutoff energy. Millisecond pulsars are thus ideal targets for air-Cherenkov detectors that are able to reach energy thresholds below 50 GeV.

Harding, Alice K.↗

Detection threshold energy of high energy cascade showers using thermoluminescence PTFE-sheet and hot-gas reader

A new thermoluminescence (TL) sheet was developed as a detector for high energy components in air showers. For the investigation of detection threshold energy for a cascade showeer, TL sheets were exposed at Mt. Fuji with X ray films in emulsion chambers and were scanned by a hot-gas reader. It is concluded that if a gamma ray whose energy is more than 6 TeV enters vertically into lead chambers, the resulting cascade shower is readily detectable at maximum development.

Kino, S.↗

Smoke detection in low-G fires

Fires in spacecraft are considered a credible risk. To respond to this risk, NASA flew fire detectors on Skylab and the Space Shuttle (STS) and included them in the design for International Space Station Alpha (ISSA). In previous missions (Mercury, Gemini and Apollo), the crew quarters were so cramped that it was not considered credible that the astronauts could fail to observe a fire. The Skylab nodule included approximately 20 UV fire detectors. The space shuttle has 9 ionization detectors in the mid deck and flight deck and Spacelab has six additional ionization detectors. The planned detectors for ISSA are laser-diode, forward-scattering, smoke or particulate detectors. Current plans for the ISSA call for two detectors in the open area of the module and detectors in racks that have both cooling air flow and electrical power. Due to the complete absence of data concerning the nature of particulate and radiant emission from low-g fires, all three of these detector systems were designed based upon 1-g test data. As planned mission durations and complexity increase and the volume of spacecraft increases, the need for and importance of effective, crew independent, fire detection grows significantly. This requires more knowledge concerning low-gravity fires and how they might be detected. To date, no combustion-generated particulate samples have been collected for well-developed microgravity flames. All of the extant data come from drop tower tests and therefore only correspond to the early stages of a fire. The fuel sources were restricted to laminar gas-jet diffusion flames and rapidly overheated wire insulation. These gas-jet drop tower tests indicate, through thermophoretic sampling, that soot primaries and aggregates (groups of primary particles) in micro-g may be significantly larger than those in normal-g (ng). This raises new scientific questions about soot processes as well as practical issues for particulate detection/alarm threshold levels used in on-orbit smoke detectors. Furthermore, it is widely speculated but unverified that the aggregates will grow to very large scales in a microgravity fire of longer duration than available on the ground. Preliminary tests in the 2.2 second drop tower suggest that particulate generated by overheated wire insulation will also be larger in microgravity than in normal gravity. TEM grids downstream of the fire region in the WIF experiment as well as visual observation of long string-like aggregates, further confirm this suggestion. The combined impact of these limited results and theoretical predictions is that direct knowledge of low-g combustion particulate as opposed to extrapolation from 1-g data is needed for a more confident design of smoke detectors for spacecraft.

Urban, David L.↗

Ion-implanted extrinsic Ge photodetectors with extended cutoff wavelength

Far-IR Ge detectors fabricated using boron ion implantation are shown to exhibit operating characteristics compatible with requirements for low background applications. Device parameters such as low dark currents, reasonably good sensitivity, and extended wavelength threshold demonstrate that ion-implanted Ge far-IR detectors offer promise for use in astrophysics instrumentation.

Wu, I. C.↗

Comparative Soot Diagnostics: Preliminary Results

The motivation for the Comparative Soot Diagnostics (CSD) experiment lies in the broad practical importance of understanding combustion generated particulate. Depending upon the circumstances, particulate matter can affect the durability and performance of combustion equipment, can be a pollutant, can be used to detect fires and, in the form of soot, can be the dominant source of radiant energy from flames. The nonbuoyant structure of most flames of practical interest makes understanding of soot processes in low gravity flames important to our ability to predict fire behavior on earth. These studies also have direct applications to fire safety in human-crew spacecraft, since smoke is the indicator used for automated detection in current spacecraft. In the earliest missions (Mercury, Gemini and Apollo), the crew quarters were so cramped that it was considered reasonable that the astronauts would rapidly detect any fire. The Skylab module, however, included approximately 20 UV-sensing fire detectors. The Space Shuttle has 9 particle-ionization smoke detectors in the mid-deck and flight deck and Spacelab has six additional particle-ionization smoke detectors. The designated detectors for the ISS are laser-diode, forward-scattering, smoke or particulate detectors. Current plans for the ISS call for two detectors in the open area of the module, and detectors in racks that have both cooling air flow and electrical power. Due to the complete absence of data concerning the nature of particulate and radiant emission from incipient and fully developed low-g fires, all three of these detector systems were designed based upon l-g test data and experience. As planned mission durations and complexity increase and the volume of spacecraft increases, the need for and importance of effective, crew-independent, fire detection grows significantly. To provide this level of protection, more knowledge is needed concerning low-gravity fire phenomena and, in particular, how they might be detected and suppressed. Prior to CSD, no combustion-generated particulate samples had been collected near the flame zone for well-developed microgravity flames. All of the extant data either came from drop tower tests and therefore only corresponded to the early stages of a fire or were collected far from the flame zone. The fuel sources in the drop tower tests were restricted to laminar gas-jet diffusion flames and very rapidly overheated wire insulation. The gas-jet tests indicated, through thermophoretic sampling, (2) that soot primaries and aggregates (groups of primary particles) in low-gravity may be significantly larger than those in normal gravity (1-g). This raises new scientific questions about soot processes as well as practical issues for particulate size sensitivity and detection alarm threshold levels used in on-orbit smoke detectors. Preliminary tests in the 2.2 second drop tower suggest that particulate generated by overheated wire insulation may be larger in low-g than in 1-g. Transmission Electron Microscope (TEM) grids downstream of the fire region in the Wire Insulation Flammability experiment as well as visual observation of long string-like aggregates, further confirm this suggestion. The combined impact of these limited results and theoretical predictions is that, as opposed to extrapolation from l-g data, direct knowledge of low-g combustion particulate is needed for more confident design of smoke detectors for spacecraft. This paper describes the operation and preliminary results of the CSD, a project conceived and developed at NASA Lewis Research Center. The CSD flight experiment was conducted in the Middeck Glovebox Facility (MGBX) on USMP-3. The project is support by NASA Headquarters Microgravity Science and Applications Division and Code Q. The results presented here are from the microgravity portion of the experiment, including the temporal response of the detectors and average sizes of the primary and aggregate particles captured on the thermophoretic probes.

Urban, David L.↗