Search NASA⌕ Search

SEARCH · Search NASA

Results for “TOF resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Ruggedizing a Commercial Depth Camera for Novel Lunar Exploration.

The novel contribution of this instrument is to take the first depth images on the moon. A commercial Kinect camera from Microsoft has been ruggedized for a CLPS mission to the Lunar South Pole. The 12-megapixel color camera is combined with a 1-megapixel color time-of-flight (ToF) depth sensor. The solid-state depth sensor/LIDAR provides greater resolution, a wider field of view, pixel binning, and reduced power consumption. The high-resolution data collected from the mission can be used to construct a near-field virtual environment of the lunar surface for scientific applications. The depth camera can provide a 360-degree view of the target area by combining ToF data with RGB imagery and rover turning. The unit was evaluated for space flight compliant materials and parts at NASA Ames. The microphone array, RF shield, front face, and outer body parts were removed to reduce mass. Plastic parts were replaced with vacuum-compatible materials; manufactured cables were added to properly interface with the host rover, built by Lunar Outpost. The environmental testing was performed on the Kinect with Random Vibration/Sine Testing (Fig 1a), per GEVS (NASA’s General Environmental Verification Standard for spaceflight launch survival). Thermal Vacuum testing cycled the instrument between expected hot (+ 85 C) and cold survival temperatures, as well as +50 C and -25 C operational temps (Fig 1b). The instrument functioned nominally at the conclusion of vibration and thermal cycling tests. The Azure Kinect is manifested on the Nova-C lander which flies on the Intuitive Machines mission IM-2, landing at the lunar south pole for a mission duration of 14 days (one lunar daylight cycle). The unit will be integrated to the MAPP (Mobile Autonomous Prospecting Platform) rover at Lunar Outpost. The Azure Kinect with ToF feature will improve the resolution of lunar geology data near the south pole and enable ground-based VR experience of details of the lunar surface (Fig 1c).

V. Jha↗

Understanding Chemical Inhomogeneities and Cation Gradients in Perovskite Photovoltaics with TOF-SIMS

Time-of-flight secondary-ion mass spectrometry (TOF-SIMS) is one of the few techniques that can obtain chemical information from all components of hybrid organic-inorganic perovskite photovoltaics in up to three dimensions. This can yield critical insight into the uniformity of the cations through the thickness of the film (with sub-nm resolution), as well as laterally (with 100nm resolution) We have been using a TOF-SIMS to analyze perovskite photovoltaics at NREL for more than four years and have found many tricks and best practices, summarized here, to get around known artifacts when depth profiling and imaging.

14 SOLAR ENERGY↗

A method for extracting calibrated volatility information from the FIGAERO-HR-ToF-CIMS and its experimental application

The Filter Inlet for Gases and AEROsols (FIGAERO) is an inlet specificallydesigned to be coupled with the Aerodyne High-Resolution Time-of-FlightChemical Ionization Mass Spectrometer (HR-ToF-CIMS). The FIGAERO-HR-ToF-CIMSprovides simultaneous molecular information relating to both the gas- andparticle-phase samples and has been used to extract vapour pressures (VPs) ofthe compounds desorbing from the filter whilst giving quantitativeconcentrations in the particle phase. However, such extraction of vapourpressures of the measured particle-phase components requires use ofappropriate, well-defined, reference compounds. Vapour pressures for thehomologous series of polyethylene glycols (PEG)((H-(O-CH 2 -CH 2 )n-OH) for n=3 to n=8), covering a rangeof vapour pressures (VP) (10 -1 to 10 -7 Pa) that areatmospherically relevant, have been shown to be reproduced well by a range ofdifferent techniques, including Knudsen Effusion Mass Spectrometry (KEMS).This is the first homologous series of compounds for which a number of vapourpressure measurement techniques have been found to be in agreement,indicating the utility as a calibration standard, providing an ideal set ofbenchmark compounds for accurate characterization of the FIGAERO forextracting vapour pressure of measured compounds in chambers and the realatmosphere. To demonstrate this, single-component and mixture vapour pressuremeasurements are made using two FIGAERO-HR-ToF-CIMS instruments based on anew calibration determined from the PEG series. VP values extracted from bothinstruments agree well with those measured by KEMS and reported values fromliterature, validating this approach for extracting VP data from the FIGAERO.This method is then applied to chamber measurements, and the vapour pressuresof known products are estimated.

47 OTHER INSTRUMENTATION↗

Application of high-resolution time-of-flight chemical ionization mass spectrometry measurements to estimate volatility distributions of α-pinene and naphthalene oxidation products

Recent developments in high-resolution time-of-flight chemical ionization mass spectrometry (HR-ToF-CIMS) have made it possible to directly detect atmospheric organic compounds in real time with high sensitivity and with little or no fragmentation, including low-volatility, highly oxygenated organic vapors that are precursors to secondary organic aerosol formation. Here, using ions identified by high-resolution spectra from an HR-ToF-CIMS with acetate reagent ion chemistry, we develop an algorithm to estimate the vapor pressures of measured organic acids. The algorithm uses identified ion formulas and calculated double bond equivalencies, information unavailable in quadrupole CIMS technology, as constraints for the number of possible oxygen-containing functional groups. The algorithm is tested with acetate chemical ionization mass spectrometry (acetate-CIMS) spectra of O 3 and OH oxidation products of α-pinene and naphthalene formed in a flow reactor with integrated OH exposures ranged from 1.2 × 10 11 to 9.7 × 10 11 molec s cm −3 , corresponding to approximately 1.0 to 7.5 days of equivalent atmospheric oxidation. Measured gas-phase organic acids are similar to those previously observed in environmental chamber studies. For both precursors, we find that acetate-CIMS spectra capture both functionalization (oxygen addition) and fragmentation (carbon loss) as a function of OH exposure. The level of fragmentation is observed to increase with increased oxidation. The predicted condensed-phase secondary organic aerosol (SOA) average acid yields and O/C and H/C ratios agree within uncertainties with previous chamber and flow reactor measurements and ambient CIMS results. While acetate reagent ion chemistry is used to selectively measure organic acids, in principle this method can be applied to additional reagent ion chemistries depending on the application.

54 ENVIRONMENTAL SCIENCES↗

Study of the Au-Cr bilayer system using X-ray reflectivity, GDOES, and ToF-SIMS

Here, we study a Au (25 nm)/Cr (10 nm) bilayer system as a model of mirror for the soft X–ray energy range. The Au and Cr thin films are a few nanometer thick and are deposited on a float glass substrate. The sample is characterized by using 3 complementary techniques: soft X–ray reflectivity, glow discharge optical emission spectrometry (GDOES), and time–of–flight secondary ion mass spectroscopy (ToF–SIMS). Soft X–ray reflectivity provides information about the thickness and roughness of the different layers, while GDOES is used to obtain the elemental depth profile of the stack and ToF–SIMS to obtain the elemental and chemical depth profiles. GDOES and ToF–SIMS have both a nanometer depth resolution. A coherent description of the bilayer stack is obtained through the combination of these techniques. It consists in 5 layers namely a surface contamination layer, a principal gold layer, a Au–Cr mixed layer, a Cr layer, and another contamination layer at the top of the substrate.

36 MATERIALS SCIENCE↗

Mexico City Aerosol Analysis during MILAGRO using High Resolution Aerosol Mass Spectrometry at the Urban Supersite (T0). Part 1: Fine Particle Composition and Organic Source Apportionment

Submicron aerosol was analyzed during the MILAGRO field campaign in March 2006 at the T0 urban supersite in Mexico City with a High-Resolution Time-of-Flight Aerosol Mass Spectrometer (HR-ToF-AMS) and complementary instrumentation. Mass concentrations, diurnal cycles, and size distributions of inorganic and organic species are similar to results from the CENICA supersite in April 2003 with organic aerosol (OA) comprising about half of the fine PM mass. Positive Matrix Factorization (PMF) analysis of the high resolution OA spectra identifies three major components: chemically-reduced urban primary emissions (hydrocarbon-like OA, HOA), oxygenated OA (OOA, mostly secondary OA or SOA), and biomass burning OA (BBOA) that correlates with levoglucosan and acetonitrile. BBOA includes several very large plumes from regional fires and likely also some refuse burning.

09 BIOMASS FUELS↗

Rapid high-resolution spin- and angle-resolved photoemission spectroscopy with pulsed laser source and time-of-flight spectrometer

A high-efficiency spin- and angle-resolved photoemission spectroscopy (spin-ARPES) spectrometer is coupled with a laboratory-based laser for rapid high-resolution measurements. The spectrometer combines time-of-flight (TOF) energy measurements with low-energy exchange scattering spin polarimetry for high detection efficiencies. Samples are irradiated with fourth harmonic photons generated from a cavity-dumped Ti:sapphire laser that provides high photon flux in a narrow bandwidth, with a pulse timing structure ideally matched to the needs of the TOF spectrometer. The overall efficiency of the combined system results in near-E{sub F} spin-resolved ARPES measurements with an unprecedented combination of energy resolution and acquisition speed. This allows high-resolution spin measurements with a large number of data points spanning multiple dimensions of interest (energy, momentum, photon polarization, etc.) and thus enables experiments not otherwise possible. The system is demonstrated with spin-resolved energy and momentum mapping of the L-gap Au(111) surface states, a prototypical Rashba system. The successful integration of the spectrometer with the pulsed laser system demonstrates its potential for simultaneous spin- and time-resolved ARPES with pump-probe based measurements.

36 MATERIALS SCIENCE↗

Wavelength-independent constant period spin-echo modulated small angle neutron scattering

Spin-Echo Modulated Small Angle Neutron Scattering (SEMSANS) in Time-of-Flight (ToF) mode has been shown to be a promising technique for measuring (very) small angle neutron scattering (SANS) signals and performing quantitative Dark-Field Imaging (DFI), i.e., SANS with 2D spatial resolution. However, the wavelength dependence of the modulation period in the ToF spin-echo mode has so far limited the useful modulation periods to those resolvable with the limited spatial resolution of the detectors available. Here we present our results of an approach to keep the period of the induced modulation constant for the wavelengths utilised in ToF. This is achieved by ramping the magnetic fields in the coils responsible for creating the spatially modulated beam in synchronisation with the neutron pulse, thus keeping the modulation period constant for all wavelengths. Such a setup enables the decoupling of the spatial detector resolution from the resolution of the modulation period by the use of slits or gratings in analogy to the approach in grating-based neutron DFI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wintertime aerosol chemical composition, volatility, and spatial variability in the greater London area

The composition of PM 1 (particulate matter with diameter less than 1 µm) in the greater London area was characterized during the Clean Air for London (ClearfLo) project in winter 2012. Two high-resolution time-of-flight aerosol mass spectrometers (HR-ToF-AMS) were deployed at a rural site (Detling, Kent) and an urban site (North Kensington, London). The simultaneous and high-temporal resolution measurements at the two sites provide a unique opportunity to investigate the spatial distribution of PM 1 . We find that the organic aerosol (OA) concentration is comparable between the rural and urban sites, but the contribution from different sources is distinctly different between the two sites. The concentration of solid fuel OA at the urban site is about twice as high as at the rural site, due to elevated domestic heating in the urban area. While the concentrations of oxygenated OA (OOA) are well-correlated between the two sites, the OOA concentration at the rural site is almost twice that of the urban site. At the rural site, more than 70 % of the carbon in OOA is estimated to be non-fossil, which suggests that OOA is likely related to aged biomass burning considering the small amount of biogenic SOA in winter. Thus, it is possible that the biomass burning OA contributes a larger fraction of ambient OA in wintertime than what previous field studies have suggested. A suite of instruments was deployed downstream of a thermal denuder (TD) to investigate the volatility of PM 1 species at the rural Detling site. After heating at 250 °C in the TD, 40 % of the residual mass is OA, indicating the presence of non-volatile organics in the aerosol. Although the OA associated with refractory black carbon (rBC; measured by a soot-particle aerosol mass spectrometer) only accounts for < 10 % of the total OA (measured by a HR-ToF-AMS) at 250 °C, the two measurements are well-correlated, suggesting that the non-volatile organics have similar sources or have undergone similar chemical processing as rBC in the atmosphere. Although the atomic O : C ratio of OOA is substantially larger than that of solid fuel OA and hydrocarbon-like OA, these three factors have similar volatility, which is inferred from the change in mass concentration after heating at 120 °C. Finally, we discuss the relationship between the mass fraction remaining (MFR) of OA after heating in the TD and atomic O : C of OA and find that particles with a wide range of O : C could have similar MFR after heating. This analysis emphasizes the importance of understanding the distribution of volatility and O : C in bulk OA.

Xu, L.↗

High-resolution Rydberg tagging time-of-flight measurements of atomic photofragments by single-photon vacuum ultraviolet laser excitation

By coupling a comprehensive tunable vacuum ultraviolet (VUV) laser system to a velocity-mapped ion imaging apparatus, we show that high-resolution high-n Rydberg tagging time-of-flight (TOF) measurements of nascent atomic photofragments formed by laser photodissociation can be made using single-photon VUV laser photoexcitation. To illustrate this single-photon Rydberg tagging TOF method, we present here the results of the VUV laser high-n Rydberg tagging TOF measurements of O({sup 3}P{sub 2}) and S({sup 3}P{sub 2}) formed in the photodissociation of SO{sub 2} and CS{sub 2} at 193.3 and 202.3 nm, respectively. These results are compared to those obtained by employing the VUV laser photoionization time-sliced velocity-mapped ion imaging technique. The fact that the kinetic energy resolutions achieved in the VUV laser high-n Rydberg tagging TOF measurements of O and S atoms are found to be higher than those observed in the VUV laser photoionization, time-sliced velocity-mapped ion imaging studies show that the single-photon VUV laser high-n Rydberg tagging TOF method is useful and complementary to state-of-the-art time-sliced velocity-mapped ion imaging measurements of heavier atomic photofragments, such as O and S atoms. Furthermore, the general agreement observed between the VUV laser high-n Rydberg tagging TOF and velocity-mapped ion imaging experiments supports the conclusion that the lifetimes of the tagged Rydberg states of O and S atoms are sufficiently long to allow the reliable determination of state-resolved UV photodissociation cross sections of SO{sub 2} and CS{sub 2} by using the VUV laser high-n Rydberg tagging TOF method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct Measurement of the Composition of Aqueous Fluids from the Parent Body of Asteroid 162173 Ryugu

Imaging using X-ray absorption contrast by synchrotron nano-computed tomography (47.4 nm/voxel, 7keV) of a Ryugu pyrrhotite crystal (C0002-FC012-from the second touch-down site) revealed probable fluid inclusions (Fig. 1A,B) [1]. The inclusions were completely encapsuled in pyrrhotite, suggesting the fluids were trapped in the early stages of crystal growth, and filled with low-Z material. We performed Time-of Flight-Secondary Ion Mass Spectrometry (TOF-SIMS) depth profiling and high-resolution map-ping at -120°C to exposure and measure the composition of the trapped fluids in a frozen state.

M Zolensky↗

Update on Measurement of the Composition of Ryugu Fluid Inclusions

Imaging using X-ray absorption contrast by synchrotron nano-computed tomography of a Ryugu pyrrhotite crystal (C0002-FC012 - from the second Hayabusa2 spacecraft touch-down site) revealed probable fluid inclusions in the center of a crystal of pyrrhotite, suggesting the parent fluids were trapped in the early stages of crystal growth on Ryugu’s parent asteroid. We previously described the performance of Time-of Flight-Secondary Ion Mass Spectrometry (TOF-SIMS) depth profiling and high-resolution mapping at -120°C to expose and measure the composition of the trapped fluids in a frozen state in two Ryugu inclusions [1,2]. Here we report results from follow-on measurements of additional inclusions in the same pyrrhotite crystal, and the initial results of measurement of standards. The ultimate goal is to reveal the quantitative composition of the fluids that caused aqueous alteration, in particular the H2O:CO2 ratio, which will also facilitate cosmochemical modeling of the alteration process.

M Zolensky↗

Direct Analyses of Aqueous Fluids from C-Class Asteroid 162173 Ryugu

Imaging using X-ray absorption contrast by synchrotron nano-computed tomography (47.4 nm/voxel, 7keV) of a Ryugu pyrrhotite crystal revealed probable fluid inclusions. The inclusions were completely encapsuled in pyrrhotite, suggesting the fluids were trapped in the early stages of crystal growth, and filled with low-Z material. We performed Time-of Flight-Secondary Ion Mass Spectrometry (TOF-SIMS) depth profiling and high-resolution mapping at -120°C to exposure and measure the composition of the trapped fluids in a frozen state. These measurements revealed that the ancient, trapped fluids on Ryugu’s parent asteroid were saline aqueous solutions containing H2O, CO2, sulfur species, and nitrogen- and chlorine-bearing organic compounds identified by representative secondary ion species including O(-), OH(-), CO(-), S(-), Cl(-), C2(-), C2H(-), and CN(-). The inferred presence of CO2 indicates formation of the sulfides, and by implication the Ryugu parent body, beyond the H2O and CO2 snow lines of the early solar system, i.e. > 3-4 au from the Sun.

M Zolensky↗

SUDA: A SUrface Dust Analyser for Compositional Mapping of the Galilean Moon Europa

Abstract The Surface Dust Analyser (SUDA) is a mass spectrometer onboard the Europa Clipper mission for investigating the surface composition of the Galilean moon Europa. Atmosphereless planetary moons such as the Galilean satellites are wrapped into a ballistic dust exosphere populated by tiny samples from the moon’s surface produced by impacts of fast micrometeoroids. SUDA will measure the composition of such surface ejecta during close flybys of Europa to obtain key chemical signatures for revealing the satellite’s composition such as organic molecules and salts, history, and geological evolution. Because of their ballistic orbits, detected ejecta can be traced back to the surface with a spatial resolution roughly equal to the instantaneous altitude of the spacecraft. SUDA is a Time-Of-Flight (TOF), reflectron-type impact mass spectrometer, optimized for a high mass resolution which only weakly depends on the impact location. The instrument will measure the mass, speed, charge, elemental, molecular, and isotopic composition of impacting grains. The instrument’s small size of$268 ~\mathrm {mm} \times 250 ~\mathrm {mm} \times 171$ 268 mm × 250 mm × 171 $~\mathrm {mm}$ mm , radiation-hard design, and rather large sensitive area of 220 cm 2 matches well the challenging demands of the Clipper mission.

Astronomy & Astrophysics↗

A two-color tunable infrared/vacuum ultraviolet spectrometer for high-resolution spectroscopy of molecules in molecular beams

We describe here the key technical elements of a two-color tunable IR/VUV photoionization TOF mass spectrometer system which allows a wide-range of high-resolution experiments to be performed on a diverse range of cold molecules and clusters in a molecular beam. In particular we highlight the methods we have applied to provide efficient wavelength separation of the VUV radiation from the longer wavelength components used to generate it and discuss a number of systems that we have studied with the instrument which highlight its flexibility for use in the study of molecular spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FINAL REPORT

Excellent progress was made in standardizing three complementary methods: Magnetic resonance imaging, x-ray micro CT, and MALDI imaging linear ion trap mass spectroscopy to image biomass and chemical, anatomical and functional changes that occur during pretreatment and hydrolysis. Magnetic resonance microscopy provides excellent images with as low as 5 uM resolution with hydrated biomass samples. We visualized dramatic changes in signal associated with the hydrolysis of the carbohydrates by strong acids. Quantitative diffusion approaches were used to probe more subtle structural changes in biomass. Diffusion tensor calculations reflect diffusion anisotropy and fractional anisotropy maps clearly show the longer range diffusion within the vessels compared to within the fiber cells. The diffusion is increased along the cell walls of the vessels. Suggesting that further research with NMR imaging should be pursued. X-ray CT provides excellent images at as low as 3.5 uM resolution from dried biomass. Small increases in surface area, and decreases in local density have been quantified in with wood after mild pretreatments; these changes are expected to be underestimates of the hydrated wood, due to the ~12% shrinkage that occurs upon drying untreated wood. MALDI-MS spectra show high ion intensities at most mass to charge ratios in untreated and pretreated woody material. MALDI-MSn is required to improve specificity and reduce background for imaging. MALDI-TOF is not specific enough for carbohydrate identification. Using MALDI-LIT/MSn we can readily identify oligomeric glucans and xylans and their fragmentation patterns as well as those of the glucuronic acid side chains of birch 4-O-methyl glucuronxylan. Imaging of glucan and xylan oligomers show that many contain isobaric ions with different distributions, indicating again that MSn is needed for accurate imaging of lignocellulosic materials. We are now starting to integrate the three imaging methods by using the same set of biomass samples imaged with all three methods, and using common analytical software to quantify parameters from the three dimensional images. In addition to the proposed experiments, we conducted imaging studies with a novel TOF-SIMS instrument available through collaborations with the AMOLF goup led by Ron Heeren at the FOM Institute in Amersterdam, Netherlands. ToF-SIMS was used to image intact cross sections of Populus stems with high spatial resolution, chemically selectivity. ToF-SIMS images were correlated with fluorescence microscopy which allowed for more positive ion identification.

09 BIOMASS FUELS↗

Mass spectral imaging showing the plant growth-promoting rhizobacteria's effect on the Brachypodium awn

The plant growth-promoting rhizobacteria (PGPR) on the host plant surface play a key role in biological control and pathogenic response in plant functions and growth. However, it is difficult to elucidate the PGPR effect on plants. Such information is important in biomass production and conversion. Brachypodium distachyon (Brachypodium), a genomics model for bioenergy and native grasses, was selected as a C3 plant model; and the Gram-negative Pseudomonas fluorescens SBW25 ( P.) and Gram-positive Arthrobacter chlorophenolicus A6 ( A.) were chosen as representative PGPR strains. The PGPRs were introduced to the Brachypodium seed's awn prior to germination, and their possible effects on the seeding and growth were studied using different modes of time-of-flight secondary ion mass spectrometry (ToF-SIMS) measurements, including a high mass-resolution spectral collection and delayed image extraction. We observed key plant metabolic products and biomarkers, such as flavonoids, phenolic compounds, fatty acids, and auxin indole-3-acetic acid in the Brachypodium awns. Furthermore, principal component analysis and two-dimensional imaging analysis reveal that the Brachypodium awns are sensitive to the PGPR, leading to chemical composition and morphology changes on the awn surface. Our results show that ToF-SIMS can be an effective tool to probe cell-to-cell interactions at the biointerface. This work provides a new approach to studying the PGPR effects on awn and shows its potential for the research of plant growth in the future.

metabolite↗

Avalanche photodiode based time-of-flight mass spectrometry

This study reports on the performance of Avalanche Photodiodes (APDs) as a timing detector for ion Time-of-Flight (TOF) mass spectroscopy. We found that the fast signal carrier speed in a reach-through type APD enables an extremely short timescale response with a mass or energy independent <2 ns rise time for <200 keV ions (1−40 AMU) under proper bias voltage operations. When combined with a microchannel plate to detect start electron signals from an ultra-thin carbon foil, the APD comprises a novel TOF system that successfully operates with a <0.8 ns intrinsic timing resolution even using commercial off-the-shelf constant-fraction discriminators. By replacing conventional total-energy detectors in the TOF-Energy system, APDs offer significant power and mass savings or an anti-coincidence background rejection capability in future space instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗