Search NASA⌕ Search

SEARCH · Search NASA

Results for “TOXICITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A comparative study of the toxicity of the combustion products of Tedlar and a fluorenone-polyester film

The relative toxicity in rats resulting from a 30 minute exposure to the combustion products of two materials, Tedlar and fluorenone-polyester film was assessed. The combustion products were generated into a static exposure system using a laboratory-scale furnace. The toxicity was assessed using the primary measurements employed in a more detailed overall toxicity evaluation. The toxicological events observed during the 30 minute exposure are reported.

Farrar, D. G.↗

Effect of pyrolysis temperature and air flow on toxicity of gases from a polycarbonate polymer

A polycarbonate polymer was evaluated for toxicity of pyrolysis gases generated at various temperatures without forced air flow and with 1 L/min air flow, using the toxicity screening test method developed at the University of San Francisco. Time to various animal responses decreased with increasing pyrolysis temperature over the range from 500 C to 800 C. There appeared to be no significant toxic effects at 400 C and lower temperatures.

Hilado, C. J.↗

Toxicity of pyrolysis gases from polyoxymethylene

A sample of polyoxymethylene was evaluated for toxicity of pyrolysis gases, using the toxicity screening test method developed at the University of San Francisco. Under several test conditions, this material gave shorter times to death than many other synthetic polymers. Carbon monoxide appeared to be the principal toxicant in the pyrolysis gases.

Hilado, C. J.↗

Toxicity of pyrolysis gases from polytetrafluoroethylene

A sample of polytetrafluoroethylene was evaluated for toxicity of pyrolysis gases, using various test conditions of the toxicity screening test method developed at the University of San Francisco. Time to death appears to be affected by the material of which the pyrolysis tube is made, with Monel tending to give longer times to death than quartz. When quartz tubes are used, time to death seems to be related to carbon monoxide concentration. When Monel tubes are used, carbon monoxide does not appear to be the principal toxicant.

Hilado, C. J.↗

Toxicity of pyrolysis gases from polyether sulfone

A sample of polyether sulfone was evaluated for toxicity of pyrolysis gases, using the toxicity screening test method developed at the University of San Francisco. Animal response times were relatively short at pyrolysis temperatures of 600 to 800 C, with death occurring within 6 min. The principal toxicant appeared to be a compound other than carbon monoxide.

Hilado, C. J.↗

Relative toxicity of materials in fire situations

The results of toxicity testing of additional materials is presented. Relative toxicity data on polymers by generic type are presented and include wood, polyurethane flexible foam, polyvinyl chloride (PVC), acrylonitrile/butadiene/styrene (ABS), and polyisoprene (natural rubber). A second table gives relative toxicity data on fibers and fabrics including wool, nylon, rayon, polyester, and aromatic polyamide. Sulfur-containing materials seemed to exhibit the shortest times to death of laboratory animals. Some chlorine-containing polymers tended to exhibit shortest time to death also while some halogen-containing polymers gave the shortest time to incapacitation. Among fibers and fabrics, wool, silk, and polyester exhibited the shortest times to incapacitation and times to death. Difficulty in restricting generally accepted materials is discussed and attention is given to other factors important in comparing materials, such as backcoatings and relative weights.

Hilado, C. J.↗

Toxicity of pyrolysis gases from foam plastics

Twenty-three samples of flexible foams and twelve samples of rigid foams were evaluated for toxicity of pyrolysis gases, using the USF toxicity screening test method. Polychloroprene among the flexible foams, and polystyrene among the rigid foams, appeared to exhibit the least toxicity under these particular test conditions.

Hilado, C. J.↗

Toxic-Waste Disposal by Combustion in Containers

Chemical wastes burned with minimal handling in storage containers. Technique for disposing of chemical munitions by burning them inside shells applies to disposal of toxic materials stored in drums. Fast, economical procedure overcomes heat-transfer limitations of conventional furnace designs by providing direct contact of oxygenrich combustion gases with toxic agent. No need to handle waste material, and container also decontaminated in process. Oxygen-rich torch flame cuts burster well and causes vaporization and combustion of toxic agent contained in shell.

Houseman, J.↗

Toxic substances registry system: Index of material safety data sheets

The Jul. 1992 Revision of the KSC Toxic Substances Registry System (TSRS) Index of Material Safety Data Sheets (MSDS's) is presented. The listed MSDS's reflect product inventories and associated MSDS's which were submitted to the Toxic Substance Registry Data Base maintained by the Base Operations Contractors of the Biomedical Operations and Research Office of KSC. The purpose of the index is to provide a means of accessing information on the hazards associated with the toxic and otherwise hazardous chemicals stored and used at KSC. Indices are provided for manufacturers, trademarks, and stock numbers.

Source record↗

Toxic substances registry system: Index of material safety data sheets

The Oct. 1992 Revision of the KSC Toxic Substances Registry System (TSRS) Index of Material Safety Data Sheets (MSDS's) is presented. The listed MSDS's reflect product inventories and associated MSDS's which were submitted to the Toxic Substance Registry Data Base maintained by the Base Operations Contractors of the Biomedical Operations and Research Office of KSC. The purpose of the index is to provide a means of accessing information on the hazards associated with the toxic and otherwise hazardous chemicals stored and used at KSC. Indices are provided for manufacturers, trademarks, and stock numbers.

Source record↗

Toxic substances registry system: Index of material safety data sheets

The Jan. 1993 Revision of the KSC Toxic Substances Registry System (TSRS) Index of Material Safety Data Sheets (MSDS's) is presented. The listed MSDS's reflect product inventories and associated MSDS's which were submitted to the Toxic Substance Registry Data Base maintained by the Base Operations Contractors of the Biomedical Operations and Research Office of KSC. The purpose of the index is to provide a means of accessing information on the hazards associated with the toxic and otherwise hazardous chemicals stored and used at KSC. Indices are provided for manufacturers, trademarks, and stock numbers.

Source record↗

Toxicity study of dimethylethoxysilane (DMSES), the waterproofing agent for the Orbiter heat protective system

DMES, a volatile liquid, is used by NASA to waterproof the Orbiter thermal protective system. During waterproofing operations at the Oribter Processing Facility at KSC, workers could be exposed to DMES vapor. To assess the toxicity of DMES, acute and subchronic (2-week and 13-week) inhalation studies were conducted with rats. Studies were also conducted to assess the potential of DMES. Inhalation exposure concentrations ranged from 40 ppm to 4000 ppm. No mortality was observed during the studies. Exposures to 2100 ppm produced narcosis and ataxia. Post-exposure recovery from these CNS effects was rapid (less than 1 hr). These effects were concentration-dependent and relatively independent of exposure length. Exposure to 3000 ppm for 2 weeks (5 h/d, 5 d/wk) produced testicular toxicity. The 13-week study yielded similar results. Results from the genotoxicity assays (in vivo/in vitro unscheduled DNA synthesis in rat primary heptaocytes, chromosomal aberrations in rat bone marrow cells; reverse gene mutation in Salmonella typhimurium; and forward mutation in Chinese hamster culture cells) were negative. These studies indicated that DMES is mildly to moderately toxic but not a multagen.

Lam, Chiu-Wing↗

Toxic substances registry system: Index of material safety data sheets

The Material Safety Data Sheets (MSDS's) listed in this index reflect product inventories and associated MSDS's which were submitted to the Toxic Substances Registry database maintained by the Base Operations Contractor at the Kennedy Space Center. The purpose of this index is to provide KSC government, contractor, and tenant organizations a means to access information on the hazards associated with these chemicals. The Toxic Substance Registry Service (TSRS) was established to manage information dealing with the storage and use of toxic and otherwise hazardous materials at KSC. As a part of this service, the BOC Environmental Health Services maintains a central repository of MSDS's which were provided to TSRS. The data on the TSRS are obtained from NASA, contractor, and tenant organizations who use or store hazardous materials at KSC. It is the responsibility of these organizations to conduct inventories, obtain MSDS's, distribute Hazard Communication information to their employees, and otherwise implement compliance with appropriate Federal, State, and NASA Hazard Communication and Worker Right-to-Know regulations and policies.

Source record↗

Computerized in vitro test for chemical toxicity based on tetrahymena swimming patterns

An apparatus and method for rapidly determining chemical toxicity was evaluated. The toxicity monitor includes an automated scoring of how motile biological cells (Tetrahymena pyriformis) slow down or otherwise change their swimming patterns in a hostile chemical environment. The device, called the Motility Assay Apparatus (MAA) is tested for 30 second determination of chemical toxicity in 20 aqueous samples containing trace organics and salts. With equal or better detection limits, results compare favorably to in vivo animal tests of eye irritancy, in addition to agreeing for all chemicals with previous manual evaluations of single cell motility.

Noever, David A.↗

Computerized In Vitro Test for Chemical Toxicity Based on Tetrahymena Swimming Patterns

An apparatus and a method for rapidly determining chemical toxicity have been evaluated as an alternative to the rabbit eye initancy test (Draize). The toxicity monitor includes an automated scoring of how motile biological cells (Tetrahymena pyriformis) slow down or otherwise change their swimming patterns in a hostile chemical environment. The method, called the motility assay (MA), is tested for 30 s to determine the chemical toxicity in 20 aqueous samples containing trace organics and salts. With equal or better detection limits, results compare favorably to in vivo animal tests of eye irritancy.

Noever, David A.↗

Pulmonary Toxicity Study of Lunar and Martian Dust Simulants Intratracheally Instilled in Mice

NASA is contemplating sending humans to Mars and the Moon for further exploration. The properties of Hawaiian and Californian volcanic ashes allow them to be used to simulate Martian and lunar dusts, respectively. NASA laboratories use these dust simulants to test performance of hardware destined for Martian or lunar environments. Workers in these test facilities are exposed to low levels of these dusts. The present study was conducted to investigate the toxicity of these dust simulants. Particles of respirable-size ranges of lunar simulant (LS), Martian simulant (MS), TiO2 (negative control) and quartz (positive control) were each intratracheally instilled (saline as vehicle) to groups of 4 mice (C57BL, male, 2-3 month old) at a single treatment of 1 (Hi dose) or 0.1 (Lo dose) mg/mouse. The lungs were harvested at the end of 7 days or 90 days for histopathological examination. Lungs of the LS-Lo groups had no evidence of inflammation, edema or fibrosis. The LS-Hi-7d group had mild to moderate acute inflammation, and neutrophilic and lymphocytic infiltration; the LS-Hi-90d group showed signs of chronic inflammation and some fibrosis. Lungs of the MS-Lo-7d group revealed mild inflammation and neutrophilic and lymphocytic infiltration; the MS-Lo-90d group showed mild fibrosis and particle-laden macrophages (PLM). Lungs of the MS-Hi-7d group demonstrated mild to moderate inflammation and large foci of PLM; the MS-Hi-90d group showed chronic mild to moderate inflammation and fibrosis. To mimic the effects of the oxidative and reactive properties of Martian soil surface, groups of mice were exposed to ozone (3 hour at 0.5 ppm) prior to MS dust instillation. Lung lesions in the MS group were more severe with the pretreatment. The results for the negative and positive controls were consistent with the known pulmonary toxicity of these compounds. The overall severity of toxic insults to the lungs were TiO2<LS<MS<Quartz. For the mice in the 90-d study, blood samples were taken for immunotoxicity study. Antinuclear antibodies (such as those against Golgi, kinetichore, and centromere) were detected in serum in a greater extent in mice treated with LS than those with quartz, suggesting that LS, like quartz, has the potential of inducing antoimmune disease.

Lam, Chiu-Wing↗

Web-Based Toxic Gas Dispersion Model for Shuttle Launch Operations

During the launch of the Space Shuttle vehicle, the burning of liquid hydrogen fuel with liquid oxygen at extreme high temperatures inside the three space shuttle main engines, and the burning of the solid propellant mixture of ammonium perchlorate oxidizer, aluminum fuel, iron oxide catalyst, polymer binder, and epoxy curing agent in the two solid rocket boosters result in the formation of a large cloud of hot, buoyant toxic exhaust gases near the ground level which subsequently rises and entrains into ambient air until the temperature and density of the cloud reaches an approximate equilibrium with ambient conditions. In this paper, toxic gas dispersion for various gases are simulated over the web for varying environmental conditions which is provided by rawinsonde data. The model simulates chemical concentration at ground level up to 10 miles (1 KM grids) in downrange up to an hour after launch. The ambient concentration of the gas dispersion and the deposition of toxic particles are used as inputs for a human health risk assessment model. The advantage of the present model is the accessibility and dissemination of model results to other NASA centers over the web. The model can be remotely operated and various scenarios can be analyzed.

Bardina, Jorge↗

Toxicity of Carbon Nanotubes and Its Implications for Occupational and Environmental Health

Carbon nanotubes (CNTs), which possess desirable electrical and mechanical properties, potentially have wide industrial applications. CNTs exist in two forms, single-wall (SW) and multi-wall (MW). There has been great concern that if CNTs enter the work environment as suspended respirable particulate matter (PM), they could pose an inhalation hazard. The results of recent rodent studies have collectively shown that CNTs can produce inflammation, epithelioid granulomas, fibrosis, and biochemical changes in the lungs. Studies in mice given equal amounts of test dusts showed that CNTs were more toxic than quartz and produced lesions that became progressively more pronounced. These results have led us to recommend that respirable CNT dust be considered a serious occupational health hazard, and that exposure limits be established in the expectation of expanded industrial applications. CNTs, which are totally insoluble and fibrous, would be expected to be more biopersistent than mineral fibers. Biopersistence is the key factor determining the long-term toxicity of mineral fibers and certainly of CNTs too. We have postulated that the electrical and fibrous properties of CNTs also play important roles in the toxicity of CNTs in the lungs. Recently, MWCNTs have been found in ultrafine PM aggregates in combustion streams of methane, propane, and natural-gas flames of typical stoves; indoor and outdoor fine (< 2.5 micron) PM samples were reported to contain significant fractions of MWCNTs. Environmental fine PM is mainly formed from combustion of fuels, and fine PM has been reported to be a major contributor to the induction of cardiopulmonary diseases by pollutants. Given that manufactured SWCNTs and/or MWCNTs have elicited pathological changes in the lungs and heart, we have postulated that exposure to combustion-generated MWCNTs in fine PM in the air may play a significant role in air pollution-related cardiopulmonary diseases. Therefore, CNTs from manufacturing and combustion sources in the environment could have adverse effects on human health.

Lam, Chiu-wing↗