Search NASA⌕ Search

SEARCH · Search NASA

Results for “TUBING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Dynamic Approach to Dependency Analysis in Human Reliability Analysis: Application in a Stream Generator Tube Rupture Scenario

Dependency analysis in human reliability analysis (HRA) is a method of adjusting the failure probability of a given action by considering the impact of the action preceding it. It plays a role in reasonably accounting for human actions in the context of probabilistic safety assessments (PSAs), preventing PSA results from being estimated too optimistically based on the HRA results. Nevertheless, the existing dependency methods present a couple of challenges in that the quantification approaches rarely explain the adjustment of human error probabilities (HEPs). For this reason, the authors’ previous research has pointed out challenges of the existing dependency approaches and conceptually, theoretically proposed a performance shaping factor (PSF)-based dynamic dependency analysis method for HRA in order to complement the existing dependency methods. The current paper explores the latest version of the method and guidance for applying it to a steam generator tube rupture (SGTR) scenario.

99 GENERAL AND MISCELLANEOUS↗

Heat-shrink plastic tubing seals joints in glass tubing

Small units of standard glass apparatus held together by short lengths of transparent heat-shrinkable polyolefin tubing. The tubing is shrunk over glass O-ring type connectors having O-rings but no lubricant.

Del Duca, B.↗

Influence of tube-entrance configuration on average heat-transfer coefficients and friction factors for air flowing in an Inconel tube

A heat-transfer investigation was conducted with air flowing through an electrically heated Inconel tube having either a long-approach or a right-angle-edge entrance, an inside diameter of 0.402 inch, and a length of 24 inches over a range of Reynolds numbers up to 375,000 and average inside-tube-wall temperatures up to 2000 degrees R. Good correlation of heat-transfer data was obtained for both entrances, which substantiates work previously reported. A fair correlation of friction data was obtained for both entrances. The entrance configuration had little effect on the average heat-transfer and friction coefficients.

HEAT-TRANSFER THEORY AND EXPERIMENT↗

Novel Low-Cost, Low-Power Miniature Thermionic Cathode Developed for Microwave/Millimeter Wave Tube and Cathode Ray Tube Applications

A low cost, small size and mass, low heater power, durable high-performance barium dispenser thermionic cathode has been developed that offers significant advancements in the design, manufacture, and performance of the electron sources used in vacuum electronic devices--such as microwave (and millimeter wave) traveling-wave tubes (TWT's)--and in display devices such as high-brightness, high-resolution cathode ray tubes (CRT's). The lower cathode heater power and the reduced size and mass of the new cathode are expected to be especially beneficial in TWT's for deep space communications, where future missions are requiring smaller spacecraft, higher data transfer rates (higher frequencies and radiofrequency output power), and greater electrical efficiency. Also expected to benefit are TWT's for commercial and government communication satellites, for both low and geosynchronous Earth orbit, with additional benefits offered by lower cost and potentially higher cathode current loading. A particularly important TWT application is in the microwave power module (MPM), which is a hybrid microwave (or millimeter wave) amplifier consisting of a low-noise solid state driver, a vacuum power booster (small TWT), and an electronic power conditioner integrated into a single compact package. The attributes of compactness and potentially high electrical efficiency make the MPM very attractive for many commercial and government (civilian and defense) applications in communication and radar systems. The MPM is already finding application in defense electronic systems and is under development by NASA for deep space communications. However, for the MPM to become competitive and commercially successful, a major reduction in cost must be achieved.

Wintucky, Edwin G.↗

Comparison of Different Ion Mobility Setups Using Poly (Ethylene Oxide) PEO Polymers: Drift Tube, TIMS, and T-Wave Comparison of Different Ion Mobility Setups Using Poly (Ethylene Oxide) PEO Polymers: Drift Tube, TIMS, and T-Wave

Over the years, polymer analyses using ion mobility-mass spectrometry (IM-MS) measurements have been performed on different ion mobility spectrometry (IMS) setups. In order to be able to compare literature data taken on different IM(-MS) instruments, ion heating and ion temperature evaluations have already been explored. Nevertheless, extrapolations to other analytes are difficult and thus straightforward same-sample instrument comparisons seem to be the only reliable way to make sure that the different IM(-MS) setups do not greatly change the gas-phase behavior. We used a large range of degrees of polymerization (DP) of poly(ethylene oxide) PEO homopolymers to measure IMS drift times on three different IM-MS setups: a homemade drift tube (DT), a trapped (TIMS), and a traveling wave (T-Wave) IMS setup. The drift time evolutions were followed for increasing polymer DPs (masses) and charge states, and they are found to be comparable and reproducible on the three instruments. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Styrene Thermal Decomposition and Its Reaction with Acetylene under Shock Tube Pyrolysis Conditions: an Experimental and Kinetic Modeling Study

Styrene is an important compound for polymer production and a key intermediate in gas-phase kinetics of polycyclic aromatic hydrocarbons (PAHs). For the first time, the pyrolysis of styrene with and without the presence of acetylene is investigated in a single-pulse shock tube coupled to gas chromatography and mass spectrometry. For each reaction system, quantitative speciation profiles are probed within the temperature range of 1100-1730 K, nominal pressure of 20 bar, and reaction duration of similar to 4 ms. A kinetic model is built to simulate the results. The model explains how styrene is consumed under high-pressure pyrolytic conditions, how the secondary chemistry of intermediate products affect subsequent PAH formation, and how acetylene addition alters the reaction pathways. Throughout the temperature range, styrene breakdown is dominated by the bimolecular interaction between styrene and hydrogen atom, which produces benzene+vinyl or phenyl and ethylene through the stabilization of 2-phenylethyl and its subsequent dissociation. As a result, large amounts of phenyl accumulate, which react with styrene to form C14H12 species while simultaneously releasing H atoms through addition/elimination reactions. The reactivity of fuel consumption is preserved by the regeneration of H atoms as chain carriers. Several C14H10 compounds are formed as a result of the following breakdown of the C14H12 isomers, particularly stilbene, 1,1-diphenyl ethylene, and 9-methyl-9H-fluorene. The presence of acetylene as a co-reactant with styrene allows the Hydrogen-Abstraction-Acetylene-Addition (HACA) pathway to proceed from phenyl radical to enhance the production of phenylacetylene at very low temperatures and acenaphthylene. This hinders the formation of C14H12 isomers, exclusive products from pure styrene dissociation by competing with the styrene+phenyl routes.

Kinetic Modeling↗

Image-converter tubes for lasers and lasers for image-converter tubes (operating experience of the Photoelectronics Department, GPI, RAS)

Work in the field of electron-optical diagnostics of laser-induced rapid processes performed for almost half a century at the Photoelectronics Department at the General Physics Institute, RAS, is summed up. New femtosecond image-converter tubes have been developed, which provide the time resolution no worse than 100 fs in the slit scan (streak) regime, and photoelectron guns have been built for time-resolved studies of electron diffraction. The results of recent studies on manifold (up to fifty-fold) compression of picosecond electron bunches in nonstationary focusing fields are demonstrated. (special issue devoted to the 25th anniversary of the a.m. prokhorov general physics institute)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A structural examination and collision cross section database for over 500 metabolites and xenobiotics using drift tube ion mobility spectrometry

The confident identification of metabolites and xenobiotics in biological and environmental studies is an analytical challenge due to their immense dynamic range, vast chemical space and structural diversity. Ion mobility spectrometry (IMS) is widely used for small molecule analyses since it can separate isomeric species and be easily coupled with front end separations and mass spectrometry for multidimensional characterizations. However, to date IMS metabolomic and exposomic studies have been limited by an inadequate number of accurate collision cross section (CCS) values for small molecules, causing features to be detected but not confidently identified. In this work, we utilized drift tube IMS (DTIMS) to directly measure CCS values for over 450 small molecules including primary metabolites, secondary metabolites and xenobiotics. Since DTIMS measurements do not need calibrates, they avoid calibration errors which can cause CCS accuracy problems and difficulties identifying structurally similar molecules. Furthermore, all measurements were performed in triplicate in both positive and negative polarities with nitrogen gas and seven different electric fields, so that relative standard deviations (RSD) could be assessed for each molecule and structural differences studied. The primary metabolites selected for the database are from key metabolism pathways such as glycolysis, the pentose phosphate pathway, and the tricarboxylic acid (TCA) cycle, while the secondary metabolites consist of classes such as terpenes and flavonoids, and the xenobiotics represent a range of molecules from antibiotics to polycyclic aromatic hydrocarbons. Different CCS trends were observed for several of the diverse small molecule classes, allowing insight in their separations and a possible why of classifying unknowns. This CCS database and structural information are freely available for download at http://panomics.pnnl.gov/metabolites/ with new molecules being added monthly.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Selected-ion flow tube temperature-dependent measurements for the reactions of O{sub 2}{sup +} with N atoms and N{sub 2}{sup +} with O atoms

The temperature variation of rate constants has been measured for the gas phase reactions of the oxycation O{sub 2}{sup +} with N atoms and of N{sub 2}{sup +} with O atoms from 120 to 400 K using a variable temperature-selected ion flow tube. Measured room temperature rate constants, 0.75 × 10{sup −10} cm{sup 3} s{sup −1} (±30%) for O{sub 2}{sup +} with N and 1.4 × 10{sup −10} cm{sup 3} s{sup −1} (±30%) for N{sub 2}{sup +} with O, are in agreement with previously reported values. A temperature dependence of T{sup −0.7(±0.3)} is observed for the O{sub 2}{sup +} + N reaction; however, the N{sub 2}{sup +} + O reaction is found to be independent of temperature. Calculations at varying levels of theory were used in tandem with experiments to evaluate likely pathways in potential energy surfaces for the reactions of concern.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗