Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tapes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Strong Adhesive Tape for Cold Environments

Strong tape remains sticky over wide temperature range. Strong tape for low temperatures consists of two layers of polyimide tape with layer of reinforcing mesh. Improved tape devised for repairs in space also finds use on Earth in polar regions and in superconducting applications. Tape retains adherence and strength at extreme temperatures, where conventional tapes fail.

Woods, T. G.↗

The ISEE-1 ULEWAT flux tape description

The ISEE-1 ULEWAT FLUX tapes of solar proton observations summarized over 1hr intervals are described. Three years of data fit onto one 1600 BPI 9-track magnetic tape. In making the tapes, corrections were made to the ULEWAT basic data tapes in order to, e.g., remove rate spikes and account for changes in instrument response, so that instrument fluxes can be calculated easily from the FLUX tapes without further consideration of instrument performance. Limitations and warnings about the use of the tapes are included.

Mason, G. M.↗

The ISEE-3 ULEWAT: Flux tape description and heavy ion fluxes 1978-1984

The ISEE ULEWAT FLUX tapes contain ULEWAT and ISEE pool tape data summarized over relatively long time intervals (1hr) in order to compact the data set into an easily usable size. (Roughly 3 years of data fit onto one 1600 BPI 9-track magnetic tape). In making the tapes, corrections were made to the ULEWAT basic data tapes in order to, remove rate spikes and account for changes in instrument response so that to a large extent instrument fluxes can be calculated easily from the FLUX tapes without further consideration of instrument performance.

Mason, G. M.↗

Integration of altitude and airspeed information into a primary flight display via moving-tape formats: Evaluation during random tracking task

A ground-based aircraft simulation study was conducted to determine the effects on pilot preference and performance of integrating airspeed and altitude information into an advanced electronic primary flight display via moving-tape (linear moving scale) formats. Several key issues relating to the implementation of moving-tape formats were examined in this study: tape centering, tape orientation, and trend information. The factor of centering refers to whether the tape was centered about the actual airspeed or altitude or about some other defined reference value. Tape orientation refers to whether the represented values are arranged in descending or ascending order. Two pilots participated in this study, with each performing 32 runs along seemingly random, previously unknown flight profiles. The data taken, analyzed, and presented consisted of path performance parameters, pilot-control inputs, and electrical brain response measurements.

Abbott, Terence S.↗

Magnetic-Tape Utilities Computer Program

Fast Magnetic Tape Utility package (MTUTILS/TUTIL) is collection of subroutines for DEC VAX/VMS computers designed to simplify access to magnetic-tape drives. Routines use standard FORTRAN argument binding and simpler than corresponding system service calls. Two sets of routines: one enables basic tape operation; other certain operations performed on sequence of tape drives. Enables manipulation of sets of data too large to be held on single magnetic tape. Program user-friendly, menu-driven employing MTUTILS package to process tapes interactively.

Olson, N. E.↗

Mass optical storage-tape (MOST)

In today's large mainframe and supercomputer environment there exists a continuous demand for increased performance in digital storage systems. The user need for near-line storage capacity is currently doubling every four years. In addition to higher capacity, a desire exists for higher data transfer rates, and longer term database archivability, at lower, and lower cost. Each component of this quartet of demands appears to be insatiable. Magnetic tape technology presently dominates the digital mass storage markets, but the continuous growth of requirements is drawing attention to the limitations of the technology as an archival mass storage medium. The lowest cost option currently available for long term data storage is to use magnetic tape, although it is not well suited to meeting the need for many tens of years of reliable storage. Today, the majority of magnetic tape mass storage systems are based on the IBM 3480/3490 (or compatible) tape drives. These drives offer only moderate transfer rates and relatively small increments of storage, both of which create a logistics problem due to the large numbers of cartridges necessary in a typical system and the time taken to transfer data. Both higher cartridge capacity and data transfer rates are available in some helical scan magnetic tape systems; however, these command a substantially higher price, exacerbating the cost problem, and are not compatible with most installed systems or tape databases.

Oakley, William S.↗

Recording and wear characteristics of 4 and 8 mm helical scan tapes

Performance data of media on helical scan tape systems (4 and 8 mm) is presented and various types of media are compared. All measurements were performed on a standard MediaLogic model ML4500 Tape Evaluator System with a Flash Converter option for time based measurements. The 8 mm tapes are tested on an Exabyte 8200 drive and 4 mm tapes on an Archive Python drive; in both cases, the head transformer is directly connected to a Media Logic Read/Write circuit and test electronics. The drive functions only as a tape transport and its data recover circuits are not used. Signal to Noise, PW 50, Peak Shift and Wear Test data is used to compare the performance of MP (metal particle), BaFe, and metal evaporate (ME). ME tape is the clear winner in magnetic performance but its susceptibility to wear and corrosion, make it less than ideal for data storage.

Peter, Klaus J.↗

Damage tolerance of pressurized graphite/epoxy tape cylinders under uniaxial and biaxial loading

The damage tolerance behavior of internally pressurized, axially slit, graphite/epoxy tape cylinders was investigated. Specifically, the effects of axial stress, structural anisotropy, and subcritical damage were considered. In addition, the limitations of a methodology which uses coupon fracture data to predict cylinder failure were explored. This predictive methodology was previously shown to be valid for quasi-isotropic fabric and tape cylinders but invalid for structurally anisotropic (+/-45/90)(sub s) and (+/-45/0)(sub s) cylinders. The effects of axial stress and structural anisotropy were assessed by testing tape cylinders with (90/0/+/-45)(sub s), (+/-45/90)(sub s), and (+/-45/0)(sub s) layups in a uniaxial test apparatus, specially designed and built for this work, and comparing the results to previous tests conducted in biaxial loading. Structural anisotropy effects were also investigated by testing cylinders with the quasi-isotropic (0/+/-45/90)(sub s) layup which is a stacking sequence variation of the previously tested (90/0/+/-45)(sub s) layup with higher D(sub 16) and D(sub 26) terms but comparable D(sub 16) and D(sub 26) to D(sub 11) ratios. All cylinders tested and used for comparison are made from AS4/3501-6 graphite/epoxy tape and have a diameter of 305 mm. Cylinder slit lengths range from 12.7 to 50.8 mm. Failure pressures are lower for the uniaxially loaded cylinders in all cases. The smallest percent failure pressure decreases are observed for the (+/-45/90)(sub s) cylinders, while the greatest such decreases are observed for the (+/-45/0)(sub s) cylinders. The relative effects of the axial stress on the cylinder failure pressures do not correlate with the degree of structural coupling. The predictive methodology is not applicable for uniaxially loaded (+/-45/90)(sub s) and (+/-45/0)(sub s) cylinders, may be applicable for uniaxially loaded (90/0/+/-45)(sub s) cylinders, and is applicable for the biaxially loaded (90/0/+/-45)(sub s) and (0/+/-45/90)(sub s) cylinders. This indicates that the ratios of D(sub 16) and D(sub 26) to D(sub 11), as opposed to the absolute magnitudes of D(sub 16) and D(sub 26), may be important in the failure of these cylinders and in the applicability of the methodology. Discontinuities observed in the slit tip hoop strains for all the cylinders tested indicate that subcritical damage can play an important role in the failure of tape cylinders. This role varies with layup and loading condition and is likely coupled to the effects of structural anisotropy. Biaxial failure pressures may exceed the uniaxial values because the axial stress contributes to the formation of 0 deg ply splitting (accompanied by delamination) or similar stress-mitigating subcritical damage. The failure behavior of similar cylinders can also vary as a result of differences in the role of subcritical damage as observed for the case of a biaxially loaded (90/0/+/-45)(sub s) cylinder with a 12.7 mm slit. For this case, the methodology is valid when the initial coupon and cylinder fracture modes agree. However, the methodology underpredicts the failure pressure of the cylinder when a circumferential fracture path, suggestive of a 0 deg ply split, occurs at one slit tip. Thus, the failure behavior of some tape cylinders may be highly sensitive to the initial subcritical damage mechanism. Finite element analyses are recommended to determine how structural anisotropy and axial stress modify the slit tip stress states in cylinders from those found in flat plates since similarity of these stress states is a fundamental assumption of the current predictive methodology.

Priest, Stacy Marie↗

Certification of ICI 1012 optical data storage tape

ICI has developed a unique and novel method of certifying a Terabyte optical tape. The tape quality is guaranteed as a statistical upper limit on the probability of uncorrectable errors. This is called the Corrected Byte Error Rate or CBER. We developed this probabilistic method because of two reasons why error rate cannot be measured directly. Firstly, written data is indelible, so one cannot employ write/read tests such as used for magnetic tape. Secondly, the anticipated error rates need impractically large samples to measure accurately. For example, a rate of 1E-12 implies only one byte in error per tape. The archivability of ICI 1012 Data Storage Tape in general is well characterized and understood. Nevertheless, customers expect performance guarantees to be supported by test results on individual tapes. In particular, they need assurance that data is retrievable after decades in archive. This paper describes the mathematical basis, measurement apparatus and applicability of the certification method.

Howell, J. M.↗

One-step Tape Casting of Composites via Slurry on Fiber

A process by which metal matrix composites can be made was presented. The process involves putting a powder slurry on fibers to make a precursor green tape. These green tapes are cut, stacked and hot pressed to form the fully dense composite. A computer program was presented which enables complete quantification and control of the process. Once some easily obtained properties of the slurry and its behavior are determined (such as the shrinkage from the wet to green state, and the density of the green tape) modification of the fiber spacing and blade height give the maker precise control of fiber volume fraction, and fiber architecture in the composite. The process was shown to be accurate and flexible through the production of a wide variety of volume fraction fiber composites made from a wide variety of fibers and powders. The most time consuming step of the tape casting process (other than hot pressing) was winding the fiber on the drum. The tape casting techniques developed resulted in high quality metal matrix composites, with ultimate tensile strength in the range of 215 ksi (1477 MPa), a strain at failure of 1.15 percent, and in fatigue at room temperature 0 to 120 ksi, n = 0.3 Hz, a 4-ply Ti-24Al-11Nb/SCS-6, 32 vol% fiber tape cast composite lasted 202,205 cycles with a maximum strain on the 100th cycle of 0.43 percent.

deGroh, Henry C., III↗

Dry Process for Making Polyimide/ Carbon-and-Boron-Fiber Tape

A dry process has been invented as an improved means of manufacturing composite prepreg tapes that consist of high-temperature thermoplastic polyimide resin matrices reinforced with carbon and boron fibers. Such tapes are used (especially in the aircraft industry) to fabricate strong, lightweight composite-material structural components. The inclusion of boron fibers results in compression strengths greater than can be achieved by use of carbon fibers alone. The present dry process is intended to enable the manufacture of prepreg tapes (1) that contain little or no solvent; (2) that have the desired dimensions, fiber areal weight, and resin content; and (3) in which all of the fibers are adequately wetted by resin and the boron fibers are fully encapsulated and evenly dispersed. Prepreg tapes must have these properties to be useable in the manufacture of high-quality composites by automated tape placement. The elimination of solvent and the use of automated tape placement would reduce the overall costs of manufacturing.

Belvin, Harry L.↗

Simulations of Heat Transfer Using Tight-Fitting Twisted Tape Inserts for First Wall Cooling in Molten Salt Breeder Blankets

One of the major components in fusion energy systems is the fusion blanket, which has a vacuum vessel to contain the plasma. As part of the fusion blanket/vacuum vessel, the first wall and plasma-facing components require sufficient cooling to prevent material degradation during operation from the superheated plasma. Most fusion blanket concepts involve first wall and divertor coolant channels with heat transfer enhancements (HTEs) that are intended to withstand the incident high heat fluxes of 1 to 5 MW/m 2 . Twisted tape inserts are a proposed HTE that have been investigated previously for first wall cooling and monoblock divertor cooling channels and in other nonfusion heat transfer components. By inserting twisted tapes into straight pipes, the amount of turbulence in the system can be increased at lower Reynolds numbers by swirling the flow. This results in better heat transfer characteristics with marginal increases in frictional pressure losses. In particular, simulations of high-Prandtl-number fluids such as the proposed molten salt FLiBe in twisted tapes, which is prototypic to liquid immersion blankets, have not been previously explored. Here, in this study, we simulate various Prandtl numbers in pipes with twisted tape inserts using large eddy simulations to determine the effects of increasing Prandtl numbers on heat transfer performance. The quantities of particular interest are the Nusselt number and the friction factor, which were recovered using data reduction techniques to determine impacts on heat transfer and pressure losses. This work serves as a starting point for determining the feasibility of twisted tape inserts for liquid immersion blanket concepts.

LES↗

Scale Up of High-Performance REBCO Tapes in a Pilot-Scale Advanced MOCVD Tool With In-Line 2D-XRD System

We have reported the development of an Advanced Metal-Organic Chemical Vapor Deposition (AMOCVD) method featuring ohmic heating of the substrate for REBCO film growth, direct tape temperature monitoring, and laminar precursor flow. This A-MOCVD method has been used to fabricate 4 – 5 m thick film REBCO tapes with record high performance: critical currents exceeding 8700 A/12 mm at 30 K, 3 T; and engineering current density of 5200 A/mm 2 at 4.2 K, 15 T. Recently, we constructed a pilot-scale reel-to-reel A-MOCVD system to scale up the technology to long tapes. Preliminary batches of tapes exhibit consistent performance and good uniformity along the length. An in-line 2D X-ray Diffraction (XRD) system has been integrated into the pilot A-MOCVD tool to monitor the REBCO texture and composition, RE 2 O 3 content, and the dimensions of BaMO 3 (BMO, M=Zr,Hf) nanorods that act as artificial pinning centers. Specifically, the streaking angle between REBCO (103) and BZO (101) has been found to correlate well with (Ba+M)/Cu of the film, lift factor in critical current over a range of temperatures and magnetic fields, and the size of the BMO nanorods. Furthermore, the in-line 2D-XRD is expected to serve as a valuable quality measuring tool supporting realtime feedback control for the process to yield uniform and consistent manufacturing of high performance REBCO tapes by Advanced MOCVD.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Graphene K‐Tape Meshes for Densely Distributed Human Motion Monitoring

Abstract Wearable sensors that measure parameters associated with physical activity and bodily motions have been regarded as an indispensable tool for assessing personal wellness. Recent advances in nanocomposite strain sensors have been successfully used for monitoring skin strains and other strain‐derived physiological parameters. This study complements the existing body of work and presents a flexible, self‐adhering, fabric‐based wearable sensor for measuring skin strains and human motions. Graphene nanosheet thin films are directly spray‐coated onto kinesiology tape (K‐Tape) to obtain a self‐adhering strain sensor of high sensitivity and linearity. Their stable sensing performance and high repeatability are verified, while human subject tests confirm that they adequately capture muscle engagement during functional movements. In addition, densely distributed strain monitoring can be achieved using an electrical impedance tomography measurement approach and algorithm. Spatial strain sensing is successfully demonstrated using a single strip of piezoresistive K‐Tape, as well as when a K‐Tape network or mesh pattern is formed. The results show promise for using graphene K‐Tape meshes to measure how specific major muscle groups engage during different physical activities.

Lin, Yun‐An↗

Improving Performance of Tape Restore Request Scheduling in the Storage System dCache

Given the anticipated increase in the amount of scientific data, it is widely accepted that primarily disk based storage will become prohibitively expensive. Tape based storage, on the other hand, provides a viable and affordable solution for the ever increasing demand for storage space. Coupled with a disk caching layer that temporarily holds a small fraction of the total data volume to allow for low latency access, it turns tape based systems into active archival storage (write once, read many) that imposes additional demands on data flow optimization compared to traditional backup setups (write once, read never). In order to preserve the lifetime of tapes and minimize the inherently higher access latency, different tape usage strategies are being evaluated. As an important disk storage system for scientific data that transparently handles tape access, dCache is making efforts to evaluate its recall optimization potential and is introducing a proof-of-concept, high-level stage request scheduling component within its SRM implementation.

Morschel, Lea↗

Optimization of Lithium Content and Sintering Additives in Tape Cast Lithium Garnet Electrolyte Sheets

The lithium garnet (LLZO) remains one of the most promising electrolyte materials for producing solid state batteries. Tape casting is one method for producing the thin ceramic electrolyte layer required for a high-performance solid state battery. Processing of LLZO is complicated by several factors including lithium volatilization, abnormal grain growth and phase instability. Many of these issues are exacerbated in tape cast sheets by the sheets' higher surface area to volume ratio, when compared to pellet processing methods. Here, we report on an environmentally friendly aqueous tape casting process for LLZO using methylcellulose as a binder and compare final sheet properties to other, solvent-based, options. Solids loading, binder content, dispersant composition, and wetting agent type are varied to improve ease of casting and enhance properties of the as-cast tape. Lithium content in sintered LLZO sheets is controlled by the inclusion of excess Li 2 CO 3 as lithium source in the ceramic tape itself and by a novel method of producing a lithium-saturated furnace atmosphere. Sintering time and temperature are optimized, and rapid thermal processing is investigated as a method of reducing lithium loss. Al 2 O 3 and MgO are examined for use as sintering additives. Characterization of LLZO sheets is performed with XRD, EIS and SEM. Li 2 CO 3 and sintering additive levels are optimized for ionic conductivity and density. The optimization effort improved the conductivity and density of 100µm thick sintered sheets to greater than 3x10 -4 S/cm conductivity and 90% density.

36 MATERIALS SCIENCE↗

Feasibility model of a high reliability five-year tape transport, Volume 1

The development, performance, and test results for the spaceborne magnetic tape transport are discussed. An analytical model of the tape transport was used to optimize its conceptual design. Each of the subsystems was subjected to reliability analyses which included structural integrity, maintenance of system performance within acceptable bounds, and avoidance of fatigue failure. These subsystems were also compared with each other in order to evaluate reliability characteristics. The transport uses no mechanical couplings. Four drive motors, one for each reel and one for each of two capstans, are used in a differential mode. There are two hybrid, spherical, cone tapered-crown rollers for tape guidance. Storage of the magnetic tape is provided by a reel assembly which includes the reel, a reel support structure and bearings, dust seals, and a dc drive motor. A summary of transport test results on tape guidance, flutter, and skew is provided.

Eshleman, R. L.↗

FGGE/ERBZ tape specification and shipping letter description

The FGGE/ERBZ tape contains 5 parameters which are extracted and reformatted from the Nimbus-7 ERB Zonal Means Tape. There are three types of files on a FGGE/ERBZ tape: a tape header file, and data files. Physical characteristics, gross format, and file specifications are given. A sample tape check/document printout (shipping letter) is included.

Han, D.↗