Search NASA⌕ Search

SEARCH · Search NASA

Results for “Technology Performance Exchange”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Stirling Air Conditioner for Compact Cooling

BEETIT Project: Infinia is developing a compact air conditioner that uses an unconventional high efficient Stirling cycle system (vs. conventional vapor compression systems) to produce cool air that is energy efficient and does not rely on polluting refrigerants. The Stirling cycle system is a type of air conditioning system that uses a motor with a piston to remove heat to the outside atmosphere using a gas refrigerant. To date, Stirling systems have been expensive and have not had the right kind of heat exchanger to help cool air efficiently. Infinia is using chip cooling technology from the computer industry to make improvements to the heat exchanger and improve system performance. Infinia’s air conditioner uses helium gas as refrigerant, an environmentally benign gas that does not react with other chemicals and does not burn. Infinia’s improvements to the Stirling cycle system will enable the cost-effective mass production of high-efficiency air conditioners that use no polluting refrigerants.

ARPA-E↗

Effect of reacting gas flowrates and hydration on the carbonation of anion exchange membrane fuel cells in the presence of CO 2

Anion exchange membrane fuel cells (AEMFCs) have been widely touted as a low-cost alternative to existing proton exchange membrane fuel cells. However, one of the limitations of this technology has been the severe performance penalty related to the introduction of CO 2 to the cell – typically in the air cathode feed. Introduction of CO 2 into AEMFCs results in cell carbonation, which imparts thermodynamic, kinetic and Ohmic overpotentials that can add up to hundreds of millivolts. Therefore, it is important to find strategies and operational protocols for AEMFCs that minimize these overpotentials. In this paper, we reserach the impacts of the anode and cathode flowrate, as well as the cell hydration level, on the extent of cell carbonation and cell polarization. Key findings include: (1) decreasing the cathode flowrate generally decreases the total CO 2 -related voltage loss while changing the anode flowrate has a minimal effect; (2) increasing cell hydration helps to mitigate the performance loss in the presence of CO 2 ; and (3) operational combinations are found that significantly reduce the CO 2 penalty compared to the present literature.

25 ENERGY STORAGE↗

Analysis of a Fluidized-Bed Particle/Supercritical-CO2 Heat Exchanger in a Concentrating Solar Power System

Concentrating solar power (CSP) development has focused on increasing the energy conversion efficiency and lowering the capital cost. To improve performance, CSP research is moving to high-temperature and high-efficiency designs. One technology approach is to use inexpensive, high-temperature heat transfer fluids and storage, integrated with a high-efficiency power cycle such as the supercritical carbon dioxide (sCO 2 ) Brayton power cycle. The sCO 2 Brayton power cycle has strong potential to achieve performance targets of 50% thermal-to-electric efficiency and dry cooling at an ambient temperature of up to 40 °C and to reduce the cost of power generation. Solid particles have been proposed as a possible high-temperature heat transfer or storage medium that is inexpensive and stable at high temperatures above 1000 °C. The particle/sCO 2 heat exchanger (HX) provides a connection between the particles and sCO 2 fluid in emerging sCO 2 power cycles. This article presents heat transfer modeling to analyze the particle/sCO 2 HX design and assess design tradeoffs including the HX cost. The heat transfer process was modeled based on a particle/sCO 2 counterflow configuration, and empirical heat transfer correlations for the fluidized bed and sCO 2 were used to calculate heat transfer area and estimate the HX cost. A computational fluid dynamics simulation was applied to characterize particle distribution and fluidization. This article shows a path to achieve the cost and performance objectives for a particle/sCO 2 HX design by using fluidized-bed technology.

14 SOLAR ENERGY↗

Linking structure to performance: Characterization of porous transport layers for high-pressure water electrolysis

Proton exchange membrane (PEM) water electrolysis is a promising technology to produce cost-efficient hydrogen. PEM electrolyzers offer a large current density range and the ability to operate at differential pressure which can be used to minimize both capital and operational expenditures. However, directly producing pressurized hydrogen at the cathode results in pushing the membrane against the anode porous transport layer (PTL). This can lead to detrimental effects, such as membrane deformation or ruptures, which depend on membrane properties as well as PTL material properties such as pore size, structure, and morphology. In this work, a range of sinter and felt-based commercial PTLs are evaluated for their contributions to the cell's electrochemical and H 2 crossover performance at cathode pressures up to 30 bar. X-ray tomography and post-operando optical microscopy are used to assess the morphology of the PTLs, and the PTL induced deformation experienced by the catalyst coated membrane (CCM), respectively. PTL samples with lower porosity were found to reduce both the cell voltage and the amount of H 2 permeating from the cathode to the anode exhaust, which was ascribed to improved catalyst layer contact and reduced membrane deformation, respectively. The best performing PTLs improved electrolyzer efficiency by ~1.5 kWh/kg H2 . Specifically, 1 kWh/kg H2 was gained due to reducing membrane deformation and decreasing H 2 crossover. The remainder 0.5 kWh/kg H2 were achieved by improving the electrical contact at the electrode/PTL interface which decreased cell voltage.

08 HYDROGEN↗

Performance Evaluation and Benchmarking of Intelligent Systems

To design and develop capable, dependable, and affordable intelligent systems, their performance must be measurable. Scientific methodologies for standardization and benchmarking are crucial for quantitatively evaluating the performance of emerging robotic and intelligent systems technologies. There is currently no accepted standard for quantitatively measuring the performance of these systems against user-defined requirements; and furthermore, there is no consensus on what objective evaluation procedures need to be followed to understand the performance of these systems. The lack of reproducible and repeatable test methods has precluded researchers working towards a common goal from exchanging and communicating results, inter-comparing system performance, and leveraging previous work that could otherwise avoid duplication and expedite technology transfer. Currently, this lack of cohesion in the community hinders progress in many domains, such as manufacturing, service, healthcare, and security. By providing the research community with access to standardized tools, reference data sets, and open source libraries of solutions, researchers and consumers will be able to evaluate the cost and benefits associated with intelligent systems and associated technologies. In this vein, the edited book volume addresses performance evaluation and metrics for intelligent systems, in general, while emphasizing the need and solutions for standardized methods. To the knowledge of the editors, there is not a single book on the market that is solely dedicated to the subject of performance evaluation and benchmarking of intelligent systems. Even books that address this topic do so only marginally or are out of date. The research work presented in this volume fills this void by drawing from the experiences and insights of experts gained both through theoretical development and practical implementation of intelligent systems in a variety of diverse application domains. The book presents a detailed and coherent picture of state-of-the-art, recent developments, and further research areas in intelligent systems.

42 ENGINEERING↗

Demonstration of Electrochemically-Driven CO 2 Separation Using Hydroxide Exchange Membranes

Hydroxide exchange membrane fuel cells (HEMFCs) are a potentially lower-cost hydrogen fuel cell technology; however, ambient levels of CO 2 in air significantly reduce HEMFCs’ performance. In this work, we demonstrate an electrochemically-driven CO 2 separator (EDCS) which can be used to remove ambient levels of CO 2 from air upstream of the HEMFC stack in fuel cell vehicles, protecting it from CO 2 -related performance losses. The EDCS operating window was explored for current density, anode flow, and cathode flow with respect to its impact on CO 2 separation performance. Additionally, gas-phase mass transport was improved by selecting flow fields and gas diffusion layers conducive to the EDCS operating regime. The use of a carbon-ionomer interlayer at the cathode was explored and improved CO 2 removal performance from 77.7% to 98.2% at 20 mA cm −2 . An analytical, 1-D model is used to explain the experimental observations and design improvements. A single-cell, 25 cm 2 EDCS using the aforementioned improved design demonstrated greater than 98% CO 2 removal at a cathode flow rate of 1300 sccm for 100 h with 2.7% hydrogen stack consumption.

Matz, Stephanie↗

Atomically dispersed metal–nitrogen–carbon catalysts for fuel cells: advances in catalyst design, electrode performance, and durability improvement

The urgent need to address the high-cost issue of proton-exchange membrane fuel cell (PEMFC) technologies, particularly for transportation applications, drives the development of simultaneously highly active and durable platinum group metal-free (PGM-free) catalysts and electrodes. The past decade has witnessed remarkable progress in exploring PGM-free cathode catalysts for the oxygen reduction reaction (ORR) to overcome sluggish kinetics and catalyst instability in acids. Among others, scientists have identified the newly emerging atomically dispersed transition metal (M: Fe, Co, or/and Mn) and nitrogen co-doped carbon (M–N–C) catalysts as the most promising alternative to PGM catalysts. Here, we provide a comprehensive review of significant breakthroughs, remaining challenges, and perspectives regarding the M–N–C catalysts in terms of catalyst activity, stability, and membrane electrode assembly (MEA) performance. A variety of novel synthetic strategies demonstrated effectiveness in improving intrinsic activity, increasing active site density, and attaining optimal porous structures of catalysts. Rationally designing and engineering the coordination environment of single metal MN x sites and their local structures are crucial for enhancing intrinsic activity. Increasing the site density relies on the innovative strategies of restricting the migration and agglomeration of single metal sites into metallic clusters. Relevant understandings provide the correlations among the nature of active sites, nanostructures, and catalytic activity of M–N–C catalysts at the atomic scale through a combination of experimentation and theory. Current knowledge of the transferring catalytic properties of M–N–C catalysts to MEA performance is limited. Rationally designing morphologic features of M–N–C catalysts play a vital role in boosting electrode performance through exposing more accessible active sites, realizing uniform ionomer distribution, and facilitating mass/proton transports. We outline future research directions concerning the comprehensive evaluation of M–N–C catalysts in MEAs. The most considerable challenge of current M–N–C catalysts is the unsatisfied stability and rapid performance degradation in MEAs. Therefore, we further discuss practical methods and strategies to mitigate catalyst and electrode degradation, which is fundamentally essential to make M–N–C catalysts viable in PEMFC technologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiscale Porous High-temperature Heat Exchanger Using Ceramic Co-extrusion

In this project, our MIT, Purdue, and GE team aims to design, model, fabricate, and test a novel high temperature, compact, and durable ceramic heat exchanger to be operated under high temperature and pressure conditions for aerospace applications. Our approach is grounded in introducing multiscale porosity, i.e., centimeter-scale channels embedded with micrometer-scale channels, into the ceramic heat exchanger to significantly improve its heat transfer performance and mechanical strength while maintaining minimal pressure losses. We first developed high-fidelity thermal-fluid-mechanical model capable of precisely capturing the heat transfer rate, temperature profile, pressure drop, and mechanical stress throughout the entire heat exchanger design. Guided by our model, we identified the optimal design parameters for the SiC heat exchanger body and manifolds. Then, we established a completed fabrication procedure to create multiscale features in the ceramic heat exchanger, including co-extrusion, lamination, burnout, and sintering. We fabricated multiple heat exchanger bodies consisting of 6 × 6 and 3 × 3 centimeter-scale channels where each individual centimeter-scale channel comprises 625 crack-free microchannels with 90 μm × 90 μm opening. Owing to the multiscale features, our fabricated heat exchanger bodies exhibited desirable mechanical strength with 156 MPa flexural strength under 1300 Celsius degree. Despite the demonstrated highly tailorable microscopic features and superior mechanical strength, we identified delamination due to the complex interaction among ceramic, polymer, and gas species can be a critical challenge to create fully defect-free heat exchanger, which requires further fundamental investigations in future works. To test the heat exchanger performance, we constructed a high-temperature and high-pressure experimental apparatus that can be safely operated under 400 Celsius degree and 4 bar. With insights gained from mechanistic modeling, material development, and detailed characterization, a cost model was finally developed to understand the market potential of the developed technology, where a cost of $43,000 Celsius degree/kW was envisioned. This project developed a transformative approach to high-performance heat exchanger design. The thermal-fluid-mechanical design approach developed in this project can serve as a generic tool to guide the design of various heat-exchangers operated under high-temperature and high-pressure conditions. The material fabrication approach established in this project can be a useful guide for ceramic processing at extreme length scales.

42 ENGINEERING↗

Guest Molecule Exchange Kinetics for the 2012 Ignik Sikumi Gas Hydrate Field Trial

A commercially viable technology for producing methane from natural gas hydrate reservoirs remains elusive. Short-term depressurization field tests have demonstrated the potential for producing natural gas via dissociation of the clathrate structure, but the long-term performance of the depressurization technology ultimately requires a heat source to sustain the dissociation. A decade of laboratory experiments and theoretical studies have demonstrated the exchange of pure CO2 and N2-CO2 mixtures with CH4 in sI gas hydrates, yielding critical information about molecular mechanisms, recoveries, and exchange kinetics. Findings indicated the potential for producing natural gas with little to no production of water and rapid exchange kinetics, generating sufficient interest in the guest-molecule exchange technology for a field test. In 2012 the U.S. DOE/NETL, ConocoPhillips Company, and Japan Oil, Gas and Metals National Corporation jointly sponsored the first field trial of injecting a mixture of N2-CO2 into a CH4-hydrate bearing formation beneath the permafrost on the Alaska North Slope. Known as the Ignik Sikumi #1 Gas Hydrate Field Trial, this experiment involved three stages: 1) the injection of a N2-CO2 mixture into a targeted hydrate-bearing layer, 2) a 4-day pressurized soaking period, and 3) a sustained depressurization and fluid production period. Data collected during the three stages of the field trial were made available after an extensive quality check. These data included continuous temperature and pressure logs, injected and recovered fluid compositions and volumes. The Ignik Sikumi #1 data set is extensive, but contains no direct evidence of the guest-molecule exchange process. This investigation is directed at using numerical simulation to provide an interpretation of the collected data. A numerical simulator, STOMP-HYDT-KE, was recently completed that solves conservation equations for energy, water, mobile fluid guest molecules, and hydrate guest molecules, for up to three gas hydrate guest molecules: CH4, CO2, and N2. The independent tracking of mobile fluid and hydrate guest molecules allows for the kinetic exchange of guest molecules between the mobile fluids and hydrate. The particular interest of this numerical investigation is to determine whether kinetic exchange parameters, determined from laboratory-scale experiments, are directly applicable to interpreting the Ignik Sikumi #1 data.

Alaska North Slope↗

CIRCULATING MOVING BED COMBUSTION PROOF OF CONCEPT

Circulating Moving Bed (CMB) combustion technology has its roots in traditional circulating fluidized bed technology and involves a novel method of solid fuel combustion and heat transfer. CMB technology represents a step change in improved performance and cost relative to conventional PC and FBC boilers. The CMB heat exchanger preheats the energy cycle working fluid, steam or air, to the high temperature levels required in systems for advanced power generation. Unique features of the CMB are the reduction of the heat transfer surfaces by about 60% as a result of the enhanced heat transfer rates, flexibility of operation, and about 30% lower cost over existing technology. The CMB Phase I project ran from July 2001 through March 2003. Its objective was to continue development of the CMB technology with a series of proof of concept tests. The tests were conducted at a scale that provided design data for scale up to a demonstration plant. These objectives were met by conducting a series of experiments in ALSTOM Power’s Multi-use Test Facility (MTF). The MTF was modified to operate under CMB conditions of commercial interest. The objective of the tests were to evaluate gas-to-solids heat transfer in the upper furnace, assess agglomeration in the high temperature CMB bubbling bed, and evaluate solids-to-tube heat transfer in the moving bed heat exchanger. The Phase I program results showed that there are still some significant technical uncertainties that needed to be resolved before the technology can be confidently scaled up for a successful demonstration plant design. Work remained in three primary areas: • scale up of gas to solid heat transfer • high temperature finned surface design • the overall requirements of mechanical and process design. The CMB Phase II workscope built upon the results of Phase I and specifically addressed the remaining technical uncertainties. It included a scaled MTF heat transfer test to provide the necessary data to scale up gas-to-solids heat transfer. A stress test rig was built and tested to provide validation data for a stress model needed to support high temperature finned surface design. Additional cold flow model tests and MTF tests were conducted to address mechanical and process design issues. This information was then used to design and cost a commercial CMB design concept. Finally, the MBHE was reconfigured into a slice arrangement and tested for an extended duration at a commercial CFB plant.

42 ENGINEERING↗

Effect of cell compression on the performance and the structure of proton exchange membrane water electrolyzer (PEMWE) assembly

Here, in the field of water electrolysis, the proton exchange membrane water electrolyzer (PEMWE) is currently the most advanced technology for producing hydrogen without emitting CO 2 . Although PEMWE plants are already in operation, further research is needed to improve cell efficiency and reduce the use of rare materials, such as iridium oxide catalysts for the oxygen evolution reaction (OER). One of the main causes of performance loss in PEMWE is the relatively low electric conductivity of the porous transport layer (PTL) and of the anode catalyst layer, which results in ohmic losses and low catalyst utilization during high current density operation. The objective of this study is to investigate how optimization of the PTL and electrode interface can increase the cell performance. To this end, we tested different cell assemblies using fibrous and sintered PTLs, decreasing membrane thickness, reducing iridium loading, and inserting a microporous layer to increase contact surface area. Electrochemical characterization of each cell configuration was systematically performed at various compression levels as the pressure is a crucial parameter influencing the electrode/PTL contact area. In parallel, X-ray microcomputed tomography (micro-CT) was employed to investigate the effects of cell hydration and compression on the structure of PEMWE components. This study combining electrochemistry and micro-CT imaging presents how optimizing the electrode/PTL contact surface area, minimizes ohmic losses, and enables PEMWE operation with low iridium loading at high current densities.

Catalyst - PTL interface↗

Laboratory Evaluation of Energy Recovery Ventilators

Over the years, building scientists have characterized the relationship between building airtightness, exhaust-only appliances airflows, and building depressurization. Now, as the use of deep retrofit measures and new construction practices is growing to realize lower infiltration levels in increasingly tighter envelopes, performance issues can arise with the operation of exhaust-only appliances in a depressurized home. As the depressurization levels climb in tighter homes, many of these exhaust-only appliances see their rated airflows reduced and other related performance issues arise as a result. If sufficiently depressurized, atmospherically vented combustion appliances that may be present in the home can backdraft as well. Furthermore, when exhaust-only appliances operate and the tight home becomes depressurized, water vapor intrusion from outdoors can raise additional issues of mold in the building envelope in more humid climates. The use of energy recovery ventilators (ERVs) in tight homes in mixed-humid and hot-humid climates is already practiced. Unbalancing the ERV by reducing exhaust airflows can provide a means to supply makeup air and reduce the level of home depressurization to mitigate these issues, helping to realize the rated performance of the exhaust-only appliances, achieve safe operation of atmospherically vented combustion, provide the necessary level of fresh ventilation air, and/or improve envelope durability. The unbalanced operation of the ERV to address depressurization can obviously result in unintended consequences in other areas, such as further loss of humidity control in homes in more humid climates. In such tight home scenarios, it is expected that ERVs will operate a substantial amount of time in unbalanced mode with much higher supply than exhaust airflows. Although ERV design performance under balanced flow conditions is well documented, there is no information in the public domain that empirically establishes the effect of unbalanced flow on sensible and latent exchange, especially in the now dominant membrane-type ERV used in residential applications. Therefore, in this task, Gas Technology Institute (GTI) focused on a laboratory evaluation of the unbalanced flow (lowered exhaust airflow) performance of the RenewAire model EV 200, membrane-type ERV delivering 200 standard cubic feet per minute (SCFM) of supply air. The conducted tests show significant variation in ERV effectiveness at different levels of unbalanced air flows. Keeping supply airflow constant and lowering exhaust airflow increases effectiveness of both latent and sensible heat exchange. However, the increased effectiveness is accompanied by reduced capacity for load removal from the supply air, resulting in increased load to the conditioned space. Under decreasing exhaust airflow conditions, sensible load effectiveness exceeded a value of 1 at two sets of testing conditions. This was a result of the temperature rise of the supply air passing through the ERV augmented by the effect of motor heat gain, cross leakage heat gain, and casing heat gain. Consequently, measured sensible effectiveness must be qualified as the so-called Apparent Sensible Effectiveness of the ERV unit (the term used in the Canadian Standards Association C439 standard for testing ERVs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of model parameters in MFiX particle-in-cell approach

The limitations in numerical treatment of solids-phase in conventional methods like Discrete Element Model and Two-Fluid Model have facilitated the development of alternative techniques such as Particle-In-Cell (PIC). However, a number of parameters are involved in PIC due to its empiricism. In this work, global sensitivity analysis of PIC model parameters is performed under three distinct operating regimes common in chemical engineering applications, viz. settling bed, bubbling fluidized bed and circulating fluidized bed. Simulations were performed using the PIC method in Multiphase Flow with Interphase eXchanges (MFiX) developed by National Energy Technology Laboratory (NETL). A non-intrusive uncertainty quantification (UQ) based approach is applied using Nodeworks to first construct an adequate surrogate model and then identify the most influential parameters in each case. This knowledge will aid in developing an effective design of experiments and determine optimal parameters through techniques such as deterministic or statistical calibration.

01 COAL, LIGNITE, AND PEAT↗

Elimination of active species crossover in a room temperature, neutral pH, aqueous flow battery using a ceramic NaSICON membrane

Flow batteries are an attractive technology for energy storage of grid-scale renewables. However, performance issues related to ion-exchange membrane (IEM) fouling and crossover of species have limited the success of flow batteries. In this work we propose the use of the solid-state sodium-ion conductor NaSICON as an IEM to fully eliminate active species crossover in room temperature, aqueous, neutral pH flow batteries. We measure the room temperature conductivity of NaSICON at 2.83–4.67 mS cm –1 and demonstrate stability of NaSICON in an aqueous electrolyte with conductivity values remaining near 2.5 mS cm –1 after 66 days of exposure. Charge and discharge of a full H-cell battery as well as symmetric cycling in a flow battery configuration using NaSICON as an IEM in both cases demonstrates the capability of the solid-state IEM. Extensive analysis of aged cells through electrochemical impedance spectroscopy (EIS) and UV–vis spectroscopy show no contaminant species having crossed over the NaSICON membrane after 83 days of exposure, yielding an upper limit to the permeability of NaSICON of 4 × 10 –10 cm 2 min –1 . As a result, the demonstration of NaSICON as an IEM enables a wide new range of chemistries for application to flow batteries that would previously be impeded by species crossover and associated degradation.

25 ENERGY STORAGE↗

Design, Fabrication and Start-up of Test Facilities for the LAWPS Full-Scale IX Column Test and Engineering Scale Test - 17418

The U.S. Department of Energy (DOE), Office of River Protection's (ORP) primary mission is to retrieve and treat Hanford's tank waste and close the Tank Farms to protect the Columbia River. Mixed radioactive waste is stored in 177 underground tanks at the Hanford Site as reported in DOE/ORP 2003-02, Environmental Impact Statement for Retrieval, Treatment, and Disposal of Tank Waste and Closure of the Single Shell Tanks at the Hanford Site, Richland WA, Inventory and Source Term Data Package. The 177 underground tanks are estimated to contain about 56 million gallons of waste. The Low Activity Waste Pretreatment System (LAWPS) Project provides for the early production of immobilized low activity waste (ILAW) by feeding LAW directly from Tank Farms to the Hanford Waste Treatment Plant's (WTP's) LAW Facility, bypassing the Pretreatment Facility. Prior to the transfer of feed to the WTP LAW Vitrification Facility, tank supernatant waste will be pretreated in the LAWPS to meet the WTP LAW waste acceptance criteria. The LAWPS will also facilitate the return of secondary liquid wastes from the WTP LAW Vitrification Facility to the Tank Farms. In November of 2015 DOE's Tank Operations Contractor, Washington River Protection Solutions (WRPS), awarded a contract to the AECOM Team to design, fabricate and operate two test platforms to generate performance data at two different scales and demonstrate technology maturation. The first platform models the ion exchange (IX) columns at full scale, and the second platform models the integrated flowsheet (cross flow filter (CFF) and IX) at 1/9. scale. Both test platforms underwent shakedown and start-up testing in August 2016 and moved into actual testing and NQA-1 data generation shortly thereafter. This paper covers the engineering design, procurement, construction, installation, and acceptance testing of the test platforms (which are now operational) under an aggressive fast track schedule, and initial test data as available. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sensitivity Analysis and Effective Parametrization of PEM Fuel Cell Models

The cost of proton-exchange-membrane fuel cells (PEMFCs) remains a major hurdle in large-scale commercialization of this technology. To improve their performance and reduce cost, novel materials and electrode designs are continuously envisioned, e.g., non-PGM catalyst layers, ultra-thin Pt/Pt-Ni based catalyst layers, structured ionomer arrays or NSTF catalyst layers.1 Understanding the impact of these improvement strategies can be extremely time and cost intensive due to complex physical phenomena and large design space. We have previously developed a PEMFC modeling framework2 which has been a time and cost effective tool for understanding and optimizing the complex multi-physics phenomena within PEMFCs; however, several of the cell parameters used in the modeling have large spread in measured data.3 Furthermore, several transport parameters such as water adsorption kinetics have not been accurately measured and the approximations are spread over several orders of magnitude. These uncertainties cause problems in ascertaining accuracy of the modeling approach and they reduce the predictive power of the numerical models. The aim of this work is to identify the sensitivity of PEFC numerical model outputs to various input parameters. The previously in-house developed MEA modeling framework2 is used for PEMFC modeling. The sensitivity of the model outputs with respect to inputs parameters is obtained by analyzing the condition numbers for different output-input pairs at varying operating conditions. An example of the sensitivity analysis is shown in Figure 1. The condition numbers are obtained for the entire possible range of input parameters at varying operating conditions to identify the most crucial parameters of the PEMFC model. Based on our preliminary analysis, parameters related to kinetics (exchange current density and ECSA) and heat/water management in electrodes and ionomer (ionomer fraction, thermal conductivity) are most crucial. One of the major goals of this work is to identify the most crucial set of parameters towards which the model shows maximum sensitivity. This will guide future experimentalists to measure these properties with higher accuracy. Furthermore, the sensitivity analysis will also enable us to optimize the PEMFC performance by selectively targeting the most sensitive parameters and thereby making the largest impact. Acknowledgements The work is funded under the Fuel Cell Performance and Durability Consortium (FC-PAD), by the Fuel Cell Technologies Office (FCTO), Office of Energy Efficiency and Renewable Energy (EERE), of the U.S. Department of Energy under contract number DE-AC02-05CH11231. The authors would like to thank Nathan Craig at Robert Bosch LLC for his valuable input in designing the sensitivity analysis. The authors would also like to thank Giovanna Bucci and Matthias Hanauer at Robert Bosch for their valuable inputs and discussion. References P. K. Sinha, W. Gu, A. Kongkanand and E. Thompson, J. Electrochem. Soc., 158, B831 (2011). L. M. Pant, M. R. Gerhardt, N. Macauley, R. Mukundan, R. L. Borup and A. Z. Weber, Electrochim. Acta, 326, 134963 (2019). R. Vetter and J. O. Schumacher, ArXiv181110091 Phys. (2018). Figure 1

Pant, Lalit↗

Surface Roughness Effects on Heat Transfer in Additively Manufactured sCO 2 Cycle Heat Exchangers

An experimental study was performed to consider the impact of surface roughness on heat transfer and pressure drop to supercritical carbon dioxide (sCO 2 ) in additively manufactured channels. All tests were performed in the Heat Exchange and Experimental Testing (HEET) rig at the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) in Morgantown, West Virginia. Four test articles were considered. The first was a hydrodynamically smooth, drawn tube. The other three were additively manufactured channels with square and rectangular cross sections, which were characterized by sand-grain roughness to hydraulic diameter ratios spanning 0.0029 to 0.0073. Friction factors were determined by measuring the tube mass flow rate and pressure drop. The tube side heat transfer coefficient was measured using the Wilson plot technique. It was found that the friction factor results were 8% greater than the Colebrook correlation. Greater deviation was observed between the heat transfer results and the correlations. The Gnielinski correlation overpredicted the experimental points by nominally 30% and the Norris correlation overpredicting the experimental points by nominally 25%. A thermal performance factor was formed from the friction factor augmentation and Nusselt number augmentation results. These results indicated a 10% improvement in heat duty for a heat exchanger constructed utilizing a tube with ϵ/D_h =0.0073 relative to a heat exchanger utilizing a smooth, conventional tube.

36 MATERIALS SCIENCE↗

Design of Graded Cathode Catalyst Layers with Various Ionomers for Fuel Cell Application

Proton exchange membrane fuel cells (PEMFCs) powered by green hydrogen (H2) have become a promising alternative to conventional hydrocarbon-fueled power generators. Despite technological advancements, further improvements in efficiency, durability, and low-cost production are required for the widespread adoption of PEMFCs. Though numerous approaches to improve PEMFC electrodes have been reported, most strategies utilize a single material set (e.g., one combination of catalyst and ionomer) to improve performance. Alternatively, anisotropic (graded) electrode structures with locally tunable properties may yield superior electrode performance due to improved ionic and gas phase transport. In this work, graded cathode catalyst layers (CCLs) incorporating different ionomers (Nafion D2020, Aquivion D79-25BS, and HOPI) were designed and prepared. Performance screening shows that some of these graded electrode structures have comparable performance to optimized single-ionomer electrode structures (D2020) suggesting some synergistic benefit. Additionally, we show that electrodes with lower equivalent weight (EW) D79 ionomer near the membrane and D2020 ionomer near the gas diffusion media outperformed electrodes with the inverted configuration. Finally, EIS analysis shows some graded ionomer structures (e.g. D79/D2020) have better than expected H+ conductivity, generally leading to better electrode performance. However, further optimization of ionomer content and catalyst ink formulations is needed to improve overall PEMFC performance.