Search NASASearch

SEARCH · Search NASA

Results for “Testing and Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Performance Test Results of the NASA-457M v2 Hall Thruster

Performance testing of a second generation, 50 kW-class Hall thruster labeled NASA-457M v2 was conducted at the NASA Glenn Research Center. This NASA-designed thruster is an excellent candidate for a solar electric propulsion system that supports human exploration missions. Thruster discharge power was varied from 5 to 50 kW over discharge voltage and current ranges of 200 to 500 V and 15 to 100 A, respectively. Anode efficiencies varied from 0.56 to 0.71. The peak efficiency was similar to that of other state-of-the-art high power Hall thrusters, but outperformed these thrusters at lower discharge voltages. The 0.05 to 0.18 higher anode efficiencies of this thruster compared to its predecessor were primarily due to which of two stable discharge modes the thruster was operated. One stable mode was at low magnetic field strengths, which produced high anode efficiencies, and the other at high magnetic fields where its predecessor was operated. Cathode keeper voltages were always within 2.1 to 6.2 V and cathode voltages were within 13 V of tank ground during high anode efficiency operation. However, during operation at high magnetic fields, cathode-to-ground voltage magnitudes increased dramatically, exceeding 30 V, due to the high axial magnetic field strengths in the immediate vicinity of the centrally-mounted cathode. The peak thrust was 2.3 N and this occurred at a total thruster input power of 50.0 kW at a 500 V discharge voltage. The thruster demonstrated a thrust-to-power range of 76.4 mN/kW at low power to 46.1 mN/kW at full power, and a specific impulse range of 1420 to 2740 s. For a discharge voltage of 300 V, where specific impulses would be about 2000 s, thrust efficiencies varied from 0.57 to 0.63.

Soulas, George C.

Thermal Performance Testing of Cryogenic Insulation Systems

Efficient methods for characterizing thermal performance of materials under cryogenic and vacuum conditions have been developed. These methods provide thermal conductivity data on materials under actual-use conditions and are complementary to established methods. The actual-use environment of full temperature difference in combination with vacuum-pressure is essential for understanding insulation system performance. Test articles include solids, foams, powders, layered blankets, composite panels, and other materials. Test methodology and apparatus design for several insulation test cryostats are discussed. The measurement principle is liquid nitrogen boil-off calorimetry. Heat flux capability ranges from approximately 0.5 to 500 watts per square meter; corresponding apparent thermal conductivity values range from below 0.01 up to about 60 mW/m- K. Example data for different insulation materials are also presented. Upon further standardization work, these patented insulation test cryostats can be available to industry for a wide range of practical applications.

Fesmire, James E.

Results of tests performed on the Acoustic Quiet Flow Facility Three-Dimensional Model Tunnel: Report on the Modified D.S.M.A. Design

Numerous tests were performed on the original Acoustic Quiet Flow Facility Three-Dimensional Model Tunnel, scaled down from the full-scale plans. Results of tests performed on the original scale model tunnel were reported in April 1995, which clearly showed that this model was lacking in performance. Subsequently this scale model was modified to attempt to possibly improve the tunnel performance. The modifications included: (a) redesigned diffuser; (b) addition of a collector; (c) addition of a Nozzle-Diffuser; (d) changes in location of vent-air. Tests performed on the modified tunnel showed a marked improvement in performance amounting to a nominal increase of pressure recovery in the diffuser from 34 percent to 54 percent. Results obtained in the tests have wider application. They may also be applied to other tunnels operating with an open test section not necessarily having similar geometry as the model under consideration.

Barna, P. S.

Largo hot water system long range thermal performance test report, addendum

The test procedure used and the test results obtained during the long range thermal performance tests of the LARGO Solar Hot Water System under natural environmental conditions are presented. Objectives of these tests were to determine the amount of energy collected, the amount of power required for system operation, system efficiency, temperature distribution, and system performance degradation.

Source record

DSS 13 frequency stability tests performed during May 1985 through March 1986

Results of station frequency stability testing performed at DSS 13 (Deep Space Station) during May 1985 through March 1986 are presented. The testing was done on X-band uplink and X- and S-band downlink subsystems as well as on end-to-end systems. The subsystem test data are useful for assessing the frequency stability of various prototype X-band uplink or downlink subsystems for purposes of making design improvements. Information derived from extensive testing at DSS 13 will be useful in the preparation of an X-band Uplink Demonstration Experiment to be conducted at DSS 13, and will also be valuable in the preparations of gravity wave experiments to be conducted at other DSN stations in the future.

Otoshi, T. Y.

Structural and preliminary thermal performance testing of a pressure activated contact heat exchanger

A contact heat exchanger concept is being developed for use onboard Space Station as an interface device between external thermal bus and pressurized modules. The concept relies on mechanical contact activated by the fluid pressure inside thin-walled tubes. Structural testings were carried out to confirm the technology feasibility of using such thin-walled tubes. The test results also verified the linear elastic stress analysis which was used to predict the tube mechanical behaviors. A preliminary thermal testing was also performed with liquid Freon-11 flowing inside tubes and heat being supplied by electrical heating from the bottom of the contact heat exchanger baseplate. The test results showed excellent agreement of test data with analytical prediction for all thermal resistances except for the two-phase flow characteristics. Testing with two-phase flow inside tubes will, however, be performed on the NASA-JSC test bed.

Lee, C. Y.

Advanced Transport Delay Compensation Algorithms: Results of Delay Measurement and Piloted Performance Tests

This report summarizes the results of delay measurement and piloted performance tests that were conducted to assess the effectiveness of the adaptive compensator and the state space compensator for alleviating the phase distortion of transport delay in the visual system in the VMS at the NASA Langley Research Center. Piloted simulation tests were conducted to assess the effectiveness of two novel compensators in comparison to the McFarland predictor and the baseline system with no compensation. Thirteen pilots with heterogeneous flight experience executed straight-in and offset approaches, at various delay configurations, on a flight simulator where different predictors were applied to compensate for transport delay. The glideslope and touchdown errors, power spectral density of the pilot control inputs, NASA Task Load Index, and Cooper-Harper rating of the handling qualities were employed for the analyses. The overall analyses show that the adaptive predictor results in slightly poorer compensation for short added delay (up to 48 ms) and better compensation for long added delay (up to 192 ms) than the McFarland compensator. The analyses also show that the state space predictor is fairly superior for short delay and significantly superior for long delay than the McFarland compensator.

Guo, Liwen

Pilot Field Test: Performance of a Sit-to-Stand Test After Long-Duration Space Flight

BACKGROUND: Astronauts returning from the International Space Station are met by a team of recovery personnel typically providing physical assistance and medical support immediately upon landing. That is because long-duration spaceflight impacts astronauts' functional abilities. Future expeditions to planets or asteroids beyond the low Earth orbit, however, may require crewmembers to egress the vehicle and perform other types of physical tasks unassisted. It is therefore important to characterize the extent and longevity of functional deficits experienced by astronauts in order to design safe exploration class missions. Pilot Field Test (PFT) experiment conducted with participation of ISS crewmembers traveling on Soyuz expeditions 34S - 41S comprised several tasks designed to study the recovery of sensorimotor abilities of astronauts during the first 24 hours after landing and beyond. METHODS: The first test in the PFT battery sequence, and also the least demanding one from the sensorimotor perspective, was a Sit-to-Stand test. Test subjects were seated in the chair and had to stand up on command and remain standing for ten seconds. The subjects were instructed to stand up unassisted as quickly as they were able to, while maintaining postural control. Synchronized wireless inertial sensors mounted on the head, chest, lower back, wrists, and ankles were used to continuously log body kinematics. Crewmembers' blood pressure and heart rate were monitored and recorded with the Portapres and Polar systems. Each session was recorded with a digital video camera. During data collections occurring within the 24-hour postflight period, crewmembers were also asked to (1) evaluate their perceived motion sickness symptoms on a 20-point scale before and after completion of the test and (2) estimate how heavy they felt compared to their normal (preflight) body weight. Consent to participate in PFT was obtained from 18 crewmembers (11 US Orbital Segment [USOS] astronauts and 7 Russian cosmonauts). For 10 subjects, the first set of data was collected in the medical tent in Soyuz landing zone (1-2 hours after landing); the other 8 subjects were tested at the Kazakhstan deployment airport (4-5 hours after landing). 8 of the 11 astronauts were tested twice more within the first 24 hours postflight, at a refueling stop on the way to Houston (approximately 13 hours after landing) and at the Johnson Space Center (approximately 24 hours after landing). Later postflight data were collected in the first two weeks on some crewmembers. Finally, 6 astronauts were tested 60+ days after landing to establish a delayed baseline. RESULTS/DISCUSSION: Two of the 18 PFT participants felt too ill to attempt any tests in Kazakhstan (at either the landing zone or deployment airport). The remaining test subjects completed the Sit-to-Stand test and their reported motion sickness scores were unaffected by this task. The task completion times and body kinematics data analysis are currently underway. Preliminary analysis of astronaut data shows a steep improvement in the time to complete the task on the second data take, and in some cases, the trend continues through day six postflight. Head and trunk pitch angles and pitch rates were also examined and increases in all measures are evident throughout the observed recovery period (60+ days postflight). Interesting patterns of head and trunk pitch coordination have also emerged. One of the data analysis objectives is comparison of initial postflight performance and recovery of experienced crewmembers and first-time fliers. Another one - possible differences in performance between USOS and Russian crewmembers.

Kofman, I. S.

Aerodynamic and Acoustic Performance Testing of Metal Spacecraft Cabin Ventilation Fan

A metal spacecraft cabin ventilation fan suitable for aerodynamic and acoustic ground tests was designed and two copies of the fan assembly were fabricated. Both fans were tested for aerodynamic performance and acoustic levels in the NASA Glenn Research Center Acoustical Testing Laboratory. A new test rig for small axial flow fans was designed to accommodate the instrumentation and back-pressure adjustments. Measurements included were: static pressures for measuring performance, a 72-channel in-duct microphone array, external microphone measurements for acoustics, and inter-stage hot wire measurements of the fan wake. The present report documents the test setup. A series of follow on reports documents the results. These fan units, the data and the test facility described herein are valuable resources available for supporting NASA’s aeronautics research and space exploration missions.

Small Fan Noise