At least 91 records · Page 5

The encasulation effect on thermal performance of micro-encapsulated phase change materials during energy absorption

Understanding the performance of the thermal storage materials is required to successfully meet the needs of next generation concentrating solar power projects. This study focuses on the thermal characteristics of the micro-encapsulated phase change material (MEPCM) with metallic core under high temperature. A numerical model was developed and verified to study the transient heat absorption process of MEPCMs made of tin, aluminum and copper core. Convective heat transfer rate, total energy absorption and volumetric energy density were presented. The effect of encapsulation on theses variables was analyzed under various boundary and initial conditions. Its impact on characteristic time variables was discussed. The method presented can be adopted to analyzing both manufacturing and application processes for MEPCMs of various compositions, during which melting and solidification happen. Given certain operating conditions, the results from the model can be referenced to obtain optimal thermal performance of these materials.

Benner, Jingru↗

Experimental Investigation of a Phase Change Material Charged Finned-Tube Heat Exchanger

Understanding different thermal performance aspects of phase change material heat exchangers (PCM-HX) is critical for designing future energy-efficient thermal energy storage systems. This paper presents an experimental performance analysis of a vertically oriented annular finned-tube PCM-HX in a cylindrical container tested under six different melting and solidification test conditions, varied by heat transfer fluid’s (HTF) inlet temperatures and flow directions. The PCM-HX structure with 20 evenly spaced fins was 3D printed in aluminum, and the PCM-HX container was 285 mm in height. The PCM-HX average porosity was 89.7%, where the PCM mass was 246.4 g. Water served as the HTF, and a PCM with a nominal phase change temperature of 35 °C was selected. Instead of opaque conventional insulation sheets, a combination of air-and-argon-filled see-through insulation cylinders was assembled with the PCM-HX to visualize the phase-change phenomena, while minimizing the uncertainties due to heat loss. In total, there were 78 T-type thermocouples installed in the test section which allows a more precise assessment of thermal mass and heat loss, which are often neglected in similar studies found in the literature. We validated the reliability of the test facility as the repeated test results had negligible deviations under the same test conditions. The energy balances between the estimated theoretical and experimentally calculated PCM storage, considering heat loss and thermal mass, were within ±9% deviation for all test conditions. From the experimental investigations, we made several following observations. It was found that the melting pattern of the finned-tube PCM-HX with small gaps between the container wall and the fins was largely affected by the HTF flow directions, unlike the typical straight annular tube PCM-HX. For effective charging and discharging processes, a combination of upward melting and downward solidification is recommended to shorten the test duration. However, an upward solidification should be considered to minimize the cavity formation between the fins caused by the PCM volume contraction during the solidification process.

25 ENERGY STORAGE↗

Achieving extraordinary thermal stability of salt hydrate eutectic composites by amending crystallization behaviour with thickener

Commercial thermal energy storage (TES) systems necessitate reliable thermal performance throughout their operational lifetime. Repeated volume changes of the phase change materials (PCMs) during thermal cycling disengages thermal contacts between the conductive fillers like expanded graphite (EG) in TES composites, causing unstable thermal conductivity (k) that fades with cycling. Our in-operando crystallization studies on eutectic PCM made of zinc nitrate hexahydrate (ZNH) and KNO 3 revealed that the thermal stability of PCM composites can be considerably degraded by the formation of large and sharp-cornered PCM crystals during the freezing cycle. While the crystals can push EG particles, disengaging thermal contacts between them, we have newly discovered that carboxymethyl cellulose (CMC) can be used to retain the thermal contacts by forming networks of smaller PCM crystals. Furthermore, the scalable synthesis methodology of EG/ZNH eutectic composites was introduced. Here, in this study, EG particles were strongly connected into a matrix via a stable, corrosion resistant polydimethylsiloxane (PDMS) binder, stabilizing thermal networks and thereby maintaining k up to 1000 melt/freeze cycles. The thermal conductivity of our 25 vol% EG sample (13.3 W m -1 K -1 ) is more than 48% higher than other salt hydrate eutectic composites reported in the literature. We expect this study to provide insights on cooperative interaction between different components of TES systems (PCM, filler, thickener, binder) for exceptionally robust thermal properties.

36 MATERIALS SCIENCE↗

Experimental and numerical study on the impacts of various long carbon fiber inserts on the thermal performance of phase change materials

In thermal energy storage systems, phase change materials (PCMs) are widely used to provide efficient storing and extraction of thermal energy. However, most PCMs have low thermal conductivities, which limit the heat transfer of the latent energy inward/outward. In this study, the impacts of various fiber inserts on the solidification and melting processes with PCM were investigated by experiments and simulations. It was found that long anisotropic carbon fibers with high thermal conductivities can not only increase the heat transfer within PCM by enlarging hot-cold interface areas, but also act as crystallization nuclei and increase the solidification of PCM during the charging process. Recalescence of PCM during solidification was observed. COMSOL models were used to understand the thermal transfer mechanisms. COMSOL Multiphysics models of a single carbon fiber filament in PCM showed that the anisotropy in thermal conductivities controlled the radial and axial heat transfer ratios along its fiber axis and can enhance both the solidification and melting processes.

Zhou, Xinzhang↗

Thermal Energy Storage (TES) Modeling and Design (CRADA Final Report)

This project will assess the performance of an innovative high efficiency air conditioner integrated with a composite phase change material (PCM). The research will address critical electric grid challenges by evaluating the thermal efficiency and load-shifting capabilities in NREL’s HVAC characterization lab.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration: Preprint

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Numerical modeling and parametric study of a dual purpose underground thermal battery

We report integrating thermal energy storage with building energy systems can enable flexible building electric demands at buildings to help mitigate the mismatch between electricity supply and demand. A novel building heating and cooling system that integrates a dual-source heat pump with hybrid thermal storage named dual-purpose underground thermal battery (DPUTB) has been developed for reshaping building electric demands. The proposed DPUTB integrated geothermal heat pump system is an original innovation that enables Grid-interactive Energy Efficient buildings. This paper focuses on the study of the novel DPUTB. The DPUTB works as both a thermal storage tank (an inner tank) and a ground heat exchanger (an outer tank separated from the inner tank by the insulation material). High fidelity and computationally effective models are needed to predict the performance of the novel DPUTB. This study has developed a simplified dynamic model for the DPUTB according to heat transfer and energy conservation principles and validated it by using experimental data obtained from testing a small-scale DPUTB apparatus. A parametric study was conducted to identify a design that can achieve the target thermal storage performance of load shift and energy efficiency. The parametric study results show that the inner tank shell thermal conductivity and the phase change material's melting point are the two most influencing factors on the performance of the DPUTB. One single full-size DPUTB with the identified design could provide 1-ton cooling (3.51 kW) with the supply temperature lower than 11 °C for 4 hours in summer after being fully charged in 8 hours. The inner tank filled with phase change material is for cooling thermal storage as a latent tank in the design. However, its capacity can be as high as 60 MJ as a sensible water tank for heating storage in winter. In the future study, the DPUTB model will be incorporated into the dual-source heat pump system for evaluating the overall system performance of demand side management in the long term.

25 ENERGY STORAGE↗

Model Predictive Control for a Grid-interactive Efficient Thermal Storage-integrated Heat Pump System

Building heating and cooling systems can be used to overcome the mismatch between the intermittent supply of renewable power and the fluctuating demand for electricity. A novel underground thermal energy storage integrated with a dual-source heat pump has been proposed to mitigate the mismatch while meeting the thermal demand of buildings efficiently. Conventional thermostat control with heuristic rules cannot provide intelligent decisions to maximize the thermal efficiency and flexibility of the proposed system. Advanced control strategies like model predictive control (MPC) have provided a new paradigm for grid-interactive efficient building operation with the advancement of computation and sensing. This study developed an MPC for the proposed system to provide grid service for Demand Side Management and minimize the operating cost of building owners. A control-oriented dynamic model of the proposed system has been developed. Given an objective function and proper constraints, an optimization problem is formulated to determine the optimal control strategy of the system. Dynamic Programming is adopted to solve the optimization problem. A rule-based control (RBC) is also developed to achieve similar goals. Short-term simulations are conducted to compare the system performance resulting from the two controls. The simulation results indicate that the MPC performs more intelligently than the RBC in charging thermal energy storage and selecting heat pump sources by taking advantage of the predicted cooling demands of the building and the performance of the integrated system. As a result, the MPC could save energy and reduce operating costs compared with the RBC. A case study shows that, for a 3-day operation, the MPC saves 36.9% energy and reduces 38.5% operating cost compared with the RBC.

Shi, Liang↗

Performance Evaluation and Optimal Design Analysis of Continuous-Operation Solar-Driven Cooling Absorption Systems With Thermal Energy Storage

A solar absorption cooling system consisting of a flat plate collector, thermal energy storage tank, and absorption chiller is analyzed in this work. A dimensionless model is developed from the energy balance on each component and the chiller's characteristic performance curves. The model is used to determine the interaction and influence of different parameters such as tank size, solar collector area, chiller size, cooling load, cooling temperature, heat loss, and mass flow rates on the performance. From the analysis, smaller solar collector areas are required for lower cooling loads and smaller tank volumes. A specific cooling load of 1 x 10^-5 will require a specific solar collector area between two and six times larger, depending on the initial tank temperature, than the area required for a baseline system that considers typical commercial design and operation parameters. A similar behavior was observed for the specific tank volume. For the baseline system, the minimum specific area of the collector of 9.57 is achieved for an initial tank temperature of 1.19. For a cooling load of 1 x 10^-5, the optimum initial tank temperature will be 1.11 that results in a minimum specific solar collector area of 25.26. A specific tank volume of 4 x 10^-4 will also have an optimum initial tank temperature of 1.11 that minimizes the specific solar collector area to a value of 28.18. The approach and analysis in this work can be used to determine design parameters for solar absorption cooling systems based on a proper relation among system's dimensions to achieve optimum operation.

cooling load↗

Feasibility Analysis for the Use of Retrofitted Air-Conditioners Using Thermal Energy Storage (TES) for High Ambient Temperature (HAT) Countries

In high ambient temperature (HAT) countries, summer temperatures exceed 35℃, degrading the performance of air-conditioning systems and straining power grids. In this paper, a feasibility analysis was conducted to investigate potential savings during the peak using latent Thermal Energy Storage (TES) at near room phase-change temperatures, replacing condensers, thus, minimizing temperature lifts. Weather data, building loads, and baseline air-conditioning systems data were gathered for Dubai. A transient vapor-compression model in Modelica was used to compare the COP, total power input and cooling capacity of the air-conditioner at peak hours when ambient temperatures range between 35 – 45 ⁰C versus the TES-Phase-Change Material (PCM) melting temperatures from 22 – 28⁰C. The results indicate that the TES-PCM can enhance the system COP at the peak by a factor 1.4 and 2 for during for outdoor temperatures of 35 – 40⁰C, and 40 – 45⁰C, respectively. Lower melting temperature PCMs were able to reduce the required power input by 30-50%, with more savings occurring at higher temperature days. On the other hand, higher temperature PCMs enhancements were minimal especially at outdoor ambient temperatures ranging between 35 – 40⁰C. Improvements to the cooling capacity range from 8 – 18 % for the outdoor temperature range of 35 – 45 ⁰C. An economic analysis was conducted to find the potential saving in utility costs for 30%, 60%, and 90% of the space cooling demands of Dubai, and find the trade-off points between utility savings and cost of PCM-TES implementation. If the peak loads are to be shifted by 6 hours daily, the percentage utility savings for the city is 18%. Using estimated costs of the PCM-TES, ranging from $200-500/kWh, the daily load shifting hours were estimated to range from 4 hours at the lowest cost systems to 2.5 hours at the highest costs.

25 ENERGY STORAGE↗

Technoeconomic Analysis of Steel Production with Electric Thermal Energy Storage

The iron and steel industry is an important manufacturing sector and one of the largest energy consumers in the United States and globally. Hydrogen direct reduction of iron ore (H2DRI) is considered a promising process that could enhance domestic steel production. This process requires hydrogen inlet temperatures up to 950 degrees C to drive the endothermic reduction of the iron ore pellets. In this work we investigate the technoeconomic performance of an H2DRI plant using electric thermal energy storage (ETES) technologies for the hydrogen heating, compared to conventional natural gas fired heaters, hydrogen fired heaters, and electric hydrogen heaters. A technoeconomic analysis framework for the plant is developed and used in multiple case studies, covering different hydrogen prices, grid electricity profiles, and financing scenarios. The levelized cost of steel production is found out to be in the range of $775-950/mt, which is mostly inside the benchmarked steel price of $941/mt. ETES-based hydrogen heating is found to be in par with conventional natural gas fired heaters, and cheaper than hydrogen fired heaters and electric hydrogen heaters. The major cost drivers are the iron ore and hydrogen feedstock, followed by the hydrogen compression and heating capital. Several insights and suggested future directions are identified.

08 HYDROGEN↗

Modeling and Experimental Validation of a Direct-Contact Counter-Flow Fluidized Bed Heat Exchanger for Thermal Energy Storage (TES) Applications

Particle-based thermal energy storage (TES) systems are an emerging energy storage technology. The technological advances have reduced costs, making TES more competitive and reliable in the marketplace but an efficient and reliable operation is heavily dependent on coherent heat transfer between air to particles or vice versa. The particle-based TES technologies provide an intermediate system that can store energy for short (0-10 h), long (10-200 h) and seasonal (> 200 h) timescales. The TES systems store energy by converting electricity to thermal energy; electricity can be directly sourced intermittent generation technologies and/or the grid, helping manage peak loads and other mismatches in supply and demand. The overall efficiency of the TES system depends on the performance of system components (particle storage silos and particle transfer mechanism etc.). The particle heat exchanger is one of the key system components that affects the system efficiency. The pressurized fluidized bed heat exchanger (PFB HX) performance is challenging to predict due to the chaotic behavior of particle and fluid interaction. This research presents a computational study of a novel direct-contact, counter-flow and air-to-particles PFB HX, that contributes in advancing the particle-based long-duration TES technologies. For the current analysis an unsteady Eulerian-Eulerian CFD model was developed and validated against experiments performed at the National Laboratory of the Rockies for two particle sizes (600 ..mu..m and 825 ..mu..m ). Following validation, parametric simulations were conducted to evaluate the effects of interphase drag models (Syamlal-O'Brien and Gidaspow), particle size, bed height and the influence of a frictional-viscosity term on hydrodynamics and heat transfer between the air & particles. The key findings from the analysis are: (1) for the studied operating window Syamlal-O'Brien provides superior agreement with measured gas temperatures (errors generally < 10%) while Gidaspow shows large deviations for the coarse particle case; (2) model predictions are most sensitive in the lower 0.2 m above the air distributor where bubble initiation and local mixing dominate interphase heat transfer; (3) representation of the distributor (number of inlet ports) materially affects predicted local mixing and temperature stratification; and (4) the Eulerian-Eulerian framework reproduces bulk thermal trends but shows regime dependent limitations for coarse particles, motivating mesoscale informed closures for scale-up analysis for future studies. These results provide validated guidance for drag selection and distributor design in particle-based thermal energy storage applications. Collectively, the validated model and parametric results quantify key drivers of PHB-HX performance and provide practical guidance for design and optimization. The results provide confidence in the model predictability and provide a step forward to improve on heat exchange performance. The demonstrated performance and modeling approach support the deployment and further development of this novel PHB-HX concept for robust, particle-based long-duration thermal energy storage systems.

25 ENERGY STORAGE↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Grid Interactive Micro-Distributed Refrigerated Display Case

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Fabrication of New PCM Hydrogel Composites

Salt hydrates are low-cost phase-change materials (PCMs) with excellent thermal energy storage capacities. However, they are limited by low thermal cycling stability due to incongruent melting-induced phase separation. This project will solve the long-standing issue of phase separation of salt hydrates by stabilizing salt particles in a charged polymer hydrogel network. The proposed approach uses combined physical and chemical stabilization mechanisms achieved by selecting a proper chemistry and molecular weight of the polymer matrix. In summary, we have identified several important formulations that show good energy storage capacity performance and good cycling stability. The thermal storage capacity can be further improved through further sample optimization. The thermal conductivities of the samples were low, but there are ways to improve it by adding a highly thermally conductive material with a high aspect ratio. The method of preparation is suitable for scale-up.

25 ENERGY STORAGE↗

Impact of Mass Wood Walls on Building Energy Use, Peak Demand, and Thermal Comfort

Thermal mass moderates indoor temperatures, allowing the heating, ventilation, and air conditioning (HVAC) system to operate more efficiently during peak hours. Cross-Laminated Timber (CLT) and other mass wood products provide thermal mass to the building envelope in a lighter and more environmentally friendly form than concrete. However, the influence of CLTs on heating and cooling energy, peak energy demand, and the indoor climate is not well-known. This project was formed to find the energy efficiency benefits of mass timber structures. The objectives were to (1) test the thermal performance of insulated mass wall structures in controlled laboratory conditions, (2) validate simulation models to expand performance to natural climatic conditions, (3) isolate the impact of the thermal properties of wood (thermal mass, thermal conductivity, moisture storage) on heating and cooling energy use and peak energy demand, and to optimize the performance. Currently, the designs used for CLT buildings have focused on structural and fire issues, and they do not consider the thermal mass benefits. Therefore, the thermal performance is not necessarily optimized.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗