Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermal instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The heat pipe thermal canister

The thermal canister represents a new approach to instrument thermal control for Shuttle experiments which require tight temperature control. The canister substitutes a known, benign thermal environment for the variable and uncertain environment of space, the space environment being neutralized by a system of feedback controlled variable conductance heat pipes. A proto-flight unit has been fabricated and this paper describes the acceptance thermal vacuum test results of the thermal canister experiment which will fly on an early Space Shuttle flight.

Harwell, W.↗

Temperature and heat flux measurements: Challenges for high temperature aerospace application

The measurement of high temperatures and the influence of heat transfer data is not strictly a problem of either the high temperatures involved or the level of the heating rates to be measured at those high temperatures. It is a problem of duration during which measurements are made and the nature of the materials in which the measurements are made. Thermal measurement techniques for each application must respect and work with the unique features of that application. Six challenges in the development of measurement technology are discussed: (1) to capture the character and localized peak values within highly nonuniform heating regions; (2) to manage large volumes of thermal instrumentation in order to efficiently derive critical information; (3) to accommodate thermal sensors into practical flight structures; (4) to broaden the capabilities of thermal survey techniques to replace discrete gages in flight and on the ground; (5) to provide supporting instrumentation conduits which connect the measurement points to the thermally controlled data acquisition system; and (6) to develop a class of 'vehicle tending' thermal sensors to assure the integrity of flight vehicles in an efficient manner.

Neumann, Richard D.↗

Vented and sealed cookoff of powdered and pressed ε-CL-20

In this work, we have completed a series of vented and sealed cookoff experiments of the ε-polymorph of CL-20 in our Sandia Instrumented Thermal Ignition (SITI) apparatus using both powder and pressed pellets at nominal densities of 313 ± 8 kg/m 3 and 1030 ± 4 kg/m 3 , respectively. The boundary temperature of our aluminum confinement cylinder was ramped in 10 minutes from room temperature to a prescribed set-point temperature ranging between 448 nd 468 K and held at the set-point temperature until ignition. A universal cookoff model (UCM) has been calibrated using the ε-CL-20 SITI data to predict pressurization and thermal ignition of ε-CL-20. The ignition model was validated by using one-dimensional time-to-explosion (ODTX) ignition data from a different laboratory. We found that a thirtyfold increase in the reaction rates due to liquefaction at 520 K could explain the high temperature ODTX cookoff data. The model gives a plausible explanation of why melting is important in fast cookoff events involving CL-20. Our model also gives support to 520 K as the liquefaction point of CL-20, which has different values in the literature.

36 MATERIALS SCIENCE↗

The use of a thermal utility with space-platform-mounted instruments

A thermal utility is a high-capacity heat transport system that serves as a common, temperature-controlled heat sink or source to more than one payload. The feasibility of using a thermal utility for space-platform-mounted instruments which have a range of temperature level and heat rejection requirements is examined and significant design parameters are identified. A baseline, pumped, two-phase heat transport system has been defined for NASA's proposed Space Platform, and its capability to satisfy the thermal requirements of a range of multidisciplinary instruments has been assessed.

Almgren, D. W.↗

Low Temperature Time-to-Explosion Experiments on HMX in the LLNL's ODTX/P-ODTX System (FY 2020 Annual Report)

Over the last few decades, there has been a considerable research effort on the thermal decomposition and thermal explosion violence of energetic materials at elevated temperatures in different sample geometries and confinements. Thermal explosion studies on various energetic materials in two-dimensional geometry such as the Scaled-Thermal-Explosion-Experiment (STEX) system and the Sandia-Instrumented-Thermal-Ignition (SITI) system have been reported. The One-Dimensional Time to Explosion (ODTX) system, designed and built by LLNL, has been used since 1970s for thermal explosion studies. The system is attractive because of the one-dimensional geometry and minimal sample requirement. With the recent integration of a pressure monitoring element, the system can study pressure behavior of materials subjected to and during thermal exposure. Rapid pressure monitoring in µsec intervals allow for enhanced pressure determination in the time right before thermal explosion. The test data can be used for the validation of existing thermal models, particularly for introducing pressure terms. This report summarizes the efforts in performing small-scale safety tests, particle size measurements and conducting 7 ODTX/P-ODTX experiments on the Cl5 HMX material that Hunting uses for oil field applications.

36 MATERIALS SCIENCE↗

The Thermal Ion Dynamics Experiment and Plasma Source Instrument

The Thermal Ion Dynamics Experiment (TIDE) and the Plasma Source Instrument (PSI) have been developed in response to the requirements of the ISTP Program for three-dimensional (3D) plasma composition measurements capable of tracking the circulation of low-energy (0-500 eV) plasma through the polar magnetosphere. This plasma is composed of penetrating magnetosheath and escaping ionospheric components. It is in part lost to the downstream solar wind and in part recirculated within the magnetosphere, participating in the formation of the diamagnetic hot plasma sheet and ring current plasma populations. Significant obstacles which have previously made this task impossible include the low density and energy of the outflowing ionospheric plasma plume and the positive spacecraft floating potentials which exclude the lowest-energy plasma from detection on ordinary spacecraft. Based on a unique combination of focusing electrostatic ion optics and time of flight detection and mass analysis, TIDE provides the sensitivity (seven apertures of about 1 cm squared effective area each) and angular resolution (6 x 18 degrees) required for this purpose. PSI produces a low energy plasma locally at the POLAR spacecraft that provides the ion current required to balance the photoelectron current, along with a low temperature electron population, regulating the spacecraft potential slightly positive relative to the space plasma. TIDE/PSI will: (a) measure the density and flow fields of the solar and terrestrial plasmas within the high polar cap and magnetospheric lobes; (b) quantify the extent to which ionospheric and solar ions are recirculated within the distant magnetotail neutral sheet or lost to the distant tail and solar wind; (c) investigate the mass-dependent degree energization of these plasmas by measuring their thermodynamic properties; (d) investigate the relative roles of ionosphere and solar wind as sources of plasma to the plasma sheet and ring current.

Moore, T. E.↗

Overview of IMPACT Data Acquisition System and Data Reduction Process

This report documents the development of the data acquisition system (DAS) and data reduction methodologies for the Irradiated Material Property Accelerated Characterization Test (IMPACT) experiment at the Advanced Test Reactor (ATR). The IMPACT experiment is designed to enable in-pile measurement of thermal conductivity in metallic nuclear fuels, specifically U-10Zr, using an instrumented thermal conductivity probe. The DAS supports both passive temperature monitoring and active thermal interrogation of the probe through controlled AC and DC excitation. Significant modifications to laboratory-scale systems were required to accommodate the higher resistance paths associated with the in-pile application. Custom electronics and relay-controlled measurement sequencing were developed to enable the measurement and sufficient power delivery to the sensing region. A reduced-order, axisymmetric thermal model based on the thermal quadrupoles method is presented to support data interpretation. This model enables efficient evaluation of transient heat transfer behavior and facilitates solution of the inverse problem required to extract thermal properties from measured signals. Multiple boundary condition formulations are discussed to address varying experimental time scales and geometries. Additionally, machine learning techniques are introduced to support data reduction and improve confidence in inverse solutions. Convolutional neural networks are applied to identify the presence of gas gaps and other evolving geometric features that significantly impact thermal response during irradiation. These efforts contribute to the broader integration of digital twin frameworks and real-time modeling capabilities within the Advanced Fuels Campaign.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Cryogenic Limb Array Etalon Spectrometer (CLAES) S/N001 cryostat test results

The results of a test program designed to verify the operational and thermal performance of the Cryogenic Limb Array Etalon Spectrometer (CLAES) S/N001 Ne/CO2 cryostat, as monitored and serviced by the Data Acquisition System and Ground Support Equipment, are presented. The S/N001 model test assembly consists of the S/N001 configuration coupled with an instrument thermal mass simulator (ITMS) for simulating the thermal behavior of the instrument package. The test data for the cryostat include the rate of temperature decrease of the various parts of the cryostat/ITMS and the final equilibrium temperatures of the shields, thermal links, and tank. The test results showed that system heat rates, operating temperatures, and expected end-of-life temperature predictions all agree with predictions within estimated margins.

Horsley, W. J.↗

Validation of Landsat-7 ETM+ MEM Thermal Improvement in Thermal Vacuum Tests and in Flight Due to Lower Louver Set Points

The Enhanced Thematic Mapper Plus (ETM+) Main Electronics Module (MEM) power supply heat sink temperature is critical to the Landsat-7 mission. It is strongly dependent on the thermal louver design. A lower power supply heat sink temperature increases the reliability of the MEM, and reduces the risk of over heating and thermal shut-down. After the power supply failures in ETM+ instrument thermal vacuum tests #1 and #2, the author performed detailed thermal analyses of the MEM, and proposed to reduce the louver set-points by 7C. At the 1998 Intersociety Energy Conversion Engineering Conference (IECEC), the author presented a paper that included results of thermal analysis of the MEM. It showed that a 70C reduction of the louver set points could reduce the maximum power supply heat sink temperature in thermal vacuum test and in flight to below 20"C in the cooler outgas mode and in the nominal imaging mode, and has no significant impact on the standby heater duty cycle. It also showed that the effect of Earth infrared and albedo on the power supply heat sink temperature is small. The louver set point reduction was implemented in June 1998, just prior to ETM+ thermal vacuum test #3. Results of the thermal vacuum tests, and temperature data in flight validate the MEM thermal performance improvement due to the 70C reduction of the louver set points.

Choi, Michael K.↗

Nanophase Carbonates on Mars: Formation, Detection, and Implications

Despite having an atmosphere composed primarily of CO2 and evidence for abundant water in the past, carbonate minerals have only been discovered on Mars in small amounts in martian dust, in soils in the Northern Plains, and in outcrops of limited spatial extent. Recently, carbonates have been identified as the possible source of CO2 released during thermal analysis of material from an aeolian deposit named Rocknest and drilled sample from the sheepbed mudstone, both samples analyzed by the Mars Science Laboratory (MSL) in Gale Crater. Both the Phoenix lander and MSL carry thermal analysis instruments, the Thermal and Evolved Gas Analyzer (TEGA) on Phoenix and the Sample Analysis at Mars (SAM) instrument on MSL. While thermal analysis does not provide definitive mineralogy, it can detect volatile-bearing minerals present at very low abundance and the temperature profiles of evolved gases can reveal physical properties of the sample. For example, the decomposition temperature of volatilebearing minerals depends heavily on the particle size of the mineral.

Archer, P. D.↗

Transforming polymorphs, melting, and boiling during cookoff of PETN

Transforming polymorphs, melting, and boiling are physical processes that can accelerate decomposition rates during cookoff of PETN and make measurements difficult. For example, splashing liquids from large bubbles filled with decomposition products clog pressure tubing in sealed experiments. Boil over can also extinguish thermal excursions in vented experiments making ignition difficult. For better measurements, we have modified the Sandia Instrumented Thermal Ignition (SITI) experiment to obtain better sealed and vented cookoff data for PETN by reducing the sample size and including additional gas space to prevent clogged tubing and boil over. Ignition times were not affected by 1) increasing the gas space by a factor of 3 in sealed SITI experiments or by 2) venting the decomposition gasses. That is, thermal ignition of PETN is not pressure dependent and the rate-limiting step during PETN decomposition likely occurs in the condensed phase. A simple decomposition model was calibrated using these observations and includes rate acceleration caused by melting and boiling. The model is used to predict internal temperatures, pressurization, and thermal ignition in a wide variety of experiments. Furthermore, the model is also used with SITI data to estimate the previously unreported latent enthalpy (5 J/g) associated with the α (PETN-I) to β (PETN-II) polymorphic phase transformation of PETN.

42 ENGINEERING↗

Dry in-pile fracture test (DRIFT) for separate-effects validation of ceramic fuel fracture models

Fracture is an important component of nuclear fuel behavior, and significant efforts have been invested into developing fuel performance models that are capable of accurately representing fracture. Usable data on the process of fracture propagation in nuclear fuel under realistic service conditions are very limited. To address this need, a series of separate-effects experiments were developed and performed at Idaho National Laboratory's Transient Reactor Test (TREAT) facility. These experiments employ a heat sink to radially remove heat from the fuel in a manner that approximates the effect of coolant in an operating light-water reactor (LWR). The test holder for these experiments is known as the Dry In-pile Fracture Test (DRIFT). A series of experiments employing DRIFT and TREAT were performed to provide data on the extent and nature of fracture in fresh fuel at various points during a ramp to full power. Novel aspects of these experiments include the way they employ a heat sink to replicate steady-state LWR conditions, as well as the use of fiber optic sensors for in-reactor thermal instrumentation. Details on the development of this experiment, experimental conditions, and resulting data (including in situ thermal measurements and post-irradiation imaging of fracture) are provided in this work. LWR-equivalent powers ranging from 10 to 25 kW/m were tested using this apparatus. Cracking was visible at all power levels, with increasing cracking extent as the power level increased, although there was little difference in the cracking between the two highest-power tests, which had LWR-equivalent powers of 20 and 25 kW/m.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Compact Micromachined Bandpass Filters for Infrared Planetary Spectroscopy

The thermal instrument strawman payload of the Jupiter Europa Orbiter on the Europa Jupiter Science Mission will map out thermal anomalies, the structure, and atmospheric conditions of Europa and Jupiter within the 7-100 micron spectral range. One key requirement for the payload is that the mass cannot exceed 3.7 kg. Consequently, a new generation of light-weight miniaturized spectrometers needs to be developed. On the path toward developing these spectrometers is development of ancillary miniaturized spectroscopic components. In this paper, we present a strategy for making radiation hard and low mass FIR band pass metal mesh filters. Our strategy involves using MEMS-based fabrication techniques, which will permit the quasi-optical filter structures to be made with micron-scale precision. This will enable us to achieve tight control over both the pass band of the filter and the micromachined silicon support structure architecture, which will facilitate integration of the filters for a variety of applications.

Brown, Ari D.↗

A Radiation Hard Multi-Channel Digitizer ASIC for Operation in the Harsh Jovian Environment

In 1995, the Galileo spacecraft arrived at Jupiter to conduct follow-up experiments on pathfinder Pioneer and key Voyager discoveries especially at Io, Europa, Ganymede and Callisto. These new observations helped expand our scientific knowledge of the prominent Galilean satellites; studies revealed diversity with respect to their geology, internal structure, evolution and degree of past and present activity. Jupiter's diverse Galilean satellites, of which three are believed to harbor internal oceans, are central to understanding the habitability of icy worlds. Galileo provided for the first time compelling evidence of a near-surface global ocean on Europa. Furthermore, by understanding the Jupiter system and unraveling the history of its evolution from initial formation to the emergence of possible habitats and life, gives insight into how giant planets and their satellite systems form and evolve. Most important, new light is shed on the potential for the emergence and existence of life in icy satellite oceans. In 2009, NASA released a detailed Jupiter Europa Mission Study (EJSM) that proposed an ambitious Flagship Mission to understand more fully the satellites Europa and Ganymede within the context of the Jovian system. Key to EJSM is the NASA led Jupiter Europa Orbiter (JEO) and the ESA led Jupiter Ganymede Orbiter (JGO). JEO and JGO would execute a choreographed exploration of the Jovian system before settling into orbit around Europa and Ganymede, respectively. The National Academies Planetary Decadal Survey, 2011 has listed the NASA-led JEO as the second highest priority mission for the decade 2013-2022, and if chosen it would be launched in 2020 with arrival at Jupiter in 2025. If the JEO mission is not chosen it is anticipated that there will be opportunities in future decadal cycles. Jupiter Orbit Insertion (JOI) begins a 30-month Jovian system tour followed by nine months of science mapping after Europa Orbit Insertion (EOI) in July 2028. The orbiter will ultimately impact the surface of Europa after the mission is completed. The current JEO mission concept includes a range of instruments on the payload, to monitor dynamic phenomena (such as Io's volcanoes and Jupiters atmosphere), map the Jovian magnetosphere and its interactions with the Galilean satellites, and characterize water oceans beneath the ice shells of Europa and Ganymede. The payload includes a low mass (3.7 Kg) and low power (< 5 W) Thermal Instrument (TI) concept for measuring possible warm thermal anomalies on Europa s cold surface caused by recent (< 10,000 years) eruptive activity. Regions of anomalously high heat flow will be identified by thermal mapping using a nadir pointing, push-broom filter radiometer that provides far-IR imagery in two broad band spectral wavelength regions, 8-20 m and 20-100 m, for surface temperature measurements with better than a 2 K accuracy and a spatial resolution of 250 m/pixel obtained from a 100 Km orbit. The temperature accuracy permits a search for elevated temperatures when combined with albedo information. The spatial resolution is sufficient to resolve Europa's larger cracks and ridge axial valleys. In order to accomplish the thermal mapping, the TI uses sensitive thermopile arrays that are readout by a custom designed low-noise Multi-Channel Digitizer (MCD) ASIC that resides very close to the thermopile linear array outputs. Both the thermopile array and the MCD ASIC will need to show full functionality within the harsh Jovian radiation environment, operating at cryogenic temperatures, typically 150 K to 170 K. In the following, a radiation mitigation strategy together with a low risk Radiation-Hardened-By-Design (RHBD) methodology using commercial foundry processes is given for the design and manufacture of a MCD ASIC that will meet this challenge.

Aslam, Shahid↗

In-Flight Performance of the TES Loop Heat Pipe Rejection System: Seven Years in Space

The Tropospheric Emission Spectrometer (TES) instrument heat rejection system has been operating in space for nearly 8 years since launched on NASA's EOS Aura Spacecraft. The instrument is an infrared imaging fourier transform spectrometer with spectral coverage of 3.2 to 15.4 microns. The loop heat pipe (LHP) based heat rejection system manages all of the instrument components waste heat including the two mechanical cryocoolers and their drive electronics. Five propylene LHPs collect and transport the instrument waste heat to the near room temperature nadir viewing radiators. During the early months of the mission, ice contamination of the cryogenic surfaces including the focal planes led to increased cryocooler loads and the need for periodic decontamination cycles. Focal plane decontamination cycles require power cycling both cryocoolers which also requires the two cryocooler LHPs to turn off and on during each cycle. To date, the cryocooler LHPs have undergone 24 start-ups in orbit successfully. This paper reports on the TES cryocooler loop heat pipe based heat rejection system performance. After a brief overview of the instrument thermal design, the paper presents detailed data on the highly successful space operation of the loop heat pipes since instrument turn-on in 2004. The data shows that the steady-state and transient operation of the LHPs has not changed since 2004 and shows consistent and predictable performance. The LHP based heat rejection system has provided a nearly constant heat rejection heat sink for all of its equipment which has led to exceptional overall instrument performance with world class science.

allowable flight temperature↗

Investigation of the thermal control of instruments mounted in the Space Shuttle cargo bay

Results are presented for an investigation intended to examine the orbital averaged thermal response of a number of instruments, each being representative of a class of scientific instrumentation, when they are individually mounted on pallets and operated in the cargo bay of the Shuttle. The discussion covers mainly the Shuttle Orbiter thermal models, the solar viewing instrument, and the high-energy instrument. One approach to thermal insulation of smaller instruments is to provide a thermal canister insulated from the cargo bay and equipped with variable conductance heat pipes. Two approaches are proposed for larger instruments. One approach is to provide a thermal curtain across the top of the pallet which shields the pallet cavity from direct sunlight, while the second approach is to provide a fluid system to transfer heat from a specified location on an instrument to either a space viewing radiator on the pallet or instrument or the orbiter cooling system. These thermal control design concepts represent several ideas for standard reusable thermal control systems.

Bartoszek, J. T.↗

NASA Applications of Molecular Adsorber Coatings

The Molecular Adsorber Coating (MAC) is a new, innovative technology that was developed to reduce the risk of molecular contamination on spaceflight applications. Outgassing from materials, such as plastics, adhesives, lubricants, silicones, epoxies, and potting compounds, pose a significant threat to the spacecraft and the lifetime of missions. As a coating made of highly porous inorganic materials, MAC offers impressive adsorptive capabilities that help capture and trap contaminants. Past research efforts have demonstrated the coating's promising adhesion performance, optical properties, acoustic durability, and thermal stability. These results advocate its use near or on surfaces that are targeted by outgassed materials, such as internal optics, electronics, detectors, baffles, sensitive instruments, thermal control coatings, and vacuum chamber test environments. The MAC technology has significantly progressed in development over the recent years. This presentation summarizes the many NASA spaceflight applications of MAC and how the coatings technology has been integrated as a mitigation tool for outgassed contaminants. For example, this sprayable paint technology has been beneficial for use in various vacuum chambers for contamination control and hardware bake-outs. The coating has also been used in small instrument cavities within spaceflight instrument for NASA missions.

molecular contaimination↗

Development of High Fidelity, Fuel-Like Thermal Simulators for Non-Nuclear Testing

This viewgraph presentation reviews the development of a simulator for non-nuclear tests for the development of a space nuclear power system. The development of the Instrumented Thermal Simulator is to assist in developing an understanding of individual components and integrated system operation without the cost, time, safety concerns associated with nuclear testing. The presentation shows the design, the electrical integration, the hardware, and the assembly of the simulators. There are slides that show the test plan, the analysis, and the initial results.

Bragg-Sitton, Shannon↗