Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thick Target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Characteristics of miniature electronic brachytherapy x-ray sources based on TG-43U1 formalism using Monte Carlo simulation techniques

Purpose: The goal of this study is to determine a method for Monte Carlo (MC) characterization of the miniature electronic brachytherapy x-ray sources (MEBXS) and to set dosimetric parameters according to TG-43U1 formalism. TG-43U1 parameters were used to get optimal designs of MEBXS. Parameters that affect the dose distribution such as anode shapes, target thickness, target angles, and electron beam source characteristics were evaluated. Optimized MEBXS designs were obtained and used to determine radial dose functions and 2D anisotropy functions in the electron energy range of 25-80 keV. Methods: Tungsten anode material was considered in two different geometries, hemispherical and conical-hemisphere. These configurations were analyzed by the 4C MC code with several different optimization techniques. The first optimization compared target thickness layers versus electron energy. These optimized thicknesses were compared with published results by Ihsan et al.[Nucl. Instrum. Methods Phys. Res. B 264, 371-377 (2007)]. The second optimization evaluated electron source characteristics by changing the cathode shapes and electron energies. Electron sources studied included; (1) point sources, (2) uniform cylinders, and (3) nonuniform cylindrical shell geometries. The third optimization was used to assess the apex angle of the conical-hemisphere target. The goal of these optimizations was to produce 2D-dose anisotropy functions closer to unity. An overall optimized MEBXS was developed from this analysis. The results obtained from this model were compared to known characteristics of HDR {sup 125}I, LDR {sup 103}Pd, and Xoft Axxent electronic brachytherapy source (XAEBS) [Med. Phys. 33, 4020-4032 (2006)]. Results: The optimized anode thicknesses as a function of electron energy is fitted by the linear equation Y ({mu}m) = 0.0459X (keV)-0.7342. The optimized electron source geometry is obtained for a disk-shaped parallel beam (uniform cylinder) with 0.9 mm radius. The TG-43 distribution is less sensitive to the shape of the conical-hemisphere anode than the hemispherical anode. However, the optimized apex angle of conical-hemisphere anode was determined to be 60 deg. For the hemispherical targets, calculated radial dose function values at a distance of 5 cm were 0.137, 0.191, 0.247, and 0.331 for 40, 50, 60, and 80 keV electrons, respectively. These values for the conical-hemisphere targets are 0.165, 0.239, 0.305, and 0.412, respectively. Calculated 2D anisotropy functions values for the hemispherical target shape were F(1 cm, 0 deg.) = 1.438 and F(1 cm, 0 deg.) = 1.465 for 30 and 80 keV electrons, respectively. The corresponding values for conical-hemisphere targets are 1.091 and 1.241, respectively. Conclusions: A method for the characterizations of MEBXS using TG-43U1 dosimetric data using the MC MCNP4C has been presented. The effects of target geometry, thicknesses, and electron source geometry have been investigated. The final choices of MEBXS design are conical-hemisphere target shapes having an apex angle of 60 deg. Tungsten material having an optimized thickness versus electron energy and a 0.9 mm radius of uniform cylinder as a cathode produces optimal electron source characteristics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-energy proton capture reactions

An overview of experimental problems in measuring the cross sections for (p,γ) and (p,n) reactions at low energies is given with a specific emphasis on electron screening in metallic targets. Thick target γ-ray and neutron yields are compared for Ni and NiO targets, V and VO{sub 2} targets and Mn and MnO targets. The {sup 1}H({sup 7}Li,α){sup 4}He reaction was studied in inverse kinematics with hydrogen loaded into Pd and PdAg alloy foils from gas phase. Based on these results, a new approach to electron screening in nuclear reactions is suggested.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Method and apparatus for sensing a target characteristic by measuring both impedance and resonant frequency of a tank circuit

An apparatus for sensing a target characteristic, such as relative distance between the apparatus and target, target thickness, target material, or lateral position between the apparatus and the target, includes a coil for directing an electro-magnetic field at the target. A voltage controlled oscillator energizes the coil at a resonant frequency which is functionally related to the target characteristic. The coil has an effective impedance value at resonance functionally related to the target characteristic. A frequency monitor measures the resonant frequency. An impedance monitor determines the impedance value when the drive frequency is at the resonant value. A PROM or controller determines the target characteristic in response to the measured resonant frequency and the determined impedance value. The PROM or controller provides a signal responsive to the determined target characteristic.

Laskowski, Edward L.↗

TU-H-BRC-06: Temperature Simulation of Tungsten and W25Re Targets to Deliver High Dose Rate 10 MV Photons

Purpose: To study the impact of electron beam size, target thickness, and target temperature on the ability of the flattening filter-free mode (FFF) treatment head to deliver high-dose-rate irradiations. Methods: The dose distribution and transient temperature of the X-ray target under 10 MeV electron beam with pulse length of 5 microseconds, and repetition rate of 1000 Hz was studied. A MCNP model was built to calculate the percentage depth dose (PPD) distribution in a water phantom at a distance of 100 cm. ANSYS software was used to run heat transfer simulations. The PPD and temperature for both tungsten and W25Re targets for different electron beam sizes (FHWM 0.2, 0.5, 1 and 2 mm) and target thickness (0.2 to 2 mm) were studied. Results: Decreasing the target thickness from 1 mm to 0.5 mm, caused a surface dose increase about 10 percent. For both target materials, the peak temperature was about 1.6 times higher for 0.5 mm electron beam compared to the 1 mm beam after reaching their equilibrium. For increasing target thicknesses, the temperature rise caused by the first pulse is similar for all thicknesses, however the temperature difference for subsequent pulses becomes larger until a constant ratio is reached. The target peak temperature after reaching equilibrium can be calculated by adding the steady state temperature and the amplitude of the temperature oscillation. Conclusion: This work indicates the potential to obtain high dose rate irradiation by selecting target material, geometry and electron beam parameters. W25Re may not outperformed tungsten when the target is thick due to its relatively low thermal conductivity. The electron beam size only affects the target temperature but not the PPD. Thin target is preferred to obtain high dose rate and low target temperature, however, the resulting high surface dose is a major concern. NIH funding:R21 EB015957-01; DOD funding:W81XWH-13-1-0165 BL, PM, PB, and RF are founders of TibaRay, Inc. BL is also a borad member. BL and PM have received research grants from Varian Medical System, Inc. and RaySearch Laboratory. RF is an employee of Siemens Healthcare GmbH.

60 APPLIED LIFE SCIENCES↗

Thermomechanical response of thickly tamped targets and diamond anvil cells under pulsed hard x-ray irradiation

In the laboratory study of extreme conditions of temperature and density, the exposure of matter to high intensity radiation sources has been of central importance. Here, we interrogate the performance of multi-layered targets in experiments involving high intensity, hard x-ray irradiation, motivated by the advent of extremely high brightness hard x-ray sources, such as free electron lasers and 4th-generation synchrotron facilities. Intense hard x-ray beams can deliver significant energy in targets having thick x-ray transparent layers (tampers) around samples of interest for the study of novel states of matter and materials’ dynamics. Heated-state lifetimes in such targets can approach the microsecond level, regardless of radiation pulse duration, enabling the exploration of conditions of local thermal and thermodynamic equilibrium at extreme temperature in solid density matter. The thermal and mechanical responses of such thick layered targets following x-ray heating, including hydrodynamic relaxation and heat flow on picosecond to millisecond timescales, are modeled using radiation hydrocode simulation, finite element analysis, and thermodynamic calculations. Assessing the potential for target survival over one or more exposures and resistance to damage arising from heating and resulting mechanical stresses, this study doubles as an investigation into the performance of diamond anvil high pressure cells under high x-ray fluences. Long used in conjunction with synchrotron x-ray radiation and high power optical lasers, the strong confinement afforded by such cells suggests novel applications at emerging high intensity x-ray facilities and new routes to studying thermodynamic equilibrium states of warm, very dense matter.

Meza-Galvez, J. (ORCID:000000032699849X)↗

Analytic limits on the forms of spectra possible from optically thin collisional bremsstrahlung source models

The constraints on hard X-ray bremsstrahlung spectral forms required in order for them to correspond to physically acceptable (nonnegative) electron distributions in thin-target, thick-target, and thermal source models are discussed. The extent to which various spectra can be attributed to the different models is examined, showing that many possible spectra cannot be described by all, or in some cases, any of the models. It is shown that for any bremsstrahlung cross section, the thick-target and thermal models require that successively higher derivatives of the thin-target constraint have the appropriate sign. It is found that thermal models are the most restrictive, and that thin-target models are the least restrictive. Explicit analytic constraint expressions are derived for all three cases for the Kramers cross section and examples of acceptable and unacceptable spectra are given. Application of these criteria to the testing and exclusion of models is discussed.

Brown, John C.↗

SU-F-T-361: Dose Enhancement Due to Nanoparticle Addition in Skin Radiotherapy: A Monte Carlo Study Using Kilovoltage Photon Beams

Purpose: This study investigated the dose enhancement due to addition of nanoparticles with different types and concentrations in skin radiotherapy using kilovoltage photon beams. Methods: An inhomogeneous water phantom (15×15×10 cm{sup 3}) having the skin target layer (0.5–5 mm), added with different concentrations (3–40 mg/ml) of nanoparticles (Au, Pt, I, Ag and Fe{sub 2}O{sub 3}), was irradiated by the 105 and 220 kVp photon beams produced by a Gulmay D3225 Orthovoltage unit. The circular cone of 5-cm diameter and source-to-surface distance of 20 cm were used. Doses in the skin target layer with and without adding the nanoparticles were calculated using Monte Carlo simulation (the EGSnrc code) through the macroscopic approach. Dose enhancement ratio (DER), defined as the ratio of dose at the target with nanoparticle addition to the dose without addition, was calculated for each type and concentration of nanoparticle in different target thickness. Results: For Au nanoparticle, DER dependence on target thickness for the 220 kVp photon beams was not significant. However, DER for Au nanoparticle was found decreasing with an increase of target thickness when the nanoparticle concentration was increased from 18 to 40 mg/ml using the 105 kVp photon beams. For nanoparticle concentration of 40 mg/ml, DER variation with target thickness was not significant for the 220 kVp photon beams, but DEF was found decreasing with the target thickness when lower energy of photon beam (105 kVp) was used. DEF was found increasing with an increase of nanoparticle concentration. The higher the DEF increasing rate, the higher the atomic number of the nanoparticle except I and Ag for the same target thickness. Conclusion: It is concluded that nanoparticle addition can result in dose enhancement in kilovoltage skin radiotherapy. Moreover, the DER is related to the photon beam energy, target thickness, atomic number and concentration of nanoparticles.

60 APPLIED LIFE SCIENCES↗

Comparisons on thin and thick neutron target for low energy proton beam

As the progress on accelerator physics and neutronics, the compact neutron sources driven by low energy and high intensity beam are becoming extensively developed and researched all around the world. The neutron target of an accelerator driven neutron source is one of the key components, and the stability of the neutron target affect the operation and performance of the neutron facility. When a low energy proton is projected to the beryllium target, the main reaction is the inelastic scattering between the proton and extra-nuclear electrons. As the decreasing of proton energy, the rate of elastic scattering between proton and target nucleus begins to increase. When the energy of proton is very low, the pickup charge reaction begins to appear. Focus on the problems brought by high intensity proton beam such as proton implantation, radiation damages, heat deposition and gas production, we performed sufficient numerical simulations for both thin and thick target determined by proton range. The results show that the critical problem for thick target is the proton implantation, causing the forming of bubbles and beryllium flaked in vacuum. The thin target sacrifices a little neutron yield, but avoid the proton stopped in target, and decrease the radiation damage and energy deposition. (authors)

43 PARTICLE ACCELERATORS↗

Energetic particles in solar flares

The various manifestations of energetic particles in solar flares are examined, and possible mechanisms for the acceleration of these particles are considered. Hard X-ray observations and possible mechanisms for the production of the dominant form of solar energetic particles, electrons with energies between 10 and 100 keV, are discussed, with consideration of thin-target models, thick-target models and thick-target models with reverse currents, and first-phase acceleration mechanisms for energetic electrons emitting impulsive microwave and fast-drift Type III radio bursts as well as impulsive hard X rays, which are detected themselves 20 min after the flare at 1 AU are considered. Radio evidence on the number, energy and pitch-angle distributions of energetic particles produced during solar flares is summarized, and observations at 1 AU of proton and electron energy spectra, the proton/electron ratio and energetic particle events rich in He-3 from solar flares are discussed. Finally, consideration is given to gamma-ray evidence of nuclear reactions in flares and white-light flares

Ramaty, R.↗

Strong surface magnetic field generation in relativistic short pulse laser–plasma interaction with an applied seed magnetic field

Abstract While plasma often behaves diamagnetically, we demonstrate that the laser irradiation of a thin opaque target with an embedded target-transverse seed magnetic field B seed can trigger the generation of an order-of-magnitude stronger magnetic field with opposite sign at the target surface. Strong surface field generation occurs when the laser pulse is relativistically intense and results from the currents associated with the cyclotron rotation of laser-heated electrons transiting through the target and the compensating current of cold electrons. We derive a predictive scaling for this surface field generation, B gen ∼ −2 πB seed Δ x / λ 0 (in the large spot size limit), where Δ x is the target thickness and λ 0 is the laser wavelength, and conduct 1D and 2D particle-in-cell simulations to confirm its applicability over a wide range of conditions. We additionally demonstrate that both the seed and surface-generated magnetic fields can have a strong impact on application-relevant plasma dynamics, for example substantially altering the overall expansion and ion acceleration from a μ m-thick laser-irradiated target with a kilotesla-level seed magnetic field.

Weichman, K. (ORCID:0000000234877922)↗

Energy of microwave-emitting electrons and hard x-ray/microwave source model in solar flares

Based on the rate of increse of the microwave flux relative to the hard X-ray flux at various energies from the onset to the peak of a flare, the mean energy of microwave-emitting electrons is estimated for 22 flares observed simultaneously in hard X-rays and microwaves. The energy of electrons varying in proportion to the 17 GHz emission is found to concentrate below 100 keV, and the mean energy or eletrons emitting 70 keV x-rays is less than about 130 keV for thin-target and less than about 180 keV for thick-target emission models, suggesting that the 17 GHz emission derives from electrons with energy of less than a few hundred keV. The magnetic field strength in the microwave source is found to be 500-1000 G for the thick-target and 1000-2000 G for the thin-target case, and 16 of the 22 events examined can be successfully explained by the thick-target model. Of the six events which cannot be explained by the thick-target model, two events give L of less than about 300 km.

Nitta, N.↗

Target Design Optimization of KIPT Neutron Source Facility

Argonne National Laboratory (ANL) of the United States developed and designed a neutron source facility for Kharkov Institute of Physics and Technology (KIPT) of Ukraine. The facility was constructed at Kharkov, Ukraine and its commissioning process has been started. The facility has an electron accelerator driving a subcritical assembly. The electron beam power is 100 kW using 100 MeV electrons. The subcritical assembly has WWR-M2 fuel assemblies with U-235 enrichment of 19.7 wt%. The facility will be utilized to perform basic and applied nuclear research, to produce medical isotopes, and to train young nuclear specialists. Solid target design with stacked disks is selected and each target disk is cooled by water from both side. Tungsten or natural uranium is the target material. This paper presents the target design optimization to maximize the neutron yield and the neutron flux level of the facility while satisfying the thermal-hydraulic design criteria. Monte Carlo computer code MCNPX is utilized for the neutron yield analyses with ENDF/B-VII.0 nuclear data libraries, as a function of target thickness using a simplified target model without cladding or coolant channels. It’s found that the neutron yield saturates at target thickness 60 ~ 70 mm for both tungsten and uranium materials. For the final target design with cladding and coolant channels, the total uranium thickness is 56.5 mm, and the total tungsten thickness is only 33.0 mm. The tungsten material has a large absorption cross section for thermal neutrons. If the tungsten thickness is increased, the neutron yield gain is offset by the neutron absorption reaction. The paper presents the design optimization analyses for both target materials.

electron accelerator↗