Fiber-optic bolometer with low detection limit fabricated using thermal release tape and precise laser heating

Fiber-optic bolometers (FOBs) based on a fiber-tipped silicon Fabry–Perot (FP) interferometric temperature sensor and a gold disk absorber have been shown to be an attractive alternative to conventional resistive bolometers for plasma radiation measurement in fusion devices. Either a high-finesse FP or a low-finesse FP can be used, each with trade-offs between noise performance and fabrication complexity. In this paper, we present an FOB design that overcomes these limitations by combining a low-finesse long silicon FP cavity with a large gold disk absorber to achieve enhanced sensitivity and noise performance without increasing the fabrication complexity and the time constant. We also demonstrated a fabrication method for the sensor head facilitated by thermal release tape and precise laser heating. Our FOB demonstrates a temperature resolution of 0.08 mK, a cooling time constant of 230 ms, and a noise equivalent power density of 0.015 W m −2 . This represents an eightfold improvement over previous high-finesse FOBs and 26-fold improvement over previous low-finesse FOBs with similar demodulation bandwidths and similar cooling time constants.

Fabry–Perot interferometer↗

Observations of the interaction of ozone and dynamics

Data on the global distribution of temperature and ozone obtained with the Limb Radiance Inversion Radiometer which flew on the Nimbus 6 spacecraft are analyzed within the conceptual framework of Hartmann and Garcia (1979). The analysis supports the conclusion that ozone perturbations are dynamically controlled when the photochemical time constant is much greater than the dynamical time constant; when the photochemical constant is much less than the dynamical constant, ozone perturbations are photochemically controlled. It is also shown that the transports of planetary waves, or eddy transports, appear to be strongly localized in the region between the regimes in which dynamical and photochemical controls operate.

Gille, J. C.↗

Flying-qualities criteria for wings-level-turn maneuvering during an air-to-ground weapon delivery task

A moving-base simulator experiment conducted at Ames Research Center demonstrated that a wings-level-turn control mode improved flying qualities for air-to-ground weapons delivery compared with those of a conventional aircraft. Evaluations of criteria for dynamic response for this system have shown that pilot ratings correlate well on the basis of equivalent time constant of the initial response. Ranges of this time constant, as well as digital-system transport delays and lateral-acceleration control authorities that encompassed Level I through Level III handling qualities, were determined.

Sammonds, R. I.↗

Flying-qualities criteria for wings-level-turn maneuvering during an air-to-ground weapon delivery task

A moving base simulator experiment demonstrated that a wings-level-turn control mode improved flying qualities for air to ground weapon delivery compared with those of a conventionally controlled aircraft. Evaluations of criteria for dynamic response for this system have shown that pilot ratings correlate well on the basis of equivalent time constant of the initial response. Ranges of this time constant, as well as digital system transport delays and lateral acceleration control authorities that encompassed level 1 through 3 handling qualities, were determined.

Sammonds, R. I.↗

Electronic clinical predictive thermometer using logarithm for temperature prediction

A thermometer that rapidly predicts body temperature based on the temperature signals received from a temperature sensing probe when it comes into contact with the body. The logarithms of the differences between the temperature signals in a selected time frame are determined. A line is fit through the logarithms and the slope of the line is used as a system time constant in predicting the final temperature of the body. The time constant in conjunction with predetermined additional constants are used to compute the predicted temperature. Data quality in the time frame is monitored and if unacceptable, a different time frame of temperature signals is selected for use in prediction. The processor switches to a monitor mode if data quality over a limited number of time frames is unacceptable. Determining the start time on which the measurement time frame for prediction is based is performed by summing the second derivatives of temperature signals over time frames. When the sum of second derivatives in a particular time frame exceeds a threshold, the start time is established.

Cambridge, Vivien J.↗

Mathematical analysis of the Photovoltage Decay (PVD) method for minority carrier lifetime measurements

When the diffusion length of minority carriers becomes comparable with or larger than the thickness of a p-n junction solar cell, the characteristic decay of the photon-generated voltage results from a mixture of contributions with different time constants. The minority carrier recombination lifetime tau and the time constant l(2)/D, where l is essentially the thickness of the cell and D the minority carrier diffusion length, determine the signal as a function of time. It is shown that for ordinary solar cells (n(+)-p junctions), particularly when the diffusion length L of the minority carriers is larger than the cell thickness l, the excess carrier density decays according to exp (-t/tau-pi(2)Dt/4l(2)), tau being the lifetime. Therefore, tau can be readily determined by the photovoltage decay method once D and L are known.

Vonroos, O. H.↗

Riding and handling qualities of light aircraft: A review and analysis

Design procedures and supporting data necessary for configuring light aircraft to obtain desired responses to pilot commands and gusts are presented. The procedures employ specializations of modern military and jet transport practice where these provide an improvement over earlier practice. General criteria for riding and handling qualities are discussed in terms of the airframe dynamics. Methods available in the literature for calculating the coefficients required for a linearized analysis of the airframe dynamics are reviewed in detail. The review also treats the relation of spin and stall to airframe geometry. Root locus analysis is used to indicate the sensitivity of airframe dynamics to variations in individual stability derivatives and to variations in geometric parameters. Computer programs are given for finding the frequencies, damping ratios, and time constants of all rigid body modes and for generating time histories of aircraft motions in response to control inputs. Appendices are included presenting the derivation of the linearized equations of motion; the stability derivatives; the transfer functions; approximate solutions for the frequency, damping ratio, and time constants; an indication of methods to be used when linear analysis is inadequate; sample calculations; and an explanation of the use of root locus diagrams and Bode plots.

Smetana, F. O.↗

Methods and apparatus for determining cardiac output

The present invention provides methods and apparatus for determining a dynamical property of the systemic or pulmonary arterial tree using long time scale information, i.e., information obtained from measurements over time scales greater than a single cardiac cycle. In one aspect, the invention provides a method and apparatus for monitoring cardiac output (CO) from a single blood pressure signal measurement obtained at any site in the systemic or pulmonary arterial tree or from any related measurement including, for example, fingertip photoplethysmography.According to the method the time constant of the arterial tree, defined to be the product of the total peripheral resistance (TPR) and the nearly constant arterial compliance, is determined by analyzing the long time scale variations (greater than a single cardiac cycle) in any of these blood pressure signals. Then, according to Ohm's law, a value proportional to CO may be determined from the ratio of the blood pressure signal to the estimated time constant. The proportional CO values derived from this method may be calibrated to absolute CO, if desired, with a single, absolute measure of CO (e.g., thermodilution). The present invention may be applied to invasive radial arterial blood pressure or pulmonary arterial blood pressure signals which are routinely measured in intensive care units and surgical suites or to noninvasively measured peripheral arterial blood pressure signals or related noninvasively measured signals in order to facilitate the clinical monitoring of CO as well as TPR.

Cohen, Richard J.↗

UV-Induced Degradation and Associated Metastability in TOPCon Photovoltaic Modules: Understanding Kinetics and Cell Variance

Tunnel oxide passivated contact (TOPCon) silicon photovoltaic (PV) modules are dominating the PV market, but they may be susceptible to degradation under ultraviolet (UV)-containing light. Quantifying the impacts of UV-induced degradation (UVID) is complicated by an associated metastability causing further degradation under dark storage and rapid recovery under sunlight. Here, we study modules that have -2.3% to -3.2% nonrecoverable UVID loss after 60 kWh/m2 dose of 340 nm light and additional recoverable loss under dark storage. We use in situ electroluminescence (EL) imaging to characterize the post-UVID metastability at the module level. The cell-by-cell dark degradation and recovery kinetics span a wide range from +6% to -70% changes in EL intensity after 520 h of dark storage, which returns to +- 4% of the initial post-UVID EL intensity after illumination. The kinetics follow double exponential rates with dark storage degradation time constants of 345 and 45 h, and UV light recovery time constants of 5 min and 36 s. We propose that this is consistent with prior reports of kinetics for light-soaking metastability in Al2O3 passivation. Finally, we further show that cells having high UVID also have injection-dependent effective carrier lifetimes and significant intra-cell variance, suggesting possible origins of processing inconsistency.

14 SOLAR ENERGY↗

Heterogeneous physicochemistry of the polar ozone hole

Processes occurring in the polar winter stratosphere, which involve polar stratospheric clouds (PSCs), are investigated using observations from the Airborne Antarctic Ozone Experiment. In particular, data on the properties of PSCs and their physical chemistry, the microphysical processes and time constants for cloud processes, the heterogeneous chemical processes and their time constants, and nonlinearities in the long-term ozone trend associated with physical and chemical processes are examined. The chemical reactions leading to the depletion of the inert chlorine reservoir in a presence of type I PSCs are established, and it is shown that type II PSCs contribute to chemical processing that sustains the chemical imbalance of the polar stratosphere. It is shown that, using a simple model, the decadal evolution of the Antarctic ozone hole may be understood through nonlinearities in the heterogeneous chemistry, with possible contributing effects of variations in stratospheric temperatures and water vapor concentrations.

Turco, Richard P.↗

The Chinchilla's vestibulo-ocular reflex

The horizontal vestibulo-ocular reflex (VOR) was measured and characterized in seven adult chinchillas using 0.01 to 1.0 Hz angular velocity sinusoids. Gains were less than compensatory, and were variable from day to day, but phases were highly repeatable both within and between animals. The best fitting transfer function to the average data of all animals had a dominant time constant of 7.5 sec, and an adaptation operator with a time constant of 24.0 sec. There were certain nonlinearities in the horizontal VOR of this animal, and it was difficult to elicit a robust optokinetic response. Results are discussed in relation to similar measurements in other species.

Merwin, W. H., Jr.↗

Fine time structure in the 1979 March 5 gamma ray burst

Data on the impulsive phase of the 1979 March 5 gamma ray burst, taken by three identical detectors aboard the Prognoz 7, Venera 11, and Venera 12 spacecraft with 2 ms time resolution, are presented. The first 200 ms of the time history may be described by an exponential decay with time constant of approximately 120 ms up to approximately 100 ms, and time constant of approximately 30 ms thereafter; at low energies, a pulsating component with a period of approximately 23 ms appears. The data could be consistent with torsional vibrations of a neutron star, the rotation of a rapidly spinning neutron star, or oscillations caused by interactions between hot plasma and a magnetic field.

Barat, C.↗

Multiplexing of Hot-Electron Nanobolometers Using Microwave SQUIDs

We have obtained the first data on the multiplexed operation of titanium hot-electron bolometers (HEB). Because of their low thermal conductance and small electron heat capacity nanobolometers are particularly interesting as sensors for far-infrared spectroscopy and mid- and near-IR calorimetry. However, the short time constant of these devices (approximately microseconds at 300-400 mK) makes time domain or audio-frequency domain multiplexing impractical. The Microwave SQUID (MSQUID) approach pursued in this work uses dc SQUIDs coupled to X-band microresonators which are, in turn, coupled to a transmission line. We used a 4-element array of Ti HEBs operated at 415 mK in a He3 dewar with an optical fiber access. The microwave signal exhibited 10-MHz wide resonances at individual MSQUD frequencies between 9 GHz and 10 GHz. The resonance depth is modulated by the current through the bolometer via a change of the SQUID flux state. The transmitted signal was amplified by a cryogenic amplifier and downconverted to baseband using an IQ mixer. A 1-dB per ??/2 responsivity was sufficient for keeping the system noise at the level of ~ 2 pA/Hz1/2. This is more than an order of magnitude smaller than phonon noise in the HEB. The devices were able to detect single near- IR photons (1550 nm) with a time constant of 3.5 ?s. Follow-on work will scale the array to larger size and will address the microwave frequency signal generation and processing using a digital transceiver.

microwave readout↗

Recovery from vestibular ototoxicity

OBJECTIVE: Determine whether subjects with documented vestibular ototoxicity recover vestibular function and, if so, investigate the recovery dynamics. STUDY DESIGN: Prospective and retrospective reviews and repeated measures. SETTING: Clinical research and technology center. SUBJECTS: Twenty-eight subjects who received vestibulotoxic medications were followed for at least 12 months after initial treatment. CONTROLS: Our subject sample was compared with a published database of normal individuals. INTERVENTIONS: All 28 subjects received systemically administered medications known to be ototoxic. The subjects' treating physicians controlled medication, dosage, and administration schedules. MAIN OUTCOME MEASURES: Tests of horizontal canal vestibulo-ocular function were performed. Subjects' auditory and vestibular symptoms were recorded. RESULTS: Eleven subjects (39%) showed changes in horizontal canal vestibulo-ocular gain constant (GC) and/or time constant (TC) consistent with vestibular ototoxicity. When tested 1 year after ototoxic drug administration, eight of the nine subjects who experienced ototoxic decrease in GC showed a recovery of GC to normal limits. Only one of the eight subjects who experienced ototoxic decrease in TC showed recovery of TC to within normal limits. Ototoxicity onset and recovery were independent of baseline vestibular function, and ototoxicity onset did not correlate with cumulative dose of ototoxic medication. There was no relationship between subjective symptoms and ototoxicity onset. CONCLUSIONS: Recovery of GC after vestibular ototoxicity is more commonly observed than recovery of TC. Because ototoxic changes developed and continued in an unpredictable time and manner in relation to ototoxic drug administration, we propose that once ototoxic changes in vestibulo-ocular reflex are detected, ototoxic medications should be discontinued as soon as possible.

NASA Discipline Neuroscience↗

An analysis of aircraft lateral-directional handling qualities using pilot models.

An analytical study of the combined pilot-aircraft system to develop a procedure for computing pilot ratings for the lateral-directional response. In the analytical procedure the pilot is represented by a linear, second-order pilot model, and the aircraft by linear equations of motion. Two levels of pilot response were described by the pilot model. The first level contains a static gain and a second-order lag function with a time constant of 0.2 second. The second level added a 1-sec lead time constant. The second level is assumed to represent a greater effort on the part of the pilot. If the system response characteristics can be achieved with the first-level pilot model, it is concluded that the aircraft will be given a pilot rating of satisfactory. If the aircraft characteristics are such that the second-level pilot model is required to achieve the prescribed system response, it is concluded that the aircraft will be rated tolerable.

Adams, J. J.↗

Polar process and world climate /A brief overview/

A review is presented of events relating polar regions to the world climate, the mechanisms of sea ice and polar ice sheets, and of two theories of the Pleistocene Ice Ages. The sea ice which varies over time scales of one or two years and the polar ice sheets with time changes measured in tens or hundreds of thousands of years introduce two distinct time constants into global time changes; the yearly Arctic sea ice variations affect northern Europe and have some effect over the entire Northern Hemisphere; the ice-albedo coupling in the polar ice sheets is involved in major climatic events such as the Pleistocene ice ages. It is concluded that climate problems require a global approach including the atmosphere, the oceans, and the cryosphere.

Goody, R.↗

Solar UV variability - Effects on stratospheric ozone, trace constituents and thermal structure

The effect of long-term (11-year solar cycle) solar UV variability on stratospheric chemical and thermal structure has been studied using a time-dependent one-dimensional model. Previous studies have suggested substantial variations in local and total ozone, and in stratospheric thermal structure from solar minimum to solar maximum. It is shown that significant variations also occur in some of the trace constituents. Members of the HOx family and N2O exhibit the largest variations, and these changes, if detected, may provide additional means of verifying the presence of solar UV variability and its effects. Some of the species show large phase differences with the assumed solar flux variation. The role of chemical and transport time constants on the time variations of the trace species is examined. Comparisons with reported ozone and temperature data show reasonable agreement for the period 1960 to 1972.

Natarajan, M.↗

Development and Certification of a New Stall Warning and Avoidance System

Several methods may be employed to improve natural stall characteristics. The method employed on all learjets to obtain improved stall characteristics is a stall warning and avoidance system that employs angle of attack vanes, an electronic computer, a control column shaker motor, and a torquer which drives the control column in a pusher mode to avoid unwanted further buildup of angle of attack. The new system was developed with changes that improve system response with no performance penalty or increase in turbulence sensitivity. The following changes were made included modified system time constants and (alpha) time rate of change of vane angle dead zone and the addition of an alpha signal limiter and an alpha cut out below a specified angle of attack.

Gertsen, W. M.↗