Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time-resolved imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Laser-driven ultrafast transmission electron microscopy

Recent advances in lasers and electron optics technology have allowed transmission electron microscopes to achieve high spatial and temporal resolution, making them capable of tracking atoms, charges and spin motions down to the attosecond and nanometre scales. This Primer discusses the most common and practical experimental implementation of time-resolved transmission electron microscopy and the stroboscopic mode for evaluating ultrafast reversible dynamics. An in-depth discussion of photo-induced near-field electron microscopy, a technique unique to laser-assisted electron microscopy, is also provided, covering its prospective applications in the study of coherent phenomena in quantum materials. The experimental strategies and limitations in investigating the structural dynamics of materials and nanostructures by imaging, diffraction and spectroscopy are also described in detail, with a direct comparison with more conventional and established techniques. Here, we provide key information for new researchers who intend to use ultrafast transmission electron microscopy to address new challenges in specific materials science, condensed matter and nanophotonics.

Transmission electron microscopy↗

Sub-10 nm upconversion nanocrystals for long-term single-particle tracking

Lanthanide-doped upconversion nanoparticles are attractive single-molecule imaging probes due to their high photostability and anti-Stokes luminescence. However, achieving both small particle size and strong brightness has remained a major challenge, as reducing size often leads to dimmer emission. Herein, we fabricate a sub-10 nm cascade actively protected upconversion nanoparticles, which shows a 33-fold enhanced upconversion efficiency at the single-particle level compared to larger ~19 nm conventional nanoparticles. Theoretical modeling and time-resolved measurements show that emission loss mainly comes from energy leakage of Er 3+ ions to surface defects. By introducing a NaYbF 4 layer as photon-harvesting and protective intermediate layer, we minimize this energy loss and significantly boost brightness. A monolayer of inert NaLuF 4 can effectively suppress the surface quenching to Yb 3+ . Using these ultra-small bright probes, we successfully tracked single epidermal growth factor receptor molecules on live cells for up to one hour, revealing dynamic switching between different diffusion modes.

Qiu, Xiaochen [Fudan Univ., Shanghai (China); Shen↗

Time-resolved spectrophotometry of the emission lines in the galactic X-ray source H2252-035

The galactic X-ray source H2252-035 has been the object of a concentrated observational effort, since Griffiths et al. (1980) have identified it with a cataclysmic variable-like spectrum. Since the observed 859 s periodicity corresponds to the beat frequency between the X-ray and orbital periods, it has been interpreted as related to a reprocessing of the X-ray flux into optical emission in some region of the system which is rotating with the orbital period and heated by beamed X-ray emission from the compact star. In connection with the present investigation, H2252-035 has been observed with a 120 inch (3 m) telescope and image dissector scanner on 1980 September 9/10 and on 1981 September 20/21. At a time resolution of approximately 2 minutes, four bright emission lines showed short time-scale flickering and a pronounced orbital period variation in phase with the continuum modulation. A two-component model for the line emission region is proposed.

Clarke, J. T.↗

Microscopy X-ray imaging enriched with small angle X-ray scattering for few nanometer resolution reveals shock waves and compression in intense short pulse laser irradiation of solids

Understanding how laser pulses compress solids into high-energy-density states requires diagnostics that simultaneously resolve macroscopic geometry and nanometer-scale structure. Here we present a combined X-ray imaging (XRM) and small-angle X-ray scattering (SAXS) approach that bridges this diagnostic gap. Using the Matter in Extreme Conditions end station at LCLS, we irradiated 25 μm copper wires with 45 fs, 0.9 J, 800 nm pulses at 3.5 × 10 19 W/cm 2 while probing with 8.2 keV XFEL pulses. XRM visualizes the evolution of ablation, compression, and inward-propagating fronts with ∼ 200 nm resolution, while SAXS quantifies their nanometer-scale sharpness via the time-resolved evolution of scattering streaks. The joint analysis reveals that an initially smooth compression steepens into a nanometer-sharp shock front after t sh ≈ (18 ± 3) ps, consistent with an analytical steepening model and hydrodynamic simulations. The front reaches a velocity of c sh ≈ 25 k m / s and a lateral width of several tens of microns, demonstrating direct observation of shock formation and decay at solid density for the first time with few-nanometer precision. This integrated XRM–SAXS method establishes a quantitative, multi-scale diagnostic of laser-driven shocks in dense plasmas relevant to inertial confinement fusion, warm dense matter, and planetary physics.

Kluge, Thomas [Helmholtz-Zentrum Dresden-Rossendor↗

Space telescope scientific instruments

The paper describes the Space Telescope (ST) observatory, the design concepts of the five scientific instruments which will conduct the initial observatory observations, and summarizes their astronomical capabilities. The instruments are the wide-field and planetary camera (WFPC) which will receive the highest quality images, the faint-object camera (FOC) which will penetrate to the faintest limiting magnitudes and achieve the finest angular resolution possible, and the faint-object spectrograph (FOS), which will perform photon noise-limited spectroscopy and spectropolarimetry on objects substantially fainter than those accessible to ground-based spectrographs. In addition, the high resolution spectrograph (HRS) will provide higher spectral resolution with greater photometric accuracy than previously possible in ultraviolet astronomical spectroscopy, and the high-speed photometer will achieve precise time-resolved photometric observations of rapidly varying astronomical sources on short time scales.

Leckrone, D. S.↗

Atomic-resolution imaging as a mechanistic tool for studying single-site heterogeneous catalysis

Heterogeneous catalysts dominate the chemical industry but typically feature diverse, incompletely defined active sites. Thus, describing structure-activity relationships, unlike homogeneous catalysts, remains challenging. In contrast, molecularly defined single-site heterogeneous catalysts (SSHCs), using appropriate tools, are poised to address these challenges and provide new avenues for catalysis research and development. The present study explores eco-friendly H 2 production mediated by discrete MoO 2 sites supported on carbon nanohorns (CNHs) and active for alcohol dehydrogenation. While informative, detailed ensemble EXAFS/XANES/XPS, kinetic measurements, and DFT analysis alone cannot provide a full molecular picture of the reaction pathway. Here, using single-molecule atomic-resolution time-resolved electron microscopy (SMART-EM), we propose the identification of four key catalytic intermediates anchored to CNHs and uncover a new reaction pathway involving alkoxide/hemiacetal equilibration and acetal oligomerization. Furthermore, these intermediates are inferred through a combination of theory and SMART-EM, showcasing the potential of SMART-EM as a complementary tool for exploring mechanistic hypotheses in catalysis.

36 MATERIALS SCIENCE↗

350 ps Ultrafast room-temperature scintillation realized on CsPbBr 3 -based single crystals via Br 2 over-doping

Ultrafast scintillators are essential for next-generation radiation detection, positron emission tomography, and high-speed medical imaging. All-inorganic CsPbBr 3 perovskites are attractive candidates because of their high stopping power, and excellent optical quality, yet their long carrier lifetimes result in slow scintillation responses on the order of hundreds of nanoseconds. Here, we demonstrate that controlled over-doping with Br 2 produces CsPbBr 3.03 single crystals with sub-nanosecond scintillation at room temperature while preserving crystal quality. Single crystals grown by the Bridgman method exhibit high transparency and maintain the orthorhombic perovskite structure. Br 2 over-doping induces a slight lattice expansion (about 0.42% increase in unit-cell volume) while maintaining the orthorhombic perovskite phase and high optical transparency. Optical absorption reveals a slight redshift of the absorption edge after Br 2 introduction, indicating a modified defect landscape. Time-resolved photoluminescence and radioluminescence measurements show that Br 2 doping creates dense and efficient recombination centers that reduce the scintillation decay time from more than 100 ns in undoped crystals to 350 ps under 5.486 MeV α-particle excitation, and the scintillation decay time decreases by two orders of magnitude. The doped crystals also achieve a spatial resolution of 12 lp mm −1 in X-ray imaging. These results reveal a defect-engineering route for achieving ultrafast scintillation in halide perovskites and highlight the potential of Br 2 -modified CsPbBr 3 for fast timing applications.

Li, Zongxiao [Chinese Academy of Sciences (CAS), N↗

De novo synthesis and near atomic resolution imaging of host immune receptors critical for pathogen recognition (Abbreviated Final Report)

The innate immune system serves as the body’s first line of defense against invading pathogens, responding rapidly through the deployment of immune cells at common sites of infection, such as the skin and airways. These immune-cell sentinels express a range of highly conserved receptors, including Toll-like receptors (TLRs), which recognize and bind to pathogen-derived components. This recognition event triggers intracellular signaling cascades that initiate and coordinate immune responses. Despite their significance, the complete structural characterization of full-length TLRs, including their extracellular domain (ECD), transmembrane domain (TMD), and Toll/interleukin-1 receptor (TIR) domain, remains incomplete. In this study, we examined the expression and isolation of human TLR4 incorporated into nanodiscs using two approaches: a cell-free synthesis system and a cell-based transfection strategy employing Expi293F cells derived from the human embryonic kidney lineage. Our findings demonstrate that NLP-bound human TLR4 produced via the cell-based method yielded functional protein suitable for time-resolved single-particle cryo-electron microscopy (cryo-EM). This advancement enables structural characterization of full-length TLR4, maintaining the integrity of its extracellular domain, transmembrane domain, and Toll/Interleukin-1 receptor (TIR) domain.

59 BASIC BIOLOGICAL SCIENCES↗

Fluid-Thermal-Structural Interactions Induced by an Asymmetric Shock-Wave/Boundary-Layer Interaction in a Mach-6 Compression Corner

An experimental study is conducted of the fluid-thermal-structural interaction of a clamped compliant panel exposed to a three dimensional shock-wave/boundary-layer interaction (SWBLI) induced by a Mach-6 compression ramp with a spanwise nonuniform incoming boundary layer. The nonuniform boundary layer was produced by placing trips on one side of the upstream flat plate, resulting in largely turbulent flow on the tripped side and transitional flow on the untripped side. Measurements of the flowfield confirmed that the tripped boundary layer contained elevated levels of unsteadiness, and the SWBLI was observed to vary from attached to fully separated as the ramp angle was increased from 10◦ to 38◦; the separation region on the tripped side of the panel was noticeably smaller, showing the elevated turbulence levels of the tripped-side flow to remain relatively localized rather than diffusing across the whole model. Full-field, time-resolved panel deformations were measured using high-speed photogrammetry and the vibrational response at each compression angle was characterized. Although the measured modes conformed largely to those from classical clamped-plate theory, some skewing of the mode shapes was observed. IR thermography highlighted regions of the compliant region where elevated temperatures were likely to promote thermal softening effects to the transient panel response. The quasi-static deformation and stress field was used to characterize the internal stress factor of each mode and showed a meaningful relationship between transient panel response and stress contained within each mode: modes with antinodes lying in high-stress areas of the plate tended to exhibit increases in vibrational frequency and decreases in vibrational power, whereas the opposite was true for modes with antinodes in low-stress areas.

Spectral Proper Orthogonal Decomposition↗

Collaborative R&D with REEL Solar Inc (REEL) to Understand and Overcome Performance Limitations in CdTe Solar Cells: Cooperative Research and Development (Final Report)

This CRADA will focus on processing, advanced characterization, and testing of photovoltaic materials and devices to understand and improve REEL CdTe solar technology. This will include examining process variations and different buffer, absorber, and contact layers from REEL and NLR to maximize performance. The unique and diverse advanced characterization tools at NLR, such as time-resolved photoluminescence, capacitance-voltage measurements, electron beam scattered diffraction, cathodoluminescence, electron microscopy, TOF-SIMS, and other measurements will be applied to characterize REEL processing to improve understanding and guide experimental directions. Accelerated stability and potential induced degradation tests will be used to analyze metastability, short-and-long term degradation, and improve bankability. A second and major thrust this period will be joint development of Si/CdTe tandem solar cells to overcome industry wide terrestrial solar efficiency limits with the two lowest cost and manufacturable solar materials today. This will include developing novel transparent back contacts that can be incorporated into tandem structures and other novel solar applications, detailed analysis of designs and configurations for CdTe/Si tandem modules, and prototyping REEL CdTe Technology with Si bottom cells in tandem structures.

14 SOLAR ENERGY↗

Flame stabilization in DME spray flames under engine-relevant conditions characterized by OH* chemiluminescence and formaldehyde laser-induced fluorescence

The transient and quasi-steady flame structures of Dimethyl Ether (DME) fuel sprays, produced by a single-hole injector (Spray D), were investigated using Planar Laser-Induced Fluorescence (PLIF) and chemiluminescence imaging in a constant-volume chamber under Engine Combustion Network (ECN) Spray A conditions (900 K ambient temperature, 60 bar ambient pressure, 1500 bar injection pressure, and 22.8 kg/m 3 ambient density). Low-temperature chemical reaction zones were visualized using formaldehyde (CH 2 O) PLIF with 355 nm excitation, while high-temperature flame regions were captured via chemiluminescence imaging of excited-state hydroxyl radicals (OH*). Both transient and quasi-steady flame structures clearly show the transition from CH 2 O to OH*, highlighting the progression from low- to high-temperature combustion, while the position of the flame is displaced for DME compared to reference hydrocarbon n-dodecane. Homogeneous reactor calculations with detailed chemistry and using adiabatic mixing for initial temperature show that CH 2 O peaks are significantly higher for DME at the same equivalence ratio, with a higher heat-release during the cool-flame regime with respect to the fuel heating value. Thus, the cool-flame dynamic as a precursor to high-temperature combustion and flame stabilization exhibit distinct behavior for DME relative to conventional hydrocarbons, and these phenomena are effectively resolved through the soot-free nature of DME and the high-speed, time-resolved diagnostics.

CH2O laser-induced fluorescence↗

Direct Observation of the ππ* to nπ* Transition in 2-Thiouracil via Time-Resolved NEXAFS Spectroscopy

The photophysics of nucleobases has been the subject of both theoretical and experimental studies over the past decades due to the challenges posed by resolving the steps of their radiationless relaxation dynamics, which cannot be described in the framework of the Born–Oppenheimer approximation (BOA). In this context, the ultrafast dynamics of 2-thiouracil has been investigated with a time-resolved NEXAFS study at the Free Electron Laser FLASH. Near Edge X-ray Absorption Fine Structure spectroscopy (NEXAFS) can be used to observe electronic transitions in ultrafast molecular relaxation. We performed time-resolved UV-pump/X-ray probe absorption measurements at the sulfur 2s (L1) and 2p (L2/3) edges. We are able to identify absorption features corresponding to the S2 (ππ*) and S1 (nπ*) electronic states. We observe a delay of 102 ± 11 fs in the population of the nπ* state with respect to the initial optical excitation and interpret the delay as the time scale for the S2 → S1 internal conversion. We furthermore identify oscillations in the absorption signal that match a similar observation in our previous X-ray photoelectron spectroscopy study on the same molecule.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron–Ion Covariance Reveals Geometry-Resolved Inner-Shell Spectra in CS 2 Photodissociation

The chemical shifts of inner-shell atomic orbitals are highly sensitive to chemical bonding and molecular structure. In evolving systems, however, the spectra of distinct molecular species and geometries overlap, obscuring the underlying chemical dynamics. Here we demonstrate the use of electron–ion covariance analysis to combine the structural sensitivity of Coulomb explosion imaging with inner-shell spectroscopy, yielding geometry-specific spectra of transient and product species. We apply this approach to the excited state dynamics of CS 2 probed by ionization above the S 2p edge. Electron–ion covariance with time- and momentum-selected S + and S 2+ ions isolates distinct S 2p photoelectron spectra for ground-state CS 2 , bent photoexcited CS 2 , the CS photoproduct, and bare atomic sulfur ─ species whose spectra overlap strongly in the channel-averaged measurement. Clear chemical shifts are observed in the covariance photoelectron spectrum for each of these species, all of which are consistent with high-level calculations. Here, by extracting the atomic S contribution to the photoelectron spectrum in a finely time-resolved manner we can disentangle this contribution to the overall time-resolved photoelectron spectrum as the photodissociation proceeds. These results demonstrate the promise of electron–ion covariance as a general approach to geometry-resolved inner-shell spectroscopy, opening a route to tracking structural evolution through chemical shifts in complex photoexcited molecules.

Ionization↗

Prolonging All-Optical Molecular Electron Spin Coherence in the Tissue Transparency Window

Coherent electron spin states within paramagnetic molecules hold significant potential for microscopic quantum sensing. However, all-optical coherence measurements amenable to high spatial and temporal resolution under ambient conditions remain a significant challenge. Here we conduct room-temperature, picosecond time-resolved Faraday ellipticity/rotation (TRFE/R) measurements of the electron spin decoherence time T 2 * in [IrBr 6 ] 2- . Decoherence is strongly sensitive to solution phase viscosity, pointing to molecular tumbling as an important decoherence mechanism. Accordingly, immobilization of [IrBr 6 ] 2- molecules in thin polymer films results in an order-of-magnitude increase in coherence lifetime and significantly greater magnetic field sensitivity. Here, by tuning energies of ligand-to-metal charge transfer (LMCT) states, TRFE/R enables spin initialization and readout in the tissue transparency window, paving the way toward all-optical, ultrafast molecular electron spin coherence imaging in biological systems.

Electron paramagnetic resonance spectroscopy↗

Direct observation of ultrafast symmetry reduction during internal conversion of 2-thiouracil using Coulomb explosion imaging

The photochemistry of heterocyclic molecules plays a decisive role for processes and applications like DNA photo-protection from UV damage and organic photocatalysis. The photochemical reactivity of heterocycles is determined by the redistribution of photoenergy into electronic and nuclear degrees of freedom, initially involving ultrafast internal conversion. Most heterocycles are planar in their ground state and internal conversion requires symmetry breaking. To lower the symmetry, the molecule must undergo an out-of-plane motion, which has not yet been observed directly. Here we show using the example of 2-thiouracil, how Coulomb explosion imaging can be utilized to extract comprehensive information on this molecular deformation, linking the extracted deplanarization of the molecular geometry to the previously studied temporal evolution of its electronic properties. Particularly, the protons of the exploded molecule are well-suited messengers carrying rich information on its geometry at distinct times after electronic excitation. We expect that our new analysis approach centered on these peripheral protons can be adapted as a general concept for future time-resolved studies of complex molecules in the gas phase.

Chemical physics↗

The next-generation particle x-ray temporal diagnostic for simultaneous time-resolved measurements of nuclear-burn and x-ray emission histories in support of basic-science and inertial confinement fusion experiments at OMEGA

The next-generation Particle X-ray Temporal Diagnostic (PXTD) has been implemented for simultaneous measurements of x-ray, charged particle, and neutron emission histories from a wide range of inertial confinement fusion and high energy density plasma experiments, demonstrating excellent timing accuracy and greatly improved experimental flexibility. The key changes to the previously fielded system are a redesigned set of thin foil filters in front of the scintillators and individual neutral density filters for each region of the detector. The fully implemented PXTD system can provide unique information about the evolution of ion and electron temperatures in multi-ion and kinetic-physics experiments, proton radiography experiments, and DT experiments executed at the OMEGA facility. The system has 35 ps time resolution and negligible relative timing uncertainty between measured emission history signals. The first use of the upgraded four-channel PXTD system during a set of D 3 He-filled silica-glass implosions on OMEGA captured electron temperatures with a minimum uncertainty of 0.5 keV and resolved both the relative timings and widths of neutron, proton, and x-ray peaks within a single recorded image.

Evans, T. E. [Massachusetts Inst. of Technology (M↗

Planar laser-induced fluorescence system for spatiotemporal ion velocity distribution function measurements

In this work, we present a planar laser-induced fluorescence (PLIF) system for measuring two-dimensional (2D), spatiotemporally resolved ion velocity distribution functions (IVDFs). A continuous-wave tunable diode laser produces a laser sheet that irradiates the plasma, and the resulting fluorescence is captured by an intensified CCD (ICCD) camera. Fluorescence images recorded at varying laser wavelengths are converted into 2D IVDFs using the Doppler shift principle. The developed diagnostic is implemented in an electron beam generated E × B plasma with a bulk plasma density of $\sim\!\!{10^{10}}{\text{c}}{{\text{m}}^{ - 3}}$ . The developed diagnostic is validated against a conventional single-point LIF method using photomultiplier tube-based detection, while significantly reducing the total measurement time by the number of spatial positions measured. The time-resolving capability of this diagnostic is tested by oscillating the plasma between two nominal operating modes with different density profiles and triggering the ICCD camera by the externally driven plasma oscillation. The measured 2D IVDF maps reveal several signatures of ion dynamics in this plasma source, including radially outflowing ions across the electric field and anomalous ion heating at the periphery, consistent with recent kinetic simulations and theoretical studies. A possible correlation between these ion kinetic features and rotating spoke structures is discussed.

E×B plasma↗

Hard x-ray imaging and characterization of staged z-pinch plasmas in order to exclude ion beams as cause of fusion

Prior to the start of the INFUSE project, a 1-D x-ray device had been developed to detect > 5 keV x-rays and, by using the device as a pinhole camera, determine the location of the source of these x-rays. The system was also used in a non-camera mode to measure the energy of the X-rays by having different thicknesses of attenuating material on different pixels. This dual-purpose had been used in three plasma experiments: the laboratory magnetized plasma jet at Caltech, the laboratory solar nanoflare at Caltech, and at the 500 kA staged Z-pinch (CESZAR) at UCSD. Preliminary measurements at the UCSD facility indicated that hard x-rays with energies ranging from ~27 to over 100 keV were created and that these x-rays likely originated at the Z-pinch’s anode. These preliminary data also indicated that the x-rays’ origin was coincident with the moment of peak compression. The major goal of the INFUSE proposal was to confirm these preliminary results. This confirmation was to be made by improving the imaging capability to two dimensions, increasing the time resolution of the camera, and using the x-ray diagnostic alongside time-resolved neutron detectors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗