Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time-resolved reflection spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

81 records · Page 5

Hot-carrier dynamics in InAs/AlAsSb multiple-quantum wells

A type-II InAs/AlAs 0.16 Sb 0.84 multiple-quantum well sample is investigated for the photoexcited carrier dynamics as a function of excitation photon energy and lattice temperature. Time-resolved measurements are performed using a near-infrared pump pulse, with photon energies near to and above the band gap, probed with a terahertz probe pulse. The transient terahertz absorption is characterized by a multi-rise, multi-decay function that captures long-lived decay times and a metastable state for an excess-photon energy of >100 meV. For sufficient excess-photon energy, excitation of the metastable state is followed by a transition to the long-lived states. Excitation dependence of the long-lived states map onto a nearly-direct band gap (E g ) density of states with an Urbach tail below E g . As temperature increases, the long-lived decay times increase < E g , due to the increased phonon interaction of the unintentional defect states, and by phonon stabilization of the hot carriers > E g . Additionally, Auger (and/or trap-assisted Auger) scattering above the onset of the plateau may also contribute to longer hot-carrier lifetimes. Meanwhile, the initial decay component shows strong dependence on excitation energy and temperature, reflecting the complicated initial transfer of energy between valence-band and defect states, indicating methods to further prolong hot carriers for technological applications.

14 SOLAR ENERGY↗

Photoinduced structural distortions and singlet–triplet intersystem crossing in Cu(I) MLCT excited states monitored by optically gated fluorescence spectroscopy

Copper(I) phenanthroline complexes reflect viable earth-abundant alternatives to the ubiquitous Ru(II) tris-bipyridine photosensitizers owing to their similar metal-to-ligand charge transfer (MLCT) properties. A well-established complication of Cu(I) phenanthroline complexes is that they can undergo significant photo-induced structural rearrangements, leading to excited states that are highly susceptible to exciplex formation and short-lived. In this work, a comprehensive analysis of the photo-induced structural distortions and singlet–triplet intersystem crossing dynamics of a series of four sterically encumbered Cu(I) phenanthroline chromophores has been conducted, namely, [Cu(dsbp) 2 ] + (dsbp = 2,9-di-sec-butyl-1,10-phenanthroline), [Cu(dsbtmp) 2 ] + (dsbtmp = 2,9-di-sec-butyl-3,4,7,8-tetramethyl-1,10-phenanthroline), [Cu(dipp) 2 ] + (dipp = 2,9-di-isopropyl-1,10-phenanthroline), and [Cu(diptmp) 2 ] + (diptmp = 2,9-di-isopropyl-3,4,7,8-tetramethyl-1,10-phenanthroline). Upconverted fluorescence decay kinetics were measured at wavelengths along the blue side of the photoluminescence spectrum. The experimental results displayed strong wavelength dependence of the singlet emission, with rapid sub-picosecond decay dominating at higher energies. At lower emission energies, increasing contribution of a longer decay component was revealed. This wavelength dependence is a signature of the excited state structural rearrangement of the phenanthroline ligands which concomitantly lower the excited state energy. The obtained time constants were in excellent agreement with those measured in the complementary ultrafast transient absorption experiments. The sub-picosecond component (prompt fluorescence) is associated with the photo-induced structural rearrangement that lowers the energy of the singlet excited state. The longer decay component represents the lifetime of the S 1 excited state, and thus the time-scale of singlet–triplet intersystem crossing. Lastly, the observed dual emission was further characterized by constructing picosecond time-resolved emission spectra from the measured kinetic data. These qualitative luminescence spectra capture the resulting emission from both the S 1 initial state and the S 1 flattened state, offering additional insight into the energy-lowering excited state distortion across the series.

14 SOLAR ENERGY↗

Coherent phonon spectroscopy of non-fully symmetric modes using resonant terahertz excitation

We use intense terahertz (THz) frequency electromagnetic pulses generated via optical rectification in an organic crystal to drive vibrational lattice modes in single crystal Tellurium. The coherent modes are detected by measuring the polarization changes of femtosecond laser pulses reflecting from the sample surface, resulting in a phase-resolved detection of the coherent lattice motion. We compare the data to a model of Lorentz oscillators driven by the near-single-cycle broadband THz pulse. The demonstrated technique of optically probed coherent phonon spectroscopy with THz frequency excitation could prove to be a viable alternative to other time-resolved spectroscopic methods like standard THz time domain spectroscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The ultrafast Kerr effect in anisotropic and dispersive media

The ultrafast optical Kerr effect (OKE) is widely used to investigate the structural dynamics and interactions of liquids, solutions, and solids by observing their intrinsic nonlinear temporal responses through nearly collinear four-wave mixing. Non-degenerate mixing schemes allow for background free detection and can provide information on the interplay between a material’s internal degrees of freedom. Here, we show a source of temporal dynamics in the OKE signal that is not reflective of the internal degrees of freedom but arises from a group index and momentum mismatch. It is observed in two-color experiments on condensed media with sizable spectral dispersion, a common property near an optical resonance. In particular, birefringence in crystalline solids is able to entirely change the character of the OKE signal via the off-diagonal tensor elements of the nonlinear susceptibility. We develop a detailed description of the phase-mismatched ultrafast OKE and show how to extract quantitative information on the spectrally resolved birefringence and group index from time-resolved experiments in one and two dimensions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

All-optical control of charge transfer and interlayer excitons in transition metal dichalcogenide heterostructures

An all-optical approach to control interlayer charge transfer and interlayer exciton dynamics is demonstrated using transition metal dichalcogenide heterostructures of MoSe 2 /MoS 2 and MoSe 2 /WS 2 as examples. In the three-pulse pump-probe experiments, a control pulse injects photocarriers and produces an electric field due to the interlayer charge separation. A pump pulse excites new carriers and their dynamics under the influence of the control-injected carriers and field is time-resolved by measuring differential reflectance of a third probe pulse. In MoSe 2 /MoS 2 , the interlayer electron transfer time from MoSe 2 to MoS 2 decreases with increasing the control-injected carrier density and electric field. The dipole moment of the interlayer excitons is reduced by the control pulse, which can be utilized for ultrafast and all-optical control of interlayer excitons. The recombination of the interlayer excitons is enhanced by the control pulse, which increases the spatial overlap of the electron and hole wave functions. The effect of the control pulse on the interlayer excitons is confirmed in the MoSe 2 /WS 2 heterostructure, although its effect on the electron transfer time is not resolvable. Furthermore, these results reveal useful information to understand and control interlayer charge transfer dynamics and provide tools for ultrafast manipulation of electrons in van der Waals heterostructures.

36 MATERIALS SCIENCE↗

ATR-SEIRAS Method to Measure Interfacial pH during Electrocatalytic Nitrate Reduction on Cu

This study reports the accuracy and applications of an attenuated total reflectance–surface-enhanced infrared absorption spectroscopy (ATR–SEIRAS) technique to indirectly measure the interfacial pH of the electrolyte within 10 nm of the electrocatalyst surface. This technique can be used in situ to study aqueous electrochemical reactions with a calibration range from pH 1–13, time resolution down to 4 s, and an average 95% confidence interval of 14% that varies depending on the pH region (acidic, neutral, or basic). The method is applied here to electrochemical nitrate reduction at a copper cathode to demonstrate its capabilities, but is broadly applicable to any aqueous electrochemical reaction (such as hydrogen evolution, carbon dioxide reduction, or oxygen evolution) and the electrocatalyst may be any SEIRAS-active thin film (e.g., silver, gold, or copper). The time-resolved results show a dramatic increase in the interfacial pH from pH 2–7 in the first minute of operation during both constant current and pulsed current experiments where the bulk pH is unchanged. Attempts to control the pH polarization at the surface by altering the electrochemical operating conditions—lowering the current or increasing the pulse frequency—showed no significant change, demonstrating the challenge of controlling the interfacial pH.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

STROBE-X: X-Ray Timing Spectroscopy on Dynamical Timescales from Microseconds to Years

We describe a probe-class mission concept that provides an unprecedented view of the X-ray sky, performing timing and 0.2-30 keV spectroscopy over timescales from microseconds to years. The Spectroscopic Time-Resolving Observatory for Broadband Energy X-rays (STROBE-X) comprises three primary instruments. The first uses an array of lightweight optics (3-m focal length) that concentrate incident photons onto solid state detectors with CCD-level (85-130 eV) energy resolution, 100 ns time resolution, and low background rates to cover the 0.2-12 keV band. This technology is scaled up from NICER, with enhanced optics to take advantage of the longer focal length of STROBE-X. The second uses large-area collimated silicon drift detectors, developed for ESA's LOFT, to cover the 2-30 keV band. These two instruments each provide an order of magnitude improvement in effective area compared with its predecessor (NICER and RXTE, respectively). Finally, a sensitive sky monitor triggers pointed observations, provides high duty cycle, high time resolution, high spectral resolution monitoring of the X-ray sky with approx. 20 times the sensitivity of the RXTE ASM, and enables multi-wavelength and multi-messenger studies on a continuous, rather than scanning basis.For the first time, the broad coverage provides simultaneous study of thermal components, non-thermal components, iron lines, and reflection features from a single platform for accreting black holes at all scales. The enormous collecting area allows detailed studies of the dense matter equation of state using both thermal emission from rotation-powered pulsars and harder emission from X-ray burst oscillations. The combination of the wide-field monitor and the sensitive pointed instruments enables observations of potential electromagnetic counterparts to LIGO and neutrino events. Additional extragalactic science, such as high quality spectroscopy of clusters of galaxies and unprecedented timing investigations of active galactic nuclei, is also obtained.

STROBE-X X-ray↗

STROBE-X: X-ray Timing & Spectroscopy on Dynamical Timescales from Milliseconds to Years

We describe a probe-class mission concept that provides an unprecedented view of the X-ray sky, performing timing and 0.2-30 keV spectroscopy over timescales from microseconds to years. The Spectroscopic Time-Resolving Observatory for Broadband Energy X-rays (STROBE-X) comprises three primary instruments. The first uses an array of lightweight optics (3-m focal length) that concentrate incident photons onto solid state detectors with CCD-level (85-130 eV) energy resolution, 100 ns time resolution, and low background rates to cover the 0.2-12 keV band. This technology is scaled up from NICER [1], with enhanced optics to take advantage of the longer focal length of STROBE-X. The second uses large-area collimated silicon drift detectors, developed for ESA's LOFT [2], to cover the 2-30 keV band. These two instruments each provide an order of magnitude improvement in effective area compared with its predecessor (NICER and RXTE, respectively). Finally, a sensitive sky monitor triggers pointed observations, provides high duty cycle, high time resolution, high spectral resolution monitoring of the X-ray sky with approx. 20 times the sensitivity of the RXTE ASM, and enables multi-wavelength and multi-messenger studies on a continuous, rather than scanning basis. For the first time, the broad coverage provides simultaneous study of thermal components, non-thermal components, iron lines, and reflection features from a single platform for accreting black holes at all scales. The enormous collecting area allows detailed studies of the dense matter equation of state using both thermal emission from rotation-powered pulsars and harder emission from X-ray burst oscillations. The combination of the wide-field monitor and the sensitive pointed instruments enables observations of potential electromagnetic counterparts to LIGO and neutrino events. Additional extragalactic science, such as high quality spectroscopy of clusters of galaxies and unprecedented timing investigations of active galactic nuclei, is also obtained

STROBE-↗

Shock Tube Characterization of Laser Absorption Sensors for Combustion Measurements of Green Propellants

Chemical kinetic models for green spacecraft propulsion systems are needed to calculate efficiency, estimate toxic products, and mitigate plume impingement risks. Laser absorption spectroscopy (LAS) is a common technique used to measure time-resolved mole fraction for model validation. LAS was used to measure species-time history nitrous oxide (N2O) and carbon monoxide (CO) behind reflected shock waves. The diagnostics were implemented at the University of Central Florida high-pressure shock tube facility. A mixture of ethylene (0.002) and N2O (0.008) was diluted with argon gas (0.99) and shock heated 12 bar and temperatures from 1400 to 1600 K.

Marley A. Albright↗