Search NASASearch

SEARCH · Search NASA

Results for “Timing resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Capturing Ring Opening in Photoexcited Enolic Acetylacetone upon Hydrogen Bond Dissociation by Ultrafast Electron Diffraction

Photoinduced biological and chemical reactions are often based on key structural transformations of a molecule driven across multiple electronic states. Acetylacetone (AcAc) is a prototypical system for complex chemical pathways involving several conical intersections (CI) and singlet–triplet intersystem crossings (ISC) characterized by distinct geometries. In the gas phase, AcAc is predominantly in a planar ring-like enolic form stabilized by a strong intramolecular O–H···O hydrogen bond. Following excitation into the S 2 (ππ*) state at 266 nm, acetylacetone undergoes rapid internal conversion followed by intersystem crossing. Such relaxation pathways are associated with structural changes including ring opening, deplanarization, and bond elongation. In this work, ultrafast electron diffraction (UED) at the SLAC MeV-UED setup is employed as a direct structural probe with a time resolution of 160 fs. Together with trajectory surface hopping simulations, analysis of the UED data provides a new perspective on the early time nuclear dynamics in acetylacetone. Specifically, AcAc is observed to undergo ring opening, deplanarization, and bond elongation all within the first 700 fs after photoexcitation. The monitored dynamics is associated mainly with the nuclear motion on the S 1 potential energy surface, formed after very rapid transfer from S 2 to S 1 , allowing AcAc to reach the conical intersection to intersystem crossing. Such time scales of nuclear motion are contrasted with the time scales of electronic transitions in AcAc that were previously characterized with spectroscopic methods, specifically internal conversion (<100 fs) and intersystem crossing (∼1.5 ps).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Raw ERCOT 60-Day SCED Disclosure Reports

This dataset contains ERCOT plant-level wind power production data at a 15-minute time resolution. Data at ERCOT are called 60-Day SCED Disclosure Report; data product number NP3-965-ER. Raw data are in local time. DST is handled as "skip hour" (12a, 1a, 3a,...) in spring, "extra hour" (12a, 1a, 2a, 2a, 3a,...) in fall.

17 WIND ENERGY

Quantum Instrumentation and Control Kit (QICK) for Quantum Networks

We report the first demonstration of using the Quantum Instrumentation and Control Kit (QICK) system on RFSoC FPGA technology to drive an entangled photon pair source and to detect the photon signals. With the QICK system, we achieve high levels of performance metrics including coincidence-to-accidental ratio exceeding 150, and entanglement visibility exceeding 95%, consistent with performance metrics achieved using conventional waveform generators. We also demonstrate simultaneous detector readout using the digitization functional of QICK, achieving internal system synchronization time resolution of 3.2 ps. The work reported in this paper represents an explicit demonstration of the feasibility for replacing commercial waveform generators and time taggers with RFSoC-FPGA technology in the operation of a quantum network, representing a cost reduction of more than an order of magnitude.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Implementing Superresolution of Nonstationary Tides with Wavelets: An Introduction to CWT_Multi

Abstract Tides are often nonstationary due to nonastronomical influences. Investigating variable tidal properties implies a trade-off between separating adjacent frequencies (using long analysis windows) and resolving their time variations (short analysis windows). Previous continuous wavelet transform (CWT) tidal methods resolved tidal species. Here, we present CWT_Multi, a MATLAB code that 1) uses CWT linearity (via the “response coefficient method”) to implement superresolution, i.e., resolving tidal constituents beyond the Rayleigh criterion; 2) provides a Munk–Hasselmann constituent selection criterion appropriate for superresolution; and 3) introduces an objective, time-variable form of inference (“dynamic inference”) based on time-varying data properties. CWT_Multi resolves tidal species on time scales of days, and multiple constituents per species with fortnightly filters. It outputs astronomical phase lags and admittances, analyzes multiple records, and provides power spectra of the signal(s), residual(s), and reconstruction(s); confidence limits; and signal-to-noise ratios. Artificial data and water levels from the Lower Columbia River Estuary (LCRE) and San Francisco Bay Delta (SFBD) are used to test CWT_Multi and compare it to harmonic analysis programs NS_Tide and UTide. CWT_Multi provides superior reconstruction, detiding, dynamic analysis utility, and time resolution of constituents (but with broader confidence limits). Dynamic inference resolves closely spaced constituents (like K 1 , S 1 , and P 1 ) on fortnightly time scales, quantifying impacts of diel power peaking (with a 24-h period, like S 1 ) on water levels in the LCRE. CWT_Multi also helps quantify the impacts of high flows and a salt barrier closing on tidal properties in the SFBD. On the other hand, CWT_Multi does not excel at prediction, and results depend on analysis details, as for any method applied to nonstationary data. Significance Statement Ocean tides, especially in coastal and estuarine systems, are often nonstationary, in the sense that the mean and standard deviation of tidal properties vary over time, usually in response to some nontidal process. We introduce here a MATLAB code, CWT_Multi, that uses wavelet transforms to resolve both tidal species and constituents on time scales from a few days to months. Our code accommodates multiple scalar time series and has typical tidal analysis features like constituent selection and inference, plus two forms of uncertainty analyses. It is flexible, allowing the user to adapt analysis properties to diverse datasets. CWT_Multi is applicable to many problems involving time-variable tides, including sea level rise, compound flooding, sediment transport, and wetland habitat analyses. Application to vector data is a straightforward extension, but further development of our uncertainty analysis is merited. Because nonstationary tidal analysis is rapidly advancing, we also define the features of a “well-formed” analysis code.

Lobo, Matthew

ADRIANO2 Calorimeter Performance from 2022 Test Beams

A novel high-granularity dual-readout calorimetric technique was developed as part of the T1604 collaboration. The ADRIANO2 Calorimeter Prototype consists of a pair of optically isolated, small sized tiles made of scintillating plastic and lead glass. Čerenkov light from the lead glass are exploited to for high resolution timing measurements, while high granularity from scintillating plastic can be used to probe the spatial component of the particle shower. This setup works for excellent energy resolution and particle detection for REDTOP as it is crucial for a calorimeter to detect the decay products of eta/eta-prime mesons. Measurements were collected on ADRIANO2 between February to December 2022 to evaluate the detector performance at Fermilab’s Test Beam Facility. The key metrics extracted from my analysis are the detector’s efficiency for various tile configuration and light-yield which will then be used as parameters for an upgraded REDTOP monte-carlo simulation campaign. An in-depth analysis of ADRIANO2 performance are detailed in this presentation.

43 PARTICLE ACCELERATORS

Response of fs-Laser-Irradiated Diamond by Ultrafast Electron Diffraction

Structural details of the proposed solid–liquid phase transition of carbon have remained elusive, despite years of study. While it is theorized that novel carbon materials form from a liquid precursor, experimental studies have lacked the temporal and spatial resolution necessary to fully characterize the purported liquid state. Here, in this work, we utilize megaelectronvolt-ultrafast electron diffraction (MeV-UED) to study laser irradiated submicron diamond thin films in a pump–probe scheme with picosecond time resolution to visualize potential structural changes of excited diamond. We probe the structure of diamond using a combination of fluences (13, 40 J/cm 2 ) and time delays (10, 25, 100 ps), but observe negligible changes in the static diffraction pattern of diamond and an overall decrease in diffraction intensity up to 100 ps after the excitation pulse. We thus conclude that no appreciable amount of liquid or graphitized carbon is present and highlight the structural resilience of bulk diamond to intense 800 nm ultrafast laser pulses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

The CMS Phase-2 Fast Beam Condition Monitor prototype test with beam

The Fast Beam Condition Monitor (FBCM) is a standalone luminometer for the High Luminosity LHC (HL-LHC) program of the CMS Experiment at CERN. The detector is under development and features a new, radiation-hard, front-end application-specific integrated circuit (ASIC) designed for beam monitoring applications. The achieved timing resolution of a few nanoseconds enables the measurement of both the luminosity and the beam-induced background. The ASIC, called FBCM23, features six channels with adjustable shaping times, enabling in-field fine-tuning. Each ASIC channel outputs a single binary asynchronous signal encoding time-of-arrival and time-over-threshold information. The FBCM is based on silicon-pad sensors, with two sensor designs presently being considered. This paper presents the results of tests of the FBCM detector prototype using both types of silicon sensors with hadron, muon, and electron beams. Irradiated FBCM23 ASICs and silicon-pad sensors were also tested to simulate the expected conditions near the end of the detector's lifetime in the HL-LHC radiation environment. Based on test results, direct bonding between the sensor and ASIC was chosen, and an optimal bias voltage and ASIC threshold for FBCM operation were proposed. The current design of the front-end test board was validated following the beam test and is now being used for the first front-end module, which is expected to be produced in summer 2025. These results represent a major step forward in validating the FBCM concept, first version of the firmware and establishing a reliable design path for the final detector.

Beam-line instrumentation (beam position and profi

Double diffraction imaging of x-ray induced structural dynamics in single free nanoparticles

Abstract Because of their high photon flux, x-ray free-electron lasers (FEL) allow to resolve the structure of individual nanoparticles via coherent diffractive imaging (CDI) within a single x-ray pulse. Since the inevitable rapid destruction of the sample limits the achievable resolution, a thorough understanding of the spatiotemporal evolution of matter on the nanoscale following the irradiation is crucial. We present a technique to track x-ray induced structural changes in time and space by recording two consecutive diffraction patterns of the same single, free-flying nanoparticle, acquired separately on two large-area detectors opposite to each other, thus examining both the initial and evolved particle structure. We demonstrate the method at the extreme ultraviolet (XUV) and soft x-ray Free-electron LASer in Hamburg (FLASH), investigating xenon clusters as model systems. By splitting a single XUV pulse, two diffraction patterns from the same particle can be obtained. For focus intensities of about 2 × 10 12 W cm −2 we observe still largely intact clusters even at the longest delays of up to 650 picoseconds of the second pulse, indicating that in the highly absorbing systems the damage remains confined to one side of the cluster. Instead, in case of five times higher flux, the diffraction patterns show clear signatures of disintegration, namely increased diameters and density fluctuations in the fragmenting clusters. Future improvements to the accessible range of dynamics and time resolution of the approach are discussed.

Sauppe, M. (ORCID:0000000163123102)

Precision Timing in CMS at the HL-LHC: Current Progress on Validation and Production

During the High Luminosity phase of LHC, up to 200 proton-proton collisions per bunch crossing will bring severe challenges for event reconstruction. To mitigate pileup effects, an extended upgrade program of the CMS experiment is expected. Among which, a new timing layer, the MIP Timing Detector (MTD), will be integrated between the tracker and the calorimeters. With a time resolution of 30-60 ps, the MTD will enable 4D vertexing, bringing significant improvements in track-to-vertex association and object identification. The MTD is composed of two subsystems based on different technologies: the Barrel Timing Layer (BTL) consists of LYSO:Ce scintillating crystals readout by SiPMs, and the Endcap Timing Layer (ETL) is made of Low-Gain Avalanche Diodes. The BTL is currently under production, while ETL sensor prototyping and validation are ongoing. Recent system tests have confirmed the performance of the full acquisition chain. This talk will provide an overview of the MTD design, along with the physics motivation, and the current status of BTL construction and ETL development.

Safdari, Murtaza [Fermilab] (ORCID:000000018323731

High resolution measurements of core density collapse dynamics in LHD

The core density collapse (CDC) is an abrupt instability that degrades the performance of super dense core stellarator plasmas on the Large Helical Device (LHD). In LHD, CDCs have proved to be an operational limit in so-called outward-shifted configurations. New measurements with high time resolution Thomson scattering characterize dynamics of the instability in the core. The density profile is observed to collapse inwards, narrowing the density peak till the core itself collapses. A hot, radially localized feature is also observed in the electron temperature profile during the collapse and disappears within a few hundred microseconds of CDC onset.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

NPFTURBULENCE: Best Estimate Aerosol Size Distribution by airborne measurements

The original data were collected during the field campaign of “Turbulent layers promoting New Particle Formation” experiment (NPFTURBULENCE; https://www.arm.gov/research/campaigns/aaf2024npfturbulence) over the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) Atmospheric Observatory (https://www.arm.gov/capabilities/observatories/sgp ) in north-central Oklahoma. The ARM Aerial Facility ArcticShark uncrewed aerial system (UAS) was based at Blackwell–Tonkawa Municipal Airport (IATA: BWL, ICAO: KBKN, FAA LID: BKN, 36.74475° N, 97.34918° W, 313.9 m MSL), for the field campaign from May 5 through May 29, 2024. The ArcticShark UAS performed 11 flights, including 10 research flights over the Central Facility of the ARM SGP to measure atmospheric state, turbulence, surface IT temperature and imagery, aerosol number concentration and size distribution. The current data set presents Best Estimate Aerosol Size Distribution: a merged aerosol size distribution composed of the data from 2 sensors: miniaturized Scanning Electrical Mobility Sizer (mSEMS) and Portable Optical Particle Spectrometer (POPS). The mSEMS data were interpolated to 1 second from “native” time resolution of about 15 second to match the other probe. The POPS data were converted from equivalent optical size into geometric size using value of aerosol refractive index of 1.477 from the HISCALE field campaign (same geographical area, altitudes, and time of year; http://www.arm.gov/campaigns/aaf2016hiscale ).

54 ENVIRONMENTAL SCIENCES

Undulator radiation of single electrons: coherence length and quantum-optical properties

The aims of the CLARA experiment at the Fermilab Integrable Optics Test Accelerator (IOTA) were to directly measure the coherence length of undulator radiation emitted by a single electron and to test whether the radiation is in a pure classical Glauber coherent state or in a quantum mixture of coherent and Fock states. We used a Mach-Zehnder interferometer (MZI) to study visible radiation generated by 150-MeV electrons circulating in the ring. The relative delay between the two arms of the MZI was adjusted by varying the length of one of them with a resolution of 10 nm. The intensity of the circulating beam spanned several orders of magnitude, down to single electrons. A pair of single-photon avalanche diodes (SPADs) was placed at the output of the MZI arms to detect photocounts with high efficiency and timing resolution. We describe the observed interference patterns and photocount rates as a function of interferometer delay and discuss their implications.

43 PARTICLE ACCELERATORS

Undulator Radiation of Single Electrons: Coherence Length and Quantum-Optical Properties

The aims of the CLARA experiment at the Fermilab Integrable Optics Test Accelerator (IOTA) were to directly measure the coherence length of undulator radiation emitted by a single electron and to test whether the radiation is in a pure classical Glauber coherent state or in a quantum mixture of coherent and Fock states. We used a Mach-Zehnder interferometer (MZI) to study visible radiation generated by 150-MeV electrons circulating in the ring. The relative delay between the two arms of the MZI was adjusted by varying the length of one of them with a resolution of 10 nm. The intensity of the circulating beam spanned several orders of magnitude, down to single electrons. A pair of single-photon avalanche diodes (SPADs) was placed at the output of the MZI arms to detect photocounts with high efficiency and timing resolution. We describe the observed interference patterns and photocount rates as a function of interferometer delay and discuss their implications.

43 PARTICLE ACCELERATORS

XFEL SASE pulses can enhance time-dependent observables

Abstract X-ray free electron lasers (XFELs) have emerged as powerful sources of short and intense x-ray pulses. We propose a simple and robust procedure which takes advantage of the inherent stochasticity of self-amplified stimulated emission (SASE) pulses to enhance the time-resolution and signal strength of the recorded data. Notably, the proposed method is able to enhance the average signal without knowledge of the signal strength of individual shots. Simple metrics for the probe pulses are introduced, such as an effective pulse duration applicable to SASE pulses characterised in the time domain using e.g. an X-band transverse cavity. The approach is evaluated using simulated and real pulse data in the context of ultrafast electron dynamics in a molecule. Utilising H 2 as a model system, we demonstrate the efficacy of the method theoretically, successfully enhancing the predicted nonresonant ultrafast x-ray scattering signal associated with electron dynamics. The method presented is broadly applicable and offers a general strategy for enhancing time-dependent observables at XFELs.

data analysis

Characterization of a SiPM-based monolithic neutron scatter camera using dark counts

The Single Volume Scatter Camera (SVSC) Collaboration aims to develop portable neutron imaging systems for a variety of applications in nuclear non-proliferation. Conventional double-scatter neutron imagers are composed of several separate detector volumes organized in at least two planes. A neutron must scatter in two of these detector volumes for its initial trajectory to be reconstructed. As such, these systems typically have a large footprint and poor geometric efficiency. We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm×56 mm× 60 mm monolithic block of EJ-204 plastic scintillator instrumented on two faces with arrays of 64 Hamamatsu S13360-6075PE silicon photomultipliers (SiPMs). The electronic crosstalk is limited to < 5% between adjacent channels and < 0.1% between all other channel pairs. SiPMs introduce a significantly elevated dark count rate over PMTs, as well as correlated noise from after-pulsing and optical crosstalk. In this article, we characterize the dark count rate and optical crosstalk and present a modified event reconstruction likelihood function that accounts for them. We find that the average dark count rate per SiPM is 4.3 MHz with a standard deviation of 1.5 MHz among devices. The analysis method we employ to measure internal optical crosstalk also naturally yields the mean and width of the single-electron pulse height. Here, we calculate separate contributions to the width of the single-electron pulse-height from electronic noise and avalanche fluctuations. We demonstrate a timing resolution for a single-photon pulse to be (128 ± 4) ps. Finally, coincidence analysis is employed to measure external (pixel-to-pixel) optical crosstalk. We present a map of the average external crosstalk probability between 2×4 groups of SiPMs, as well as the in-situ timing characteristics extracted from the coincidence analysis. Further work is needed to characterize the performance of the camera at reconstructing single- and double-site interactions, as well as image reconstruction.

47 OTHER INSTRUMENTATION

Beam test results for the Endcap Timing ReadOut Chip (ETROC2) for the CMS ETL upgrade

The Endcap Timing ReadOut Chip (ETROC) for the Compact Muon Solenoid (CMS) Minimum ionizing particle Timing Detector (MTD) is designed to process Low Gain Avalanche Diode (LGAD) signals with a time resolution of 40-50ps per hit, with 30-35 ps per charged particle using two layer detector. The ETROC2, is the first full size (16x16 pixels) and full functionally design that has been tested in hadron and electron beams at CERN and DESY (Sep 2023 - June 2024). Precision timing studies at these test beams are done using a self-referential beam telescope composed of up to 4 layers/chips. This talk describes the ETROC2 beam telescope and summarizes the performance of the ETROC2 chips bump-bonded to (16x16) Fondazione Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) LGAD sensors using results from recent test beams. The experiences and lessons learned during the course of these test beams are also detailed in this talk.

Safdari, Murtaza

Low Energy Neutron-induced Charged-particle (Z) (LENZ) instrument development with a focus on pulse shape discrimination for low-energy charged particles

To study neutron-induced charged-particle reactions with high precision, the Low Energy Neutron-induced Charged-particle (Z) instrument (LENZ) was developed at the Los Alamos Neutron Science Center. For the interest of measuring (n,p) and (n, α) reactions simultaneously, Pulse Shape Discrimination methods were investigated to identify different charged particles in the energy range of 3 - 20 MeV and improve signal-to-background ratios using Double-sided Silicon Strip Detectors and waveform digitizers. The risetime and pulse shape properties of detected charged particles were characterized for various silicon detector’s thickness with different orientations. During the post-processing of waveforms, we implemented different digital filters for effective particle identifications and improved energy- and timing- resolutions. We validated the optimized digital filters and pulse shape analyses, via measurements with 228 Th and 229 Th calibration sources, proton-induced reactions on a 7 LiF target, and neutron-induced reactions on CH 2 , Ta 2 O 5 , 58 Ni, and 6 LiF/ 59 Ni targets at the time-of-flight facility, LANSCE. In conclusion, the summary of effective thresholds and Figure of Merits on separating different charged particles is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Single-shot ultrafast dynamics of nanosecond pulsed plasmas: Transition from ps–ns nonequilibrium to near-full ionization

The ultrafast multi-stage evolution of state-defining properties in atmospheric-pressure nanosecond pulsed plasmas is quantified using single-discharge, jitter-free, continuous streak-sweep spectroscopy of N 2 (C → B) molecular and N + /O + ionic species with a single-shot time resolution as short as ∼160 ps. An early period of extreme nonequilibrium is observed with vibrational temperatures [T V (C)] dropping from ∼8000 K at <200 ps after plasma breakdown to <4000 K within ∼1 ns, with near-ambient rotational temperatures [T R (C)] ∼ 300 K due to limited collisional energy transfer. This early-time T V (C) trend is representative of a direct and unquenched look into the high-energy tail of the electron energy distribution function; thus, it tracks real-time changes in the mean electron energy via the N2(C) emission signatures. This is followed by the rapid onset of N + /O + ionic emission after a distinct time delay of ∼14.9 ns due to multistep chemical kinetics. The ionic emission enables determination of electron densities (n e ) >2 × 10 19 cm −3 and electron temperatures (T e ) >36 000 K, indicating the transition to a nearly fully ionized regime. The ps–ns temporal dynamics are also compared between air and N 2 plasmas to assess the influence of collisional partners, as well as across the anode, cathode, and central gap regions to identify spatial variations in plasma behavior. Finally, this work demonstrates versatile continuously probing approach capable of spectro-temporal and spatially resolved single-shot measurements of key state variables in the ps–ns evolution of atmospheric-pressure nanosecond pulsed plasmas.

Electric discharges