Search NASA⌕ Search

SEARCH · Search NASA

Results for “Timing spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Splitting photons: Singlet fission in nanocrystal-molecule hybrid structures

The goal of this research is to enable all the energy contained in sunlight to be harvested by making full use of the energy contained in the blue and green wavelengths of light. Current systems are unable to extract all of the energy available from photons in this wavelength range due to rapid relaxation processes that dissipate a fraction of the energy as heat. In this work, inexpensive, earth-abundant components capable of supporting multi-excitonic processes involving more than one tightly bound excited state are investigated as a way to exceed the Shockley-Queisser limit. This research will examine hybrid organic-inorganic nanostructures capable of singlet fission, a process by which one high-energy spin-singlet state is converted into two lower-energy spin-triplet states, and subsequent triplet exciton transfer. Specifically, the organic molecules diphenylhexatriene and tetracene that maximally absorb blue light and are known to exhibit singlet fission will be bound to lead chalcogenide nanocrystals. A variety of steady-state and time-resolved spectroscopic techniques will be used to study the transfer of energy from spin-triplet excitons that are created in the organic molecules to the nanoparticle acceptors. The hybrid nanostructures here will be fully characterized both in solution or thin film via electronic absorption and photoluminescence spectroscopy, nuclear magnetic resonance spectroscopy, high-resolution mass spectrometry, transmission electron microscopy, photoelectron spectroscopy, time correlated single photon counting and transient absorption experiments. The effect of molecular and nanocrystal structure on the electronic coupling between the hybrid components will be examined to establish fundamental relationships between structure and triplet energy transfer efficiency. The findings will be directly applicable to a potential tetracene-silicon platform that may ultimately enhance the power conversion efficiency of silicon solar cells.

30 DIRECT ENERGY CONVERSION↗

Radiation-induced transients on solid and molten Li and K iodides

The study, quantification, and monitoring of iodine in nuclear power generation systems have been paramount due to its environmental and health implications. Thorough speciation and transport studies strengthened the development and deployment of water reactors, which are now required for the new generation of Molten Salt Reactors (MSR), where the fuel and coolant are a complex liquid system of suitable halides. The speciation, radiation-induced chemistry, and transport of iodine (I-127, I-129 and I-131) under extreme conditions of temperature and ionizing radiation are among the challenges for the future implementation of MSR’s. In aqueous systems, the triiodide-iodine-iodide (I3--I2-I-) equilibrium is strongly dependent on the conditions of the medium. In molten iodides and chlorides, the triiodide detection (and its disproportionation) poses challenges due to the extreme conditions of temperature and radiation, but studies have shown a dependence on temperature, absorbed dose and salt composition. Through absorption spectroscopy techniques (diffuse reflectance and high-temperature UV-Vis), as well as resonance (Electron Paramagnetic Resonance) it is possible to identify primary transients induced by ionizing radiation trapped in the solid phase (Solid-state radiolysis), and steady-state main absorption components with a fast-acquisition real-time spectroscopy. The presence of heterogeneous phase (colloids), viscosity changes, and gas evolution are among the observed processes. A specific case of study is speciation in the presence of Ni. A corrosion product with magnetic properties due to unpaired electrons in its electronic structure. Ferromagnetic materials are monitored in solidified salts to identify aggregation and phase separation. Comparative studies of eutectic mixtures of LiI-KI and LiCl-KCl with known addition of dopants will be presented, with a perspective of radiation chemistry and its possible implications in complex systems.

36 - MATERIALS SCIENCE↗

Band Bending at CdTe Solar Cell Contacts: Correlating Electro‐Optical and X‐Ray Photoelectron Spectroscopy Analyses of Thin Film Solar Cells

With the semiconductor bulk properties reaching target values for highly efficient solar cells, efforts are applied to reduce losses at solar cell interfaces and contacts. Advances in understanding back contacts in thin‐film polycrystalline CdTe solar cells, a leading thin‐film PV technology, are reported. By using X‐Ray photoelectron spectroscopy, Kelvin probe spectroscopy, time‐ and energy‐resolved photoluminescence, defects at the back contact are analyzed. Densities of recombination centers and charged defects that induce near‐back‐contact band bending, both resulting in recombination losses, were estimated. Electro‐optical and surface analysis results are integrated into a device model, simulating the performance of CdSeTe/CdTe solar cells with 902 mV open circuit voltage.

14 SOLAR ENERGY↗

Photophysics of Intrinsic Single‐Photon Emitters in Silicon Nitride at Low Temperatures

A robust process for fabricating intrinsic single-photon emitters in silicon nitride is recently established. These emitters show promise for quantum applications due to room-temperature operation and monolithic integration with technologically mature silicon nitride photonics platforms. Here, the fundamental photophysical properties of these emitters are probed through measurements of optical transition wavelengths, linewidths, and photon antibunching as a function of temperature from 4.2 to 300 K. Important insight into the potential for lifetime-limited linewidths is provided through measurements of inhomogeneous and temperature-dependent broadening of the zero-phonon lines. At 4.2 K, spectral diffusion is found to be the main broadening mechanism, while spectroscopy time series reveal zero-phonon lines with instrument-limited linewidths.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Instrument of the Imaging X-Ray Polarimetry Explorer

While X-ray spectroscopy, timing, and imaging have improved much since 1962 when the first astronomical nonsolar source was discovered, especially wi the launch of the Newton/X-ray Multi-Mirror Mission, Rossi/X-ray Timing Explorer, and Chandra/Advanced X-ray Astrophysics Facility, the progress of X-ray polarimetry has been meager. This is in part due to the lack of sensitive polarization detectors, which in turn is a result of the fate of approved missions and because celestial X-ray sources appear less polarized than expected. Only one positive measurement has been available until now: the Orbiting Solar Observatory measured the polarization of the Crab Nebula in the 1970s. The advent of microelectronics techniques has allowed for designing a detector based on the photoelectric effect of gas in an energy range where the optics are efficient at focusing in X-rays. Here we describe the instrument, which is the major contribution of the Italian collaboration to the Small Explorer mission called IXPE, the Imaging X-ray Polarimetry Explorer, which will launch in late 2021. The instrument is composed of three detector units based on this technique and a detector service unit. Three mirror modules provided by Marshall Space Flight Center focus X-rays onto the detectors. We show the technological choices, their scientific motivation, and results from the calibration of the instrument. IXPE will perform imaging, timing, and energy-resolved polarimetry in the 2–8 keV energy band opening this window of X-ray astronomy to tens of celestial sources of almost all classes.

79 ASTRONOMY AND ASTROPHYSICS↗

Waveguiding and Dispersion Properties of Interband Cascade Laser Frequency Combs

Mid-infrared semiconductor lasers have emerged as indispensable compact coherent sources for military and commercial applications. While much of the historical emphasis has been on maximizing the output power and/or spectral purity, a recent new focus has been on engineering these lasers to operate as optical frequency combs (OFCs) for broadband real-time spectroscopy. In particular, the combination of low-drive-power and broad gain bandwidth has made interband cascade laser (ICL) OFCs an attractive complement to quantum cascade laser OFCs operating at longer wavelengths. Moreover, ICL combs can potentially be incorporated into fully-integrated dual-comb spectrometers that employ fast, room-temperature IC photodetectors processed on the same chip.However, the high refractive index of the ICL’s GaSb substrate poses some challenges to the optical waveguiding. Because the modal index is considerably lower than that of the substrate, the optical field can penetrate the bottom cladding layer and leak into the GaSb, inducing wavelength-dependent interference that modifies the gain and group velocity dispersion (GVD) profiles. Even when the effect on lasing threshold is small, the comb properties can be adversely affected. Using the sub-threshold Fourier transform technique, we studied ICL combs with various ridge widths, substrate thicknesses, and center wavelengths. This allowed us to evaluate the effects of modal leakage on the GVD. We find that the resonant nature of the substrate modes induces oscillations, which affect both the spectral bandwidth and the phase-locking properties above threshold. Strategies to mitigate the GVD’s undesired and unpredictable spectral variation will be presented.

Meyer, J. R↗

Atomic Force Microscope Active Optical Probe for Single-Molecule Imaging and Time-Resolved Optical Spectroscopy (DOE SBIR Phase II/IIA Final Report)

Actoprobe LLC reports on the results of its DOE SBIR Phase II/IIA project on the development of Atomic Force Microscope Active Optical Probe for Single-Molecule Imaging and Time-Resolved Optical Spectroscopy. While chemistry science and technology greatly benefit from Atomic Force Microscopy in surface characterization, time-resolved chemical imaging on the single-molecule level lags far behind. Current scanning probe microscopy only obtains information about mechanical but not optical/chemical properties. To address this problem, the Actoprobe LLC research team has proposed a novel class of Atomic Force Microscopy probes, Ultra-Fast Pulsed Active Atomic Force Microscopy Optical Probes (UFP AAOPs), that will allow ultrafast time-resolved optical and chemical imaging at the nanoscale. As envisioned, these unique optical probes will perform the functions of conventional Atomic Force Microscopy probes and, in addition, will simultaneously provide chemical information about molecular scale interactions. This innovation is accomplished by integrating an ultrafast pulsed Quantum Dot laser source into an Atomic Force Microscopy probe. This report describes our progress with the fabrication of an ultrafast micrometer-size semiconductor laser, based on “artificial atoms” - Quantum Dots, integrated with an Atomic Force Microscopy probe. In this Phase II/IIA project, we have demonstrated the feasibility of the UFP AAOP concept by fabricating a first prototype of the UFP AAOP. The excellent performance of the probe has been proven in terms of AFM and optical spatial resolution through rigorous tests. The UFP AAOP provides pulses with less than 4 ps duration and higher than 11 GHz repetition rate, and spatial resolution better than 300 nm at 1240 nm wavelength. Technically, it is possible to reduce the pulse width to less than 1 ps and to improve lateral resolution to ~ 0.5 nm, which implies the potential capability for the probe to characterize chemical compounds with single-molecule resolution. The UFP AAOP fabrication procedure has been developed for wafer-scale production of multiple devices, with the yield of the process estimated to be lower than 1% with the limited fabrication capabilities and equipment available for use in the research project. However, using high-volume production tools and special GaAs processing equipment, the yield can be significantly improved, theoretically to ~ 50%. Finally, economic feasibility and scale-up manufacturing potential were analyzed for UFP AAOP and found to be very promising. In summary, the Actoprobe team has successfully demonstrated the feasibility of the UFP AAOP concept.

36 MATERIALS SCIENCE↗

Frame-Transfer Gating Raman Spectroscopy for Time-Resolved Multiscalar Combustion Diagnostics

Accurate experimental measurement of spatially and temporally resolved variations in chemical composition (species concentrations) and temperature in turbulent flames is vital for characterizing the complex phenomena occurring in most practical combustion systems. These diagnostic measurements are called multiscalar because they are capable of acquiring multiple scalar quantities simultaneously. Multiscalar diagnostics also play a critical role in the area of computational code validation. In order to improve the design of combustion devices, computational codes for modeling turbulent combustion are often used to speed up and optimize the development process. The experimental validation of these codes is a critical step in accepting their predictions for engine performance in the absence of cost-prohibitive testing. One of the most critical aspects of setting up a time-resolved stimulated Raman scattering (SRS) diagnostic system is the temporal optical gating scheme. A short optical gate is necessary in order for weak SRS signals to be detected with a good signal- to-noise ratio (SNR) in the presence of strong background optical emissions. This time-synchronized optical gating is a classical problem even to other spectroscopic techniques such as laser-induced fluorescence (LIF) or laser-induced breakdown spectroscopy (LIBS). Traditionally, experimenters have had basically two options for gating: (1) an electronic means of gating using an image intensifier before the charge-coupled-device (CCD), or (2) a mechanical optical shutter (a rotary chopper/mechanical shutter combination). A new diagnostic technology has been developed at the NASA Glenn Research Center that utilizes a frame-transfer CCD sensor, in conjunction with a pulsed laser and multiplex optical fiber collection, to realize time-resolved Raman spectroscopy of turbulent flames that is free from optical background noise (interference). The technology permits not only shorter temporal optical gating (down to <1 s, in principle), but also higher optical throughput, thus resulting in a substantial increase in measurement SNR.

Nguyen, Quang-Viet↗

Chemical bond reorganization in intramolecular proton transfer revealed by ultrafast X-ray photoelectron spectroscopy

Time-resolved X-ray photoelectron spectroscopy (TR-XPS) is used in a simulation study to monitor the excited state intramolecular proton transfer between oxygen and nitrogen atoms in 2-(iminomethyl)phenol. Real-time monitoring of the chemical bond breaking and forming processes is obtained through the time evolution of excited-state chemical shifts. By employing individual atomic probes of the proton donor and acceptor atoms, we predict distinct signals with opposite chemical shifts of the donor and acceptor groups during proton transfer. Details of the ultrafast bond breaking and forming dynamics are revealed by extending the classical electron spectroscopy chemical analysis to real time. Through a comparison with simulated time-resolved photoelectron spectroscopy at the valence level, the distinct advantage of TR-XPS is demonstrated thanks to its atom specificity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identifying neutron sources using recoil and time-of-flight spectroscopy

Identification of neutron sources is central to nuclear physics and its applications, from planetary science to nuclear security, yet direct source discrimination from measured neutron spectra remains fundamentally elusive. Here, we introduce a Bayesian protocol that directly infers source ensembles from measured neutron spectra by combining full-spectrum template matching with probabilistic evidence evaluation. Applying this protocol to recoil and time-of-flight spectroscopy, we recover single- and two-source configurations with strong statistical significance (beyond 4⁢𝜎) at event counts as low as ∼10 3 . These results demonstrate that neutron spectral signatures can be leveraged for robust source identification, opening a new observational window for both fundamental research and operationally driven applications.

neutron physics↗

Time-domain terahertz emission spectroscopy on van der Waals materials

Time-domain terahertz (THz) emission spectroscopy provides a direct method to probe transient photo-currents by recording the emitted terahertz electric field. Although the basic principles of THz surface emission have been understood for more than 30 years, the constant progress in ultrafast laser science to ever shorter pulses, the development of new materials and enhanced sensitivity promote THz emission spectroscopy as a reliable method to gain insights into charge carrier dynamics with unprecedented precision. It provides a versatile tool to study ultrafast processes, such as plasmon-driven hot carriers, dynamics of Dirac fermions, interfacial charge transfer, coherent phonon emission and quantum beating, to name only a few. However, despite the rapidly growing body of research on van der Waals materials, especially in their low-dimensional limit, THz emission spectroscopy has only been applied to a limited extent in these material systems. In this prospective, we review time-domain THz emission spectroscopy as a complementary approach to probe ultrafast charge carrier dynamics and the material’s nonlinear response. After a description of the experimental method, we report on THz emission spectroscopy of bulk and 2D van der Waals materials with special focus on graphene and transition metal dichalcogenide layers.

2D materials↗

Time-resolved X-ray Spectroscopy from the Atomic Orbital Ground State Up

X-ray spectroscopy has been a key method to determine ground and excited state properties of quantum materials with atomic specificity. Now, new x-ray facilities are opening the door to the study of pump-probe x-ray spectroscopy - specifically time-resolved x-ray absorption (trXAS) and time-resolved resonant inelastic x-ray scattering (trRIXS). In this paper we will present simulations of each of these spectroscopies using a time-domain full atomic multiplet, charge transfer Hamiltonian, adapted to study the properties of a generalized cluster model including a central transition metal ion caged by ligand atoms in a planar geometry. The numerically evaluated trXAS and trRIXS cross-sections for representative electron configurations 3d9 and 3d8 demonstrate the insights that can be obtained from charge transfer pumping, and how this nonequilibrium process affects ground and excited state properties. The straightforward characterization of the excitations in these systems, based on our analysis of the simulations, can serve as a benchmark for future experiments, as access to these time-resolved spectroscopic techniques becomes more widely available.

Jost, Daniel↗

Correlative acoustic time-of-flight spectroscopy and X-ray imaging to investigate gas-induced delamination in lithium-ion pouch cells during thermal runaway

It remains difficult to detect internal mechanical deformation and gas-induced degradation in lithium-ion batteries, especially outside specialized diagnostics laboratories. In this work, we demonstrate that electrochemical acoustic time-of-flight (EA-ToF) spectroscopy can be used as an insightful and field-deployable diagnostic/prognostic technique to sense the onset of failure. A 210 mAh commercial lithium-ion cell undergoing thermal abuse testing is probed with in situ and operando EA-ToF spectroscopy, together with simultaneous fractional thermal runaway calorimetry (FTRC) and synchrotron X-ray imaging. The combination of X-ray imaging and EA-ToF analysis provides new understanding into the through-plane mechanical deformation in lithium-ion batteries through direct visualisation and the acoustic ToF response. Internal structural changes, such as gas-induced delamination, are identified using EA-ToF spectroscopy due to variations in the attenuation and signal peak shifts. This is corroborated using X-ray imaging, demonstrating EA-ToF spectroscopy as a promising technique for detecting onset of battery failure.

25 ENERGY STORAGE↗

CubeX: A Compact X-Ray Telescope Enables Both X-Ray Fluorescence Imaging Spectroscopy and Pulsar Timing Based Navigation

This paper describes the benefits of a miniaturized X-ray telescope payload in the context of a lunar mission. The first part describes the payload in detail, the second part summarizes a small satellite mission concept that utilizes its compact form factor and performance. The CubeX instrument can be used for both X-ray fluorescence (XRF) imaging spectroscopy and X-ray pulsar timing based navigation (XNAV). Using our recent technological advances in X-ray optics and sensors, CubeX combines high angular resolution (<1 arcminutes) Miniature Wolter-I X-ray optics (MiXO) with a common focal plane consisting of high spectral resolution (<150 eV at 1 keV) CMOS X-ray sensors and a high timing resolution (< 1 usec) SDD X-ray sensor. This novel combination of the instruments enables both XRF measurements and XNAV operations without moving parts. The high angular resolution of the MiXO opens a wide range of orbital configurations for observation. Given that performance, the instrument has unprecedented small volume (~1×1×6U), mass (<6 kg), and power (<9W) requirements and opens a wide range of applications for a variety of targets and missions including NEOs and Martian moons. In this paper we illustrate one potential application for a lunar mission concept: The elemental composition of the Moon holds keys to understanding the origin and evolution of both the Moon and the Earth. X-ray fluorescence (XRF), induced either by solar X-ray flux or energetic ions, carries decisive signatures of surface elemental composition. X-ray observations, therefore, give a unique, powerful diagnostic tool for remotely determining elemental abundances including major rock forming elements such as Mg, Al, Na, Si, Fe, and Ca. Through high-resolution XRF imaging spectroscopy, CubeX searches for small patches of elusive lower crust and mantle material excavated within and around impact craters. CubeX identifies regional compositional variations and allows straightforward comparison of elemental distributions with the surface topography from LRO and the gravity data from GRAIL. The elemental compositions of the lower crust and the mantle are sensitive to the conditions of the giant impact which led to the Moon's formation and the subsequent lunar magma ocean (LMO), and thus they are key missing pieces in understanding the formation and early evolution of the Moon. In between XRF observations, CubeX also leverages the technology of high resolution X-ray imaging and time series measurements to conduct XNAV operations and evaluate their performance. Deep space navigation is a critical issue for small planetary missions. XNAV can enable low-cost autonomous deep-space navigation, and has the potential to greatly assist, or even outperform, NASA's Deep Space Network (DSN) or ESA's European Space Tracking (ESTRACK). CubeX is designed to perform sequential observations of 3-4 millisecond pulsars (MSPs) to solve the spacecraft trajectory for absolute navigation, and explore the remote sensing capability of XNAV. In the presented mission concept, the Moon's relative proximity enables a straightforward evaluation of the XNAV performance through DSN.

x-ray spectroscopy↗