Search NASA⌕ Search

SEARCH · Search NASA

Results for “Total suspended solids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Topical Report on Water Balance Model Development and Initial Application

This topical report summarizes results from developing a generic dynamic water balance tool which can be used by coal-fired power plant operators to evaluate FGD water management strategies. EPRI is using a statistical software model created on the GoldSim platform and data from coal-fired energy plants to determine the fraction of power plant water needs that can be satisfied by electrodialysis reversal treatment and, correspondingly, the discharge volume and/or byproducts that still need to be managed. The generic model is designed to accept a number of easily obtainable process variables and generate probabilities of resultant water characteristics. The model is also constructed as a universal process flow; one that can be adjusted to accommodate most major components of an FGD blowdown handling system. The generic model is dynamic and utilizes user-inputted operational variation in water quality and quantity to best provide a probabilistic representation of potential performance outcomes. In order to account for complexities of water composition and treatment, a separate chemical modeling software is used to evaluate water chemistry and unit operation performance. The thermodynamic modeling software, OLI Studio, is employed to convert ion data from laboratory analyses into balanced molecular concentrations that are classified as dissolved and suspended solids. The dynamic water model is designed to import a total of 11 species commonly found in FGD blowdown water as molecular concentrations.Water management unit operations are used in the model and categorized by either physical unit operation blocks or chemical unit operations blocks. As the name implies, the physical water treatment blocks are unit operations that are exclusively physical changes to the system (e.g., separations and volume changes). The chemical water treatment blocks are unit operations where chemical changes occur and require the use of OLI Studio to characterize subsequent streams. Water and material balances from three unique coal-fired power plants were obtained and preliminary modeling on the dynamic water balance tool was performed using the extracted data from these power plants. These three power plants were chosen due to their unique configurations and water profiles that represented a variety of operational changes. Results from using the dynamic tool with the three plant configurations are presented and discussed in the context of the existing tool and planned future capabilities.

01 COAL, LIGNITE, AND PEAT↗

Photographic quantification of water quality in mixing zones

The waste effluent mixing zone is defined as the extent of a receiving water body utilized to dilute a waste charge to a concentration characteristic of a totally mixed condition. Color IR photography was used in conjunction with suspended solids water samples to quantitatively delineate the mixing zone resulting from the discharge of a paper mill effluent. Digital scanning microdensitometer data were used to estimate and delineate suspended solids concentrations on the basis of a semiempirical model. Model background, development, and implementation are described. Results indicate that the method is as reliable as conventional surface measuring techniques and is, in fact, more detailed. The method has direct application to the establishment of water quality guidelines, the development of both governmental and private sampling and surveillance programs, and the development of design and location criteria for industrial and municipal waste effluent outfalls.

Lillesand, T. M.↗

Prototype Wash Water Renovation System Integration with Government-Furnished Wash Fixture

A total renovation concept for removing objectionable materials from spacecraft wash water to make the water reusable was developed. This concept included ferric chloride pretreatment to coagulate suspended solids such as soap and lint, pressure filtration, and carbon adsorption and ion exchange to remove trace dissolved organics and inorganic salts. A breadboard model which was developed to demonstrate the design adequacy of the various system components and the limits on system capacities and efficiencies.

Source record↗

Characterization of Infrequent Samples from the Concentration, Storage, and Transfer Facility: F-Area Pump Pit 3 (FPP-3) Sump Sample: December 2021 Sample

In December 2021, SRR-E sent an ~185 mL sample identified as FPP-3 from a F-Area pump pit sump to SRNL for analysis. The sample was pale yellow in color and contained a small amount of suspended solids visually estimated to be less than 1% by volume. SRNL analysis indicated that the sample contained 4.4 E+05 dpm/mL Cs-137, 6.2 E+05 dpm/mL total beta activity, 9.3 E+02 dpm/mL beta activity following cesium removal, and below detectable levels of alpha activity following cesium removal. In addition, the sample contained 0.015 M free OH- and 947 μg total organic carbon/mL.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparative analysis of various pretreatments to mitigate fouling and scaling in membrane distillation

Membrane distillation (MD) has shown strong promise for treating hypersaline produced water (PW) streams. Scaling and fouling on the membrane surface, however, have been identified as major challenges for commercialization and widespread application. The focus of this study was to first identify the nature of foulants and scalants on the membrane surface and then investigate the pretreatment strategies that mitigate the extent of fouling and scaling on the membrane surface. Vacuum MD (VMD) was selected for this study because of its higher flux at more moderate feed temperatures that eventually leads better assessment of fouling and scaling on the membrane surface. VMD flux tests were carried out with three different real PW samples at total dissolved solids concentrations in the range of 120-160 g/L. It was found that an efficient pretreatment prior to MD is required to mitigate the fouling potential of the organic matter, mostly suspended constituents, in PW samples. Suspended organics fouled and quickly wetted the MD membrane. Major conventional treatments, including filtration, oxidation, coagulation, air floatation, and aeration were investigated to pretreat the PW before VMD tests. A comprehensive comparative analysis is presented showing that the ultrafiltration and coagulation pretreatments displayed the best performance in mitigating the fouling and scaling, while oxidative pretreatment was found to be effective in reducing the iron concentration to less than 5 ppm. The surface of scaled membranes was carefully characterized to further evaluate the performance of each pretreatment. The components that had the highest tendency to precipitate on the membrane surface were identified as strontium sulfate, calcium carbonate, sodium chloride, iron oxide, and silica. In closing, these findings are supported by thermodynamic estimation of the saturation index.

42 ENGINEERING↗

Kansas environmental and resource study: A Great Plains model. Monitoring fresh water resources

The author has identified the following significant results. ERTS MSS ratios derived from CCT's are very effective for quantitative detection of suspended solid up to at least 900 ppm. The relatively high inorganic suspended solids, characteristic of midcontinent reservoirs, dominates the reflected energy present in the four MSS bands. Dissolved solids concentrations up to 500 ppm and algal nutrients up to 20 ppm are not detectable. The MSS5/MSS4 ratio may be weakly correlated with total chlorophyll above approximately 8 micrograms/liter.

Yarger, H. L.↗

Phytoxicity study of the products of wet oxidation of a representative biomass (lettuce)

In an attempt to verify the results reported previously concerning the phytotoxicity of wet-oxidation (wet-ox) products, lettuce solids were suspended in water and then heated to 548 K for 3.6 ksec (1 hr) under 4.1x10 to the -7 Pa (400 psig at 294 K) oxygen pressure and 1.52x10 to the 8th (1500 psig at 548 K) total pressure. Such treatment resulted in oxidation of 80% of the initial organic carbon to carbon dioxide. Thirty-three percent of the remaining organic carbon was present in acetic acid. Organic nitrogen in the feed was decreased 90% by the wet-ox treatment. Ammonia and nitrogen gas were the main nitrogen products. Analysis of the liquid product of wet-ox indicated that most of the minerals essential for plant growth were present. However, when tested using a lettuce-root growth-rate assay, the solution was toxic. This toxicity was not due to excessive salt or ammonia or to an improper pH. Analysis of the wet-ox solution revealed the presence of silver and chromium, thus implicating reactor corrosion as the cause of the phytotoxicity. Both cation and anion exchange resins removed the silver and the toxicity of the liquid effluent, indicating silver as the toxic component. Uptake of both silver and chromium by lettuce roots correlated with diminished root growth. Toxicity of the solution from wet-ox was not observed when precautions were taken to minimize contact of the liquid in the reactor with the metal reactor components.

Onisko, B. L.↗

Compiled data on the vascular aquatic plant program, 1975 - 1977

The performance of a single cell, facultative sewage lagoon was significantly improved with the introduction of vascular aquatic plants. Water hyacinth (Eichhornia crassipes) was the dominant plant from April to November; duckweed (Lemna spp.) and (Spirodela spp.) flourished from December to March. This 2 ha lagoon received approximately 475 cu m/day of untreated sewage and has a variable COD sub 5 loading rate of 22-30 kg/ha/day. During the first 14 months of operation with aquatic plants, the average influent BOD sub 5 was reduced by 95% from 110 mg/l to an average of 5 mg/l in the effluent. The average influent suspended solids were reduced by 90% from 97 mg/l to 10 mg/l in the effluent. Significant reductions in nitrogen and phosphorus were effected. The monthly kjeldahl nitrogen for influent and effluent averaged 12.0 and 3.4 mg/l, respectively, a reduction of 72%. The total phosphorus was reduced on an average of 56% from 3.7 mg/l influent to 1.6 mg/l effluent.

Wolverton, B. C.↗

Water Hyacinths for Upgrading Sewage Lagoons to Meet Advanced Wastewater Treatment Standards, Part 1

Water hyacinths, Eichhornia crassipes Mart. Solms, have demonstrated the ability to function as an efficient and inexpensive final filtration system in a secondary domestic sewage lagoon during a three month test period. These plants reduced the suspended solids, biochemical oxygen demanding substances, and other chemical parameters to levels below the standards set by the state pollution control agency. The water hyacinth-covered secondary lagoon utilized in this experiment had a surface area of 0.28 hectare (0.70 acre) with a total capacity of 6.8 million liters (1.5 million gallons), receiving an inflow of 522,100 liters (115,000 gallons) per day from a 1.1 hectare (3.8 acre) aerated primary sewage lagoon. These conditions allowed a retention time of 14 to 21 days depending on the water hyacinth evapotranspiration rates. The desired purity of final sewage effluent can be controlled by the water hyacinth surface area, harvest rate, and the retention time.

Wolverton, B. C.↗

Effects of solid particles suspended in fluid flow through an axial flow compressor stage

An approximate method for calculating the flow properties of gas-particle mixture flowing over blades in a cascade is studied. Using an analytical method, the solid particle trajectory and location of collisions between the solid particles and the blade surfaces are determined. In addition an experimental investigation of the trajectories and velocities of solid particles suspended in a fluid passing through an axial flow compressor cascade was performed. The cascade blades were made of 2024 aluminum alloy and the solid particles used were quartz sand with average diameter of 165 microns. The following parameters were investigated: blade pressure distribution, and total pressure loss coefficient, both depending on the degree of erosion. In addition, a theoretical estimation of the blade erosion is compared with the experimental data.

Tabakoff, W.↗

FeS colloids – formation and mobilization pathways in natural waters

For this study, we have used synchrotron-based X-ray absorption spectroscopy (structure of Fe–S clusters), transmission electron microscopy (solid-phase crystallinity), Fourier-transform ion-cyclotron-resonance mass spectrometry (identity and composition of natural organic carbon compounds), inductively coupled plasma optical emission spectrometry (total aqueous Fe), and the revised ferrozine method (aqueous Fe( II ) and Fe( III ) concentrations) to determine the stability and nature of colloids generated by sulfidation of ferrihydrite nanoparticles in the absence and presence of organic compounds. We observed that reductive dissolution of ferrihydrite by aqueous sulfide generates nm-scale FeS clusters. Their subsequent aggregation, which promotes settling of FeS aggregates into the solid fraction, was directly correlated with sulfide/Fe ratio. At sulfide/Fe ratios ≤0.5, FeS clusters and larger colloids remained in suspension for at least 14 days (and up to several months). At sulfide/Fe ratios >0.5, sulfidation reaction rates were rapid and FeS cluster aggregation was accelerated. Moreover, the presence of organic compounds increased the time of suspension of FeS colloids, whereas increased ionic strength inhibited the generation of FeS colloids. We present a general conceptual model to predict when and where FeS colloids can form and enhance or inhibit the mobility of contaminants and nutrients associated with them. Our study indicates that in lowsalinity fresh groundwater systems poor in sulfate (i.e. low sulfidation; lakes, floodplains, peatlands etc.), the ferrihydrite sulfidation reaction generates aqueous FeS clusters and larger colloids that remain suspended over long time periods, thus mobilizing a substantial fraction of the total aqueous Fe and S.

54 ENVIRONMENTAL SCIENCES↗

In anaerobic reactors the microbial community structure depends on feed type, with no “keystone” species tied to COD removal

Two-stage anaerobic digestion (AD) systems provide treatment for high strength wastewater with high stability and performance. Encapsulation technology can intensify AD to facilitate the separation of the solids retention time from the hydraulic retention time (HRT), offering lower HRTs, smaller reactors, and high effluent quality. To support successful deployment, however, the encapsulated community must contain all the needed microorganisms for successful treatment and be flexible enough to treat a variety of wastewaters. Here, a two-stage system was investigated in which microbial cultures were enriched on various high-strength wastewaters in suspended flow-through systems to determine how feed type influenced performance and microbial community structure. The hypothesis was that specific genera, or so-called “keystone species” would positively correlate to organic carbon degradation for a given feed, enabling construction of a well-functioning community for encapsulation. Results showed that the number of total bacteria (as 16S rRNA gene copies) did not correlate to soluble chemical oxygen demand (sCOD) removal, indicating that the community structure and/or members were important for good performance. Results also showed that feed type strongly influenced carbon removal and microbial community structure for 1st-stage fermenting communities, but not 2nd-stage methanogenic communities. In this study, the “core” community members were defined as organisms common to all of either the 1st- or 2nd-stage reactors irrespective of the feed they received and were present in at least 50% of the samples throughout the entire experiment. “Unique” community members were specific to a single feed, and hence, only present in either the 1st- or 2nd-stage reactors receiving that feed. In both 1st- and 2nd-stage communities, only one core genera and no unique genera were positively and significantly correlated to sCOD removal. Verification experiments performed with encapsulated communities showed that organisms identified in flow-through system and correlated with carbon degradation, though not significantly, seemed to be important for performance. Our results suggest that one cannot construct a community containing specific populations in lieu of enrichment. Nevertheless, a single diverse encapsulated anaerobic community should provide good (>80%) carbon removal when fed a variety of influents, if time is provided for enrichment after deployment.

54 ENVIRONMENTAL SCIENCES↗

Tank 27 Solids Disturbance Testing Using M-Star for the Impact of CSMP Usage on Blend Tank Mixing Effectiveness

Savannah River Mission Completion (SRMC) plans to operate Tank 27as a blend tank for future waste disposal operations. It is desirable to avoid additional worker exposure by using the planned commercial submersible mixing pump (CSMP) installations in Risers B2 and B4 to function as the blend pumps for prolonged blend tank operations. The purpose of this task is to evaluate the impacts to mixing across a range of pump installation heights from 1 to 201 inches above the tank floor. The CSMPs shall maintain adequate blending within a 24 hour maximum timeframe and an adequate nozzle discharge velocity as outlined in U-ESR-G-00030, using the specifications of the planned CSMPs listed in PO SRRA149971 and M-DS-G-00081. Specifications include: maximum pump diameter of D=22.5 in., dual nozzles placed tangentially opposed with nominal inside diameter of 2 in., total flow range (both nozzles combined) of 500 to 1950 GPM and maximum RPM of 1800. Tank 27 is expected to have a fill height maximum of 360". This analysis began by using results from the 2010 testing and applying them to the Tank 27 design to calculate a mixing time as a function of pump flow rate. These results were modified to account for the higher liquid level in Tank 27. Once the liquid level was increased to 360 inches, the results were modified to account for a higher viscosity in Tank 27 than in the testing. Once the viscosity was increased, the effect of changing pump elevation was applied to calculations of the mixing time in Tank 27. Finally, the uncertainty from the testing was included in the analysis to recommend a blend time as a function of pump flow rate and elevation. The conclusion from this study is that the particles in tank 27 will be suspended at both the 600 and 900 gpm flow rates. Only particles above 90 micron will not be suspended in significant amounts when the flow rate is 600 gpm. At 900 gpm even 100 micron particles were thoroughly suspended in the tank. From the series of simulations it has been concluded that it will not be possible to mix tank 27 at the proposed fluid flow rates and not suspend the solid particles at the bottom of the tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Environmental solid particle effects on compressor cascade performance

The effect of suspended solid particles on the performance of the compressor cascade was investigated experimentally in a specially built cascade tunnel, using quartz sand particles. The cascades were made of NACA 65(10)10 airfoils. Three cascades were tested, one accelerating cascade and two diffusing cascades. The theoretical analysis assumes inviscid and incompressible two dimensional flow. The momentum exchange between the fluid and the particle is accounted for by the interphase force terms in the fluid momentum equation. The modified fluid phase momentum equations and the continuity equation are reduced to the conventional stream function vorticity formulation. The method treats the fluid phase in the Eulerian system and the particle phase in Lagrangian system. The experimental results indicate a small increase in the blade surface static pressures, while the theoretical results indicate a small decrease. The theoretical analysis, also predicts the loss in total pressure associated with the particulate flow through the cascade.

Tabakoff, W.↗

Effect of particle presence on the incompressible inviscid flow through a two dimensional compressor cascade

A computational model is developed for calculating the flow field, in the presence of solid particles, through a two-dimensional compressor cascade. Results show that the effect of solid particles on the flow field contributes to the bending of the streamlines toward the blade suction surface. It is determined that the difference in the pressure coefficient for particulate flow, with 165 micron diameter for the particles, is of the order of 3 percent over the air only flow. The change in the pressure coefficients is shown to be much larger for very small particles. It was found that the total pressure loss associated with the particulate flow is very high for very small particles as compared with large particles. The total pressure loss is also shown to be higher for accelerating flow than for decelerating flow. The total pressure loss is shown to be directly proportional to the particle concentration. It is concluded that significant reductions in performance can occur in a real multistage machine due to the changes in the pressure ratios, particularly if the suspended matter is small particles.

Balan, C.↗

Impacts of Water Clarity Variability on Temperature and Biogeochemistry in the Chesapeake Bay

Estuarine water clarity depends on the concentrations of aquatic constituents, such as colored dissolved organic matter, phytoplankton, inorganic suspended solids, and detritus, which are influenced by variations in riverine inputs. These constituents directly affect temperature because when water is opaque, sunlight heats a shallower layer of the water compared to when it is clear. Despite the importance of accurately predicting temperature variability, many numerical modeling studies do not adequately account for this key process. In this study, we quantify the effect of water clarity on heating by comparing two simulations of a hydrodynamic-biogeochemical model of the Chesapeake Bay for the years 2001–2005, in which (1) water clarity is constant in space and time for the computation of solar heating, compared to (2) a simulation where water clarity varies with modeled concentrations of light-attenuating materials. In the variable water clarity simulation, the water is more opaque, particularly in the northern region of the Bay. This decrease in water clarity reduces the total heat, phytoplankton, and nitrate throughout the Bay. During the spring and summer months, surface temperatures in the northern Bay are warmer by 0.1 °C and bottom temperatures are colder by 0.2 °C in the variable light attenuation simulation. Warmer surface temperatures encourage phytoplankton growth and nutrient uptake near the head of the Bay, and fewer nutrients are transported downstream. These impacts are greater during higher river flow years, when differences in temperature, nutrients, phytoplankton, and zooplankton extend further seaward compared to other years. This study demonstrates the consequences of utilizing different light calculations for estuarine heating and biogeochemistry.

water clarity↗

Design of High Resolution Soft X-Ray Microcalorimeters Using Magnetic Penetration Thermometers

We have designed high-resolution soft x-ray microcalorimeters using magnetic penetration thermometers (MPTs) in an array of pixels covering a total of 2 square centimeters to have a resolving power of 300 at energies around 300 eV. This performance is desirable for studying the soft x-ray background from the warm hot intergalactic medium. MPT devices have small sensor heat capacity and high responsivities, which makes them excellent detector technology for attempting to attain sub-eV resolution. We are investigating the feasibility of pixels with absorbers that are 625 x 625 square micrometers, up to 1 x 1 square millimeters in area and 0.35 micrometer thick and thinner. Our tests have shown that suspended gold absorbers 0.35 micrometers thick (RRR = 6.7) are feasible to fabricate. We modeled the thermal diffusion from such thin gold over the size of a 625 x 625 square micrometer absorber, and conclude that the effect of the thermalization on the resolution of a 300 eV photon is an additional approximately 0.2 eV FWHM of broadening. We discuss the thermal effects of small absorber attachment sterns on solid substrate, as well as considerations for multiplexed readout. We will present the progress we have made towards building and testing this soft x-ray detector.

Busch. Sarah↗

Produced Water and Waste Heat-aided Blowdown Water Treatment: Using Chemical and Energy Synergisms for Value Creation

The project objective was to develop a cooling blowdown water (BDW) treatment process utilizing produced water (PW) and low-grade heat to maximize water reuse and saleable by-product generation while reducing chemical and energy footprints of the treatment. The proposed treatment process consists of mixing, softening, organics and suspended solids removal, reverse osmosis (RO), thermal desalination, and brine electrolysis. BDW samples collected from a local coal-fired power plant and PW samples from two shale gas production wells were used in this study. Each treatment unit was first designed and tested to quantify its treatment efficiency, and its chemical and energy requirements. In addition, a process model was developed and model simulations were conducted based on the experimental results and literature data to optimize the treatment process. A techno-economic analysis was conducted to quantify chemical and energy savings as well as production of 10-lb brine as a saleable product. With the field-collected BDW and PW samples, mixing experiments determined a volumetric mixing ratio 10:1 (BDW:PW) resulted in the best performance of multivalent ions removal and largest chemical savings for softening. Softening of the BDW/PW mixtures using alkaline chemicals (Na 2 CO 3 and NaOH) achieved 95%-100% removal of scaling-forming cations (Ca, Mg, Fe, Ba, Sr) and 60% of silicon, and 10% of total organic carbon (TOC). The mixing and softening treatments yielded an effluent with total dissolved solids (TDS) concentration of 23 g/L. Activated carbon (AC) filtration removed TOC to a low level (< 3 mg/L) and further removed remaining scale-forming divalent metals and silica from the softened water. The AC filtration resulted in a slight reduction of TDS from 23 g/L to 20 g/L, leaving behind only mostly monovalent ions (i.e., sodium and chloride) in the filtered water. These pretreatments yielded a feed water that met the criteria of the downstream reverse osmosis (RO) to prevent membrane fouling. A cross-flow RO system was used to further concentrate the TDS of the AC effluent. Various factors including TDS, pH, and applied pressure were examined and optimal conditions were determined for the co-treatment process. An integrated process consisting of mixing, softening, AC filtration and RO was used to treat a continuous flow (0.25 – 1.2 L/min, or 0.07 – 0.32 gpm) and successfully generated RO permeate as product water (TDS < 0.5 g/L) for reuse in cooling operation, and a concentrate (TDS ~ 45 g/L) to be further treated in a thermal desalination unit. These flow rates meet the FOA’s criterion of 0.01 – 1 gpm. Overall, the co-treatment of BDW/PW allowed shorter ramp-up time compared to treatment of BDW alone. It resulted in 40% and 55% savings of Na 2 CO 3(s) and NaOH, respectively, compared to treating the BDW and PW individually for the same level of softening. The co-treatment also resulted in a 29% energy saving compared to treatment of BDW only for the level of TDS concentration. A thermal desalination system was designed using CFD simulations and manufactured in the WVU Innovation Hub for further treatment of the RO concentrate to generate 10-lb brine. The system has a design flow rate of 2 gpm and has been successfully tested. A bench-scale brine electrolysis system was developed for on-site generation of chlorine/hypochlorite (Cl 2 /OCl - ) and caustic soda (NaOH) as useful chemicals for the co-treatment process. Using salt solutions (0.5 M and 1 M), the system achieved faradaic efficiencies of 93%-97% and 70%-77% for caustic soda and chlorine/hypochlorite generation, respectively. An economic analysis showed that the electricity costs for on-site generation of these chemicals were significantly lower than the chemical prices offered by suppliers. An industrial-scale process model consisting of mixing, softening, AC filtration, RO, thermal desalination, and brine electrolysis was developed using the Aspen Plus V9 in conjunction with Aspen Custom Modeler V9. The model serves as a solvable Aspen Plus model and as basis to form the costing infrastructure. In addition, techno-economic analysis considering capital, operating, and transportation costs was conducted. An optimization solution showed that produced water for mixing is still advantageous in low quantities. The optimum solution approaches a leveled cost of water (LCW) of 2 $/m 3 which becomes cost competitive with nominal water treatment prices.

20 FOSSIL-FUELED POWER PLANTS↗