Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tracking error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Effects of Control Stick Parameters on Human Controller Response

A fixed base laboratory tracking study was conducted to determine the effects of stick displacement and stick force characteristics on human tracking performance. Three different levels of control stick force/displacement characteristics and stick electrical gain were varied to observe their influence on RMS (Root Mean Square) tracking error and RMS control activity (stick output). The results indicated that both RMS tracking error and RMS control activity were influenced by the three different levels of control stick force/displacement characteristics and stick electrical gain. The human neuromotor time constant was affected by the electrical control gain of the stick while the spring stiffness of the stick influenced the time delay characteristics of the human response behavior.

Repperger, D. W.↗

UWB Tracking System Design for Lunar/Mars Exploration

This paper describes a design effort for a prototype ultra-wideband (UWB) tracking system that is currently under development at NASA Johnson Space Center (JSC). The system is being studied for use in tracking of lunar/Mars rovers during early exploration missions when satellite navigation systems are not available. The UWB technology is exploited to implement the tracking system due to its properties such as high data rate, fine time resolution, low power spectral density, and multipath immunity. A two-cluster prototype design using commercially available UWB products is proposed to implement the Angle Of Arrival (AOA) tracking methodology in this research effort. An AOA technique using the Time Difference Of Arrival (TDOA) information is utilized for location estimation in the prototype system, not only to exploit the precise time resolution possible with UWB signals, but also to eliminate the need for synchronization between the transmitter and the receiver. After the UWB radio at each cluster is used to obtain the TDOA estimates from the UWB signal sent from the target, the TDOA data is converted to AOA data to find the angle of arrival, assuming this is a far field application. Since the distance between two clusters is known, the target position is computed by a simple triangulation. Simulations show that the average tracking error at a range of 610 meters is 2.7595 meters, less than 0.5% of the tracking range. Outdoor tests to track the SCOUT vehicle (The Science Crew Operations and Utility Testbed) near the Meteor Crater, Flagstaff, Arizona were performed on September 12-13, 2005. The tracking performance was obtained with less than 1% tracking error at ranges up to 2000 feet. No RF interference with on-board GPS, video, voice and telemetry systems was detected. Outdoor tests demonstrated the UWB tracking capability.

Ni, Jianjun↗

Congruent and spurious motion in the learning and performance of a compensatory tracking task.

Examination of the importance of congruent and spurious yaw motion in compensatory tracking by eight airline pilots. The pilots, seated erect in the Ames man-carrying rotation device(MCRD), tracked with k/s+1 and k/s(s+1) vehicle dynamics in fixed- and moving-base simulation. Following the learning phase of the experiment, five levels of spurious angular acceleration were superimposed on the motion of the MCRD. Learning of the tracking task was found to be a function of both vehicle dynamics and mode of simulation. The presence of congruent motion information reduced learningtime in k/s(s+1) vehicle dynamics and resulted in lower tracking error in both vehicle dynamics. The spurious angular accelerations resulted in an increase in pilot tracking error; however, the relationship between the magnitude of the acceleration and its effect was highly complex. The data suggest that the minimal disturbance level for spurious angular accelerations during tracking is below 0.4 degec.

Guercio, J. G.↗

Beam’s-eye-view imaging during non-coplanar lung SBRT

Purpose: Beam’s-eye-view (BEV) imaging with an electronic portal imaging device (EPID) can be performed during lung stereotactic body radiation therapy (SBRT) to monitor the tumor location in real-time. Image quality for each patient and treatment field depends on several factors including the patient anatomy and the gantry and couch angles. The authors investigated the angular dependence of automatic tumor localization during non-coplanar lung SBRT delivery. Methods: All images were acquired at a frame rate of 12 Hz with an amorphous silicon EPID. A previously validated markerless lung tumor localization algorithm was employed with manual localization as the reference. From ten SBRT patients, 12 987 image frames of 123 image sequences acquired at 48 different gantry–couch rotations were analyzed. δ was defined by the position difference of the automatic and manual localization. Results: Regardless of the couch angle, the best tracking performance was found in image sequences with a gantry angle within 20° of 250° (δ = 1.40 mm). Image sequences acquired with gantry angles of 150°, 210°, and 350° also led to good tracking performances with δ = 1.77–2.00 mm. Overall, the couch angle was not correlated with the tracking results. Among all the gantry–couch combinations, image sequences acquired at (θ = 30°, ϕ = 330°), (θ = 210°, ϕ = 10°), and (θ = 250°, ϕ = 30°) led to the best tracking results with δ = 1.19–1.82 mm. The worst performing combinations were (θ = 90° and 230°, ϕ = 10°) and (θ = 270°, ϕ = 30°) with δ > 3.5 mm. However, 35% (17/48) of the gantry–couch rotations demonstrated substantial variability in tracking performances between patients. For example, the field angle (θ = 70°, ϕ = 10°) was acquired for five patients. While the tracking errors were ≤1.98 mm for three patients, poor performance was found for the other two patients with δ ≥ 2.18 mm, leading to average tracking error of 2.70 mm. Only one image sequence was acquired for all other gantry–couch rotations (δ = 1.18–10.29 mm). Conclusions: Non-coplanar beams with gantry–couch rotation of (θ = 30°, ϕ = 330°), (θ = 210°, ϕ = 10°), and (θ = 250°, ϕ = 30°) have the highest accuracy for BEV lung tumor localization. Additionally, gantry angles of 150°, 210°, 250°, and 350° also offer good tracking performance. The beam geometries (θ = 90° and 230°, ϕ = 10°) and (θ = 270°, ϕ = 30°) are associated with substantial automatic localization errors. Overall, lung tumor visibility and tracking performance were patient dependent for a substantial number of the gantry–couch angle combinations studied.

60 APPLIED LIFE SCIENCES↗

The Effects of Longitudinal Control-System Dynamics on Pilot Opinion and Response Characteristics as Determined from Flight Tests and from Ground Simulator Studies

The results of a fixed-base simulator study of the effects of variable longitudinal control-system dynamics on pilot opinion are presented and compared with flight-test data. The control-system variables considered in this investigation included stick force per g, time constant, and dead-band, or stabilizer breakout force. In general, the fairly good correlation between flight and simulator results for two pilots demonstrates the validity of fixed-base simulator studies which are designed to complement and supplement flight studies and serve as a guide in control-system preliminary design. However, in the investigation of certain problem areas (e.g., sensitive control-system configurations associated with pilot- induced oscillations in flight), fixed-base simulator results did not predict the occurrence of an instability, although the pilots noted the system was extremely sensitive and unsatisfactory. If it is desired to predict pilot-induced-oscillation tendencies, tests in moving-base simulators may be required. It was found possible to represent the human pilot by a linear pilot analog for the tracking task assumed in the present study. The criterion used to adjust the pilot analog was the root-mean-square tracking error of one of the human pilots on the fixed-base simulator. Matching the tracking error of the pilot analog to that of the human pilot gave an approximation to the variation of human-pilot behavior over a range of control-system dynamics. Results of the pilot-analog study indicated that both for optimized control-system dynamics (for poor airplane dynamics) and for a region of good airplane dynamics, the pilot response characteristics are approximately the same.

Sadoff, Melvin↗

Solar concentration properties of flat fresnel lenses with large F-numbers

The solar concentration performances of flat, line-focusing sun-tracking Fresnel lenses with selected f-numbers between 0.9 and 2.0 were analyzed. Lens transmittance was found to have a weak dependence on f-number, with a 2% increase occuring as the f-number is increased from 0.9 to 2.0. The geometric concentration ratio for perfectly tracking lenses peaked for an f-number near 1.35. Intensity profiles were more uniform over the image extent for large f-number lenses when compared to the f/0.9 lens results. Substantial decreases in geometri concentration ratios were observed for transverse tracking errors equal to or below 1 degree for all f-number lenses. With respect to tracking errors, the solar performance is optimum for f-numbers between 1.25 and 1.5.

Cosby, R. M.↗

Space telemetry degradation due to Manchester data asymmetry induced carrier tracking phase error

The deleterious effects that the Manchester (or Bi-phi) data asymmetry has on the performance of phase-modulated residual carrier communication systems are analyzed. Expressions for the power spectral density of an asymmetric Manchester data stream, the interference-to-carrier signal power ratio (I/C), and the error probability performance are derived. Since data asymmetry can cause undesired spectral components at the carrier frequency, the I/C ratio is given as a function of both the data asymmetry and the telemetry modulation index. Also presented are the data asymmetry and asymmetry-induced carrier tracking loop and the system bit-error rate to various parameters of the models.

Nguyen, Tien M.↗

MRAC with Time-Varying Reference Model from Convex Combination

An extension of model reference adaptive control is presented that accommodates use of a time-varying reference model. Specifically, the reference model is taken to be a time-varying convex combination of two linear, time-invariant models. The design is intended to act as a way to smoothly transition between two different reference models without resorting to a scheduled switch. It also provides the ability to use an interpolated reference model when the plant is operating between design points. The time variation of the combination must satisfy some requirements to ensure stability but is otherwise user choice. Subject to these requirements, bounded tracking error behavior is demonstrated via Lyapunov stability analysis for the single-input, single-output, output feedback case. Tracking error convergence is asymptotic when time variation ceases. The proposed design is demonstrated in simulation of a numerical model.

Hashemi, Kelley E.↗

TH-AB-202-05: BEST IN PHYSICS (JOINT IMAGING-THERAPY): First Online Ultrasound-Guided MLC Tracking for Real-Time Motion Compensation in Radiotherapy

Purpose: While MLC tracking has been successfully used for motion compensation of moving targets, current real-time target localization methods rely on correlation models with x-ray imaging or implanted electromagnetic transponders rather than direct target visualization. In contrast, ultrasound imaging yields volumetric data in real-time (4D) without ionizing radiation. We report the first results of online 4D ultrasound-guided MLC tracking in a phantom. Methods: A real-time tracking framework was installed on a 4D ultrasound station (Vivid7 dimension, GE) and used to detect a 2mm spherical lead marker inside a water tank. The volumetric frame rate was 21.3Hz (47ms). The marker was rigidly attached to a motion stage programmed to reproduce nine tumor trajectories (five prostate, four lung). The 3D marker position from ultrasound was used for real-time MLC aperture adaption. The tracking system latency was measured and compensated by prediction for lung trajectories. To measure geometric accuracy, anterior and lateral conformal fields with 10cm circular aperture were delivered for each trajectory. The tracking error was measured as the difference between marker position and MLC aperture in continuous portal imaging. For dosimetric evaluation, 358° VMAT fields were delivered to a biplanar diode array dosimeter using the same trajectories. Dose measurements with and without MLC tracking were compared to a static reference dose using a 3%/3 mm γ-test. Results: The tracking system latency was 170ms. The mean root-mean-square tracking error was 1.01mm (0.75mm prostate, 1.33mm lung). Tracking reduced the mean γ-failure rate from 13.9% to 4.6% for prostate and from 21.8% to 0.6% for lung with high-modulation VMAT plans and from 5% (prostate) and 18% (lung) to 0% with low modulation. Conclusion: Real-time ultrasound tracking was successfully integrated with MLC tracking for the first time and showed similar accuracy and latency as other methods while holding the potential to measure target motion non-invasively. SI was supported by the Graduate School for Computing in Medicine and Life Science, German Excellence Initiative [grant DFG GSC 235/1].

60 APPLIED LIFE SCIENCES↗

Progression-regression effects in tracking repeated patterns

Subjects used a position control system to perform compensatory tracking of a repeated input pattern. The input pattern was 20 seconds in duration and was either an arctangent function or the sum of two sine waves. Tracking error decreased with practice and increased with the addition of a concurrent memory task. The shape of the ensemble-average tracking error resembled the shape of the input velocity signal throughout these changes in performance. Regression analyses were used to parameterize these effects and compare these results with the predictions of several conceptualizations of perceptual-motor learning.

Jagacinski, R. J.↗

Resource Balancing Control Allocation

Next generation aircraft with a large number of actuators will require advanced control allocation methods to compute the actuator commands needed to follow desired trajectories while respecting system constraints. Previously, algorithms were proposed to minimize the l1 or l2 norms of the tracking error and of the control effort. The paper discusses the alternative choice of using the l1 norm for minimization of the tracking error and a normalized l(infinity) norm, or sup norm, for minimization of the control effort. The algorithm computes the norm of the actuator deflections scaled by the actuator limits. Minimization of the control effort then translates into the minimization of the maximum actuator deflection as a percentage of its range of motion. The paper shows how the problem can be solved effectively by converting it into a linear program and solving it using a simplex algorithm. Properties of the algorithm are investigated through examples. In particular, the min-max criterion results in a type of resource balancing, where the resources are the control surfaces and the algorithm balances these resources to achieve the desired command. A study of the sensitivity of the algorithms to the data is presented, which shows that the normalized l(infinity) algorithm has the lowest sensitivity, although high sensitivities are observed whenever the limits of performance are reached.

Frost, Susan A.↗

Evaluation of tactual displays for flight control

Manual tracking experiments were conducted to determine the suitability of tactual displays for presenting flight-control information in multitask situations. Although tracking error scores are considerably greater than scores obtained with a continuous visual display, preliminary results indicate that inter-task interference effects are substantially less with the tactual display in situations that impose high visual scanning workloads. The single-task performance degradation found with the tactual display appears to be a result of the coding scheme rather than the use of the tactual sensory mode per se. Analysis with the state-variable pilot/vehicle model shows that reliable predictions of tracking errors can be obtained for wide-band tracking systems once the pilot-related model parameters have been adjusted to reflect the pilot-display interaction.

Levison, W. H.↗

Applications of inertial-sensor high-inheritance instruments to DSN precision antenna pointing

Laboratory test results of the initialization and tracking performance of an existing inertial-sensor-based instrument are given. The instrument, although not primarily designed for precision antenna pointing applications, demonstrated an on-average 10-hour tracking error of several millidegrees. The system-level instrument performance is shown by analysis to be sensor limited. Simulated instrument improvements show a tracking error of less than 1 mdeg, which would provide acceptable performance, i.e., low pointing loss, for the Deep Space Network 70-m antenna subnetwork, operating at Ka-band (1-cm wavelength).

Goddard, R. E.↗

Iterative Learning Control for High-Speed Rosette Trajectory Tracking

We demonstrate high-speed tracking of a selfrepeating non-raster scan AFM pattern known as rosette. To generate this pattern, the lateral axes of the scanner trace a sum of two sinusoids with different frequencies but identical amplitudes. A feedback controller is combined with an iterative learning controller (ILC) to track this repetitive pattern. The feedback controller is designed based on the internal model principle and incorporates the fundamental reference frequencies. The ILC eliminates the repeating deterministic disturbances that appear in the tracking error. To verify the efficacy of the control approach, an experiment is conducted using a two degrees-of-freedom microelectromechanical system nanopositioner to track a rosette pattern sequentially at the rate= of five frames per second. The experimental results show that the root-mean-square value of tracking error has been reduced by more than 50% owing to the ILC

42 ENGINEERING↗

Short-term solar pressure effect and GM uncertainty on TDRS orbital accuracy: A study of the interaction of modeling error with tracking and orbit determination

The TDRS was modeled as a combination of a sun-pointing solar panel and earth-pointing plate. Based on this model, explanations are given for the following orbit determination error characteristics: inherent limits in orbital accuracy, the variation of solar pressure induced orbital error with time of the day of epoch, the insensitivity of range-rate orbits to GM error, and optimum bilateration baseline.

Fang, B. T.↗

Rotational wind indicator enhances control of rotated displays

Rotation by 108 deg of the spatial mapping between a visual display and a manual input device produces large spatial errors in a discrete aiming task. These errors are not easily corrected by voluntary mental effort, but the central nervous system does adapt gradually to the new mapping. Bernotat (1970) showed that adding true hand position to a 90 deg rotated display improved performance of a compensatory tracking task, but tracking error rose again upon removal of the explicit cue. This suggests that the explicit error signal did not induce changes in the neural mapping, but rather allowed the operator to reduce tracking error using a higher mental strategy. In this report, we describe an explicit visual display enhancement applied to a 108 deg rotated discrete aiming task. A 'wind indicator' corresponding to the effect of the mapping rotation is displayed on the operator-controlled cursor. The human operator is instructed to oppose the virtual force represented by the indicator, as one would do if flying an airplane in a crosswind. This enhancement reduces spatial aiming error in the first 10 minutes of practice by an average of 70 percent when compared to a no enhancement control condition. Moreover, it produces adaptation aftereffect, which is evidence of learning by neural adaptation rather than by mental strategy. Finally, aiming error does not rise upon removal of the explicit cue.

Cunningham, H. A.↗

Accommodating Sensor Bias in MRAC for State Tracking

The problem of accommodating unknown sensor bias is considered in a direct model reference adaptive control (MRAC) setting for state tracking using state feedback. Sensor faults can occur during operation, and if the biased state measurements are directly used with a standard MRAC control law, neither closed-loop signal boundedness, nor asymptotic tracking can be guaranteed and the resulting tracking errors may be unbounded or unacceptably large. A modified MRAC law is proposed, which combines a bias estimator with control gain adaptation, and it is shown that signal boundedness can be accomplished, although the tracking error may not go to zero. Further, for the case wherein an asymptotically stable sensor bias estimator is available, an MRAC control law is proposed to accomplish asymptotic tracking and signal boundedness. Such a sensor bias estimator can be designed if additional sensor measurements are available, as illustrated for the case wherein bias is present in the rate gyro and airspeed measurements. Numerical example results are presented to illustrate each of the schemes.

Patre, Parag↗

Human operator dynamics for aural compensatory tracking

The human operator's ability to control using aural information only and using combined aural and visual displays was investigated for a simple tracking task. Tracking error was presented to the test subjects using one- and two-ear displays. For both displays the pitch of the tone represented the magnitude of the tracking error. The operator's aural control characteristics were modeled as a describing function plus a remnant. The effects on the measured describing function and remnant of different system dynamics, changes in the frequency content of the input and different displays were determined during the study. The describing function and remnant data indicate that humans can control as well with aural cues as with visual cues for the task considered. However, the reduction in operator time delays, expected because of the generally faster human response to aural stimuli, was not evident in the results. It was also determined that the operators could control equally well with either the one- or two-ear display.

Vinje, E. W.↗