Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transmission electron microscope (TEM)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Universal liquid sample device and process for high resolution transmission electron microscope imaging and multimodal analyses of liquid sample materials

Liquid sample imaging devices and processes are disclosed for high resolution TEM imaging and multimodal analyses of liquid sample materials in situ under high vacuum that are compatible with standard type TEM chip membranes and TEM sample holders allowing TEM liquid sample imaging to be performed wherever a TEM instrument is accessible and at a substantially reduced cost compared to prior art systems and approaches.

36 MATERIALS SCIENCE↗

Revealing Phase Heterogeneity in Vertically Aligned Nanocomposites via Plan-View Electron Energy Loss Spectroscopy

Hydrogen utilization in clean energy technologies is challenged by limited storage and transport within materials, owing to the complex hydrogen kinetics at interfaces [1]. Understanding these interfacial mechanisms at the nanoscale is crucial for developing improved materials for hydrogen applications, particularly proton-conducting fuel cells (PCFCs). Vertically aligned nanocomposites (VANs) grown by pulsed laser deposition (PLD) offer a unique platform for investigating the interfacial effects on hydrogen transport due to their well-defined interfaces parallel to the direction of charge transport [2-4]. To investigate hydrogen transport, the two phases within the VANs were chosen as BaZr 0.9 Y 0.1 O 3-x (BZY), a known proton conductor, and Pr 0.1 Ce 0.9 O 2-x (PCO), a mixed ionic-electronic conductor [5]. This PCO-BZY VANs architecture allows the investigation of how the interface between a proton conductor and a mixed conductor influences hydrogen transport. However, because of the small size of hydrogen, it is difficult to discern the nature of its interactions with interfaces from bulk measurements at the macroscale, thus necessitating nanoscale measurements [6]. Electron energy loss spectroscopy (EELS) allows for nanometer-resolution probing of the local atomic structure and chemistry at the BZY/PCO interface. In this study, plan-view analysis of PCO-BZY VANs films was employed to characterize the structure and phase distribution of the VANs and investigate the interface between the nanostructures. The films were imaged using scanning electron microscopy (SEM) in the Hitachi S-4800 SEM, collecting secondary electron images using mixed upper and lower detectors. Then, plan-view transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM) EELS were employed using a JEOL ARM300 microscope operated at 300kV with a Gatan K3 GIF Continuum detector to study the distribution of the BZY and PCO phases through the film. As a result, spectrum images were acquired at a dispersion of 0.18eV per channel and denoised afterward by principal component analysis (PCA) method.

Griffin, Elizabeth [Northwestern University, Evans↗

Grain growth of nanocrystalline aluminum under tensile deformation: A combined in situ TEM and atomistic study

Nanocrystalline Al thin films have been strained in situ in a transmission electron microscope using two separate nanomechanical techniques involving a push-to-pull device and a microelectromechanical system (MEMS) device. Deformation-induced grain growth was observed to occur via stress-assisted grain boundary migration with extensive grain growth occurring in the necked region, indicating that the increase in local stress drives the boundary migration. Under applied tensile stresses close to the ultimate tensile strength of 450 MPa for a nanocrystalline Al specimen, measured boundary migration speeds are 0.2 – 0.7 nm s -1 for grains outside necked region and increases to 2.5 nm s -1 for grains within the necked region where the local estimated tensile stresses are elevated to around 630 MPa. By tracking grain boundary motion over time, molecular dynamics simulations showed qualitative agreement in terms of pronounced grain boundary migration with the experimental observations. The combined in situ observation and molecular dynamics simulation results underscore the important role of stress-driven grain growth in plastically deforming nanocrystalline metals, leading to intergranular fracture through predominant grain boundary sliding in regions with large localized deformation.

36 MATERIALS SCIENCE↗

In situ electron microscopy: atomic-scale dynamics of metal oxidation and corrosion

Corrosion degrades metals through complex microscopic processes that traditional methods often fail to capture. In-situ transmission electron microscopy (TEM) bridges this gap by providing real-time atomic-scale imaging of oxidation and corrosion dynamics. Gas-phase TEM uncovers critical oxidation mechanisms like oxide nucleation and alloying effects, while liquid-phase TEM tracks corrosion initiation. Coupled with emerging techniques like ultrafast direct electron detection cameras, these advancements promise unprecedented resolution in understanding material degradation.

36 MATERIALS SCIENCE↗

Machine learning for automated experimentation in scanning transmission electron microscopy

Abstract Machine learning (ML) has become critical for post-acquisition data analysis in (scanning) transmission electron microscopy, (S)TEM, imaging and spectroscopy. An emerging trend is the transition to real-time analysis and closed-loop microscope operation. The effective use of ML in electron microscopy now requires the development of strategies for microscopy-centric experiment workflow design and optimization. Here, we discuss the associated challenges with the transition to active ML, including sequential data analysis and out-of-distribution drift effects, the requirements for edge operation, local and cloud data storage, and theory in the loop operations. Specifically, we discuss the relative contributions of human scientists and ML agents in the ideation, orchestration, and execution of experimental workflows, as well as the need to develop universal hyper languages that can apply across multiple platforms. These considerations will collectively inform the operationalization of ML in next-generation experimentation.

36 MATERIALS SCIENCE↗

Stroboscopic ultrafast imaging using RF strip-lines in a commercial transmission electron microscope

The development of ultrafast electron microscopy (UEM), specifically stroboscopic imaging, has brought the study of structural dynamics to a new level by overcoming the spatial limitations of ultrafast spectroscopy and the temporal restrictions of traditional TEM simultaneously. Combining the concepts governing both techniques has enabled direct visualization of dynamics with spatiotemporal resolutions in the picosecond-nanometer regime. Here, in this study, we push the limits of imaging using a pulsed electron beam via RF induced transverse deflection based on the newly developed 200 keV frequency-tunable strip-line pulser. We demonstrate 0.2 nm spatial resolution at high magnifications and elucidation of Lorentz imaging using the phase-microscopy method. We also present beam coherence measurements and expand our study using the breathing modes of a silicon interdigitated comb under RF excitation which achieves improved temporal synchronization between the electron pulse-train and electric field. A new RF holder has also been developed with impedance matching to the RF signal to minimize transmission power loss to samples and its performance is compared with a conventional sample holder.

47 OTHER INSTRUMENTATION↗

The ABCs of phase retrieval: Connecting the acronyms of scanning transmission electron microscopy

High-resolution scanning transmission electron microscopy (S/TEM) is an indispensable tool for characterizing the structure and properties of materials down to the atomic scale. Conventional S/TEM imaging, however, is limited by the phase problem, whereby the phase of the electron exit wave is lost upon detection. Recent advances in diffractive imaging and 4D-STEM have enabled a range of phase-retrieval techniques that computationally reconstruct the missing information encoded in the phase of the transmission function. These approaches offer improved dose efficiency and enhanced sensitivity to weakly scattering signals, extending quantitative imaging to beam-sensitive materials composed of light elements. In this work, we introduce the phase problem in electron microscopy and survey the diverse landscape of phase-retrieval techniques used in the field. Despite their many acronyms and algorithmic variations, these techniques share a common physical and mathematical foundation. We present a unified framework that connects these seemingly distinct methods, from parallax imaging and tilt-corrected bright-field (tcBF-STEM), to aberration-corrected bright-field (acBF-STEM), optimum bright-field (OBF-STEM) and single-sideband (SSB) ptychography, as well as first-moment integrated center of mass techniques (iCOM) and iterative ptychographic algorithms. Based on these insights, we discuss the opportunities and practical limitations of applying these methods across different materials systems, detector designs, and microscope configurations.Graphical abstractRepresentative electron microscopy configurations used for phase retrieval and diffractive imaging in S/TEM: (a) Zernike phase-contrast transmission electron microscopy (TEM), (b) small-convergence-angle four-dimensional scanning transmission electron microscopy (4D-STEM) for nanobeam-based phase reconstruction methods, and (c) large-convergence-angle 4D-STEM for ptychographic and related diffractive imaging techniques reviewed in this work.

36 MATERIALS SCIENCE↗

Resolving Nanoscale Processes during Carbon Mineralization Using Identical Location Transmission Electron Microscopy

Basalt reservoirs offer the potential for carbon mineralization, aiding in achieving net-zero emissions. However, debates persist about microscopic crystallization mechanisms due to limited characterization techniques under high-temperature and pressure conditions. By using Identical Location Transmission Electron Microscopy (IL-TEM) and cryo-TEM, this study reveals nanoscale interfacial carbonation processes of forsterite and diopside nanoparticles in water-saturated supercritical carbon dioxide under realistic reservoir conditions. Further, both minerals undergo preferential metal cation dissolution into a thin water film, forming porous Si-rich amorphous layers, supporting the leached layer mechanism as the dominant mineral reactivity process. Diopside’s amorphous layer has lower porosity and growth rate relative to forsterite, likely related to the connectivity of silicate tetrahedra. Kinetically favorable nesquehonite and aragonite nanocrystals form on the amorphous layers. These findings support the development of accurate reservoir simulations and help enable commercial-scale carbon storage deployment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Morphological and molecular characterization of a Sarcocystis bovifelis-like sarcocyst in American beef

Abstract Background Parasites in the apicomplexan genusSarcocystisinfect cattle worldwide. Assessing the economic importance of each such parasite species requires proper diagnosis.Sarcocystiscruzi,a thin-walled species, infects virtually all cattle. The prevalence of the other thin-walled parasite,Sarcocystisheydorni, remains less well established. The remaining six species all have thick (> 3 µm) cyst walls (Sarcocystishirsuta,S.hominis,S.bovifelis,S.bovini,S.sigmoideus, andS.rommeli). Thick-walled sarcocysts often induce inflammation in striated muscles (causing bovine eosinophilic myositis), leading to condemnation of carcasses at slaughter. One of these,S.hirsuta, can be seen macroscopically and lead to condemnation of beef. TwoSarcocystisspecies,S.hominisandS.heydorni, are zoonotic. AlthoughS.hominishas been reported as prevalent in Europe, the occurrence of thick-walled species in the US remains poorly known. Here, for the first time to our knowldge, we characterize a thick-walledSarcocystisspecies from a sample of beef from a local grocery store in Maryland. By morphological and genetic criteria, it closely, but not perfectly, resembles parasites previously ascribed toS.bovifelis. Methods Beef samples were examined forSarcocystisinfection, using acid-pepsin digestion to search for bradyzoites, microscopically by compression between a glass slide and coverslip, by histology of paraffin embedded sections stained with hematoxylin and eosin, and by transmission electron microscopy (TEM). Molecular characterization was attempted employing genetic markers:18SrRNA,28SrRNA,cox1,ITS1,gapdh1,ron3, andrpoB. Results Molecular evaluation revealed 100% identity withS.bovifelis-like sarcocysts from naturally infected cattle from Germany and Argentina; although the condition of the frozen material precludes complete characterization by TEM, we noted morphological features which differed from theS.bovifelisoriginally described from experimentally infected cattle from Germany. Conclusions A novelSarcocystisspecies is described from beef from the USA but not named until further evaluation. Graphical Abstract

Parasitology↗

Ultra-Fast Electron Microscopic Imaging of Single Molecules With a Direct Electron Detection Camera and Noise Reduction

Time-resolved imaging of molecules and materials made of light elements is an emerging field of transmission electron microscopy (TEM), and the recent development of direct electron detection cameras, capable of taking as many as 1,600 fps, has potentially broadened the scope of the time-resolved TEM imaging in chemistry and nanotechnology. However, such a high frame rate reduces electron dose per frame, lowers the signal-to-noise ratio (SNR), and renders the molecular images practically invisible. Here, we examined image noise reduction to take the best advantage of fast cameras and concluded that the Chambolle total variation denoising algorithm is the method of choice, as illustrated for imaging of a molecule in the 1D hollow space of a carbon nanotube with ~1 ms time resolution. Through the systematic comparison of the performance of multiple denoising algorithms, we found that the Chambolle algorithm improves the SNR by more than an order of magnitude when applied to TEM images taken at a low electron dose as required for imaging at around 1,000 fps. Open-source code and a standalone application to apply Chambolle denoising to TEM images and video frames are available for download.

47 OTHER INSTRUMENTATION↗

Atomic Resolution Imaging of Light Elements in a Crystalline Environment using Dynamic Hollow-Cone Illumination Transmission Electron Microscopy

Multiple electron scattering and the nonintuitive nature of image formation with coherent radiation complicate the interpretation of conventional transmission electron microscopy images. Precession of the illuminating beam in transmission electron microscopy (TEM) can lead to more robust and interpretable images with some penalty to image contrast, a technique known as dynamic hollow-cone illumination TEM. Here, we demonstrate direct and robust imaging of light and heavy atoms in a crystalline environment with this technique. This method is similar to the annular bright-field technique in scanning transmission electron microscopy, via the principle of reciprocity. Dynamic hollow-cone illumination TEM is challenging in practice due to sensitivity to the misalignment of the precession axis, microscope objective aperture, and crystal zone axis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Towards On-Chip Learning for Low Latency Reasoning with End-to-End Synthesis

The Software Defined Architectures (SODA) Synthesizer is an open-source compiler-based tool able to automatically generate domain-specialized systems targeting Application-Specific Integrated Circuits (ASICs) or Field Programmable Gate Arrays (FPGAs) starting from high-level programming. SODA is composed of a frontend, SODA-OPT, which leverages the multilevel intermediate representation (MLIR) framework to interface with productive programming tools (e.g., machine learning frame-works), identify kernels suitable for acceleration, and perform high-level optimizations, and of a state-of-the-art high-level synthesis backend, Bambu from the PandA framework, to generate custom accelerators. One specific application of the SODA Synthesizer is the generation of accelerators to enable ultra-low latency inference and control on autonomous systems for scientific discovery (e.g., electron microscopes, sensors in particle accelerators, etc.). This paper provides an overview of the flow in the context of the generation of accelerators for edge processing to be integrated in transmission electron microscopy (TEM) devices, focusing on use cases from precision material synthesis. We show the tool in action with an example of design space exploration for inference on reconfigurable devices with a conventional deep neural network model (LeNet). Finally, we discuss the research directions and opportunities enabled by SODA in the area of autonomous control for scientific experimental workflows.

Castellana, Vito G.↗

An Open-Cell Environmental Transmission Electron Microscopy Technique for In Situ Characterization of Samples in Aqueous Liquid Solutions

The desire to image specimens in liquids has led to the development of open-cell and closed-cell techniques in transmission electron microscopy (TEM). The closed-cell approach is currently more common in TEM and has yielded new insights into a number of biological and materials processes in liquid environments. The open-cell approach, which requires an environmental TEM (ETEM), is technically challenging but may be advantageous in certain circumstances due to fewer restrictions on specimen and detector geometry. Here, we demonstrate a novel approach to open-cell liquid TEM, in which we use salt particles to facilitate the in situ formation of droplets of aqueous solution that envelope specimen particles coloaded with the salt. This is achieved by controlling sample temperature between 1 and 10°C and introducing water vapor to the ETEM chamber above the critical pressure for the formation of liquid water on the salt particles. Our use of in situ hydration enables specimens to be loaded into a microscope in a dry state using standard 3 mm TEM grids, allowing specimens to be prepared using trivial sample preparation techniques. Furthermore, our future aim will be to combine this technique with an in situ light source to study photocorrosion in aqueous environments.

47 OTHER INSTRUMENTATION↗

TEM-based phase characterization of $\mathrm{U–19Pu–10Zr}$ irradiated in ATR

We report the results of the microstructural examination of the irradiated U–19Pu–10Zr fuel. New insights gained using selective area electron diffraction analysis in a transmission electron microscope provide crystallographic information on the phases previously identified based primarily on the chemical compositions. After irradiation, the microstructure of the fuel separates into γ-(U, Pu, Zr) in the central region with a secondary nanocrystalline UO 2 phase, γ-(U, Pu, Zr) with a secondary ZrO 2 phase in the intermediate, and ζ-(U, Pu) in the outer regions. While the surface microstructural features and porosity indicate separation into three concentric zones consistent with the existing constituent redistribution model, crystallographically the fuel consists of two zones: inner (with γ-(U, Pu, Zr) as a matrix phase) and outer (with ζ-(U, Pu) as a matrix phase). Our results highlight the importance of crystal structure in phase identification and can be used to supplement the existing constituent redistribution model.

extreme environment↗

Possibility of an integrated transmission electron microscope: enabling complex in-situ experiments

Abstract Multimodal in-situ experiments are the wave of the future, as this approach will permit multispectral data collection and analysis during real-time nanoscale observation. In contrast, the evolution of technique development in the electron microscopy field has generally trended toward specialization and subsequent bifurcation into more and more niche instruments, creating a challenge for reintegration and backward compatibility for in-situ experiments on state-of-the-art microscopes. We do not believe this to be a requirement in the field; therefore, we propose an adaptive instrument that is designed to allow nearly simultaneous collection of data from aberration-corrected transmission electron microscopy (TEM), probe-corrected scanning transmission electron microscopy, ultrafast TEM, and dynamic TEM with a flexible in-situ testing chamber, where the entire instrument can be modified as future technologies are developed. The value would be to obtain a holistic understanding of the underlying physics and chemistry of the process-structure–property relationships in materials exposed to controlled extreme environments. Such a tool would permit the ability to explore, in-situ, the active reaction mechanisms in a controlled manner emulating those of real-world applications with nanometer and nanosecond resolution. If such a powerful tool is developed, it has the potential to revolutionize our materials understanding of nanoscale mechanisms and transients. Graphical Abstract

36 MATERIALS SCIENCE↗

Consequences and Control of Multiscale Order/Disorder in Chiral Magnetic Textures

Transition metal intercalated transition metal dichalcogenides (TMDs) are promising platforms for next-generation spintronic devices based on their wide range of electronic and magnetic phases, which can be tuned by varying the host lattice or intercalant’s identity, stoichiometry, or spatial order. Some of these compounds host a chiral magnetic phase in which the helical winding of magnetic moments propagates along a high-symmetry crystalline axis. Previous studies have demonstrated that variation in intercalant concentrations can have a dramatic effect on the formation of chiral domains and ensemble magnetic properties. However, a systematic and comprehensive study of how atomic-scale order and disorder impact these chiral magnetic textures is so far lacking. Here, we leverage a combination of imaging modes in the (scanning) transmission electron microscope (S/TEM) to directly probe (dis)order across multiple length scales and show how subtle changes in the atomic lattice can tune the mesoscale spin textures and bulk magnetic response in Cr 1/3 NbS 2 , with direct implications for the fundamental understanding and technological implementation of such compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗