Search NASA⌕ Search

SEARCH · Search NASA

Results for “Trapped proton radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Pionener 11 observations of effects of Ganymede and Callisto on Jupiter's trapped radiation

Charged particle data for low-energy protons and electrons from the Pioneer 11 high-latitude flyby of Jupiter in 1974 are reviewed in the light of the Voyager 1 magnetic field model of Connerney et al. (1981). It is found that if the trajectory of Pioneer 11 is mapped to the equatorial plane along the model magnetic field lines, significant features in the time-intensity profiles of trapped protons and electrons, including one microsignaturelike feature, are found to correspond to shells of closed field lines crossed by the orbits of Ganymede and Callisto. It is suggested that these features are signatures of interaction of the trapped particles with Ganymede and Callisto.

Mckibben, R. B.↗

Mission Radiation Environment Modeling and Analysis: Avionics Trade Study for GCD Rad-Neuro Project

The two main objectives of this trade study are characterizing the mission radiation environment for multiple Design Reference Missions (DRM) and analysis of radiation effects on avionics with the goal of producing radiation tolerant Neuromorphic Computing processor chips with innovative radiation-induced fault mitigation. The NASA process for defining radiation requirements for flight avionics is applied to this domain. The effects of trapped protons and electrons in the Van Allen radiation belts predominates in Low-Earth-Orbit (LEO) and the solar wind, solar flares and Galactic Cosmic Rays (GCRs) are the dominant radiation challenge in the open space between the planets of our solar system. The nature and energy of the particles that cause circuit upset and failure is very different in the two regimes. Two results are produced from the radiation models: determining the Total Integrated Dose (TID) experienced by avionics for a given DRM and predicting the Single Event Effects (SEE) rates for avionics during high rate exposure. These tools are applied to existing semiconductors and can be used for predicting the radiation performance of future semiconductors based on early radiation testing of new devices.

Space Radiation↗

Space radiation absorbed dose distribution in a human phantom

The radiation risk to astronauts has always been based on measurements using passive thermoluminescent dosimeters (TLDs). The skin dose is converted to dose equivalent using an average radiation quality factor based on model calculations. The radiological risk estimates, however, are based on organ and tissue doses. This paper describes results from the first space flight (STS-91, 51.65 degrees inclination and approximately 380 km altitude) of a fully instrumented Alderson Rando phantom torso (with head) to relate the skin dose to organ doses. Spatial distributions of absorbed dose in 34 1-inch-thick sections measured using TLDs are described. There is about a 30% change in dose as one moves from the front to the back of the phantom body. Small active dosimeters were developed specifically to provide time-resolved measurements of absorbed dose rates and quality factors at five organ locations (brain, thyroid, heart/lung, stomach and colon) inside the phantom. Using these dosimeters, it was possible to separate the trapped-proton and the galactic cosmic radiation components of the doses. A tissue-equivalent proportional counter (TEPC) and a charged-particle directional spectrometer (CPDS) were flown next to the phantom torso to provide data on the incident internal radiation environment. Accurate models of the shielding distributions at the site of the TEPC, the CPDS and a scalable Computerized Anatomical Male (CAM) model of the phantom torso were developed. These measurements provided a comprehensive data set to map the dose distribution inside a human phantom, and to assess the accuracy and validity of radiation transport models throughout the human body. The results show that for the conditions in the International Space Station (ISS) orbit during periods near the solar minimum, the ratio of the blood-forming organ dose rate to the skin absorbed dose rate is about 80%, and the ratio of the dose equivalents is almost one. The results show that the GCR model dose-rate predictions are 20% lower than the observations. Assuming that the trapped-belt models lead to a correct orbit-averaged energy spectrum, the measurements of dose rates inside the phantom cannot be fully understood. Passive measurements using 6Li- and 7Li-based detectors on the astronauts and inside the brain and thyroid of the phantom show the presence of a significant contribution due to thermal neutrons, an area requiring additional study.

STS-91 Shuttle Project↗

A Comparison of Van Allen Belt Radiation Environment Modeling Programs: AE8/AP8 Legacy, AE9/AP9, and SPENVIS

In the space surrounding Earth there exists an active radiation environment consisting mostly of electrons and protons that have been trapped by Earths magnetic field. This radiation, also known as the Van Allen Belts, has the potential to damage man-made satellites in orbit; thus, proper precautions must be taken to shield NASA assets from this phenomenon. Data on the Van Allen Belts has been collected continuously by a multitude of space-based instruments since the beginning of space exploration. Subsequently, using theory to fill in the gaps in the collected data, computer models have been developed that take in the orbital information of a hypothetical mission and output the expected particle fluence and flux for that orbit. However, as new versions of the modeling system are released, users are left wondering how the new version differs from the old. Therefore, we performed a comparison of three different editions of the modeling system: AE8/AP8 (legacy), which is included in the model 9 graphical user interface as an option for ones calculations, AE9/AP9, and the Space Environment Information System (SPENVIS), which is an online-based form of AE8/AP8 developed by NASA and the European Space Agency that changed the code to allow the program to extrapolate data to predict fluence and flux at higher energies. Although this evaluation is still ongoing, it is predicted that the model 8 (legacy) and SPENVIS version will have identical outputs with the exception of the extended energy levels from SPENVIS, while model 9 will provide different fluences than model 8 based on additional magnetic field descriptions and on-orbit data.

Modeling Programs↗

Design and "As Flown" Radiation Environments for Materials in Low Earth Orbit

A conservative design approach was adopted by the International Space Station Program for specifying total ionizing radiation dose requirements for use in selecting and qualifying materials for construction of the International Space Station. The total ionizing dose design environment included in SSP 30512 Space Station Ionizing Radiation Design Environment is based on trapped proton and electron fluence derived from the solar maximum versions of the AE-8 and AP-8 models, respectively, specified for a circular orbit at 500 km altitude and 51.7 degree inclination. Since launch, the range of altitudes utilized for Space Station operations vary from a minimum of approximately 330 km to a maximum of approximately 405 km with a mean operational altitude less than 400 km. The design environment, therefore, overestimates the radiation environment because the particle flux in the South Atlantic Anomaly is the primary contributor to radiation dose in low Earth orbit and flux within the Anomaly is altitude dependent. In addition, a 2X multiplier is often applied to the design environment to cover effects from the contributions of galactic cosmic rays, solar energetic particle events, geomagnetic storms, and uncertainties in the trapped radiation models which are not explicitly included in the design environment. Application of this environment may give radiation dose overestimates on the order of 1OX to 30X for materials exposed to the space environment, suggesting that materials originally qualified for ten year exposures on orbit may be used for longer periods without replacement. In this paper we evaluate the "as flown" radiation environments derived from historical records of the ISS flight trajectory since launch and compare the results with the SSP 30512 design environment to document the magnitude of the radiation dose overestimate provided by the design environment. "As flown" environments are obtained from application of the AE-8/AP-8 trapped particle models along the ISS flight trajectory including variations in altitude due to decay of the vehicle orbit and periodic reboosts to higher altitudes. In addition, an estimate of the AE-8 model to predict low Earth orbit electron flux (because the radiation dose for thin materials is dominated by the electron component of the radiation environment) is presented based on comparisons of the AE-8 model to measurements of electron integral flux at approximately 850 km from the Medium Energy Proton and Electron Detector on board the NOAA Polar Operational Environmental Satellite.

Minow, Joseph↗

Earth albedo neutrons from 10 to 100 MeV.

We report the measurement of the energy and angular distributions of earth albedo neutrons from 10 to 100 MeV at 40 deg N geomagnetic latitude from a balloon at 120,000 ft, below 4.65 g/sq cm. The albedo-neutron omnidirectional energy distribution is flat to 50 MeV, then decreases with energy. The absolute neutron energy distribution is of the correct strength and shape for the albedo neutrons to be the source of the protons trapped in earth's inner radiation belt.

Preszler, A. M.↗

The AE-8 trapped electron model environment

The machine sensible version of the AE-8 electron model environment was completed in December 1983. It has been sent to users on the model environment distribution list and is made available to new users by the National Space Science Data Center (NSSDC). AE-8 is the last in a series of terrestrial trapped radiation models that includes eight proton and eight electron versions. With the exception of AE-8, all these models were documented in formal reports as well as being available in a machine sensible form. The purpose of this report is to complete the documentation, finally, for AE-8 so that users can understand its construction and see the comparison of the model with the new data used, as well as with the AE-4 model.

Vette, James I.↗

Comparison of Organ Dose and Dose Equivalent Using Ray Tracing of Male and Female Voxel Phantoms to Space Flight Phantom Torso Data

Phantom torso experiments have been flown on the space shuttle and International Space Station (ISS) providing validation data for radiation transport models of organ dose and dose equivalents. We describe results for space radiation organ doses using a new human geometry model based on detailed Voxel phantoms models denoted for males and females as MAX (Male Adult voXel) and Fax (Female Adult voXel), respectively. These models represent the human body with much higher fidelity than the CAMERA model currently used at NASA. The MAX and FAX models were implemented for the evaluation of directional body shielding mass for over 1500 target points of major organs. Radiation exposure to solar particle events (SPE), trapped protons, and galactic cosmic rays (GCR) were assessed at each specific site in the human body by coupling space radiation transport models with the detailed body shielding mass of MAX/FAX phantom. The development of multiple-point body-shielding distributions at each organ site made it possible to estimate the mean and variance of space dose equivalents at the specific organ. For the estimate of doses to the blood forming organs (BFOs), active marrow distributions in adult were accounted at bone marrow sites over the human body. We compared the current model results to space shuttle and ISS phantom torso experiments and to calculations using the CAMERA model.

Kim, Myung-Hee Y.↗

Space Radiation Analysis for the Mark III Spacesuit

NASA has continued the development of space systems by applying and integrating improved technologies that include safety issues, lightweight materials, and electronics. One such area is extravehicular (EVA) spacesuit development with the most recent Mark III spacesuit. In this paper the Mark III spacesuit is discussed in detail that includes the various components that comprise the spacesuit, materials and their chemical composition that make up the spacesuit, and a discussion of the 3-D CAD model of the Mark III spacesuit. In addition, the male (CAM) and female (CAF) computerized anatomical models are also discussed in detail. We combined the spacesuit and the human models, that is, we developed a method of incorporating the human models in the Mark III spacesuit and performed a ray-tracing technique to determine the space radiation shielding distributions for all of the critical body organs. These body organ shielding distributions include the BFO (Blood-Forming Organs), skin, eye, lungs, stomach, and colon, to name a few, for both the male and female. Using models of the trapped (Van Allen) proton and electron environments, radiation exposures were computed for a typical low earth orbit (LEO) EVA mission scenario including the geostationary (GEO) high electron environment. A radiation exposure assessment of these mission scenarios is made to determine whether or not the crew radiation exposure limits are satisfied, and if not, the additional shielding material that would be required to satisfy the crew limits.

Atwell, Bill↗

An Overview of NASA's Risk of Cardiovascular Disease from Radiation Exposure

The association between high doses of radiation exposure and cardiovascular damage is well established. Patients that have undergone radiotherapy for primary cancers of the head and neck and mediastinal regions have shown increased risk of heart and vascular damage and long-term development of radiation-induced heart disease [1]. In addition, recent meta-analyses of epidemiological data from atomic bomb survivors and nuclear industry workers has also shown that acute and chronic radiation exposures is strongly correlated with an increased risk of circulatory disease at doses above 0.5 Sv [2]. However, these analyses are confounded for lower doses by lifestyle factors, such as drinking, smoking, and obesity. The types of radiation found in the space environment are significantly more damaging than those found on Earth and include galactic cosmic radiation (GCR), solar particle events (SPEs), and trapped protons and electrons. In addition to the low-LET data, only a few studies have examined the effects of heavy ion radiation on atherosclerosis, and at lower, space-relevant doses, the association between exposure and cardiovascular pathology is more varied and unclear. Understanding the qualitative differences in biological responses produced by GCR compared to Earth-based radiation is a major focus of space radiation research and is imperative for accurate risk assessment for long duration space missions. Other knowledge gaps for the risk of radiation-induced cardiovascular disease include the existence of a dose threshold, low dose rate effects, and potential synergies with other spaceflight stressors. The Space Radiation Program Element within NASA's Human Research Program (HRP) is managing the research and risk mitigation strategies for these knowledge gaps. In this presentation, we will review the evidence and present an overview of the HRP Risk of Cardiovascular Disease and Other Degenerative Tissue Effects from Radiation Exposure.

Patel, Zarana S.↗

Modelling of Trapped Radiation Near Jupiter

Energetic (62 to approx. 130 MeV) proton fluxes measured with the Galileo Probe inside Jupiter's main ring (radii 122,500 to 128,940 km) show a modest increase as Jupiter is approached. Solutions of a reduced (1-d) equatorial diffusion equation with-constant losses described by a lifetime tau match those data for tau greater than or equal to 10(exp 9) s for diffusion coefficient D(sub LL) = 10(exp -9) L(exp 4)/s, 10(exp -9) L(exp -3)/s, or 10(exp -10) L(exp 4)/s (this particle population may be undergoing nearly loss-free inward radial diffusion). Tau would increase as Jupiter is approached if its value were determined by pitch angle scattering due to EM wave-particle interactions. if the absolute amplitudes of the waves' magnetic fluctuations did not vary with radial distance. Exploration of numerical solutions of the diffusive transport equation for Jupiter's magnetospheric ions at die planetary ring and closer to Jupiter has been done. Explicit range-energy relationships for energy loss in ring matter (SiO2), modeled as a continuous disk, are incorporated. A spatial resolution of approx. 1000 km in the radial direction is used in the vicinity of the main ring; off-equatorial ion fluxes have been included (assuming the atmosphere is a perfect absorber). For protons the maximum effect of energy loss in the microscopic size range of ring particles is expected at energies approx. 0.1 Mev. Presumably there could be sufficiently large, unobserved bodies within the ring that would have to be modeled as discrete objects, as planetary satellites would be. Within limitations of the model and computational resources it's planned to characterize solutions for transport of magnetospheric ions past the planetary ring; the procedures that are used are fairly well known and may be applied generally to the simpler magnetospheric models.

Mihalov, John D.↗

Comparison of Integrated Radiation Transport Models with TEPC Measurements for the Average Quality Factors in Spaceflights

The purpose of this work is to test our theoretical model for the interpretation of radiation data measured in space. During the space missions astronauts are exposed to the complex field of radiation type and kinetic energies from galactic cosmic rays (GCR), trapped protons, and sometimes solar particle events (SPEs). The tissue equivalent proportional counter (TEPC) is a simple time-dependent approach for radiation monitoring for astronauts on board the International Space Station. Another and a newer approach to Microdosimetry is the use of silicon-on-insulator (SOI) technology launched on the MidSTAR-1 mission in low Earth orbit (LEO). In the radiation protection practice, the average quality factor of a radiation field is defined as a function of linear energy transfer (LET), Q(sub ave)(LET). However, TEPC measures the average quality factor as a function of the lineal energy y, Q(sub ave)(y), defined as the average energy deposition in a volume divided by the average chord length of the volume. Lineal energy, y, deviates from LET due to energy straggling, delta-ray escape or entry, and nuclear fragments produced in the detector volume. Monte Carlo track structure simulation was employed to obtain the response of a TEPC irradiated with charged particle for an equivalent site diameter of 1 micron of wall-less counter. The calculated data of the energy absorption in the wall-less counter were compiled for various y values for several ion types at various discrete projectile energy levels. For the simulation of TEPC response from the mixed radiation environments inside a spacecraft, such as, Space Shuttle and International Space Station, the complete microdosimetric TEPC response, f( y, E, Z), were calculated with the Monte Carlo theoretical results by using the first order Lagrangian interpolation for a monovariate function at a given y value (y = 0.1 keV/micron 5000 keV/micron) at any projectile energy level (E = 0.01 MeV/u to 50,000 MeV/u) of each specific radiation type (Z = 1 to 28). Because the anomalous response has been observed at large event sizes in the experiment due to the escape of energy out of sensitive volume by delta-rays and the entry of delta-rays from the high-density wall into the low-density gas-volume cavity, Monte Carlo simulation was also made for the response of a walled-TEPC with wall thickness 2 mm and density 1 g/cm(exp 3). The radius of cavity was set to 6.35 mm and a gas density 7.874 x 10(exp -5) g/cm(exp 3). The response of the walled- and the wall-less counters were compared. The average quality factor Q(sub ave)(y) for trapped protons on STS-89 demonstrated the good agreement between the model calculations and flight TEPC data as shown. Using an integrated space radiation model (this includes the transport codes HZETRN and BRYNTRN, the quantum nuclear interaction model QMSFRG) and the resultant response distribution functions of walled-TEPC from Monte-Carlo track simulations, we compared model calculations with walled-TEPC measurements from NASA missions in LEO and made predictions for the lunar and the Mars missions. The Q(sub ave)(y) values for the trapped or the solar protons ranged from 1.9-2.5. This over-estimates the Qave(LET) values which ranged from 1.4-1.6. Both quantities increase with shield thickness due to nuclear fragmentation. The Q(sub ave)(LET) for the complete GCR spectra was found to be 3.5-4.5, while flight TEPCs measured 2.9-3.4 for Q(sub ave)(y). The GCR values are decreasing with the shield thickness. Our analysis for a proper interpretation of data supports the use of TEPCs for monitoring space radiation environment.

Kim, Myung-Hee Y.↗

Ionizing radiation exposure of LDEF (pre-recovery estimates)

The long duration exposure facility (LDEF), launched into a 258 nautical mile orbit with an inclination of 28.5 degrees, remained in space for nearly 6 yr. The 21,500 lb NASA satellite was one of the largest payloads ever deployed by the Space Shuttle. LDEF completed 32,422 orbits and carried 57 major experiments representing more than 200 investigators from 33 private companies, 21 universities and nine countries. The experiments covered a wide range of disciplines including basic science, electronics, optics, materials, structures and power and propulsion. A number of the experiments were specifically designed to measure the radiation environment. These experiments are of specific interest, since the LDEF orbit is essentially the same as that of the Space Station Freedom. Consequently, the radiation measurements on LDEF will play a significant role in the design of radiation shielding of the space station. The contributions of the various authors presented here attempt to predict the major aspects of the radiation exposure received by the various LDEF experiments and therefore should be helpful to investigators who are in the process of analyzing experiments which may have been affected by exposure to ionizing radiation. The paper discusses the various types and sources of ionizing radiation including cosmic rays, trapped particles (both protons and electrons) and secondary particles (including neutrons, spallation products and high-LET recoils), as well as doses and LET spectra as a function of shielding. Projections of the induced radioactivity of LDEF are also discussed.

Flight Experiment↗

The charged particle radiation environment for AXAF

The Advanced X Ray Astrophysics Facility (AXAF) will be subjected to several sources of charged particle radiation during its 15-year orbital lifetime: geomagnetically-trapped electrons and protons, galactic cosmic ray particles, and solar flare events. These radiation levels are presented for the AXAF orbit for use in the design of the observatory's science instruments.

Joy, Marshall↗

Study of radiation induced deep-level defects in proton irradiated AlGaAs-GaAs solar cells

Radiation induced deep-level defects (both electron and hole traps) in proton irradiated AlGaAs-GaAs p-n junction solar cells are investigated along with the correlation between the measured defect parameters and the solar cell performance parameters. The range of proton energies studied was from 50 KeV to 10 MeV and the proton fluence was varied from 10 to the 10th power to 10 to the 13th power P/sq cm. Experimental tools employed include deep-level transient spectroscopy, capacitance-voltage, current voltage, and SEM-EBIC methods. Defect and recombination parameters such as defect density and energy level, capture cross section, carrier lifetimes and effective hole diffusion lengths in n-GaAs LPE layers were determined from these measurements.

Li, S. S.↗