Search NASA⌕ Search

SEARCH · Search NASA

Results for “ULTRASONICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Interfacial microstructure evolution and weld formation during ultrasonic welding of Al alloy to Cu

Highlights: • Surface oxide layer was fractured and dispersed around the weld interface during ultrasonic welding of Al alloy to Cu. • Mechanical mixing around the weld interface was caused by compressive deformation with ultrasonic vibration. • Once micro-bonds were generated between Al and Cu, shear deformation occurred around the weld interface. • Enhanced Cu diffusion into Al in the severely deformed region significantly contributed to the weld formation. - Abstract: Dissimilar welds of Al alloy 1050 to Cu were prepared via ultrasonic spot welding in order to understand the formation of welds and interfacial microstructures. To observe oxide layer behavior at the weld interface, the anodized Al alloy 1050 was also welded to Cu. Mechanical mixing and material flow during ultrasonic welding broke and dispersed the oxide layers into the Al matrix. This material flow is attributed to compressive deformation that occurred due to ultrasonic vibrations. Direct bonding in the Al/Cu region increased with welding time. Once micro-bonds were generated between Al and Cu, the Al matrix in the vicinity of the weld interface was severely deformed in the direction of the ultrasonic vibrations. Consequently, a recrystallized microstructure with shear texture was formed in the Al matrix. Deformation heating and severe shear deformation formed Al{sub 2}Cu intermetallic compound layers at the weld interface. The growth rate of the Al{sub 2}Cu layer was much faster than had previously been estimated based upon the peak temperature and ultrasonic welding heating time. This is likely due to the increased rate of Cu diffusion into Al in the severely deformed region.

36 MATERIALS SCIENCE↗

Ultrasonic measurement of temperature distributions in extreme environments: Electrical power plants testing in utility-scale steam generators

Thermal heterogeneities within energy conversion and storage, material processing, nuclear processes, aerospace, and military applications are often inaccessible to characterization by insertion sensors. When sensor deployment is possible, conventional pointwise temperature probes quickly degrade when inserted into harsh environments typical of such processes. We developed spatially-resolved ultrasonic thermometry to noninvasively measure the spatial distributions of thermal properties in such applications, even when sizable thermal gradients are present. Our method divides the path of ultrasonic propagation into segments bound by echogenic features, which create echoes in pulse-echo mode, encoding the information about interior temperature distributions. We use the acquired ultrasonic responses to estimate the internal temperature distributions by solving an inverse problem or concatenating segmental estimates. This work describes the implementation and industrial testing of the developed method at a coal-fired electrical power generation plant. We inserted an echogenically segmented Inconel 625 waveguide into the combustion zone of the utility-scale boiler and continuously acquired ultrasonic data while keeping sensitive components away from the damaging combustion environment. The accuracy of the time-dependent temperature distributions reconstructed from the ultrasonic measurements was comparable to that of thermocouples. The resiliency of ultrasonic thermometry to harsh combustion conditions was far superior to conventional insertion sensors. The measurements obtained during plant operation captured daily steam generation cycles in response to changing customer demand and intermittent contributions of renewable power sources to the power grid. These measurements have revealed new insights into the relationship between the dynamic power generation load and the conditions inside the steam generator. As a result, the successful industrial testing of spatially-resolved ultrasonic thermometry in solids indicates that the developed technology has matured to become an attractive alternative to conventional sensing in solving challenging problems of long-term thermal characterizations in extreme environments.

42 ENGINEERING↗

Ultrasonic Measurements of Temperature Profile and Heat Fluxes in Coal-Fired Power Plants (Final Report)

Many industrial processes are inaccessible or inhospitable to characterization by traditional temperature measurement methods, such as thermocouples, especially over prolonged exposure to harsh environments. Ultrasound is an established characterization technology with diverse applications ranging from medical imaging to therapies to flaw detection to nondestructive evaluation. Ultrasound may characterize solid materials and components noninvasively as a nondestructive evaluation modality and obtain internal measurements of material properties. For example, the speed of ultrasound propagation changes with Young’s modulus and Poisson’s ratio, which can be found from its measurements. Traditional ultrasonic characterization assumes all material properties remain constant with the position. When this assumption holds, a property of interest may be measured by relating it to the speed of ultrasound propagation (or a speed of sound, SOS) and measuring the SOS by timing the ultrasound propagation through a known distance. However, when a property of interest is spatially distributed, the propagation time depends on the SOS changing with the position along the ultrasound propagation path. The multiple temperature distributions may lead to an identical time of flight (TOF). Temperature is one property that impacts the speed of ultrasound and often cannot be assumed to remain constant with the position. Previously, in the context of temperature, we addressed the challenge of ultrasonic characterization of spatially distributed properties by developing a method for measuring segmental temperature distributions (MSTD). This method divides the ultrasonic propagation into segments bound by echogenic features. These features provide ultrasonic interfaces where some energy is reflected toward the receiving transducer, and the rest continues through the medium. The time-of-flight between the echoes reflected from echogenic features characterizes the spatial distribution in the properties of interest in the corresponding segment of the ultrasonic propagation path. This project demonstrated the application of the MSTD method in industrial conditions of the coal-fired power plant. We implemented the MSTD using metals and alloys waveguides, which may be the existing structure for which the temperature distribution is characterized or purposefully designed waveguides added to the structure by welding or other means specifically to quantify thermal properties using the MSTD method. Previous iterations of the MSTD method used ceramic and cementitious waveguides, which significantly attenuate ultrasound. On the other hand, low attenuation in metallic waveguides creates interactions between echogenic features which compilates the signal analysis in the segmental TOF measurements. We have established the WG design principles that minimize the interferences between trailing and primary echoes and, in some cases, eliminate them. The waveguides in which echoes do not interfere improve the timing accuracy and the robustness of ultrasonic measurements of the spatial distributions in material properties. Our emphasis remained on the estimation of the temperature distributions. We have developed general recommendations for designing ultrasonically segmented waveguides with the reduced influence of trailing echoes. Two of our waveguide designs were tested in the industry. The first waveguide was designed for insertion into a combustion zone of the utility-scale coal-fired power plant boiler. The second design allows the characterization of temperature distribution in the direction normal to the boiler’s water wall, a large heat exchanger converting the chemical energy released during combustion to the steam driving the electrical power generation turbines. These waveguides were designed to operate within a restrictive space of thermally insulated water wall and incorporate densely located echogenic features while combatting the influence of trailing echoes. The project has successfully demonstrated the feasibility of using the developed method for accurate, continuous, and robust temperature measurements in extreme environments of power generation and other industrial processes. It, therefore, has achieved its overarching goal of advancing the technology readiness level of the novel Ultrasound Measurements of Segmental Temperature Distribution (US-MSTD) method for real-time measurements of the temperature distribution and heat fluxes closer to commercial availability, developing a prototype multipoint measurement system, and validating its performance on coal-fired utility boilers. The success of this project was achieved in collaboration with the power generator, Rocky Mountain Power, and set the stage for the transfer of this technology from the laboratory to the industry.

01 COAL, LIGNITE, AND PEAT↗

Performance Comparison of Machine Learning Models for Ultrasonic Nondestructive Evaluation of Alkali-Silica Reaction in Concrete

Alkali-silica reaction (ASR) causes concrete degradation, leading to cracking, rebar corrosion, and reduced structural integrity, which raises safety concerns. Ultrasonic nondestructive evaluation (NDE) effectively assesses concrete properties and monitors ASR progression. However, its deployment and analysis require specialized expertise and subjective interpretation. As computational power increases, artificial intelligence (AI) and machine learning (ML) algorithms are increasingly being used to automate NDE data analysis across various industries for AI-assisted automation. Regulatory agencies are adapting to this technological shift, prompting a need to evaluate current ML technologies’ capabilities and limitations in assessing concrete material properties and damage. This report presents a comparative analysis of four ML regression models for predicting concrete material damage induced by ASR expansion using long-term ultrasonic data monitoring. The models investigated include linear regression (LR), support vector regression (SVR), shallow neural networks (NN), and deep neural networks (DNN). LR, SVR, and shallow NN models use features extracted from ultrasonic signals, whereas the DNN model processes time-domain ultrasonic signals and frequency spectra directly. The study systematically compared the models’ performance from various perspectives, including model input, prediction performance, and generalization ability. The findings indicate significant variability in model performance, with some ML algorithms achieving very high or very low prediction accuracy depending on the preprocessing and feature engineering (extraction and selection) applied. Key insights include the observation that shallow ML models (LR, SVR, and shallow NNs) require meticulous preprocessing and feature extraction to achieve high accuracy. In contrast, the DNN model, although it bypasses the need for feature engineering, necessitates extensive preprocessing to mitigate noise and computational demands. The SVR model emerged as the top performer among the shallow models, and the DNN model exhibited superior performance on specific datasets but struggled with generalization across specimens from different batches. Additionally, the SVR model is sensitive to temperature variations, whereas the DNN model is robust in this regard. Using recurrent neural networks is recommended for future ASR expansion prediction studies. Recurrent neural networks’ inherent ability to capture temporal dependencies and long-term patterns makes them well suited for analyzing sequential ultrasonic monitoring data. Overall, the results and conclusions of this study could provide insights into the capabilities and effectiveness of ML when applied to ultrasonic NDE data and help identify best practices for using ML for ultrasonic NDE of concrete material properties.

36 MATERIALS SCIENCE↗

Assessment of damage in ceramics and ceramic matrix composites using ultrasonic techniques

This paper addresses the application of ultrasonic sensing to damage assessment in ceramics and ceramic matrix composites. It focuses on damage caused by thermal shock or oxidation at elevated temperatures, which often results in elastic anisotropy. This damaged-induced anisotropy is determined by measuring the velocities of ultrasonic waves in different propagation directions. Thermal shock damage is assessed in ceramic samples of reaction bonded silicon nitride (RBSN). Thermal shock treatment from different temperatures up to 1000 C is applied to produce the microcracks. Results indicate that most microcracks produced by thermal shock are located near sample surfaces. Ultrasonic measurements using the surface wave method are found to correlate well with measurements of degradation of mechanical properties obtained independently by other authors using destructive methods. Oxidation damage is assessed in silicon carbide fiber/reaction bonded silicon nitride matrix (SCS-6/RBSN) composites. The oxidation is done by exposing the samples in a flowing oxygen environment at elevated temperatures, up to 1400 C, for 100 hr. The Youngs' modulus in the fiber direction as obtained from ultrasonic measurements decreases significantly at 600 C but retains its original value at temperatures above 1200 C. This agrees well with the results of destructive tests by other authors. On the other hand, the transverse moduli obtained from ultrasonic measurements decrease continually until 1200 C. Measurements on the shear stiffnesses show behavior similar to the transverse moduli. The results of this work show that the damage-induced anisotropy in both ceramics and ceramic matrix composites can be determined successfully by ultrasonic methods. This suggests the possibility of assessing damage severity using ultrasonic techniques.

Chu, Y. C.↗

High-Performance Acousto-Ultrasonic Scan System Being Developed

Acousto-ultrasonic (AU) interrogation is a single-sided nondestructive evaluation (NDE) technique employing separated sending and receiving transducers. It is used for assessing the microstructural condition and distributed damage state of the material between the transducers. AU is complementary to more traditional NDE methods, such as ultrasonic cscan, x-ray radiography, and thermographic inspection, which tend to be used primarily for discrete flaw detection. Throughout its history, AU has been used to inspect polymer matrix composites, metal matrix composites, ceramic matrix composites, and even monolithic metallic materials. The development of a high-performance automated AU scan system for characterizing within-sample microstructural and property homogeneity is currently in a prototype stage at NASA. This year, essential AU technology was reviewed. In addition, the basic hardware and software configuration for the scanner was developed, and preliminary results with the system were described. Mechanical and environmental loads applied to composite materials can cause distributed damage (as well as discrete defects) that plays a significant role in the degradation of physical properties. Such damage includes fiber/matrix debonding (interface failure), matrix microcracking, and fiber fracture and buckling. Investigations at the NASA Glenn Research Center have shown that traditional NDE scan inspection methods such as ultrasonic c-scan, x-ray imaging, and thermographic imaging tend to be more suited to discrete defect detection rather than the characterization of accumulated distributed micro-damage in composites. Since AU is focused on assessing the distributed micro-damage state of the material in between the sending and receiving transducers, it has proven to be quite suitable for assessing the relative composite material state. One major success story at Glenn with AU measurements has been the correlation between the ultrasonic decay rate obtained during AU inspection and the mechanical modulus (stiffness) seen during fatigue experiments with silicon carbide/silicon carbide (SiC/SiC) ceramic matrix composite samples. As shown in the figure, ultrasonic decay increased as the modulus decreased for the ceramic matrix composite tensile fatigue samples. The likely microstructural reason for the decrease in modulus (and increase in ultrasonic decay) is the matrix microcracking that commonly occurs during fatigue testing of these materials. Ultrasonic decay has shown the capability to track the pattern of transverse cracking and fiber breakage in these composites.

Roth, Don J.↗

High-Performance Acousto-Ultrasonic Scan System Being Developed

Acousto-ultrasonic (AU) interrogation is a single-sided nondestructive evaluation (NDE) technique employing separated sending and receiving transducers. It is used for assessing the microstructural condition and distributed damage state of the material between the transducers. AU is complementary to more traditional NDE methods, such as ultrasonic cscan, x-ray radiography, and thermographic inspection, which tend to be used primarily for discrete flaw detection. Throughout its history, AU has been used to inspect polymer matrix composites, metal matrix composites, ceramic matrix composites, and even monolithic metallic materials. The development of a high-performance automated AU scan system for characterizing within-sample microstructural and property homogeneity is currently in a prototype stage at NASA. This year, essential AU technology was reviewed. In addition, the basic hardware and software configuration for the scanner was developed, and preliminary results with the system were described. Mechanical and environmental loads applied to composite materials can cause distributed damage (as well as discrete defects) that plays a significant role in the degradation of physical properties. Such damage includes fiber/matrix debonding (interface failure), matrix microcracking, and fiber fracture and buckling. Investigations at the NASA Glenn Research Center have shown that traditional NDE scan inspection methods such as ultrasonic c-scan, x-ray imaging, and thermographic imaging tend to be more suited to discrete defect detection rather than the characterization of accumulated distributed microdamage in composites. Since AU is focused on assessing the distributed microdamage state of the material in between the sending and receiving transducers, it has proven to be quite suitable for assessing the relative composite material state. One major success story at Glenn with AU measurements has been the correlation between the ultrasonic decay rate obtained during AU inspection and the mechanical modulus (stiffness) seen during fatigue experiments with silicon carbide/silicon carbide (SiC/SiC) ceramic matrix composite samples. As shown in the figure, ultrasonic decay increased as the modulus decreased for the ceramic matrix composite tensile fatigue samples. The likely microstructural reason for the decrease in modulus (and increase in ultrasonic decay) is the matrix microcracking that commonly occurs during fatigue testing of these materials. Ultrasonic decay has shown the capability to track the pattern of transverse cracking and fiber breakage in these composites.

Roth, Don J.↗

Wire Crimp Termination Verification Using Ultrasonic Inspection

The development of a new ultrasonic measurement technique to quantitatively assess wire crimp terminations is discussed. The amplitude change of a compressional ultrasonic wave propagating through the junction of a crimp termination and wire is shown to correlate with the results of a destructive pull test, which is a standard for assessing crimp wire junction quality. Various crimp junction pathologies such as undercrimping, missing wire strands, incomplete wire insertion, partial insulation removal, and incorrect wire gauge are ultrasonically tested, and their results are correlated with pull tests. Results show that the nondestructive ultrasonic measurement technique consistently (as evidenced with destructive testing) predicts good crimps when ultrasonic transmission is above a certain threshold amplitude level. A physics-based model, solved by finite element analysis, describes the compressional ultrasonic wave propagation through the junction during the crimping process. This model is in agreement within 6% of the ultrasonic measurements. A prototype instrument for applying this technique while wire crimps are installed is also presented. The instrument is based on a two-jaw type crimp tool suitable for butt-splice type connections. Finally, an approach for application to multipin indenter type crimps will be discussed.

Perey, Daniel F.↗

Apparatus for acoustically coupling an ultrasonic transducer with a body

An apparatus for acoustically coupling an ultrasonic transducer with a body along whose surface waves are to be transmitted includes a wedge having a first surface for acoustically contacting a subject surface area of a body to be measured, on which surface waves are to be transmitted, and a second surface for accoustically contacting an ultrasonic transducer. The wedge includes a cylinder in which the second surface is present and which is movably disposed in a recess in a block in which the first surface is present, for orienting the first surface and the second surface relative to each other so that ultrasonic waves emitted by the ultrasonic transducer generate surface waves which travel on the subject surface area of the body when the ultrasonic transducer is in acoustic contact with the second surface and the first surface is in acoustic contact with the subject surface area of the body. In the preferred embodiment, there is a third surface which is orientable relative to the first surface so that ultrasonic waves emitted by an ultrasonic transducer in contact with the third surface generate surface waves which travel on the subject surface area of the body when the first surface is an acoustic contact with the subject surface area of the body.

Marshall, Scot H.↗

Wire Crimp Connectors Verification using Ultrasonic Inspection

The development of a new ultrasonic measurement technique to quantitatively assess wire crimp connections is discussed. The amplitude change of a compressional ultrasonic wave propagating through the junction of a crimp connector and wire is shown to correlate with the results of a destructive pull test, which previously has been used to assess crimp wire junction quality. Various crimp junction pathologies (missing wire strands, incorrect wire gauge, incomplete wire insertion in connector) are ultrasonically tested, and their results are correlated with pull tests. Results show that the ultrasonic measurement technique consistently (as evidenced with pull-testing data) predicts good crimps when ultrasonic transmission is above a certain threshold amplitude level. A physics-based model, solved by finite element analysis, describes the compressional ultrasonic wave propagation through the junction during the crimping process. This model is in agreement within 6% of the ultrasonic measurements. A prototype instrument for applying the technique while wire crimps are installed is also presented.

Cramer, K. Elliott↗

Micro-Horn Arrays for Ultrasonic Impedance Matching

Thin-layered structures containing arrays of micromachined horns, denoted solid micro-horn arrays (SMIHAs), have been conceived as improved means of matching acoustic impedances between ultrasonic transducers and the media with which the transducers are required to exchange acoustic energy. Typically, ultrasonic transducers (e.g., those used in medical imaging) are piezoelectric or similar devices, which produce small displacements at large stresses. However, larger displacements at smaller stresses are required in the target media (e.g., human tissues) with which acoustic energy is to be exchanged. Heretofore, efficiencies in transmission of acoustic energy between ultrasonic transducers and target media have been severely limited because substantial mismatches of acoustic impedances have remained, even when coupling material layers have been interposed between the transducers and the target media. In contrast, SMIHAs can, in principle, be designed to effect more nearly complete acoustic impedance matching, leading to power transmission efficiencies of 90 percent or even greater. The SMIHA concept is based on extension, into the higher-frequency/ lower-wavelength ultrasonic range, of the use of horns to match acoustic impedances in the audible and lower-frequency ultrasonic ranges. In matching acoustic impedance in transmission from a higher-impedance acoustic source (e.g., a piezoelectric transducer) and a lowerimpedance target medium (e.g., air or human tissue), a horn acts as a mechanical amplifier. The shape and size of the horn can be optimized for matching acoustic impedance in a specified frequency range. A typical SMIHA would consist of a base plate, a face plate, and an array of horns that would constitute pillars that connect the two plates (see figure). In use, the base plate would be connected to an ultrasonic transducer and the face plate would be placed in contact with the target medium. As at lower frequencies, the sizes and shapes of the pillars could be tailored for impedance matching in a specified ultrasonic frequency range. In a design that would be simplest to implement by micromachining, the horns would have constant cross-sectional areas as shown in the upper part of the figure. In this case, the dimensions of the horns could be chosen on the basis of a Mason equivalent-circuit model (a simplified model, well-known in the piezoelectric-transducer art, in which the electrical and mechanical dynamics, including electromechanical couplings, are expressed as electrical circuit elements that can include inductors, capacitors, and lumped-parameter complex impedances.) In a more complex, more nearly optimum design, the cross-sectional area of each horn would be either stepped or made to vary as a continuous function of through-the thickness position, as shown in the lower part of the figure.

Rao, Shanti↗

An Analysis of Peak Wind Speed Data from Collocated Mechanical and Ultrasonic Anemometers

This study compared peak wind speeds reported by mechanical and ultrasonic anemometers at Cape Canaveral Air Force Station and Kennedy Space Center (CCAFS/KSC) on the east central coast of Florida and Vandenberg Air Force Base (VAFB) on the central coast of California. Launch Weather Officers, forecasters, and Range Safety analysts need to understand the performance of wind sensors at CCAFS/KSC and VAFB for weather warnings, watches, advisories, special ground processing operations, launch pad exposure forecasts, user Launch Commit Criteria (LCC) forecasts and evaluations, and toxic dispersion support. The legacy CCAFS/KSC and VAFB weather tower wind instruments are being changed from propeller-and-vane (CCAFS/KSC) and cup-and-vane (VAFB) sensors to ultrasonic sensors under the Range Standardization and Automation (RSA) program. Mechanical and ultrasonic wind measuring techniques are known to cause differences in the statistics of peak wind speed as shown in previous studies. The 45th Weather Squadron (45 WS) and the 30th Weather Squadron (30 WS) requested the Applied Meteorology Unit (AMU) to compare data between the RSA ultrasonic and legacy mechanical sensors to determine if there are significant differences. Note that the instruments were sited outdoors under naturally varying conditions and that this comparison was not designed to verify either technology. Approximately 3 weeks of mechanical and ultrasonic wind data from each range from May and June 2005 were used in this study. The CCAFS/KSC data spanned the full diurnal cycle, while the VAFB data were confined to 1000-1600 local time. The sample of 1-minute data from numerous levels on five different towers on each range totaled more than 500,000 minutes of data (482,979 minutes of data after quality control). The ten towers were instrumented at several levels, ranging from 12 ft to 492 ft above ground level. The ultrasonic sensors were collocated at the same vertical levels as the mechanical sensors and typically within 15 ft horizontally of each another. Data from a total of 53 RSA ultrasonic sensors, collocated with mechanical sensors were compared. The 1- minute average wind speed/direction and the 1-second peak wind speed/direction were compared.

Short, David A.↗

Ultrasonic Clothes Washer/Dryer Combination for Moon, Mars and ISS Applications

Our study aims to investigate the effectiveness of an ultrasonic-based combo garment washing and drying system for space applications. Our system leverages our technological innovations in direct-contact ultrasonic fabric drying in combination with ultrasonic fabric washing. The main objective of this investigation is to gauge the effectiveness of washing & drying textile garments ultrasonically. In this paper, we will report the results of experiments conducted to assess the effectiveness of washing clothes ultrasonically, including ultrasonic intensity testing, stain removal testing, and fabric degradation testing. This study's outcome could lead to the production of an Ultra-Fast Ultrasonic Washer/Dryer Combination unit that could reduce clothing resupply costs for crewed missions to the Moon, Mars, and the ISS.

washer↗

Initial Testing of a Full-Scale Ultrasonic Clothes Washer/Dryer for Moon, Mars, ISS and Beyond

This study investigates the effectiveness of an ultrasonic-based combo garment washing and drying system for space applications. The system leverages our technological innovations in direct-contact ultrasonic fabric drying in combination with ultrasonic fabric washing. The main objective of this investigation is to gauge the effectiveness of washing and drying medium-size T-shirts ultrasonically. This paper will report the results of experiments conducted to assess the effectiveness of washing clothes ultrasonically, including ultrasonic intensity testing, stain removal testing, and fabric degradation testing. The outcome of this study could lead to the design and development of the first ultrasonic clothes washer and dryer for space applications that would reduce clothing resupply costs for crewed missions to the moon, Mars, and micro-gravity space stations.

Crew systems↗

Initial Testing of a Full-Scale Ultrasonic Clothes Washer/Dryer for Moon, Mars, ISS and Beyond

This study investigates the effectiveness of an ultrasonic-based combo garment washing and drying system for space applications. The system leverages our technological innovations in direct-contact ultrasonic fabric drying in combination with ultrasonic fabric washing. The main objective of this investigation is to gauge the effectiveness of washing and drying medium-size T-shirts ultrasonically. This paper will report the results of experiments conducted to assess the effectiveness of washing clothes ultrasonically, including ultrasonic intensity testing, stain removal testing, and fabric degradation testing. The outcome of this study could lead to the design and development of the first ultrasonic clothes washer and dryer for space applications that would reduce clothing resupply costs for crewed missions to the moon, Mars, and micro-gravity space stations.

Crew systems↗

Performance Evaluation of High-Temperature Ultrasonic Communication System

Ultrasonic communication is a technique that allows transmitting information through a solid material such as tubes or bars using high-frequency elastic waves. The communication channels often extend into a high-temperature range in the field of power, oil, or nuclear industry. When the temperature is taken into consideration, the ultrasonic wave propagation through the solid channel is complex and unpredictable. It is necessary to study the influence of temperature on the ultrasonic guided wave to improve ultrasonic communication. In this study, a temperature control system is assembled to adjust the temperature of a steel pipe channel ranging from room temperature to 150 degrees C. The temperature performance evaluation is conducted to estimate the signal-to-noise ratio (SNR) and bit error rate (BER) of transferring the ultrasonic signal. The work aims to develop a reliable ultrasonic communication system in a high-temperature environment. The system temperature can be maintained at 150 degrees C and the LiNbO3 transducers are used as transmitters and receivers. No power amplifier is used in the communication system. The high-temperature ultrasonic communication system (HT-UCS) is feasible at 150 degrees C and can achieve a bit rate of 10 kbps without any error.

HT-UCS↗

LASER-ULTRASONIC TESTING AND ITS APPLICATIONS TO NUCLEAR REACTOR INTERNALS

A new nondestructive testing technique for surface-breaking microcracks in nuclear reactor components based on laser-ultrasonics is developed. Surface acoustic wave generated by Q-switched Nd:YAG laser and detected by frequency-stabilized long pulse laser coupled with confocal Fabry-Perot interferometer is used to detect and size the cracks. A frequency-domain signal processing is developed to realize accurate sizing capability. The laser-ultrasonic testing allows the detection of surface-breaking microcrack having a depth of less than 0.1 mm, and the measurement of their depth with an accuracy of 0.2 mm when the depth exceeds 0.5 mm including stress corrosion cracking. The laser-ultrasonic testing system combined with laser peening system, which is another laser-based maintenance technology to improve surface stress, for inner surface of small diameter tube is developed. The generation laser in the laser-ultrasonic testing system can be identical to the laser source of the laser peening. As an example operation of the system, the system firstly works as the laser-ultrasonic testing mode and tests the inner surface of the tube. If no cracks are detected, the system then changes its work mode to the laser peening and improves surface stress to prevent crack initiation. The first nuclear industrial application of the laser-ultrasonic testing system combined with the laser peening was completed in Japanese nuclear power plant in December 2004.

36 MATERIALS SCIENCE↗

Experimental Investigation on Acoustic Control Droplet Transfer in Ultrasonic-Wave-Assisted Gas Metal Arc Welding

Ultrasonic-wave-assisted gas metal arc welding (U-GMAW) is a new, advanced arc welding method that uses an ultrasonic wave emitted from an ultrasonic radiator above the arc. However, it remains unclear how the ultrasonic wave affects the metal droplet, hindering further application of U-GMAW. In this paper, an improved U-GMAW system was used and its superiority was experimentally demonstrated. Then a series of experiments were designed and performed to study how the ultrasonic wave affects droplet transfer, including droplet size, velocity, and motion trajectory. The behavior of droplet transfer was observed in high-speed images. The droplet transfer is closely related to the distribution of the acoustic field, determined by the ultrasonic current. Moreover, by analyzing the variably accelerated motion of the droplet, the acoustic control of the droplet transfer was intuitively demonstrated. Finally, U-GMAW was successfully used in vertical-up and overhead welding experiments, showing that U-GMAW is promising for use in welding in all positions.

36 MATERIALS SCIENCE↗