Search NASA⌕ Search

SEARCH · Search NASA

Results for “UNIFORM FLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Comparing Commercial and Research Computational Fluid Dynamic Codes Using High-Order Workshop Benchmark Problems

The commercial computational fluid dynamic (CFD) code ANSYS Fluent and multiple research CFD codes (ez4d with uses the conservation element and solution element (CESE) method and codes that use the flux reconstruction (FR) method) were tested using three different benchmark problems from the International Workshop for High-Order CFD Methods. The benchmark problems included the transonic Ringleb flow, vortex transport by uniform flow, and laminar boundary layer on a flat plate. Simulation results from all three benchmark problems showed that the Fluent solutions had less error than the ez4d solutions for a given degree of freedom. As expected, both the Fluent and ez4d solutions had larger errors for a given degree of freedom than the simulations that used the FR method because both Fluent and ez4d utilized a second-order scheme whereas the FR codes utilized a fourth-order scheme.

CFD↗

Flow Characterization Studies of the 10-MW TP3 Arc-Jet Facility: Probe Sweeps

This paper reports computational simulations and analysis in support of calibration and flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted in the NASA Ames 10-MW TP3 facility using flat-faced stagnation calorimeters at six conditions corresponding to the steps of a simulated flight heating profile. Data were obtained using a conical nozzle test configuration in which the models were placed in a free jet downstream of the nozzle. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were also performed at these arc-heater conditions, providing assessment of the flow uniformity and valuable data for the flow characterization. Two different sets of pitot pressure and heat probes were used: 9.1-mm sphere-cone probes (nose radius of 4.57 mm or 0.18 in) with null-point heat flux gages, and 15.9-mm (0.625 in) diameter hemisphere probes with Gardon gages. The probe survey data clearly show that the test flow in the TP3 facility is not uniform at most conditions (not even axisymmetric at some conditions), and the extent of non-uniformity is highly dependent on various arc-jet parameters such as arc current, mass flow rate, and the amount of cold-gas injection at the arc-heater plenum. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. Comparisons of computations with the experimental measurements show reasonably good agreement except at the extreme low pressure conditions of the facility envelope.

Goekcen, Tahir↗

Flow Characterization Studies of the 10-MW TP3 Arc-Jet Facility: Probe Sweeps

This paper reports computational simulations and analysis in support of calibration and flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted in the NASA Ames 10-MW TP3 facility using flat-faced stagnation calorimeters at six conditions corresponding to the steps of a simulated flight heating profile. Data were obtained using a conical nozzle test configuration in which the models were placed in a free jet downstream of the nozzle. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were also performed at these arc-heater conditions, providing assessment of the flow uniformity and valuable data for the flow characterization. Two different sets of pitot pressure and heat probes were used: 9.1-mm sphere-cone probes (nose radius of 4.57 mm or 0.18 in) with null-point heat flux gages, and 15.9-mm (0.625 in) diameter hemisphere probes with Gardon gages. The probe survey data clearly show that the test flow in the TP3 facility is not uniform at most conditions (not even axisymmetric at some conditions), and the extent of non-uniformity is highly dependent on various arc-jet parameters such as arc current, mass flow rate, and the amount of cold-gas injection at the arc-heater plenum. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. Comparisons of computations with the experimental measurements show reasonably good agreement except at the extreme low pressure conditions of the facility envelope.

CFD↗

CFD Simulations of the AEDC H3 Arc-Jet Flow: Mach 3.3 Nozzle, Flow Surveys, Wedge Models

This paper reports computational simulations and analysis of tests in a high enthalpy arc-jet facility at Arnold Engineering Development Center. These tests were conducted using wedge models placed in a free jet downstream of a 4.5-inch diameter contoured Mach 3.3 nozzle in the H3 facility. For calibration of test conditions, one wedge calibration plate instrumented with an array of pressure and coaxial thermocouple heat flux gages, one stagnation pressure probe and two null-point heat flux calorimeters were used. The pitot pressure and null-point probe measurements give experimental surveys of the test flow, providing assessment of the flow uniformity and valuable data for flow characterization. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle, into the test box and over the wedge models, and comparisons with the experimental measurements. Several issues related to testing are considered: test flow characterization, prediction of surface quantities for three wedge models, effects of model shape change and test article recession, and prediction of surface quantities for the test articles with two circular cavities. These simulations take into account non-uniform total enthalpy profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the wedge model flowfields.

Arc-jet testing↗

Optimization of suppression for two-element treatment liners for turbomachinery exhaust ducts

Sound wave propagation in a soft-walled rectangular duct with steady uniform flow was investigated at exhaust conditions, incorporating the solution equations for sound wave propagation in a rectangular duct with multiple longitudinal wall treatment segments. Modal analysis was employed to find the solution equations and to study the effectiveness of a uniform and of a two-sectional liner in attenuating sound power in a treated rectangular duct without flow (M = 0) and with uniform flow of Mach 0.3. Two-segment liners were shown to increase the attenuation of sound as compared to a uniform liner. The predicted sound attenuation was compared with measured laboratory results for an optimized two-segment suppressor. Good correlation was obtained between the measured and predicted suppressions when practical variations in the modal content and impedance were taken into account. Two parametric studies were also completed.

Motsinger, R. E.↗

Three-dimensional potential flow over hills and oval mounds

An analysis was made of the potential flow behavior for an initially uniform flow passing over a single axisymmetric hill, an oval mound, and a combination of two hills. Small perturbation theory was used, and the resulting Laplace equation for the perturbation velocity potential was solved by using either a product solution or a Green's function. The three dimensional solution is of interest in calculating the pressure distribution around obstacles, the flow of pollutants carried by the wind, and the augmentation of wind velocity for windmill siting. The augmentation in velocity at the top of a hill was found to be proportional to the hill height relative to a characteristic width dimension of the hill. An axisymmetric hill produced about 20 percent less velocity increase than a two dimensional ridge having the same cross-sectional profile.

Siegel, R.↗

Force Evaluation in the Lattice Boltzmann Method Involving Curved Geometry

The present work investigates two approaches for force evaluation in the lattice Boltzmann equation: the momentum- exchange method and the stress-integration method on the surface of a body. The boundary condition for the particle distribution functions on curved geometries is handled with second order accuracy based on our recent works. The stress-integration method is computationally laborious for two-dimensional flows and in general difficult to implement for three-dimensional flows, while the momentum-exchange method is reliable, accurate, and easy to implement for both two-dimensional and three-dimensional flows. Several test cases are selected to evaluate the present methods, including: (i) two-dimensional pressure-driven channel flow; (ii) two-dimensional uniform flow past a column of cylinders; (iii) two-dimensional flow past a cylinder asymmetrically placed in a channel (with vortex shedding); (iv) three-dimensional pressure-driven flow in a circular pipe; and (v) three-dimensional flow past a sphere. The drag evaluated by using the momentum-exchange method agrees well with the exact or other published results.

Mei, Renwei↗

Analysis and Design of Rectangular-Cross-Section Nozzles for Scramjet Engine Testing

The flow in the square-cross-section Mach-6 nozzle used in the NASA Langley Research Center Arc-Heated Scramjet Test Facility has been analyzed using three-dimensional viscous CFD methods. The primary cause of the non-uniform flow exiting the nozzle is identified as cross-flow pressure gradients imposed on wall boundary layers. The cross-flow pressure gradients cause the boundary layer to roll up into counter-rotating vortex pairs on each of the four sides of the nozzle. These four vortex pairs produce significant non-uniformity in the nozzle-exit flow. In order to improve the quality of the test flow in the facility, two alternative nozzle designs (one axisymmetric and one rectangular with a 2-D contour) have been investigated. While the axisymmetric design produced the most uniform flow, the 2-D design also produced very good flow. The 2-D design was selected for further refinement, resulting in a new nozzle design which has been constructed and awaits calibration.

Gaffney, Richard L., Jr.↗

Comparison of a Convected Helmholtz and Euler Model for Impedance Eduction in Flow

Impedances educed from a well-tested convected Helmholtz model are compared to that of a recently developed linearized Euler model using two ceramic test liners under the assumed conditions or uniform flow and a plane wave source. The convected Helmholtz model is restricted to uniform mean flow whereas the linearized Euler model can account for the effect or the shear layer. Test data to educe the impedance is acquired from measurements obtained in the NASA Langley Research Center Grazing Incidence Tube for mean flow Mach numbers ranging from 0.0 to 0.5 and source frequencies ranging from 0.5 kHz to 3.0 kHz. The unknown impedance of the liner b educed by judiciously choo~ingth e impedance via an optimization method to match the measured acoustic pressure on the wall opposite the test liner. Results are presented on four spatial grids using three different optimization methods (contour deformation, Davidon-Fletcher Powell, and the Genetic Algorithm). All three optimization methods converge to the same impedance when used with the same model and to nearly identical impedances when used on different models. h anomaly was observed only at 0.5 kHz for high mean flow speeds. The anomaly is likely due to the use of measured data in a flow regime where shear layer effects are important but are neglected in the math models. Consistency between the impedances educed using the two models provides confidence that the linearized Euler model is ready For application to more realistic flows, such as those containing shear layers.

Watson, Willie R.↗

Design and fabrication of brayton cycle solar heat receiver

A detail design and fabrication of a solar heat receiver using lithium fluoride as the heat storage material was completed. A gas flow analysis was performed to achieve uniform flow distribution within overall pressure drop limitations. Structural analyses and allowable design criteria were developed for anticipated environments such as launch, pressure containment, and thermal cycling. A complete heat receiver assembly was fabricated almost entirely from the refractory alloy, niobium-1% zirconium.

Mendelson, I.↗

Response of a stably stratified atmosphere to low-level heating - An application to the heat island problem

Two-dimensional airflow characteristics past a heat island are investigated using both a linear analytic model and a nonlinear numerical model in the context of the response of a stably stratified atmosphere to specified low-level heating in a constant shear flow. Results from the steady-state, linear, analytic solutions exhibit typical flow response fields that gravity waves produce in response to the local heat source in the presence of environmental flow. The magnitude of the perturbation vertical velocity is shown to be much larger in the shear-flow case than in the uniform-flow case. Two distinct flow features are observed for larger heating amplitude (hence, larger nonlinearity factor): the gravity-wave-type response field on the upstream side of the heat island and the strong updraft circulation cell located on the downstream side. As the heating amplitude increases, the updraft circulation cell strengthens and shifts farther downwind. The strong updraft cell is believed to be partly responsible for precipitation enhancement observed on the downstream side of the heat island. It is found that the continuing downwind propagation of the updraft circulation cell is related to basic-state wind speed.

Baik, Jong-Jin↗

Computational Simulations of the 10-MW TP3 Arc-Jet Facility Flow

This paper reports computational simulations and analysis in support of calibration tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted using stagnation calorimeters and two different blunted wedge models with calibration plates at a wide range of conditions in the NASA Ames 10-megawatt TP3 (Test Position 3) facility. Data were obtained using four different conical nozzles with the same test configuration in which the models were placed in a free jet downstream of the nozzle. Experimental surveys of arc-jet test flow with pitot and null-point heat flux probes were also performed at several arc-heater conditions, providing assessment of the flow uniformity and valuable data for the flow characterization. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested, and comparisons with the experimental measurements. These computational simulations provide estimates of the arc-jet test environment parameters that are not measured but are needed to evaluate the performance of thermal protection system materials, along with further valuable insights into the arc-jet testing environment. Simulation results are used to estimate centerline total enthalpy, surface shear, boundary layer thickness, and boundary layer edge Mach number and to verify that specific test requirements from the Orion program are met.

CFD↗

CFD Simulations of the IHF Arc-Jet Flow: 9-Inch Nozzle, Flow Surveys, LEAF Wedge Calibration Data

This paper reports computational analyses and flow characterization studies in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted using a wedge model placed in a free jet downstream of new 9-inch diameter conical nozzle in the Ames 60-MW Interaction Heating Facility. Both the nozzle and wedge model were specifically designed for testing in the new Laser-Enhanced Arc-jet Facility. Data were obtained using stagnation calorimeters and wedge models placed downstream of the nozzle exit. Two instrumented wedge calibration plates were used: one water-cooled and the other RCG-coated tile plate. Experimental surveys of arc-jet test flow with pitot and heat flux probes were also performed at three arc-heater conditions, providing assessment of the flow uniformity and valuable data for the flow characterization. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested, and comparisons with the experimental measurements. By taking into account nonuniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields, these simulations approximately reproduce the probe survey data and predict the wedge model surface pressure and heat flux measurements.

Arc-jets↗

Arcjet Supplemental Diagnostics

This document proposes a new set of diagnostics designed to be implemented on the NASA Ames miniature Arcjet Research Chamber (mARC) for improved characterization of the flow. The diagnostics are grouped into three classes:higher cadence measurements, higher spatial resolution, and computer vision techniques for improved analysis of existing imaging. The goal is to better understand and quantify the following properties: flow statistics/uncertainty, temporal & spatial non-uniformity, flow temperature/enthalpy

Haw, Magnus A.↗

Interaction of strong shock wave with turbulent boundary layer

The reported investigation represents an extension of the time-dependent solution of separated laminar flows based on the complete Navier-Stokes equations reported by MacCormack (1971) and Carter (1973). The current study includes turbulence models in conjunction with the compressible flow equations. The calculations start with a uniform flow except for values imposed along the upstream and outer boundaries. The basic numerical method is discussed along with questions concerning the exponential accuracy and the resolution of the viscous sublayer in a compressed region.

Baldwin, B. S.↗

CFD Study of Turbo-Ramjet Interactions in Hypersonic Airbreathing Propulsion System

Advanced airbreathing propulsion systems used in Mach 4-6 mission scenarios, usually involve turbo-ramjet configurations. As the engines transition from turbojet to ramjet, there is an operational envelope where both engines operate simultaneously. In the first phase of our study, an over/under nozzle configuration was analyzed. The two plumes from the turbojet and ramjet interact at the end of a common 2-D cowl, where they both reach an approximate Mach 3.0 condition and then jointly expand to Mach 3.6 at the common nozzle exit plane. For the problem analyzed, the turbojet engine operates at a higher nozzle pressure ratio than the ramjet, causes the turbojet plume overpowers the ramjet plume, deflecting it approximately 12 degrees downward and in turn the turbojet plume is deflected 6 degrees upward. In the process, shocks were formed at the deflections and a shear layer formed at the confluence of the two jets. This particular case was experimentally tested and the data were used to compare with a computational fluid dynamics (CFD) study using the PARC2D code. The CFD results were in good agreement with both static pressure distributions on the cowl separator and on nozzle walls. The thrust coefficients were also in reasonable agreement. In addition, inviscid relationships were developed around the confluence point, where the two exhaust jets meet, and these results compared favorably with the CFD results. In the second phase of our study, a 3-D CFD solution was generated to compare with the 2-D solution. The major difference between the 2-D and 3-D solutions was the interaction of the shock waves, generated by the plume interactions, on the sidewall. When a shock wave interacts with a sidewall and sidewall boundary layer, it is called a glancing shock sidewall interaction. These interactions entrain boundary layer flow down the shockline into a vortical flow pattern. The 3-D plots show the streamlines being entrained down the shockline. The pressure of the flow also decreases slightly as the sidewall is approached. Other difference between the 2-D and 3-D solutions were a lowering of the nozzle thrust coefficient value from 0.9850 (2-D) to 0.9807 (3-D), where the experimental value was 0.9790. In the third phase of our study, a different turbo-ramjet configuration was analyzed. The confluence of a supersonic turbojet and a subsonic ramjet in the turbine based combined-cycle (TBCC) propulsion system was studied by a 2-D CFD code. In the analysis, Mach 1.4 primary turbojet was mixed with the subsonic ramjet secondary flow in an ejector mode operation. Reasonable agreements were obtained with the supplied I-D TBCC solutions. For low downstream backpressure, the Fabri choke condition (Break-Point condition) was observed in the secondary flow within mixing zone. For sufficient high downstream backpressure, the Fabri choke no longer exist, the ramjet flow was reduced and the ejector flow became backpressure dependent. Highly non-uniform flow at ejector exit were observed, indicated that for smooth downstream combustion, the mixing of the two streams probably required some physical devices.

Chang, Ing↗

The Prediction of Ducted Fan Engine Noise Via a Boundary Integral Equation Method

A computationally efficient Boundary Integral Equation Method (BIEM) for the prediction of ducted fan engine noise is presented. The key features of the BIEM are its versatility and the ability to compute rapidly any portion of the sound field without the need to compute the entire field. Governing equations for the BIEM are based on the assumptions that all acoustic processes are linear, generate spinning modes, and occur in a uniform flow field. An exterior boundary value problem (BVP) is defined that describes the scattering of incident sound by an engine duct with arbitrary profile. Boundary conditions on the duct walls are derived that allow for passive noise control treatment. The BVP is recast as a system of hypersingular boundary integral equations for the unknown duct surface quantities. BIEM solution methodology is demonstrated for the scattering of incident sound by a thin cylindrical duct with hard walls. Numerical studies are conducted for various engine parameters and continuous portions of the total pressure field are computed. Radiation and duct propagation results obtained are in agreement with the classical results of spinning mode theory for infinite ducts.

Boundary integral equation↗