Search NASA⌕ Search

SEARCH · Search NASA

Results for “URANIUM ISOTOPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Neutron Coincidence Measurements of Uranium-233 Oxide

Renewed international interest in thorium-fueled advanced reactors has challenged the safeguards community to address future proliferation concerns. Thorium-based technology presents many benefits but does not eliminate the proliferation risks associated with producing and processing fissile material. A byproduct of thorium-fueled reactors is uranium-233, which is classified as a direct-use material. As a result, the development of new or improved methods to characterize and measure materials containing 233U must mirror the pace of development of reactors and facilities that produce such material. Research is underway to assess, develop, and test approaches for safeguarding nuclear materials within the thorium fuel cycle. Neutron signatures from the nondestructive assay (NDA) of materials containing 233U are being quantified to inform the potential characterization of these materials. Using a traditional neutron coincidence counter and a series of well-documented 233U oxide samples, initial measurements have been made to assess the feasibility of 233U characterization and discrimination from other uranium isotopes, primarily 235U, using a combination of measurement techniques and analysis methods. Data acquisition is performed in list mode, allowing for a variety of analyses to be performed on the raw data that is not available using traditional shift register technology. Measurements were performed in passive and active configurations to quantify the strength of signal and to validate simulations in support of this work. This paper presents and discusses the results of the initial measurements of 233U oxide performed at Oak Ridge National Laboratory.

Lockhart, Madeline↗

Advancing Elemental and Isotopic Analysis of Uranium Mineral Inclusions: Rapid Screening via Laser-Induced Breakdown Spectroscopy and High-Resolution Laser Ablation-ICP-MS Mapping

The work presented herein employs two laser-based analytical techniques (laser-induced breakdown spectroscopy (LIBS) and laser ablation – inductively coupled plasma – mass spectrometry (LA-ICP-MS)) to spatially determine the elemental and isotopic composition of uranium bearing minerals. Uniquely, this work leverages the high-speed applicability of LIBS to “screen” the sample(s) for their elemental constituents. After determining the location of the uranium inclusions (via LIBS), high-resolution LA-ICP-MS was employed to further characterize the inclusions. The high-resolution (sub-µm) capabilities of LA-ICP-MS were able to extract important information from the uranium minerals including discerning its chemical form (e.g., finchite from carnotite, Sr- and K-bearing uranyl vanadates, respectively) as well as their 235 U/ 238 U isotopic composition. This approach, LIBS followed by LA-ICP-MS, significantly reduces the analysis time (~95 %) in comparison to employing a LA-ICP-MS only approach. Furthermore, this work presented a novel approach to analyzing inclusions via a particle/inclusion analysis tool which is commercially available within the iolite 4 software. This tool allowed for a more accurate characterization of the isotopic distribution of the inclusions, as well as allowing for rapid sizing of the inclusions. Finally, this analytical approach could readily be applied to other sample types in which the target species (e.g., µm-sized inclusions) are embedded in complex matrices (e.g., cm-sized samples).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Refining Methods to Determine the Isotopic Composition of Uranium Particles by Laser Ablation MC-ICP-MS

We report on efforts to mitigate the generation of isotopic anomalies during the ablation of micrometer-sized uranium oxide particles and analysis by MC-ICP-MS. The results of testing on particles of U200 indicate that laser fluence and frequency can affect isotopic data produced by laser ablation, but no settings were tested that could eradicate the signal spiking effect and generation of anomalous isotopic data for 234U/238U and 236U/238U. These anomalies are more frequent in samples with higher 235U enrichments, which is expected given their higher abundances of 234U and 236U. Of the standards tested here, only U005-A was anomaly-free. Efforts to compare the laser traces for particles with normal and anomalous isotopic compositions showed subtle differences in the behavior of the 234U/238U and 236U/238U ratios. However, it would be challenging to identify anomalous data points from a population of unknowns using this distinction, i.e., this is unlikely to be diagnostic. Thus, using current analytical hardware, we cannot eradicate the signal spiking phenomenon and cannot unambiguously identify isotopic anomalies from laser ablation traces. Ultimately, laser ablation ICP-MS would either require dramatic improvement to the ablation process and generation of more homogenous aerosols and/or improvements to detector electronics to identify and correct for the spiking phenomenon. Even if the reliability of the technique could be improved, a broader question to address is whether current data quality is of a high enough standard for laser ablation MC-ICP-MS to be used as a complementary technique to LG-SIMS for Safeguards.

organic↗

Recovery of stable isotope taggants along a wet production pathway of uranium dioxide

Stable isotope taggants added to nuclear materials could be utilized as diagnostic nuclear forensics signatures; however, intentionally adding taggants is a relatively new and untested concept with respect to the nuclear fuel cycle. Here, in this study, we added trace amounts of stable Mo and W isotope taggants to starting materials used to synthesize UO 2 along a wet synthesis pathway. Successful incorporation and recovery of the Mo and W taggants was achieved in the UO 2 product and all its precursors. This study demonstrates the efficacy of stable isotope tagging along a wet UO 2 production pathway.

Nuclear forensics↗

Samarium isotope compositions of uranium ore concentrates: A novel nuclear forensic signature

Uranium ore is mined and milled to produce uranium ore concentrate (UOC), a regulated product of the nuclear fuel cycle. Additionally, diversion of UOC from the fuel cycle into possible weapons production is a key concern in global nonproliferation efforts. As such, the ability to trace the origin of seized nuclear materials is imperative to law enforcement efforts. Although isotopic signatures of UOCs have proven fruitful to pinpoint sample provenance, new isotopic signatures are needed because most existing isotopic signatures are not indicative of the original ore body from which the U is derived. In this work, we developed a new method to separate samarium (Sm) from a U-rich sample matrix and report the first Sm isotope compositions of 32 UOCs derived from a variety of worldwide uranium mines. Relative to terrestrial standards, approximately half the UOCs have resolved and anticorrelated 149 Sm- 150 Sm isotope compositions, consistent with the capture of thermal neutrons by 149 Sm in the ore body. The UOCs with anomalous Sm isotope compositions tend to derive from older (~>1.5Ga) and higher-grade ore bodies, although other factors, such as the presence of neutron moderators like water, also play a role. Nonetheless, the Sm isotope compositions of UOCs directly reflects the neutron fluence over the history of the original ore body and can be used to discern different geologic conditions associated with that ore body. Overall, this work demonstrates the potential use of Sm isotopes as a novel nuclear forensics signature for origin assessment of UOCs.

58 GEOSCIENCES↗

Direct isotopic analysis of solid uranium particulates on cotton swipes by microextraction-ICP-MS

Direct isotope ratio analysis of solid uranium particulates on cotton swipes was achieved using a solution-based microextraction technique, coupled to a quadrupole inductively coupled plasma - mass spectrometer (ICP-MS). This microextraction-ICP-MS methodology provides rapid isotopic analysis which could be applicable to nuclear safeguards measurements. Particulates of uranyl nitrate hexahydrate (UO 2 (NO 3 ) 2 ·6H 2 O) and uranyl fluoride (UO 2 F 2 ) ranging from 6 μm to 40 μm in length were transferred to cotton swipes with a particle manipulator. The microextraction probe then delivers a 5% nitric acid (HNO3) solvent onto the swipe surface to extract the uranium species. The extracted sample is then delivered to the ICP-MS for isotopic determination. The majority of uranium signal (~99% and ~94% for UO2(NO3)2·6H2O and UO 2 F 2 , respectively) was detected in the first 15 s extraction, while subsequent extractions on the same location had low or no U signal, suggesting near complete removal of the solid uranium compounds from the swipe surface. Ten samples (for each of the uranium compounds), were analyzed for their isotopic composition. For UO 2 (NO 3 ) 2 ·6H 2 O, the determined isotope ratios resulted in a % relative difference (% RD) from the referenced isotope ratios of 0.97, 1.0, and 7.3% for 234 U/ 238 U, 235 U/ 238 U, and 236 U/ 238 U, respectively. The % RD of the UO 2 F 2 isotope ratios were 1.9 and 0.60% for 234 U/ 238 U and 235 U/ 238 U, respectively. The preliminary limits of detection were determined to be 0.002, 0.4, and 60 pg for 234 U, 235 U and 238 U, respectively This work demonstrates that microextraction ICP-MS is a rapid and sensitive method that could directly determine uranium isotope ratios of UO 2 (NO 3 ) 2 ·6H 2 O and UO 2 F 2 particulates on cotton swipes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single particle – MC-ICP-MS for isotopic analysis of uranium particles

Single particle – multi-collector – inductively coupled plasma – mass spectrometry (SP-MC-ICP-MS) was employed to measure a suspension of 1 µm U3O8 particles (∼1.3 pg total U/particle) to determine their individual isotopic compositions of 234U/238U, 235U/238U, and 236U/238U. The effects of different detector combinations for 235U and 238U, including secondary electron multipliers (SEM) and Faraday detectors (1011 and 1013 Ω amplifiers), were explored for accuracy and precision optimization on the observed 235U/238U. The minor isotopic ratios (i.e., 234U/238U and 236U/238U) were analyzed such that the 234U and 236U were monitored on SEM detectors and the 238U was monitored on a Faraday (1011 Ω) detector. Various integration times (5, 10, 25, and 50 ms) were investigated in all detector configurations to gain a better understanding of their impact on sensitivity, accuracy, and precision. For 235U/238U ratios of 1 µm U3O8 particles, a dual Faraday detector measurement with 1011 Ω was the optimal choice; measurement of 1021 particles yielded an average 235U/238U ratio of 0.00170 (14), a −1.8% relative difference (% RD) from the reference value. The minor isotopic compositions were determined to be 0.0000070 (14) and 0.0000758 (48) for the 234U/238U and 236U/238U, respectively. These measurements correspond to <8% and <1% RD from their reference value for the 234U/238U and 236U/238U, respectively. SP-MC-ICP-MS was also able to provide insight into measurement sensitivity. In these individual particles, merely 15 and 165 atto-grams (ag) of 234U and 236U were present (calculated). Initial limits of detection for SP-MC-ICP-MS were determined to be ∼1.0 ag (when measured via SEM detectors). This valuable approach is applicable to areas including nuclear forensics, nuclear safeguards, and geochemical analysis, which require high-precision measurements of uranium within micron-sized particles.

Manard, Benjamin [ORNL] (ORCID:0000000207400627)↗

A new HALEU isotopic certified reference material

Candidate certified reference material (CRM) U196 was prepared by gravimetrically mixing and dissolving NNSA NRMP CRM 112-A (natural uranium metal) and CRM 116-A (highly enriched 93.2% 235 U metal) to achieve a high-assay low-enriched uranium (HALEU) isotopic abundance reference material. CRM U196 will be certified for the 233 U/ 238 U, 234 U/ 238 U, 235 U/ 238 U, and 236 U/ 238 U ratios. Gravimetrically determined uranium isotope amount ratios and values derived from the isotope data were calculated from the buoyancy corrected mass data and from certified values for the metal CRMs used to create the solution. The 235 U isotope amount fraction (·100) and expanded uncertainty is 19.5846 ± 0.0028. For attribute verification, total evaporation and modified total evaporation isotope ratio measurements were performed. In conclusion, the reference material is to be distributed as a unit containing 5 mg uranium as dry uranyl nitrate.

High-assay low-enriched uranium↗

Interlaboratory comparison of secondary ion mass spectrometry analysis results from the 7th international technical nuclear forensics working group collaborative material exercise

A review and interlaboratory comparison of secondary ion mass spectrometry (SIMS) data obtained by laboratories participating in the International Technical Nuclear Forensics Working Group (ITWG) 7th Collaborative Material Exercise (CMX-7) has been conducted. The analyzed materials were two uranium compounds in powder form and two pieces of uranium metal. The instruments used in this comparison were a small-geometry (SG) SIMS, CAMECA IMS 7f from the Research Centre Rez, and a large-geometry (LG) SIMS, CAMECA IMS 1280 from Los Alamos National Laboratory. Despite the differences in instruments and analytical procedures, e.g., sample preparation, SIMS setups, and data post-processing, there was good agreement for the 234 U/ 238 U, 235 U/ 238 U, and 236 U/ 238 U ratios in the analyzed materials. The main difference was in the precision, which was, as expected, higher for the LG-SIMS. In addition, a comparison between the laboratories was also made for the image processing algorithms applied to raw data acquired in automated particle measurement (APM) mode. In conclusion, the result of this comparison has led to identification of best practices for setting up parameters of the APM software.

and nuclear chemistry↗

High Flux Isotope Reactor Low-Enriched Uranium Low Density Silicide Fuel Design Parameters

High Flux Isotope Reactor (HFIR) highly enriched uranium (HEU) to low-enriched uranium (LEU) conversion activities are ongoing as part of the Department of Energy (DOE) National Nuclear Security Administration (NNSA)’s nuclear nonproliferation mission. Design activities studying the conversion of HFIR from HEU to LEU fuel explored different fuel design features and shapes with a low density uranium-silicide dispersion (U 3 Si 2 -Al) fuel, which has a uranium density of 4.8 gU/cm 3 . The goal of these studies is to generate several HFIR LEU fuel designs of varying fuel fabrication complexity that meet the current HEU performance metrics and safety requirements. The documented designs will serve as references for fuel fabrication and qualification activities. Recent advancements in modeling and simulation tools enable quick prototyping of fuel designs. Shift, a Monte Carlo neutron transport and depletion tool optimized for high-performance computing (HPC) architectures, is used for efficient fuel cycle and performance metrics calculations. The HFIR Steady State Heat Transfer Code (HSSHTC) is used to vet the thermal safety margin. Also, a new automation tool that connects all fuel design analysis steps, named Python HFIR Analysis and Measurement Engine (PHAME), has been developed to expedite the design study in an efficient and reproducible manner. Leveraging these tools, several candidate fuel designs were selected for varying fabrication complexity. This report provides design feature details for four selected HFIR LEU low density U 3 Si 2 -Al fuel designs and their corresponding performance and safety metrics. Nominal, best-estimate design parameters and irradiation conditions, including fission rate densities, power densities, heat fluxes, and cumulative fission densities are provided for candidate fuel designs relevant to framing irradiation experiments to support fuel qualification efforts. Simulations show that the low density U 3 Si 2 -Al, with design features to enhance safety, can meet HEU core performance metrics and safety requirements if the reactor power is increased from 85 MW (HEU) to 95 MW (LEU) and if the active fuel length is increased from 50.80 cm (HEU) to 55.88 cm (LEU).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Challenges in correlating oxygen stable isotope ratios of hydrates on uranium ore concentrates to process waters

Exchange of oxygen stable isotopes (δ 18 O values) between precipitation waters and uranium oxides is governed by thermodynamics or kinetics. It has been assumed that meteoric waters can be related to precipitation waters in uranium ore concentrates and their calcination and reduced uranium oxide products. With this assumption, the δ 18 O values of uranium materials could provide forensic signatures that identify the production history and geolocation of nuclear materials. To further exploit the potential of δ 18 O values in nuclear material analysis, this study examines the oxygen stable isotope exchange in two UOCs, magnesium diuranate (MDU) and sodium diuranate (SDU). MDU and SDU were synthesized from solutions of uranyl nitrate hexahydrate using precipitation waters with unique oxygen isotope compositions. The structures of the MDU and SDU were analyzed using powder X-ray diffraction (p-XRD) and thermal mass loss curves, while the δ 18 O values of waters generated during thermal decomposition were analyzed using a thermogravimetric analyzer coupled to an isotope ratio infrared spectrometer (TGA-IRIS). By p-XRD, the MDU was uniform and amorphous across all syntheses with residual crystalline material incorporated as a minor component. Combined with the TGA results, all of the MDU is likely amorphous MgU 2 O 7 ·3H 2 O with MgO impurities present throughout. In contrast, the SDU synthesis resulted in multiple phases with many samples exhibiting crystalline phases including a combination of Na(UO 2 ) 4 O 2 (OH) 5 ·5H 2 O and Na 2 (UO2) 6 O 4 (OH) 6 ·8H 2 O with a Na 2 U 2 O 7 minor phase. A small fraction of the SDU samples were amorphous with no crystalline XRD peaks observed. Mass loss curves of the SDU samples revealed that the amorphous samples contained inclusions of similar crystalline phases compared to the crystalline materials. The uniformity of the MDU samples enabled highly reproducible measurements of δ 18 O values of the water vapor yielded for two dehydration events at 170 °C and 500 °C. In contrast, the multiphase composition of the SDU samples resulted in poor reproducibility in δ 18 O values. In conclusion, neither system revealed any correlation between the δ 18 O values of precipitation water, and the waters released during dehydration of the UOCs.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Automated reactor physics analysis framework of High Flux Isotope Reactor low-enriched uranium silicide dispersion fuel designs

The High Flux Isotope Reactor (HFIR) is a versatile research reactor that provides one of the highest steady-state neutron fluxes of any reactor in the world. The HFIR reactor physics team investigated the conversion of the current 93 wt% highly enriched uranium U 3 O 8 -Al dispersion fuel to a 19.75% low-enriched uranium (LEU) U 3 Si 2 -Al dispersion fuel. The team continuously develops a Python module to streamline the analysis steps required for an LEU core design to ensure reproducible and agile design iteration. The Python module automates the data processing between analysis steps and automates the input perturbation for branch calculations and design changes. The automated framework has proven to significantly increase the efficiency and reproducibility of the reactor physics team to design High Flux Isotope Reactor (HFIR) LEU cores and thoroughly analyze performance metrics, safety metrics, and thermal safety margins. Consequently, the team can now respond rapidly to fuel fabrication engineer and thermal-hydraulic-structural analyst requests. Numerous combinations of LEU fuel designs are explored, of which two LEU fuel designs are presented here in this paper: a low density silicide design, and a high-density silicide design. Results show that both designs meet or exceed safety and performance metrics with exception for minor differences caused by the hardened spectrum from LEU.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

New reference materials for trace-levels of actinide elements in plutonium

In this report two plutonium oxides were prepared as unique reference materials for measurement of actinide elements present as trace constituents. Each reference material unit is approximately 200 mg of PuO 2 powder in a quartz glass bottle. Characterized attributes of the oxides included mass fractions of plutonium, americium, neptunium, and uranium. Isotope-amount ratios were also determined for plutonium and uranium, but neptunium and americium were observed to be monoisotopic 237 Np and 241 Am. Measurements for characterization and verification of the attributes show that plutonium and trace actinides are homogeneous with the exception of limited heterogeneity for uranium, primarily observed for the 238 U isotope. Model purification ages calculated from measured americium and uranium attribute values are consistent with material histories and indicate that these impurities are predominantly due to the decay of plutonium isotopes.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Characterization of actinide abundances and isotopic compositions by HR-ICP-MS. Part 2: Results from actinide doping studies

Previously, we presented actinide isotopic and elemental data from fallout melt glass that was measured using high-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). Direct comparison between these measurements and ‘gold standard’ data obtained by multi-collector ICP-MS showed broad overlap, indicating that HR-ICP-MS is a potentially valuable technique for producing actinide elemental and isotopic data on a relatively rapid timescale. To test the usefulness of this technique further, we doped varying amounts of uranium certified reference materials (CRMs) into a rhyolitic rock standard to establish the effects of uranium concentration and isotopic composition on the accuracy of uranium isotopic analyses by HR-ICP-MS. This also enabled us to quantify peak tailing effects from 238 U on the measurement of 239 Pu and 237 Np, which in turn allows us to constrain correction factors based on measured 237 Np/ 238 U and 239 Pu/ 238 U ratios. A second doping study involved the addition of a mixed actinide standard into three samples with different matrix compositions (termed soil, city, and seawater) to assess whether sample chemistry affects the accuracy and precision of these analyses. Results suggest that this is not the case. Systematic offsets were not observed in elemental or isotopic data derived from the three matrix samples. Results indicate that useful actinide isotopic data can be obtained from whole rock solutions by HR-ICP-MS. Our findings also have implications for solid sampling techniques such as laser ablation ICP-MS, which do not require sample dissolution.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗