Search NASA⌕ Search

SEARCH · Search NASA

Results for “USb”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Longitudinal stability and control characteristics of the Quiet Short-Haul Research Aircraft (QSRA)

Flight experiments were conducted to evaluate various aerodynamic characteristics of the Quiet Short-Haul Research Aircraft (QSRA), an experimental aircraft that makes use of the upper-surface blown (USB) powered-lift concept. Time-history records from maneuvers performed with the aircraft in landing-approach and take-off configurations (with its stability augmentation system disengaged) were analyzed to obtain longitudinal stability and control derivatives and performance characteristics. The experiments included measuring the aircraft responses to variations in the deflection of direct-lift control spoilers and to thrust variations as well as to elevator inputs. The majority of the results are given for the aircraft in a landing configuration with the USB flaps at 50 degrees. For this configuration, if the static longitudinal stability is defined as the variation of the pitching-moment coefficient with the lift coefficient at a constant thrust coefficient, this stability decreases significantly with increasing angle of attack above 9 degrees. For this configuration, at small and negative angles of attack and high levels of thrust, the elevators and the horizontal stabilizer lost effectiveness owing to incipent stalling, but this occurred only during unsteady maneuvers and for brief time intervals.

Stephenson, Jack D.↗

Lateral-directional stability and control characteristics of the Quiet Short-Haul Research Aircraft (QSRA)

The results are presented of flight experiments to determine the lateral-directional stability and control characteristics of the Quiet Short-Haul Research Aircraft (QSRA), an experimental aircraft designed to furnish information on various aerodynamic characteristics of a transport type of airplane that makes use of the upper-surface blown (USB) flap technology to achieve short takeoff and landing (STOL) performance. The flight program designed to acquire the data consisted of maneuvers produced by rudder and control-wheel inputs with the airplane in several configurations that had been proposed for landing approach and takeoff operation. The normal stability augmentation system was not engaged during these maneuvers. Time-history records from the maneuvers were analyzed with a parameter estimation procedure to extract lateral-directional stability and control derivatives. For one aircraft configuration in which the USB flaps were deflected 50 deg, several maneuvers were performed to determine the effects of varying the average angle of attack, varying the thrust coefficient, and setting the airplane's upper surface spoilers at a 13 deg symmetrical bias angle . The effects on the lateral characteristics of deflecting the spoilers were rather small and generally favorable. The data indicate that for one test, conducted at low thrust (a thrust coefficient of 0.38), compared with results from tests at thrust coefficients of 0.77 and larger, there was a significant decrease in the lateral control effectiveness, in the yaw damping and in the directional derivative. The directional derivative was also decreased (by about 30 percent) when the average angle of attack of the test was increased from 3 to 16 deg.

Stephenson, Jack D.↗

High speed aerodynamics of upper surface blowing aircraft configurations

An experimental investigation of the high speed aerodynamics of Upper Surface Blowing (USB) aircraft configurations has been conducted to accurately define the magnitude and causes of the powered configuration cruise drag. A highly instrumented wind tunnel model of a realistic USB configuration was used which permitted parametric variations in the number and spanwise location of the nacelles and was powered with two turbofan engine simulators. The tests conducted in the Ames 14 Foot Transonic Wind Tunnel examined 10 different configurations at Mach numbers from 0.5 to 0.775, fan nozzle pressure ratios from 1.1 to 2.1 and angles of attack from -4 to 6 degrees. Measured force data is presented which indicates the cruise drag penalty associated with each configuration and surface pressure contour plots are used to illustrate the underlying flowfield physics. It was found that all of the tested configurations suffered from a severe drag penalty which increased with freestream Mach number, power setting and angle of attack and was associated with the presence of strong shocks and regions of separated flow in the wing/nacelle junction regions.

Birckelbaw, Larry D.↗

Magellan Post Launch Mission Operation Report

Magellan was successfully launched by the Space Shuttle Atlantis from the Kennedy Space Center at 2:47 p.m. EDT on May 4, 1989. The Inertial Upper Stage (IUS) booster and attached Magellan Spacecraft were successfully deployed from Atlantis on Rev. 5 as planned, at 06:14 hrs Mission Elapsed Time (MET). The two IUS propulsion burns which began at 07:14 hrs MET and were completed at 07:22 hrs MET, placed the Magellan Spacecraft almost perfectly on its preplanned trajectory to Venus. The IUS was jettisoned at 07:40 hrs MET and Magellan telemetry was immediately acquired by the Deep Space Network (DSN). A spacecraft trajectory correction maneuver was performed on May 21 and the spacecraft is in the planned standard cruise configuration with all systems operating nominally. An initial attempt was made to launch Atlantis on April 28, 1989, but the launch was scrubbed at T-31 sec due to a failure of the liquid hydrogen recirculation pump on Space Shuttle Main Engine #1. The countdown had proceeded smoothly until T-20 min when the Magellan radio receiver "locked-on" the MIL 71 Unified S-Band (USB) transmission as the transmitter power was increased fro 2 kw to 10 kw in support of the orbiter launch. During the planned hold at T-9 min, the USB was confirmed as the source of the receiver "lock" and Magellan's launch readiness was reaffirmed. In addition a five-minute extension of the T-9 hold occurred when a range safety computer went off-line, creating a loss of redundancy in the range safety computer network. Following resumption of the countdown, both the orbiter and Magellan flows proceeded smoothly until the launch was scrubbed at T-31 sec.

Source record↗

Remotely Accessible Testbed for Software Defined Radio Development

Previous development testbeds have assumed that the developer was physically present in front of the hardware being used. No provision for remote operation of basic functions (power on/off or reset) was made, because the developer/operator was sitting in front of the hardware, and could just push the button manually. In this innovation, a completely remotely accessible testbed has been created, with all diagnostic equipment and tools set up for remote access, and using standardized interfaces so that failed equipment can be quickly replaced. In this testbed, over 95% of the operating hours were used for testing without the developer being physically present. The testbed includes a pair of personal computers, one running Linux and one running Windows. A variety of peripherals is connected via Ethernet and USB (universal serial bus) interfaces. A private internal Ethernet is used to connect to test instruments and other devices, so that the sole connection to the outside world is via the two PCs. An important design consideration was that all of the instruments and interfaces used stable, long-lived industry standards, such as Ethernet, USB, and GPIB (general purpose interface bus). There are no plug-in cards for the two PCs, so there are no problems with finding replacement computers with matching interfaces, device drivers, and installation. The only thing unique to the two PCs is the locally developed software, which is not specific to computer or operating system version. If a device (including one of the computers) were to fail or become unavailable (e.g., a test instrument needed to be recalibrated), replacing it is a straightforward process with a standard, off-the-shelf device.

Lux, James P.↗

Optical Multi-Gas Monitor Technology Demonstration on the International Space Station

There are a variety of both portable and fixed gas monitors onboard the International Space Station (ISS). Devices range from rack-mounted mass spectrometers to hand-held electrochemical sensors. An optical Multi-Gas Monitor has been developed as an ISS Technology Demonstration to evaluate long-term continuous measurement of 4 gases. Based on tunable diode laser spectroscopy, this technology offers unprecedented selectivity, concentration range, precision, and calibration stability. The monitor utilizes the combination of high performance laser absorption spectroscopy with a rugged optical path length enhancement cell that is nearly impossible to misalign. The enhancement cell serves simultaneously as the measurement sampling cell for multiple laser channels operating within a common measurement volume. Four laser diode based detection channels allow quantitative determination of ISS cabin concentrations of water vapor (humidity), carbon dioxide, ammonia and oxygen. Each channel utilizes a separate vertical cavity surface emitting laser (VCSEL) at a different wavelength. In addition to measuring major air constituents in their relevant ranges, the multiple gas monitor provides real time quantitative gaseous ammonia measurements between 5 and 20,000 parts-per-million (ppm). A small ventilation fan draws air with no pumps or valves into the enclosure in which analysis occurs. Power draw is only about 3 W from USB sources when installed in Nanoracks or when connected to 28V source from any EXPRESS rack interface. Internal battery power can run the sensor for over 20 hours during portable operation. The sensor is controlled digitally with an FPGA/microcontroller architecture that stores data internally while displaying running average measurements on an LCD screen and interfacing with the rack or laptop via USB. Design, construction and certification of the Multi-Gas Monitor were a joint effort between Vista Photonics, Nanoracks and NASA-Johnson Space Center (JSC). Vista Photonics developed the core technology and built the sensor. Nanoracks designed, constructed the enclosure, interfaces, and battery power management circuitry, integrated all subsystems into the enclosure, and then managed the certification tests, documentation and manifesting. The unit was calibrated in the JSC Toxicology Laboratory. The Multi-Gas Monitor is manifested to fly as a technology demonstration to the ISS in November 2013 and will operate for at least 6 months with data sent to the ground for evaluation. The primary goal is to demonstrate long term interference free operation in the real spacecraft environment.

Pilgrim, Jeffrey S.↗

Sequencing to Station in 12 Months (Targeting Orbital 5 Launch, March 30th)

The Biomolecule Sequencer is a Commercial Off-The-Shelf device developed by Oxford Nanopore Technologies and implements a method of DNA sequencing unlike any other current sequencers. The device measures changes in electrical current through a nanopore depending on the sequence of the DNA strand that is passing through it. Since the technology is built on nanometer-scale ion pores, the hardware itself is exceptionally small (3 x 1 x 58 inches), lightweight (less than 120 grams with USB cable), and powered only by a USB connection. The sequencing device is permanent, while the flow cells, to which the samples are added, are periodically replaced. The goal of our upcoming technology demonstration on ISS is to provide evidence that DNA sequencing in space is possible, which holds the exciting potential to enable the identification of microorganisms, monitor changes in microbes and humans in response to spaceflight, and possibly aid in the detection of DNA-based life elsewhere in the universe.

microorganisms↗

3D Scanning System to Assess Gravity-Dependent Body Shape Changes

The human body shows unique morphological changes when exposed to different gravity conditions, including muscle atrophy, fluid shift, and spinal elongation. Such changes need to be incorporated for human-system integration in the vehicle habitat, garment, and spacesuit designs, as inaccurate body measurements can result in suboptimal crew protection that can potentially decrease injury tolerance. However, measurement tools have not been available for accurate assessments of body shape changes. This work aimed to develop a prototype 3-D body scanning system with the configuration and performance optimized for in-flight crewmember body scanning. A scan hardware system was developed using Intel RealSense commercial off-the-shelf 3D sensors. The sensor parameters were iteratively optimized and tested to obtain the performance level needed for body scanning. A scan booth structure was fabricated, with the overall size 4 x 4 x 8 feet. The specific number of sensors and mounting positions were determined by iterative simulations, which indicated that 16 cameras can capture 94% and 96% of body surface area from the 1st percentile female and 99th percentile male crew population subject. The mounted sensors were linked through a mix of USB-C and USB-3 cables and operated for data acquisition from a Linux laptop computer. A software prototype was developed using Python and Tkinter graphical user interface toolkit. A calibration procedure was also built using a panel of QR codes. A computer vision tool detected and decoded the unique ID and pattern locations of the QR codes. The calibration information determined the position and orientation of the 3D sensors with respect to each other. The scanner performance was assessed using a set of 3D printed custom manikins. The manikin size and shape were derived from the previous ISS study, which measured the crewmembers’ anthropometry changes across the different flight phases. The average anthropometric measurements at the pre-flight and flight day 15 were sampled and projected onto the 1st percentile female and 99th percentile male body shapes. Another pair of manikins were also 3D printed to simulate the neutral body posture, estimated from ISS microgravity environments. A preliminary analysis assessed the performance of the newly developed scanner against the reference scanner, which has been used at the NASA JSC for crew and test subject anthropometry. Although the new scanner data showed several artifacts and missing geometries in the occluded body areas such as armpits and crotch, overall shape matched with the reference scan. When the manikin surface coordinates were compared, a root mean square error of 1.3 cm was observed from the manikin torso segment. Linear measurements including the stature, knee height and circumference measurements at the chest and calf showed differences from the reference scan measurements, ranging between 0.3 and 0.9 cm. Overall, this work demonstrated a development framework for an in-flight scanner with design and operation optimized for crewmember body scanning. Further improvement can potentially provide previously unavailable anthropometric data from different gravitational environments, including 0-g, 1/6-g, and 1-g. Such data can improve suit fit, habitat design, exercise efficacy quantification and sizing of orthostatic intolerance garments.

K H Kim↗

RASDR: Benchtop Demonstration of SDR for Radio Astronomy

The Society of Amateur Radio Astronomers (SARA) members present the benchtop version of RASDR, a Software Defined Radio (SDR) that is optimized for Radio Astronomy. RASDR has the potential to be a common digital receiver interface useful to many SARA members. This document describes the RASDR 0.0 , which provides digitized radio data to a backend computer through a USB 2.0 interface. A primary component of RASDR is the Lime Microsystems Femtocell chip which tunes from a 0.4-4 GHz center frequency with several selectable bandwidths from 0.75 MHz to 14 MHz. A second component is a board with a Complex Programmable Logic Device (CPLD) chip that connects to the Femtocell and provides two USB connections to the backend computer. A third component is an analog balanced mixer up conversion section. Together these three components enable RASDR to tune from 0.015 MHz thru 3.8GHz of the radio frequency (RF) spectrum. We will demonstrate and discuss capabilities of the breadboard system and SARA members will be able to operate the unit hands-on throughout the workshop.

astronomy↗

Gemini Scout Control Software

The Gemini Scout Control Software consists of two Windows applications that allow the Gemini Scout vehicle to be controlled by an operator. The Embedded application runs on the vehicle's Gemini Scout Control Software onboard computer and controls the vehicle's various motors and sensors. This application reports the vehicle's status and receives vehicle commands overthe local-area-network. The Embedded applicationalso allows the user to control the vehicle using a USB game-pad connected directly to the vehicle. The Operator Control Unit (OCU) application runs on an external PC and communicates with the vehicle via an Ethernet connection. The OCU application sends commands to and receives data from the Embedded application running on the vehicle. The OCU application also communicates directly with the digital video encoders and radios in order to display video from the vehicle's cameras and the status of the radio link. The OCU application has a graphical user interface (GUI) that displays the vehicle's status and allows the user to change various vehicle settings. Finally, the OCU application receives input from a USB game-pad connected to the PC in order to control the vehicle's functions.

Clinton Hobart, Justin Garretson↗

Confined Space Imager (CSI) Software

The software provides real-time image capture, enhancement, and display, and sensor control for the Confined Space Imager (CSI) sensor system The software captures images over a Cameralink connection and provides the following image enhancements: camera pixel to pixel non-uniformity correction, optical distortion correction, image registration and averaging, and illumination non-uniformity correction. The software communicates with the custom CSI hardware over USB to control sensor parameters and is capable of saving enhanced sensor images to an external USB drive. The software provides sensor control, image capture, enhancement, and display for the CSI sensor system. It is designed to work with the custom hardware.

Karelilz, David↗

An “Off-the-Shelf” System for Intraprocedural Electrical Current Evaluation and Monitoring of Irreversible Electroporation Therapy

IntroductionIrreversible electroporation (IRE) ablation uses a series of brief electric pulses to create nanoscale defects in cell membranes, killing the cells. It has shown promise in numerous soft-tissue tumor applications. Larger voltages between electrodes will increase ablation volume, but exceeding electrical limits may risk damage to the patient, cause ineffective therapy delivery, or require generator restart. Monitoring electrical current for these conditions in real-time enables managing these risks. This capacity is not presently available in clinical IRE generators.MethodsWe describe a system using a Tektronix TCP305 AC/DC Current Probe connected to a TCPA300 AC/DC Current Probe Amplifier, which is read on a computer using a Protek DSO-2090 USB computer-interfacing oscilloscope. Accuracy of the system was tested with a resistor circuit and by comparing measured currents with final outputs from the NanoKnife clinical electroporation pulse generator.ResultsAccuracy of measured currents was 1.64 ± 2.4 % relative to calculations for the resistor circuit and averaged 0.371 ± 0.977 % deviation from the NanoKnife. During clinical pulse delivery, the system offers real-time evaluation of IRE procedure progress and enables a number of methods for identifying approaching issues from electrical behavior of therapy delivery, facilitating protocol changes before encountering therapy delivery issues.ConclusionsThis system can monitor electrical currents in real-time without altering the electric pulses or modifying the pulse generator. This facilitates delivering electric pulse protocols that remain within the optimal range of electrical currents—sufficient strength for clinically relevant ablation volumes, without the risk of exceeding safe electric currents or causing inadequate ablation.

60 APPLIED LIFE SCIENCES↗

Low correlation between household carbon monoxide and particulate matter concentrations from biomass-related pollution in three resource-poor settings

Household air pollution from the burning of biomass fuels is recognized as the third greatest contributor to the global burden of disease. Incomplete combustion of biomass fuels releases a complex mixture of carbon monoxide (CO), particulate matter (PM) and other toxins into the household environment. Some investigators have used indoor CO concentrations as a reliable surrogate of indoor PM concentrations; however, the assumption that indoor CO concentration is a reasonable proxy of indoor PM concentration has been a subject of controversy. We sought to describe the relationship between indoor PM{sub 2.5} and CO concentrations in 128 households across three resource-poor settings in Peru, Nepal, and Kenya. We simultaneously collected minute-to-minute PM{sub 2.5} and CO concentrations within a meter of the open-fire stove for approximately 24 h using the EasyLog-USB-CO data logger (Lascar Electronics, Erie, PA) and the personal DataRAM-1000AN (Thermo Fisher Scientific Inc., Waltham, MA), respectively. We also collected information regarding household construction characteristics, and cooking practices of the primary cook. Average 24 h indoor PM{sub 2.5} and CO concentrations ranged between 615 and 1440 μg/m{sup 3}, and between 9.1 and 35.1 ppm, respectively. Minute-to-minute indoor PM{sub 2.5} concentrations were in a safe range (<25 μg/m{sup 3}) between 17% and 65% of the time, and exceeded 1000 μg/m{sup 3} between 8% and 21% of the time, whereas indoor CO concentrations were in a safe range (<7 ppm) between 46% and 79% of the time and exceeded 50 ppm between 4%, and 20% of the time. Overall correlations between indoor PM{sub 2.5} and CO concentrations were low to moderate (Spearman ρ between 0.59 and 0.83). There was also poor agreement and evidence of proportional bias between observed indoor PM{sub 2.5} concentrations vs. those estimated based on indoor CO concentrations, with greater discordance at lower concentrations. Our analysis does not support the notion that indoor CO concentration is a surrogate marker for indoor PM{sub 2.5} concentration across all settings. Both are important markers of household air pollution with different health and environmental implications and should therefore be independently measured. - Highlights: • We summarized indoor PM2.5 and CO concentrations across three resource-poor settings. • Overall correlations between indoor PM2.5 and CO were low to moderate. • Agreement between observed indoor PM2.5 vs. those estimated based on indoor CO was poor.

54 ENVIRONMENTAL SCIENCES↗

Multipurpose Compact Spectrometric Unit

A new standalone compact spectrometer was developed. The device consists of analog (peamplifier, amplifier) and digital parts. The digital part is based on the 160 MIPS Digital Signal Processor. It contains 20 Msps Flash-ADC, 1 MB RAM for spectra storage, 128 KB Flash/ROM for firmware storage, Real Time Clock and several voltage regulators providing the power for user peripherals (e.g. amplifier, temperature sensors, etc.). Spectrometer is connected with a notebook via high-speed USB 2.0 bus. The spectrometer is multipurpose device, which is planned to be used for measurements of Rn activities, energy of detected particles by CdTe pixel detector or for coincidence measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microcontroller based system for electrical breakdown time delay measurement in gas-filled devices

This paper presents realization of a digital embedded system for measuring electrical breakdown time delay. The proposed system consists of three major parts: dc voltage supply, analog subsystem, and a digital subsystem. Any dc power source with the range from 100 to 1000 V can be used in this application. The analog subsystem should provide fast and accurate voltage switching on the testing device as well as transform the signals that represent the voltage pulse on the device and the device breakdown into the form suitable for detection by a digital subsystem. The insulated gate bipolar transistor IRG4PH40KD driven by TC429 MOSFET driver is used for high voltage switching on the device. The aim of a digital subsystem is to detect the signals from the analog subsystem and to measure the elapsed time between their occurrences. Moreover, the digital subsystem controls various parameters that influence time delay and provides fast data storage for a large number of measured data. For this propose, we used the PIC18F4550 microcontroller with a full-speed compatible universal serial bus (USB) engine. Operation of this system is verified on different commercial and custom made gas devices with different structure and breakdown mechanisms. The electrical breakdown time delay measurements have been carried out as a function of several parameters, which dominantly influence electrical breakdown time delay. The obtained results have been verified using statistical methods, and they show good agreement with the theory. The proposed system shows good repeatability, sensitivity, and stability for measuring the electrical breakdown time delay.

36 MATERIALS SCIENCE↗

Demodulator electronics for laser vibrometry

One of the most important parts of a fiber-laser vibrometer is demodulation electronic section. The distortion, nonlinearity, offset and added noise of measured signal come from electronic circuits and they have direct influence on finale measuring results. Two main parameters of an investigated vibrating object: velocity V(t) and displacement s(t), influence of detected beat signals. They are: the Doppler frequency deviation f(t) and phase shift {phi}(t), respectively. Because of wide range of deviations it is difficult to use just one demodulator. That is the reason why we use three different types of demodulators. The first one is the IQ demodulator, which is the most sensitive one and its output is proportional to the displacement. Each IQ channel is sampled simultaneously by an analog to digital converter (ADC) integrated in a digital signal processor (DSP). The output signals from the two FM demodulators are proportional to the frequency deviation of heterodyne signals. They are sensitive directly to the velocity of the object. The main disadvantage of scattered light interferometry system is a ''speckle effect'', appearing in relatively large amplitude fluctuation of a heterodyne signal. To minimize ''speckle effect'' influence on quality of beat signals we applied the automatic gain control (AGC) system. Data acquisition, further signal processing (e.g. vibration frequency spectra) and presentation of results is realized by PC via USB interface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

10 ps resolution, 160 ns full scale range and less than 1.5% differential non-linearity time-to-digital converter module for high performance timing measurements

We present a compact high performance time-to-digital converter (TDC) module that provides 10 ps timing resolution, 160 ns dynamic range and a differential non-linearity better than 1.5% LSB{sub rms}. The TDC can be operated either as a general-purpose time-interval measurement device, when receiving external START and STOP pulses, or in photon-timing mode, when employing the on-chip SPAD (single photon avalanche diode) detector for detecting photons and time-tagging them. The instrument precision is 15 ps{sub rms} (i.e., 36 ps{sub FWHM}) and in photon timing mode it is still better than 70 ps{sub FWHM}. The USB link to the remote PC allows the easy setting of measurement parameters, the fast download of acquired data, and their visualization and storing via an user-friendly software interface. The module proves to be the best candidate for a wide variety of applications such as: fluorescence lifetime imaging, time-of-flight ranging measurements, time-resolved positron emission tomography, single-molecule spectroscopy, fluorescence correlation spectroscopy, diffuse optical tomography, optical time-domain reflectometry, quantum optics, etc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-throughput gated photon counter with two detection windows programmable down to 70 ps width

We present the design and characterization of a high-throughput gated photon counter able to count electrical pulses occurring within two well-defined and programmable detection windows. We extensively characterized and validated this instrument up to 100 Mcounts/s and with detection window width down to 70 ps. This instrument is suitable for many applications and proves to be a cost-effective and compact alternative to time-correlated single-photon counting equipment, thanks to its easy configurability, user-friendly interface, and fully adjustable settings via a Universal Serial Bus (USB) link to a remote computer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗