Time history of the magnetospheric cavity.

Cyclotron radius, magnetospheric boundary and Debye length scaling parameters for magnetospheric cavity arising from solar wind- induced geomagnetic storm and visibility of quasi- Van Allen belts

VAN ALLEN BELT↗

Ionization chamber

Ionization chamber developed for Mariner IV - components, calibration, operation, and performance in Van Allen belts and solar flare

CALIBRATION↗

PreMevE Update: Forecasting Ultra-Relativistic Electrons Inside Earth's Outer Radiation Belt

Energetic electrons inside Earth's Van Allen belts pose a major radiation threat to spaceborne electronics that often play vital roles in modern society. Ultra-relativistic electrons with energies greater than or equal to two megaelectron-volt (MeV) are of particular interest, and thus forecasting these ≥2 MeV electrons has a significant meaning to all space sectors. Here, we update the latest development of the predictive model for MeV electrons in the outer radiation belt. The new version, called PREdictive MEV Electron (PreMevE)-2E, forecasts ultra-relativistic electron flux distributions across the outer belt, with no need for in situ measurements of the trapped MeV electron population except at the geosynchronous orbit (GEO). Model inputs include precipitating electrons observed in low-Earthorbits by NOAA satellites, upstream solar wind speeds and densities from solar wind monitors, as well as ultra-relativistic electrons measured by one Los Alamos GEO satellite. We evaluated 32 supervised machine learning models that fall into four different classes of linear and neural network architectures, and successfully tested ensemble forecasting by using groups of top-performing models. All models are individually trained, validated, and tested by in situ electron data from NASA's Van Allen Probes mission. It is shown that the final ensemble model outperforms individual models at most L-shells, and this PreMevE-2E model can provide 25-h (~1-day) and 50-h (~2-day) forecasts with high mean performance efficiency and correlation values. Our results also suggest that this new model is dominated by nonlinear components at L-shells <~4 for ultra-relativistic electrons, different from the dominance of linear components for 1 MeV electrons as previously discovered.

79 ASTRONOMY AND ASTROPHYSICS↗

Trapped radiation experiment

Trapped radiation detector on Mariner IV space probe measurement of outer Van Allen belt - feasibility of detecting trapped radiation at Mars

MARINER IV SPACE PROBE↗

Decay rate of the second radiation belt

Variations in the Earth's trapped (Van Allen) belts produced by solar flare particle events are not well understood. Few observations of increases in particle populations have been reported. This is particularly true for effects in low Earth orbit, where manned spaceflights are conducted. This paper reports the existence of a second proton belt and it's subsequent decay as measured by a tissue-equivalent proportional counter and a particle spectrometer on five Space Shuttle flights covering an eighteen-month period. The creation of this second belt is attributed to the injection of particles from a solar particle event which occurred at 2246 UT, March 22, 1991. Comparisons with observations onboard the Russian Mir space station and other unmanned satellites are made. Shuttle measurements and data from other spacecraft are used to determine that the e-folding time of the peak of the second proton belt. It was ten months. Proton populations in the second belt returned to values of quiescent times within eighteen months. The increase in absorbed dose attributed to protons in the second belt was approximately 20%. Passive dosimeter measurements were in good agreement with this value.

Badhwar, G. D.↗

Experiment d-8, radiation in spacecraft gemini iv

Gemini IV measurements of radiation environment in inner Van Allen belt and South Atlantic anomaly region - ionizing and penetrating power of primary and secondary radiations

SPACECRAFT ENVIRONMENT↗

Polyvinyl Alcohol and Medium Density Polyethylene Composite Materials for Neutron Radiation Shielding

Manned spacecraft venturing beyond the Earth’s Van Allen Belts will be subjected to high levels of radiation from both energetic particles emanating from the sun and from galactic atomic events, such as supernovae. The metal shell of a spacecraft offers some protection from gamma radiation and high energy particles originating from both the sun and cosmic sources. The interaction of these high energy particles and radiation with the spacecraft hull create secondary radiation and neutrons, additional hazards for astronauts and electronic systems. Shielding of neutrons is the most challenging of the high energy radiation, since neutrons have zero charge and are least affected by electrical fields, magnetic fields, and atomic forces. Previous studies showed that polyethylene is an effective neutron shielding material, due to its high hydrogen content. High energy neutrons are slowed to thermal neutrons through multiple collisions with the hydrogen atoms, increasing the effectiveness of neutron capture by boron-10 atoms. This study discusses the fabrication and testing of polyvinyl alcohol (PVOH) samples as a neutron shielding material, with comparison to medium density polyethylene (MDPE) composite samples to be used for neutron shielding for spacecraft. PVOH, an aqueous polymer, was chosen for hydrogen content and for enabling the use of organic reinforcement such as cellulose for secondary structural composites. OLTARIS (On-Line Tool for the Assessment of Radiation in Space) was used for radiation shielding simulation and compared with experimental data. Modeling indicates that the most effective shielding from radiation was in an aluminum layer backed by a polymer layer, either MDPE or PVOH. Cross-linked PVOH was also included in the OLTARIS modeling. All 3 polymer cases showed shielding improvement over aluminum alone, with similar dose equivalent reduction for galactic cosmic radiation(GCR)and for radiation from a solar particle event (SPE). Fourier Transform Infrared (FTIR) Spectroscopy was used to confirm the cross-linking in the PVOH sample and to determine the uniformity through the thickness. PVOH, cross-linked PVOH, and MDPE samples were tested for neutron shielding effectiveness using a 1 curie Americium-Beryllium neutron source. Test results indicated the most shielding in the cross-linked PVOH, followed by the pristine PVOH, and MDPE. Neutron testing suggests that polyvinyl alcohol is a good alternative to polyethylene for neutron shielding. The neutron shielding materials, PVOH and cross-linked PVOH developed under this research will enable the safe operation of spacecraft beyond the Earth’s protective Van Allen Radiation Belts. It will be crucial for NASA’s manned missions to the Moon or Mars to protect the health of astronauts and equipment from the harmful effects of excessive radiation.

neutron, shielding, radiation, polyvinyl alcohol, ↗

Trapped belt variations and their effects on human space flights

Variations in the Earth's trapped (Van Allen) belts produced by solar flare particle events are not well understood. This paper reports the existence of a second proton belt and its subsequent decay as measured by a tissue-equivalent proportional counter and a particle spectrometer on five Space Shuttle flights covering an 18-month period. The creation of this second belt is attributed to the injection of particles from a solar particle event which occurred at 2246 UT, March 22, 1991. Comparisons with observations onboard the Russian Mir space station and other unmanned satellites are made. Shuttle measurements and data from other spacecraft are used to determine that the e-folding time of the peak of the second proton belt was ten months. Proton populations in the second belt returned to values of quiescent times within 18 months. The increase in absorbed dose attributed to protons in the second belt was approximately 20 percent. Passive dosimeter measurements were in good agreement with this value.