Search NASA⌕ Search

SEARCH · Search NASA

Results for “VIBRATION MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Molecular beam mass spectrometry measurements of vibrationally excited N 2 in the effluent of an atmospheric plasma jet: a comparison with a state-to-state kinetic model

Vibrationally excited N 2 molecules are suggested to be one of the possible key species responsible for the observed synergistic effects in plasma catalysis for NH 3 synthesis. To assess the impact of vibrationally excited species in plasma-catalysis, quantitative measurements near interfaces are required, which remains challenging. In this letter, we report spatially resolved measurements of vibrationally excited N 2 in the effluent of an atmospheric pressure plasma jet by molecular beam mass spectrometry (MBMS). The mass spectrometry signals as a function of electron energy of the ionizer were fitted with the effective electron-impact ionization cross section of N 2 (v) considering the vibrational distribution function as determined by a detailed vibrational level resolved plasma kinetic calculation. Here, the reported method presented in this letter shows the capability of MBMS to measure vibrationally excited species of N 2 near interfaces when the vibrational distribution function is known or assumed and shows excellent agreement with state-to-state kinetic models of N 2 (v).

42 ENGINEERING↗

Stroboscopic Interferometer for Measuring Mirror Vibrations

Stroboscopic interferometry is a technique for measuring the modes of vibration of mirrors that are lightweight and, therefore, unavoidably flexible. The technique was conceived especially for modal characterization of lightweight focusing mirror segments to be deployed in outer space; however, the technique can be applied to lightweight mirrors designed for use on Earth as well as the modal investigation of other optical and mechanical structures. To determine the modal structure of vibration of a mirror, it is necessary to excite the mirror by applying a force that varies periodically with time at a controllable frequency. The excitation can utilize sinusoidal, square, triangular, or even asynchronous waveforms. Because vibrational modes occur at specific resonant frequencies, it is necessary to perform synchronous measurements and sweep the frequency to locate the significant resonant modes. For a given mode it is possible to step the phase of data acquisition in order to capture the modal behavior over a single cycle of the resonant frequency. In order to measure interferometrically the vibrational response of the mirror at a given frequency, an interferometer must be suitably aligned with the mirror and adjustably phase-locked with the excitation signal. As in conventional stroboscopic photography, the basic idea in stroboscopic interferometry is to capture an image of the shape of a moving object (in this case, the vibrating mirror) at a specified instant of time in the vibration cycle. Adjusting the phase difference over a full cycle causes the interference fringes to vary over the full range of motion for the mode at the excitation frequency. The interference-fringe pattern is recorded as a function of the phase difference, and, from the resulting data, the surface shape of the mirror for the given mode is extracted. In addition to the interferometer and the mirror to be tested, the equipment needed for stroboscopic interferometry includes an arbitrary-function generator (that is, a signal generator), an oscilloscope, a trigger filter, and an advanced charge-coupled-device (CCD) camera. The optical components are positioned to form a pupil image of the mirror under test on the CCD chip, so that the interference pattern representative of the instantaneous mirror shape is imaged on the CCD chip.

Stahl, H. Philip↗

Physical and subjective studies of aircraft interior noise and vibration

Measurements to define and quantify the interior noise and vibration stimuli of aircraft are reviewed as well as field and simulation studies to determine the subjective response to such stimuli, and theoretical and experimental studies to predict and control the interior environment. In addition, ride quality criteria/standards for noise, vibration, and combinations of these stimuli are discussed in relation to the helicopter cabin environment. Data on passenger response are presented to illustrate the effects of interior noise and vibration on speech intelligibility and comfort of crew and passengers. The interactive effects of noise with multifrequency and multiaxis vibration are illustrated by data from LaRC ride quality simulator. Constant comfort contours for various combinations of noise and vibration are presented and the incorporation of these results into a user-oriented model are discussed. With respect to aircraft interior noise and vibration control, ongoing studies to define the near-field noise, the transmission of noise through the structure, and the effectiveness of control treatments are described.

Stephens, D. G.↗

Modal Frequency Identification of a Cylindrical Object from Noisy Vibrational Response Measurements

The investigation of the vibrational response of a cylindrical object in a noisy environment (a pipe in air) to impact excitations provided by a cam-driven, hammer-like surface, randomly excited by an electric motor is of high interest—especially when potential anomalies can occur. This project encompasses all of the components from modeling to validation to controlled testing and signal processing in order develop a real-time system capable of on-board performance and monitoring.

42 ENGINEERING↗

Optical Calibration Process Developed for Neural-Network-Based Optical Nondestructive Evaluation Method

A completely optical calibration process has been developed at Glenn for calibrating a neural-network-based nondestructive evaluation (NDE) method. The NDE method itself detects very small changes in the characteristic patterns or vibration mode shapes of vibrating structures as discussed in many references. The mode shapes or characteristic patterns are recorded using television or electronic holography and change when a structure experiences, for example, cracking, debonds, or variations in fastener properties. An artificial neural network can be trained to be very sensitive to changes in the mode shapes, but quantifying or calibrating that sensitivity in a consistent, meaningful, and deliverable manner has been challenging. The standard calibration approach has been difficult to implement, where the response to damage of the trained neural network is compared with the responses of vibration-measurement sensors. In particular, the vibration-measurement sensors are intrusive, insufficiently sensitive, and not numerous enough. In response to these difficulties, a completely optical alternative to the standard calibration approach was proposed and tested successfully. Specifically, the vibration mode to be monitored for structural damage was intentionally contaminated with known amounts of another mode, and the response of the trained neural network was measured as a function of the peak-to-peak amplitude of the contaminating mode. The neural network calibration technique essentially uses the vibration mode shapes of the undamaged structure as standards against which the changed mode shapes are compared. The published response of the network can be made nearly independent of the contaminating mode, if enough vibration modes are used to train the net. The sensitivity of the neural network can be adjusted for the environment in which the test is to be conducted. The response of a neural network trained with measured vibration patterns for use on a vibration isolation table in the presence of various sources of laboratory noise is shown. The output of the neural network is called the degradable classification index. The curve was generated by a simultaneous comparison of means, and it shows a peak-to-peak sensitivity of about 100 nm. The following graph uses model generated data from a compressor blade to show that much higher sensitivities are possible when the environment can be controlled better. The peak-to-peak sensitivity here is about 20 nm. The training procedure was modified for the second graph, and the data were subjected to an intensity-dependent transformation called folding. All the measurements for this approach to calibration were optical. The peak-to-peak amplitudes of the vibration modes were measured using heterodyne interferometry, and the modes themselves were recorded using television (electronic) holography.

Decker, Arthur J.↗

On-line analysis of random vibrations

Measuring device, Randomdec, provides continuous on-line signatures representative of system free vibration curve. Selected points on curve are used in control and failure detection systems. Apparatus applied to both linear and nonlinear systems under nonstationary vibratory states.

Cole, H. A., Jr.↗

Characteristics of a liquid-helium-free calibration apparatus for cryogenic thermometers

Closed-cycle Joule-Thomson (JT) cryocoolers have been developed at National Metrology Institute of Japan (NMIJ)/National Institute of Advanced Industrial Science and Technology (AIST) with the aim of realizing a liquid-helium-free calibration apparatus for cryogenic thermometers between 0.65 K and 25 K. The latest JT cryocooler at NMIJ/AIST consists of a {sup 3}He JT cooling circuit and a pulse tube mechanical refrigerator. The characteristics of the apparatus including a residual gas analysis of the JT cooling circuit are presented in this paper. Currently the initial cool-down is performed using a heat-exchange gas. It normally takes about 30 h to reduce the temperature from room temperature to 5 K at the thermometer comparison block of the apparatus. The correct timing of the removal of the heatexchange gas is important for the efficient operation of the apparatus. Incomplete removal of the heat-exchange gas induces excess heat load on the apparatus and thermal disturbances. Some examples of abrupt temperature bursts are discussed in this paper. Mechanical refrigerators generate cyclic mechanical vibrations, and precision resistance thermometers are usually very sensitive to a mechanical vibration. The measured vibration level of the developed apparatus is reported. The damage to the apparatus due to the magnitude 9.0 earthquake on March 11, 2011, and possible countermeasures in the case of future earthquakes are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detecting Faults In Helicopter Gearboxes By The MVIM Method

Multivalued influence-matrix (MVIM) method potential utility as theoretical basis of proposed automated monitoring systems detecting faults in helicopter gearboxes. Applied to recognize patterns in vibration measurements. Fault-recognition system required to operate continuously while helicopter airborne, analyzing measurements of vibrations for signs of trouble to provide real-time warning of any dangerous or potentially dangerous fault like cracked case or fractured gear tooth. System also required not to give false alarms to prevent unnecessary emergency landings.

Chin, Hsinyung↗

Microwave Photonics for Distributed Sensing

In the past few years, microwave-photonics technologies have been investigated for optical fiber sensing. By introducing microwave modulation into the optical system, the optical detection is synchronized with the microwave modulation frequency. As a result, the system has a high SNR and thus an improved detection limit. In addition, the phase of the microwave-modulated light can be obtained and Fourier transformed to find the time-of-arrival information for distributed sensing. Recently, an incoherent optical-carrier-based microwave interferometry (OCMI) technique has been demonstrated for fully distributed sensing with high spatial resolution and large measurement range. Since the modal interference has little influence on the OCMI signal, the OCMI is insensitive to the types of optical waveguide. Motivated by the eeds of distributed measurement in the harsh environment, in the first part of this paper, several OCMI-based sensing systems were built by using special multimode waveguides to perform sensing for heavy duty applications. Driven by an interest on the high-resolution sensing, in the second part of the paper, I propose a coherence-gated microwave photonics interferometry (CMPI) technique, which uses a coherent light source to obtain the optical interference signal from cascaded weak reflectors. The coherence length of the light source is carefully chosen or controlled to gate the signal so that distributed sensing can be achieved. The experimental results indicate that the strain resolution can be better than 0.6 μ using a Fabry-Perot interferometer (FPI) iii with a cavity length of 1.5 cm. Further improvement of the strain resolution to the 1 n level is achievable by increasing the cavity length of the FPI to over 1m. The CMPI has also been utilized for distributed dynamic measurement of vibration by using a new signal processing method. The fast time-varying optical interference intensity change induced by the sub-scan rate vibration is recorded in the frequency domain. After Fourier transform, distinctive features are shown at the vibration location in the time domain signal, where the vibration frequency and intensity can be retrieved. The signal processing method supports vibration measurement of multiple points with the measurable frequency of up to 20 kHz.

Hua, Liwei↗

Changing Stiffnesses Of Truss Members For Vibration Tests

Extension of active-member method of vibration testing of trusses and similar structures proposed to obtain additional data for refinement of finite-element mathematical models of vibrational properties of structures. Active truss members not only used in vibration tests to excite and measure vibrations of structures, but also made to have different effective stiffnesses in some tests, enabling excitation of different vibrational modes yielding additional data. Aspects of active-member method of vibration testing described previously in articles in NASA Tech Briefs including "Two Techniques for Suppressing Vibrations in Structures" (NPO-17889), "Active Suppression of Vibrations in a Truss" (NPO-18305), and "Active Members Excite and Measure Vibrations in Trusses" (NPO-18353).

Wada, Ben K.↗

Contribution of acoustic modes to the density of vibrational states measured by inelastic scattering techniques

We consider the contribution of acoustic modes to the density of vibrational states measured by nuclear inelastic, inelastic x-ray, and inelastic neutron scattering. In nuclear and x-ray scattering, the low-energy part of the density of states (DOS) is compared with the contribution of acoustic modes to the generalized density of states. Different to that, in neutron scattering the DOS is compared with the contribution of acoustic modes to the true density of states. We argue that in general this is not correct and that similar to nuclear and x-ray scattering, the neutron data in most cases must also be compared with the contribution of acoustic modes to the generalized DOS. For neutron scattering, this contribution usually is smaller than the contribution to the true DOS. Thus, the comparison of the neutron data with the contribution of acoustic modes to the true DOS systematically overestimates the level of acoustic modes. However, an extrapolation of the neutron DOS to zero energy often exceeds even this overestimated level. In our eyes, even for glasses the manifold excess of the extrapolation of the neutron DOS to zero energy over the expected level of acoustic modes seems to be unreasonable even though in this case one can still argue on existing of additional soft modes. However, a similar excess observed also for crystalline samples clearly indicates an uncertainty of the absolute scale of the DOS measured by neutron scattering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Time-resolved CO 2 , CO, and N 2 vibrational population measurements in Ns pulse discharge plasmas

Abstract Time-resolved CO 2 and N 2 vibrational populations and translational-rotational temperature are measured in a CO 2 –N 2 plasma sustained by a ns pulse discharge burst in plane-to-plane geometry. Time-resolved, absolute number density of CO generated in the plasma is also inferred from the experimental data. CO 2 and CO vibrational populations are measured by mid-IR, tunable quantum cascade laser absorption spectroscopy, and N 2 vibrational populations are measured by the ns broadband vibrational CARS. Transient excitation of N 2 and CO 2 asymmetric stretch vibrational energy modes is detected during the discharge burst. The time-resolved rate of CO generation does not correlate with N 2 or CO 2 ( ν 3 ) vibrational temperatures, indicating that CO 2 dissociation via the vibrational excitation is insignificant at the present conditions. The rate of CO generation decreases gradually during the discharge burst. The estimated specific energy cost of the CO product is close to that of N atoms in pure nitrogen, measured previously at similar operating conditions. Comparison of the experimental data with the kinetic modeling analysis indicates that CO 2 dissociation in collisions with electronically excited N 2 molecules is the dominant channel of CO generation at the present conditions, although the inferred CO yield in these processes is significantly lower than 1. The effect of vibrational energy transfer between N 2 and CO 2 on the plasma chemical processes is insignificant. The kinetic model underpredicts a rapid reduction of the N 2 and CO 2 ( ν 3 ) vibrational temperatures during the later half of the discharge burst and in the afterglow. V–T relaxation of N 2 by N and O atoms generated in the ns pulse discharge plasma does not affect the vibrational relaxation rate in a significant way. However, rapid V–T relaxation of CO 2 by O atoms has a significant effect on the relaxation rate. The difference between the experimental data and the modeling predictions may be due to the unknown scaling of the CO 2 –O V–T rates with the vibrational quantum number.

Physics↗

Acoustical measurements of vibrational relaxation in moist N2 at elevated temperatures

Sound absorption measurements are conducted by the resonant tube technique to study vibrational relaxation in moist N2 at 301, 343, and 387 K. Analysis of the data shows that improved measurement accuracy at the higher temperatures establishes vibrational-vibrational energy transfer as the operative relaxation path for the de-excitation of N2 by H2O beyond the uncertainty of experimental error. The best-fitted temperature dependence of the vibrational-vibrational rate constant is given, noting that the expression is consistent with seven independent sets of both acoustical and nonacoustical data.

Zuckerwar, A. J.↗