Search NASA⌕ Search

SEARCH · Search NASA

Results for “Variable Speed Pumps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Variable speed drive

A variable speed drive wherein a first embodiment is comprised of a pivotally mounted prime mover coupled to a rotary fluid output device, such as a fan or pump, through a variable and fixed pulley drive arrangement is described. The pivotal position of the prime mover and accordingly the pitch diameter of variable pulley means is controlled in accordance with fluid motor means coupled to the prime mover. This is actuated in response to a fluid feedback control signal derived from a sensed output of the rotary fluid output device. The pivotal motion of the prime mover imparts an arcuate motion to the variable pulley means which effects a speed variation of the rotary fluid output device in accordance with the variation of the pitch diameter ratio of opposing variable and fixed pulley means.

Obler, H. D.↗

Market Opportunities and Challenges for Pumped Hydro in an Evolving Power Grid: Preprint

The paper explores several market opportunities and challenges for pumped storage hydropower (PSH) related to ongoing changes in the electric power grid. Two PSH technologies are investigated - single-speed pump/turbine and variable-speed pump/turbine units - under three variable generation penetration scenarios. The results provide a way to do relative comparisons of the opportunities and challenges that pumped storage hydro faces as the variable generation in a system increases.

13 HYDRO ENERGY↗

Irrigation system

A gravity irrigation system includes a distribution piping having apertures to distribute water to a field, and a valve located upstream of the distribution piping. The valve limits a pressure of the water being delivered to the distribution piping. The system also includes a sump to receive the water at a lowest elevation of the field, a depth sensor disposed within the sump, and a return pump disposed at least partially within the sump to move the water to an elevated portion of the field. The system also includes a motor to drive the return pump, and a power source coupled to a variable frequency drive that powers the motor and controls a motor speed proportionately to an indication of the depth sensor. The system also includes a transfer piping to bring the water from the return pump to a check valve and to the distribution piping.

Henry, Christopher G.↗

Cost-Optimized CCHP Model Developed Using HPDM Meeting Performance Targets

This report documents the equipment design and analysis work to meet the first project milestone (M1). Our industry partner, Emerson Commercial & Residential Solutions recently developed a 3-stage scroll compressor product, able to deliver capacity at three levels without using an inverter. Based on ORNL’s previous cold climate heat pump (CCHP) prototype and the preliminary compressor performance data, the CCHP was redesigned for cost reduction and better performance. The 3-stage compressor, using the middle capacity level to deliver the rated capacity of the heat pump (HP), will replace the previous tandem compressors, using one single-speed compressor to deliver the rated capacity. In this way, it will reduce the compressor footprint to fit in most residential HPs’ chassis. The compressor replacement increases the nominal capacity by 17%. Approximately, 30% cost reduction in the compressor and 17% reduction in the heat exchangers per nominal tonnage can be achieved relative to the prior tandem compressor design. Advanced features using an electronic expansion valve for head pressure control and an Ebm-papst variable-speed, backward-curved indoor blower can be adopted for higher efficiency.The DOE/ORNL Heat Pump Design Model (HPDM) was used to model and redesign the CCHP. Following AHRI 210/240, heating and cooling performance results were predicted at the conditions for certifying a 2-stage CCHP, regarding various design scenarios. The predicted HSPF reaches 12.0, and predicted SEER reaches16.2.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a Residential Ground-Source Integrated Heat Pump

A residential-size ground-source integrated heat pump (GSIHP) system has been developed and is currently being field tested. The system is a nominal 2-ton (7 kW) cooling capacity, variable-speed unit, which is multi-functional, e.g. space cooling, space heating, dedicated water heating, and simultaneous space cooling and water heating. High-efficiency brushless permanent-magnet (BPM) motors are used for the compressor, indoor blower, and pumps to obtain the highest component performance and system control flexibility. Laboratory test data were used to calibrate a vapor-compression simulation model (HPDM) for each of the four primary modes of operation. The model was used to optimize the internal control options and to simulate the selected internal control strategies, such as controlling to a constant air supply temperature in the space heating mode and a fixed water temperature rise in water heating modes. Equipment performance maps were generated for each operation mode as functions of all independent variables for use in TRNSYS annual energy simulations. These were performed for the GSIHP installed in a well-insulated 2600 ft2(242 m2) house and connected to a vertical ground loop heat exchanger(GLHE). We selected a 13 SEER (3.8 CSPF )/7.7 HSPF (2.3 HSPF, W/W) ASHP unit with 0.90 Energy Factor (EF) resistance water heater as the baseline for energy savings comparisons. The annual energy simulations were conducted over five US climate zones. In addition, appropriate ground loop sizes were determined for each location to meet 10-year minimum and maximum design entering water temperatures (EWTs) to the equipment. The prototype GSIHP system was predicted to use 52 to 59% less energy than the baseline system while meeting total annual space conditioning and water heating loads.

Energy Efficiency↗

Recommended Practice for Pressure Measurements and Calculation of Effective Pumping Speeds During Electric Propulsion Testing

The electric propulsion community has been implored to establish and implement a set of universally applicable test standards during the research, development, and qualification of electric propulsion systems. Variability between facility-to-facility and more importantly ground-to-flight performance can result in large margins in application or aversion to mission infusion. Performance measurements and life testing under appropriate conditions can be costly and lengthy. Measurement practices must be consistent, accurate, and repeatable. Additionally, the measurements must be universally transportable across facilities throughout the development, qualification, spacecraft integration, and on-orbit performance. A recommended practice for making pressure measurements, pressure diagnostics, and calculating effective pumping speeds with justification is presented.

Dankanich, John W.↗

A High-Efficient Solution for Electro-Hydraulic Actuators with Energy Regeneration Capability

This paper proposes a cost-effective, robustly practical solution for a high-efficient electro-hydraulic actuator (EHA) for linear drives. The solution addresses the challenges of high costs and limited efficiency that limit the application of EHA for the electrification of many off-road vehicles. Based on a variable-speed electric motor and a low-cost technology for a fixed-displacement pump, the proposed solution is suitable for a compact implementation and it is capable of energy regeneration under overrunning load conditions. Two different architectures—an open circuit and a closed circuit one—are considered to determine the most practical and efficient configuration as well as the control features. Both architectures minimize throttling losses associated with the conventional regulation of hydraulic actuators. Actuator velocities below the minimum and beyond the maximum allowable pump flow rate are achieved in both architectures using a proportional valve that bypasses the pump flow. The paper describes the design methodology as well as the simulation and experimental activities performed to verify the control strategies as well as energy efficiency. Considering an EHA system of about 20 kW, a complete efficiency map of the system is determined for all the possible four quadrants of operation thus including both resistive and overrunning loads, where energy recuperation is implemented. Simulation and experimental results show that the energy efficiency of the hydraulic systems can reach 84.7% in resistive phases. In assistive phases, the hydraulic system can recover up to 81.8% of the actuator energy. Here, the comparison between open-circuit and closed-circuit structures shows the advantages of the former in terms of energy efficiency. The proposed solution is suitable for electrified hydraulic actuation systems, in both industrial and mobile applications. With the advantages of the low cost of the hydraulic unit and high energy efficiency, it is particularly suitable for mobile applications such as construction machines, that are recently experiencing a significant electrification trend.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Residential Variable-Capacity Heat Pumps Sized to Heating Loads

Variable capacity heat pumps are an emerging technology offering significant energy savings potential and improved efficiency. With conventional single-speed systems, it is important to appropriately size heat pumps for the cooling load as over-sizing would result in cycling and insufficient latent capacity required for humidity control. These appropriately sized systems are often under-sized for the heating load and require inefficient supplemental electric resistance heat to meet the heating demand. Variable capacity heat pumps address these shortcomings by providing an opportunity to intentionally size systems for the dominant heating season load without adverse effects of cycling or insufficient dehumidification in the cooling season. This intentionally-sized system could result in significant energy savings in the heating season, as the need for inefficient supplemental electric resistance heat is drastically reduced. This is a continuation of a study evaluating the energy consumption of variable capacity heat pumps installed in two unoccupied research homes in Farragut, a suburb of Knoxville, Tennessee. In this particular study, space conditioning systems are intentionally sized for the heating season loads to provide an opportunity to understand and evaluate the impact this would have on electric resistance heat use and dehumidification. The results and conclusions drawn through this research are valid and specific for portions of the Southeastern and Midwestern United States falling in the mixed-humid climate zone. While other regions in the U.S. do not experience this type of climate, this work provides a basis for, and can help understand the implications of other climate zones on residential space conditioning energy consumption. The data presented here will provide a framework for fine tuning residential building EnergyPlus models that are being developed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Performance Circulator Pump Demonstration

In commercial buildings, smaller circulator pumps are typically overlooked for energy efficiency upgrades due to their smaller size (typically less than 2.5 hp) and due to the lack of commercially available products that can simultaneously provide a combination of integrated controls and variable speed operation that is required to achieve acceptable energy savings and life cycle cost effectiveness. This General Services Administration (GSA) Green Proving Ground (GPG) project assessed the performance of a new high performance circulator pump (HPCP) at one heating hot water (HHW) application and two domestic hot water (DHW) application at the Denver Federal Center in Denver, Colorado.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Residential Cold Climate Heat Pump (CCHP) w/Variable Speed Technology

This report summarizes the results of a three year program awarded to Unico, Inc. to commercialize a residential cold climate heat pump. Several designs were investigated. Compressors were selected using analysis from Oakridge National Laboratories followed by prototype construction and lab testing in a specially built environmental chamber capable of reaching -30°F. The initial design utilized two variable speed compressors in series with very good capacity results and acceptable efficiency at very cold temperatures. The design was then modified to reduce cost and complexity by redesigning the system using three dual-stage compressors: two in parallel followed by one in series. Extensive testing found significant challenge with oil management, reliability, weight and cost which prevented the system from being fully commercialized. Further analysis of other conceptual designs indicated that these challenges could be overcome in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

VALVE TIMING AND AREA PROFILE SELECTION FOR HYDRAULIC PUMPS AND MOTORS

A significant amount of research has been conducted to select valve timing and area profiles that create efficient and quiet hydraulic pumps and motors. Numerous active valve architectures have been modeled and optimized, but the rationale for the final solution is often unclear. The solution is usually highly dependent on the modeled valve geometry constraints and the duty cycle of the pump or motor for which the valve was optimized. This paper first presents an ideal valve area profile and what compromises are made to design for a working pressure and speed range. The ideal valve area profile is resolved using a piston-cylinder model with a pressure dependent bulk modulus and variable valve openings. The piston-cylinder is first modeled as a pump with passive (check) valves and a specified pressure drop across the valves to determine the ideal area profile. A generalization of the ideal timing is demonstrated for positive pressure differential and positive rotation direction, also known as the first quadrant. The effects on valve timing when varying pressure are shown for the first quadrant, but the trends can be extrapolated for all quadrants of operation. The ideal valve profile is implemented as fixed valve timing, meaning the valve area is only a function of the timing angle, in a pump-motor. The pump-motor is simulated in one rotation direction through a pressure range. Performance is high in pumping operation, but when the pressure differential is reversed, cylinder pressure spikes ensue. Two strategies to modify an ideal valve area profile are presented: timing grooves and a pressure shifted valve timing. Timing grooves reduce pressure spikes and cavitation in the cylinder but generally increase throttling losses. A pressure shifted valve timing has lower throttling energy losses, making it the favored solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improving the Energy Efficiency of Pumped-Storage Power Plants

Possible ways to improve the energy efficiency of hydroelectric generating sets of pumped-storage power plants (PSPPs) are studied. The Kiev PSPP is used as an example to show how its generating sets can be upgraded. It is concluded based on studies conducted that synchronous motor-generators should be replaced with asynchronized motor-generators. The feasibility of changing over the turbine to variable-speed operation is shown.

42 ENGINEERING↗

Design and Development of a Residential Gas-Fired Heat Pump

Heating, ventilating, and air-conditioning equipment consumes 43% of the total primary energy consumption in U.S. households. Presently, conventional gas furnaces have maximum heating efficiencies of 98%. Electric air conditioners used in association with the furnace for cooling have a minimum seasonal energy efficiency ratio (SEER) of 14.0. A residential gas-fired heat pump (RGHP) was developed and tested under standard rating conditions, resulting in a significant increase in heating efficiency of over 40% versus conventional natural gas furnaces. The associated efficiency of the RGHP in cooling mode is comparable in efficiency to an electric air conditioner (14.0 SEER) when compared on a primary energy basis. The RGHP is similar in nature to a conventional heat pump but with two main differences. First, the primary energy savings are higher, based on a site versus source comparison, as the result of using natural gas to supply shaft power to the compressor rather than an electric motor. Second, waste heat is recovered from the engine to supplement space heating and reduce the energy input. It can also be used to provide supplemental water heating. The system utilizes a programmable logic controller that allows variable-speed operation to achieve improved control to meet building loads. RGHPs significantly reduce peak electric use during periods of high demand, especially peak summer loads, as well as peak winter loads in regions with widespread use of electric heating. This contributes to leveling year-round gas loads, with the potential to increase annual gas demand in some regions. The widespread adoption of RGHPs will contribute to significant reductions in primary energy consumption and carbon emissions through improved efficiencies.

energy efficiency↗

South Texas Industrial Assessment Center (Final Report)

The South Texas Industrial Assessment Center (ST-IAC) provides small to mid-size manufacturing companies and water treatment plants in the Rio Grande Valley of Texas, free energy assessments to help them reduce costs and stay competitive for sustainable development. The ST-IAC operates within the University of Texas Rio Grande Valley (UTRGV), and is the largest Hispanic-serving IAC in the U.S. Created in 2016, the ST-IAC, situated in the most economically disadvantaged region in the country, has been successful in training students and assessing local industries served by a predominantly Hispanic population. UTRGV, now the second largest Hispanic Serving Institution (HSI) of higher education in the U.S., has a student population of 32,000, of which 90% is Hispanic. While Covid-19 had a negative impact to our program during Budget Periods (BP) 4 and 5, the center still managed to provide opportunities for individuals, manufacturing and water industries in the local region. The program developed an energy engineering program in the region and further advanced national priorities. Those include resilience and sustainability of operations by implementing energy efficiency processes, renewable energy sources, decarbonization, battery storage, and cybersecurity in south Texas.

14 SOLAR ENERGY↗

Cold Climate Heat Pump Evaluation

The use of heat pumps in cold and very cold climates increased by 63% between 2009 and 2015 [1, 2]. This can be attributed to development of heat pumps with higher heating capacity at lower temperatures and increased efficiency. A primary technology driving this trend is the use of variable-speed compressors, which come with an increase in the level of controls in the equipment. Most units with variable-speed compressors also include electronic expansion valves and variable-speed indoor (ID) and outdoor (OD) fans. With the increased complexity of these systems, developing a test procedure that is representative of typical performance and not too burdensome on manufacturers presents a difficult challenge.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enabling off-highway diesel engine downsizing and performance improvement using electrically assisted turbocharging

Internal combustion engine (ICE) downsizing through various turbocharging configurations is generally known by the powertrain design community as an effective means to reduce frictional losses, increase waste heat recovery, and improve fuel efficiency while increasing engine power density. However, often is the case that turbocharging strategies, including variable geometry turbochargers, and regulated two-stage turbochargers, incur the performance tradeoff between transient response and fuel economy (pumping losses) at high engine speeds. For off-highway vehicles having particularly transient and high-powered duty cycles, efforts to improve this tradeoff and increase operational flexibility have turned to evaluating various electrified air system architectures. In this study, a 4.5 L diesel-ICE configured with an electrically driven compressor (eBooster ® ) is placed in series with a conventional turbocharger and integrated into a 48 V mild-hybrid powertrain architecture. The objective of this powertrain configuration is to enable engine downsizing by 34%, replacing the current 6.8 L ICE platform with the hybridized 4.5 L ICE concept. The commercial 1-D simulation software GT-SUITE is used for powertrain system development and system optimization. Development and validation of the GT-SUITE model and air system controls is concurrently supported through experimental data collection. The simulation model development includes using machine learning methods for optimizing exhaust gas dilution, injection timing, and eBooster ® power to improve steady-state and transient brake-specific fuel consumption while minimizing criteria pollutant emissions. It was found that total specific fluid consumption over the standardized non-road transient engine duty cycle could be reduced by 18% over the current 6.8 L engine by using an optimized eBoosted 4.5 L engine. The hybridized 4.5 L engine concept concurrently showed sufficient transient response capability and nearly an order of magnitude reduction in duty cycle total soot production.

25 ENERGY STORAGE↗

Variable Frequency Drive (VFD): Emphasizing Energy Savings and Efficiency in Industrial Applications

This project explores the energy saving potential of using a VDA in an industrial pumping application. A 24-horsepower pump, 3-phase centrifugal pump powered by 480V AC supply analyzed under variable frequency control using an ABB ACS880-31-052A-5 VFD. by modulating the motor speed between 30Hz and 60Hz, the VFD enables precise control of power consumption based on system set speed. The article is intended for public cause of the poster session and presentation session. INL/Exp-25-86570

99 - GENERAL AND MISCELLANEOUS↗

Laboratory Evaluation and Field Demonstration of High Rotor Switched Reluctance Motor (HRSRM) Technology

In this project, a new motor technology based on a novel design called a High Rotor Pole Switched Reluctance Motor (HRSRM) was demonstrated and evaluated. The HRSRM system combines an innovative electric motor design with a programmable variable-speed drive and a controller that provides real time monitoring and cloud-based connectivity. Unlike induction or permanent-magnet motor designs, this motor uses a switched reluctance (SR) design that purports to be simpler to manufacture and more reliable and efficient to operate. Several of the stated benefits of the HRSRM system were evaluated as part of this project. First, the technology is claimed to offer greater energy efficiency than any motor currently on the market. Second, according to the manufacturer, the motor can be dropped into an existing pump or heating, ventilation, and air-conditioning application in less than 30 minutes, and has controls that can be pre-programmed to interact with the application’s existing control structure. Third, the control system allows the HRSRM to replace a constant-speed motor with one that provides variable-speed capabilities without requiring the installation of a variable-speed drive. The evaluation of a 10 hp HRSRM system was conducted in two parts. One portion of the evaluation consisted of performance tests conducted in a tightly controlled laboratory environment in which the performance of the HRSRM system was compared with that of a premium efficiency induction motor with a variable-frequency drive. The other portion of the evaluation was conducted at a field location within a General Services Administration facility in which the HRSRM system replaced an existing motor system in a 10 hp chilled water pump. The performance of the HRSRM system was compared with that of the incumbent motor system that was supplied with the pump from the manufacturer. The overall project and performance objectives for this motor evaluation are defined in Table ES.1.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗