Cardiovascular function during sustained +G/z/ stress

The development of aerospace systems capable of very high levels of positive vertical accelerators stress has created a need for a better understanding of the cardiovascular responses to acceleration. Using a canine model, the heart and cardiovascular system were instrumented to continuously measure coronary blood flow, cardiac output, left ventricular and aortic root pressure, and oxygen saturation in the aorta, coronary sinus, and right ventricle. The animals were exposed to acceleration profiles up to +6 G, 120 s at peak G; a seatback angle of 45 deg was simulated in some experiments. Radiopaque contrast medium was injected to visualize the left ventricular chamber, coronary vasculature, aorta, and branches of the aorta. The results suggest mechanisms responsible for arrhythmias which may occur, and subendocardial hemorrhage which has been reported in other animals.

Erickson, H. H.↗

Right and left ventricular volumes in vitro by a new nongeometric method

We present an evaluation of a new nongeometric technique for calculating right and left ventricular volumes. This method calculates ventricular chamber volumes from multiple cross-sectional echocardiographic views taken from a single point as the echo beam is tilted progressively through the ventricle. Right and left ventricular volumes are calculated from both the approximate short axis and approximate apical position on 20 in vitro human hearts and compared with the actual chamber volumes. The results for both ventricles from both positions are excellent. Correlation coefficients are > 0.95 for all positions; the standard errors are in the range of 5 to 7 mL and the slopes and intercepts for the regression lines are not significantly different from 1 and 0, respectively (except for the left ventricular short-axis intercept). For all positions, approximately 6 to 8 views are needed for peak accuracy (7.5 degrees to 10 degrees separation). This approach offers several advantages. No geometric assumptions about ventricular shape are made. All images are acquired from a single point (or window), and the digitized points can be used to make a three-dimensional reconstruction of the ventricle. Also, during the calculations a volume distribution curve for the ventricle is produced. The shape of this curve can be characteristic for certain situations (ie, right ventricle, short axis) and can be used to make new simple equations for calculating volume. We conclude that this is an accurate nongeometric method for determining both right and left ventricular volumes in vitro.

NASA Discipline Cardiopulmonary↗

Influences of physical training on the heart of dogs

To investigate the effects of physical training on cardiac dimensions and function, eight dogs were exercised for 12 weeks by treadmill running 1 hour/day, 5 days/week. Five dogs were confined in cages as controls for an 8-week period. Heart rates were monitored by telemetry during rest and exercise. Maximum QRS spatial magnitudes were calculated from records of McFee lead electrocardiograms. Left ventricular end-diastolic dimensions were determined radiographically by the bead and clip technique. Training produced statistically significant decreases in heart rate at rest and at a standard work load of 6.1 mph on a level treadmill and statistically significant increases in work load at a standard heart rate of 194 beats/min. Improvements were rapid during the first 4 weeks of training but gradual during the remaining 8 weeks. Training caused small but statistically significant increases in left ventricular end-diastolic wall thickness, estimated left ventricular mass, and maximum QRS spatial magnitude.

Wyatt, H. L.↗

Effect of Actual and Simulated Microgravity on Cardiac Mass and Function in the Rat

The purpose of this study was to test the hypothesis that exposure to actual or simulated microgravity induces cardiac atrophy in male Sprague-Dawley rats. For the microgravity study, rats were subdivided into four groups: Preflight (PF, n = 12); Flight (FL, n = 7); Flight Cage Simulation (SIM, n = 6), and Vivarium Control (VIV, n = 7). Animals in the FL group were exposed to 7 days of microgravity during the Spacelab 3 mission. Animals in the simulated microgravity study were subdivided into three groups: Control (CON, n = 20); 7 day hindlimb unloaded (7HU, n = 10); and 28 day unloaded (28HU, n = 19). In a subset of CON (n = 7) and 28HU (n = 6) rats, a catheter was advanced into the left ventricle to measure the rate of rise in ventricular pressure (+dP/dt) during standing as an estimate of cardiac contractility. After completion of their respective treatments, hearts were removed and weighed. Animals in the PF group were sacrificed 24 hr prior to launch while the FL group was sacrificed 11- 17 hr after landing. The SM and VIV groups were sacrificed 48 and 96 hr after the FL group, respectively. Heart mass was unchanged in adult animals exposed to 7 days of actual microgravity (PF 1.33 +/- .03 g; FL 1.32 +/- 0.02 g; SIM 1.28 +/- 0.04 g; VIV 1.35 +/- 0.04 g). Similarly, heart mass was unaltered with hin~limb unloading (CON 1.40 +/- 0.04 g; 7HU 1.35 +/- 0.06 g; 28HU 1.42 +/- 0.03 g). Hindlimb unloading also had no effect on myocardial contractility (CON 8055 +/- 385 mmHg/sec; 28HU 8545 +/- 755 mmHg/sec). These data suggest that cardiac atrophy does not occur following short-term exposure to microgravity, and that neither short- nor long-term simulated microgravity alter cardiac mass or function.

Ray, Chester H.↗

Estimation of diastolic intraventricular pressure gradients by Doppler M-mode echocardiography

Previous studies have shown that small intraventricular pressure gradients (IVPG) are important for efficient filling of the left ventricle (LV) and as a sensitive marker for ischemia. Unfortunately, there has previously been no way of measuring these noninvasively, severely limiting their research and clinical utility. Color Doppler M-mode (CMM) echocardiography provides a spatiotemporal velocity distribution along the inflow tract throughout diastole, which we hypothesized would allow direct estimation of IVPG by using the Euler equation. Digital CMM images, obtained simultaneously with intracardiac pressure waveforms in six dogs, were processed by numerical differentiation for the Euler equation, then integrated to estimate IVPG and the total (left atrial to left ventricular apex) pressure drop. CMM-derived estimates agreed well with invasive measurements (IVPG: y = 0.87x + 0.22, r = 0.96, P < 0.001, standard error of the estimate = 0.35 mmHg). Quantitative processing of CMM data allows accurate estimation of IVPG and tracking of changes induced by beta-adrenergic stimulation. This novel approach provides unique information on LV filling dynamics in an entirely noninvasive way that has previously not been available for assessment of diastolic filling and function.

Non-NASA Center↗

Effect of Head-Down Bed Rest and Artificial Gravity Countermeasure on Cardiac Autonomic and Advanced Electrocardiographic Function

To study the effects of 21 days of head-down bed rest (HDBR), with versus without an artificial gravity (AG) countermeasure, on cardiac autonomic and advanced electrocardiographic function. Fourteen healthy men participated in the study: seven experienced 21 days of HDBR alone ("HDBR controls") and seven the same degree and duration of HDBR but with approximately 1hr daily short-arm centrifugation as an AG countermeasure ("AG-treated"). Five minute supine high-fidelity 12-lead ECGs were obtained in all subjects: 1) 4 days before HDBR; 2) on the last day of HDBR; and 3) 7 days after HDBR. Besides conventional 12-lead ECG intervals and voltages, all of the following advanced ECG parameters were studied: 1) both stochastic (time and frequency domain) and deterministic heart rate variability (HRV); 2) beat-to-beat QT interval variability (QTV); 3) T-wave morphology, including signal-averaged T-wave residua (TWR) and principal component analysis ratios; 4) other SAECG-related parameters including high frequency QRS ECG and late potentials; and 5) several advanced ECG estimates of left ventricular (LV) mass. The most important results by repeated measures ANOVA were that: 1) Heart rates, Bazett-corrected QTc intervals, TWR, LF/HF power and the alpha 1 of HRV were significantly increased in both groups (i.e., by HDBR), but with no relevant HDBR*group differences; 2) All purely "vagally-mediated" parameters of HRV (e.g., RMSSD, HF power, Poincare SD1, etc.), PR intervals, and also several parameters of LV mass (Cornell and Sokolow-Lyon voltages, spatial ventricular activation times, ventricular gradients) were all significantly decreased in both groups (i.e., by HDBR), but again with no relevant HDBR*group differences); 3) All "generalized" or "vagal plus sympathetic" parameters of stochastic HRV (i.e., SDNN, total power, LF power) were significantly more decreased in the AG-treated group than in the HDBR-only group (i.e., here there was a relevant HDBR*group difference); and 4) QTV index was also significantly more changed (increased) in the AG-treated group than in the HDBR-only group, although this was clearly due to a greater decrease in generalized HRV and not to a greater increase in QTV proper because there was no relevant HDBR*group effect for either the SDNN or the RMSSD of QTV. Brief daily AG treatment by short-arm centrifuge during each of 21 days of HDBR does not appear to protect against HDBR-related losses of cardiac autonomic function or of LV mass as estimated by ECG.

Schlegel, T. T.↗

Bursting into space: alterations of sympathetic control by space travel

AIM: Astronauts return to Earth with reduced red cell masses and hypovolaemia. Not surprisingly, when they stand, their heart rates may speed inordinately, their blood pressures may fall, and some may experience frank syncope. We studied autonomic function in six male astronauts (average +/- SEM age: 40 +/- 2 years) before, during, and after the 16-day Neurolab space shuttle mission. METHOD: We recorded electrocardiograms, finger photoplethysmographic arterial pressures, respiration, peroneal nerve muscle sympathetic activity, plasma noradrenaline and noradrenaline kinetics, and cardiac output, and we calculated stroke volume and total peripheral resistance. We perturbed autonomic function before and during spaceflight with graded Valsalva manoeuvres and lower body suction, and before and after the mission with passive upright tilt. RESULTS: In-flight baseline sympathetic nerve activity was increased above pre-flight levels (by 10-33%) in three subjects, in whom noradrenaline spillover and clearance also were increased. Valsalva straining provoked greater reductions of arterial pressure, and proportionally greater sympathetic responses in space than on Earth. Lower body suction elicited greater increases of sympathetic nerve activity, plasma noradrenaline, and noradrenaline spillover in space than on Earth. After the Neurolab mission, left ventricular stroke volume was lower and heart rate was higher during tilt, than before spaceflight. No astronaut experienced orthostatic hypotension or pre-syncope during 10 min of post-flight tilting. CONCLUSION: We conclude that baseline sympathetic outflow, however measured, is higher in space than on earth, and that augmented sympathetic nerve responses to Valsalva straining, lower body suction, and post-flight upright tilt represent normal adjustments to greater haemodynamic stresses associated with hypovolaemia.

NASA Program Biomedical Research and Countermeasur↗

Cardiac chamber volumes by echocardiography using a new mathematical method: A promising technique for zero-G use

Accurate, reproducible, and non-invasive means for ventricular volume determination are needed for evaluating cardiovascular function zero-gravity. Current echocardiographic methods, particularly for the right ventricle, suffer from a large standard error. A new mathematical approach, recently described by Watanabe et al., was tested on 1 normal formalin-fixed human hearts suspended in a mineral oil bath. Volumes are estimated from multiple two-dimensional echocardiographic views recorded from a single point at sequential angles. The product of sectional cavity area and center of mass for each view summed over the range of angles (using a trapezoidal rule) gives volume. Multiple (8-14) short axis right ventricle and left ventricle views at 5.0 deg intervals were videotaped. The images were digitized by two independent observers (leading-edge to leading-edge technique) and analyzed using a graphics tablet and microcomputer. Actual volumes were determined by filling the chambers with water. These data were compared to the mean of the two echo measurements.

Buckey, J. C.↗

Cytoskeletal role in the transition from compensated to decompensated hypertrophy during adult canine left ventricular pressure overloading

Increased microtubule density causes cardiocyte contractile dysfunction in right ventricular (RV) pressure-overload hypertrophy, and these linked phenotypic and contractile abnormalities persist and progress during the transition to failure. Although more severe in cells from failing than hypertrophied RVs, the mechanical defects are normalized in each case by microtubule depolymerization. To define the role of increased microtubule density in left ventricular (LV) pressure-overload hypertrophy and failure, in a given LV we examined ventricular mechanics, sarcomere mechanics, and free tubulin and microtubule levels in control dogs and in dogs with aortic stenosis both with LV hypertrophy alone and with initially compensated hypertrophy that had progressed to LV muscle failure. In comparing initial values with those at study 8 weeks later, dogs with hypertrophy alone had a very substantial increase in LV mass but preservation of a normal ejection fraction and mean systolic wall stress. Dogs with hypertrophy and associated failure had a substantial but lesser increase in LV mass and a reduction in ejection fraction, as well as a marked increase in mean systolic wall stress. Cardiocyte contractile function was equivalent, and unaffected by microtubule depolymerization, in cells from control LVs and those with compensated hypertrophy. In contrast, cardiocyte contractile function in cells from failing LVs was quite depressed but was normalized by microtubule depolymerization. Microtubules were increased only in failing LVs. These contractile and cytoskeletal changes, when assayed longitudinally in a given dog by biopsy, appeared in failing ventricles only when wall stress began to increase and function began to decrease. Thus, the microtubule-based cardiocyte contractile dysfunction characteristic of pressure-hypertrophied myocardium, originally described in the RV, obtains equally in the LV but is shown here to have a specific association with increased wall stress.

Non-NASA Center↗

Comparison of Echocardiographic Measurements Before and After Short and Long Duration Spaceflight

Previous echocardiography studies in astronauts before and after short duration (4 - 17 days) missions have demonstrated a decrease in resting left ventricular (LV) stroke volume (SV), but maintained ejection fraction (EF) and cardiac output. Similar studies before and after long duration (129 - 144 days) spaceflight have been rare and their overall results equivocal. The purpose of this work was to compare the echocardiographic measurements (M-mode, 2-D and Doppler) from short duration (n = 13) and long duration (n = 4) crewmembers. Compared to short duration astronauts, long duration crewmembers had a significantly greater percent decrease in EF (+6+/-0.02 vs.-10.5+/-0.03, p = 0.005) and percent fractional shortening (+7+/-0.03 vs. -11+/-0.07, p = 0.0 15), and an increase in LV end systolic volume (-12+/-0.06 vs. +39+/-0.24, p = 0.011). These data suggest a reduction in cardiac function that relates to mission duration. As the changes in blood pressure and circulating blood volume (9% - 12%) are reported to be similar after short and long duration flights, the drop in EF after longer spaceflights is likely due to a decrease in cardiac function rather than altered blood volume.

Fritsch-Yelle, Janice M.↗

Echocardiographic evaluation of Space Shuttle crewmembers

Echocardiographic measurements of left ventricular volume were obtained from 17 members of four Space Shuttle crews before and after 5- to 8-day space flights. Measurements obtained 1 h after landing indicated increases in the heart rate (HR), mean arterial pressure, and systemic vascular resistance values. On the other hand, the end-diastolic volume index (EDVI) fell 17 ml/sq m, and the stroke volume index (SVI) fell 15 ml/sq m. Measurements taken 1-2 weeks later demonstrated that the HR values returned to normal, but the EDVI and SVI values remained significantly below preflight levels, despite the ability of the subjects to ambulate and exercise. The results indicate that a space flight induces significant changes in heart volume affecting the left-ventricle function. It is suggested that the prolonged recovery period is related to the high level of aerobic conditioning in these subjects.

Bungo, M. W.↗

Molecular basis of force-pCa relation in MYL2 cardiomyopathy mice: Role of the super-relaxed state of myosin

Here, in this study, we investigated the role of the super-relaxed (SRX) state of myosin in the structure–function relationship of sarcomeres in the hearts of mouse models of cardiomyopathy-bearing mutations in the human ventricular regulatory light chain (RLC, MYL2 gene). Skinned papillary muscles from hypertrophic (HCM–D166V) and dilated (DCM–D94A) cardiomyopathy models were subjected to small-angle X-ray diffraction simultaneously with isometric force measurements to obtain the interfilament lattice spacing and equatorial intensity ratios (I 11 /I 10 ) together with the force-pCa relationship over a full range of [Ca 2+ ] and at a sarcomere length of 2.1 μm. In parallel, we studied the effect of mutations on the ATP-dependent myosin energetic states. Compared with wild-type (WT) and DCM–D94A mice, HCM–D166V significantly increased the Ca 2+ sensitivity of force and left shifted the I 11 /I 10 -pCa relationship, indicating an apparent movement of HCM–D166V cross-bridges closer to actin-containing thin filaments, thereby allowing for their premature Ca 2+ activation. The HCM–D166V model also disrupted the SRX state and promoted an SRX-to-DRX (super-relaxed to disordered relaxed) transition that correlated with an HCM-linked phenotype of hypercontractility. While this dysregulation of SRX ↔ DRX equilibrium was consistent with repositioning of myosin motors closer to the thin filaments and with increased force-pCa dependence for HCM–D166V, the DCM–D94A model favored the energy-conserving SRX state, but the structure/function–pCa data were similar to WT. Our results suggest that the mutation-induced redistribution of myosin energetic states is one of the key mechanisms contributing to the development of complex clinical phenotypes associated with human HCM–D166V and DCM–D94A mutations.

59 BASIC BIOLOGICAL SCIENCES↗

Risk of Cardiac Rhythm Problems During Spaceflight

NASA has concerns regarding the incidence and clinical significance of cardiac arrhythmias that could occur during long-term exposure to the spaceflight environment, such as on the International Space Station (ISS) or during a prolonged (e.g., up to 3 years) sojourn to Mars or on the Moon. There have been some anecdotal reports and a few documented cases of cardiac arrhythmias in space, including one documented episode of non-sustained ventricular tachycardia. The potential catastrophic nature of a sudden cardiac death in the remote space environment has led to concerns from the early days of the space program that spaceflight might be arrhythmogenic. Indeed, there are known and well-defined changes in the cardiovascular system with spaceflight: a) plasma volume is reduced, b) left ventricular mass is decreased, and c) the autonomic nervous system adapts to the weightless environment. Combined, these physiologic adaptations suggest that changes in cardiac structure and neuro-humoral environment during spaceflight could alter electrical conduction, although the evidence supporting this contention consists mostly of minor changes in QT interval (the time between the start of the Q wave and the end of the T wave on an electrocardiogram tracing) in a small number of astronauts after long-duration spaceflight. Concurrent with efforts by NASA Medical Operations to refine and improve screening techniques relevant to arrhythmias and cardiovascular disease, as NASA enters the era of exploration-class missions it will be critical to determine with the highest degree of certainty whether spaceflight by itself alters cardiac structure and function sufficiently to increase the risk of arrhythmias.

Lee, Stuart M. C.↗

Estimation of left ventricular operating stiffness from Doppler early filling deceleration time in humans

Shortened early transmitral deceleration times (E(DT)) have been qualitatively associated with increased filling pressure and reduced survival in patients with cardiac disease and increased left ventricular operating stiffness (K(LV)). An equation relating K(LV) quantitatively to E(DT) has previously been described in a canine model but not in humans. During several varying hemodynamic conditions, we studied 18 patients undergoing open-heart surgery. Transesophageal echocardiographic two-dimensional volumes and Doppler flows were combined with high-fidelity left atrial (LA) and left ventricular (LV) pressures to determine K(LV). From digitized Doppler recordings, E(DT) was measured and compared against changes in LV and LA diastolic volumes and pressures. E(DT) (180 +/- 39 ms) was inversely associated with LV end-diastolic pressures (r = -0.56, P = 0.004) and net atrioventricular stiffness (r = -0.55, P = 0.006) but had its strongest association with K(LV) (r = -0.81, P < 0.001). K(LV) was predicted assuming a nonrestrictive orifice (K(nonrest)) from E(DT) as K(nonrest) = (0.07/E(DT))(2) with K(LV) = 1.01 K(nonrest) - 0.02; r = 0.86, P < 0.001, DeltaK (K(nonrest) - K(LV)) = 0.02 +/- 0.06 mm Hg/ml. In adults with cardiac disease, E(DT) provides an accurate estimate of LV operating stiffness and supports its application as a practical noninvasive index in the evaluation of diastolic function.

Non-NASA Center↗

Ventricular filling slows epicardial conduction and increases action potential duration in an optical mapping study of the isolated rabbit heart

INTRODUCTION: Mechanical stimulation can induce electrophysiologic changes in cardiac myocytes, but how mechanoelectric feedback in the intact heart affects action potential propagation remains unclear. METHODS AND RESULTS: Changes in action potential propagation and repolarization with increased left ventricular end-diastolic pressure from 0 to 30 mmHg were investigated using optical mapping in isolated perfused rabbit hearts. With respect to 0 mmHg, epicardial strain at 30 mmHg in the anterior left ventricle averaged 0.040 +/- 0.004 in the muscle fiber direction and 0.032 +/- 0.006 in the cross-fiber direction. An increase in ventricular loading increased average epicardial activation time by 25%+/- 3% (P < 0.0001) and correspondingly decreased average apparent surface conduction velocity by 16%+/- 7% (P = 0.007). Ventricular loading did not significantly alter action potential duration at 20% repolarization (APD20) but did at 80% repolarization (APD80), from 179 +/- 7 msec to 207 +/- 5 msec (P < 0.0001). The dispersion of APD20 was decreased with loading from 19 +/- 2 msec to 13 +/- 2 msec (P = 0.024), whereas the dispersion of APD80 was not significantly changed. These electrophysiologic changes with ventricular loading were not affected by the nonspecific stretch-activated channel blocker streptomycin (200 microM) and were not attributable to changes in myocardial perfusion or the presence of an electromechanical decoupling agent (butanedione monoxime) during optical mapping. CONCLUSION: Acute loading of the left ventricle of the isolated rabbit heart decreased apparent epicardial conduction velocity and increased action potential duration by a load-dependent mechanism that may not involve stretch-activated channels.

NASA Program Biomedical Research and Countermeasur↗

Contrast and harmonic imaging improves accuracy and efficiency of novice readers for dobutamine stress echocardiography

BACKGROUND: Newer contrast agents as well as tissue harmonic imaging enhance left ventricular (LV) endocardial border delineation, and therefore, improve LV wall-motion analysis. Interpretation of dobutamine stress echocardiography is observer-dependent and requires experience. This study was performed to evaluate whether these new imaging modalities would improve endocardial visualization and enhance accuracy and efficiency of the inexperienced reader interpreting dobutamine stress echocardiography. METHODS AND RESULTS: Twenty-nine consecutive patients with known or suspected coronary artery disease underwent dobutamine stress echocardiography. Both fundamental (2.5 MHZ) and harmonic (1.7 and 3.5 MHZ) mode images were obtained in four standard views at rest and at peak stress during a standard dobutamine infusion stress protocol. Following the noncontrast images, Optison was administered intravenously in bolus (0.5-3.0 ml), and fundamental and harmonic images were obtained. The dobutamine echocardiography studies were reviewed by one experienced and one inexperienced echocardiographer. LV segments were graded for image quality and function. Time for interpretation also was recorded. Contrast with harmonic imaging improved the diagnostic concordance of the novice reader to the expert reader by 7.1%, 7.5%, and 12.6% (P < 0.001) as compared with harmonic imaging, fundamental imaging, and fundamental imaging with contrast, respectively. For the novice reader, reading time was reduced by 47%, 55%, and 58% (P < 0.005) as compared with the time needed for fundamental, fundamental contrast, and harmonic modes, respectively. With harmonic imaging, the image quality score was 4.6% higher (P < 0.001) than for fundamental imaging. Image quality scores were not significantly different for noncontrast and contrast images. CONCLUSION: Harmonic imaging with contrast significantly improves the accuracy and efficiency of the novice dobutamine stress echocardiography reader. The use of harmonic imaging reduces the frequency of nondiagnostic wall segments.

Non-NASA Center↗

Noninvasive assessment of left atrial maximum dP/dt by a combination of transmitral and pulmonary venous flow

OBJECTIVES: The study assessed whether hemodynamic parameters of left atrial (LA) systolic function could be estimated noninvasively using Doppler echocardiography. BACKGROUND: Left atrial systolic function is an important aspect of cardiac function. Doppler echocardiography can measure changes in LA volume, but has not been shown to relate to hemodynamic parameters such as the maximal value of the first derivative of the pressure (LA dP/dt(max)). METHODS: Eighteen patients in sinus rhythm were studied immediately before and after open heart surgery using simultaneous LA pressure measurements and intraoperative transesophageal echocardiography. Left atrial pressure was measured with a micromanometer catheter, and LA dP/dt(max) during atrial contraction was obtained. Transmitral and pulmonary venous flow were recorded by pulsed Doppler echocardiography. Peak velocity, and mean acceleration and deceleration, and the time-velocity integral of each flow during atrial contraction was measured. The initial eight patients served as the study group to derive a multilinear regression equation to estimate LA dP/dt(max) from Doppler parameters, and the latter 10 patients served as the test group to validate the equation. A previously validated numeric model was used to confirm these results. RESULTS: In the study group, LA dP/dt(max) showed a linear relation with LA pressure before atrial contraction (r = 0.80, p < 0.005), confirming the presence of the Frank-Starling mechanism in the LA. Among transmitral flow parameters, mean acceleration showed the strongest correlation with LA dP/dt(max) (r = 0.78, p < 0.001). Among pulmonary venous flow parameters, no single parameter was sufficient to estimate LA dP/dt(max) with an r2 > 0.30. By stepwise and multiple linear regression analysis, LA dP/dt(max) was best described as follows: LA dP/dt(max) = 0.1 M-AC +/- 1.8 P-V - 4.1; r = 0.88, p < 0.0001, where M-AC is the mean acceleration of transmitral flow and P-V is the peak velocity of pulmonary venous flow during atrial contraction. This equation was tested in the latter 10 patients of the test group. Predicted and measured LA dP/dt(max) correlated well (r = 0.90, p < 0.0001). Numerical simulation verified that this relationship held across a wide range of atrial elastance, ventricular relaxation and systolic function, with LA dP/dt(max) predicted by the above equation with r = 0.94. CONCLUSIONS: A combination of transmitral and pulmonary venous flow parameters can provide a hemodynamic assessment of LA systolic function.

NASA Discipline Cardiopulmonary↗

Automated Cardiovascular Pathology Assessment using Semantic Segmentation and Ensemble Learning

Cardiac magnetic resonance imaging provides high spatial resolution, enabling improved extraction of important functional and morphological features for cardiovascular disease staging. Segmentation of ventricular cavities and myocardium in cardiac cine sequencing provides a basis to quantify cardiac measures such as ejection fraction. A method is presented that curtails the expense and observer bias of manual cardiac evaluation by combining semantic segmentation and disease classification into a fully automatic processing pipeline. The initial processing element consists of a robust dilated convolutional neural network architecture for voxel-wise segmentation of the myocardium and ventricular cavities. The resulting comprehensive volumetric feature matrix captures diagnostic clinical procedure data and is utilized by the final processing element to model a cardiac pathology classifier. Our approach evaluated anonymized cardiac images from a training data set of 100 patients (4 pathology groups, 1 healthy group, 20 patients per group) examined at the University Hospital of Dijon. The top average Dice index scores achieved were 0.940, 0.886, 0.849 for structure segmentation of the left ventricle (LV), myocardium and right ventricle (RV) respectively. A 5-ary pathology classification accuracy of 90% was recorded on an independent test set using the trained model. Performance results demonstrate potential for advanced machine learning methods to deliver accurate, efficient and reproducible cardiac pathological assessment.

Semantic Segmentation↗