Search NASA⌕ Search

SEARCH · Search NASA

Results for “Verification Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A PPE Use Case on Configuration Management Approach for MBSE

Systems engineers worldwide have been working to implement Model-based Systems Engineering (MBSE) environments, tools, and methodologies. MBSE is a formalized application of modeling to support systems engineering, including requirements, design, analysis, verification, and validation activities over the project’s lifecycle[1]; MBSE captures the system data into a digital environment. Significant benefits of MBSE includes a reduction in the time in performing systems engineering activities and an improvement higher fidelity data production. As more Systems Engineers are using MBSE, the models it produces are becoming the source of truth for Systems Engineering artifacts. As we move towards using these models as the source of truth, a more rigorous Configuration Management (CM) infrastructure is needed. Many of the MBSE tools provide CM options but utilizing them efficiently and effectively can be challenging. More rigorous methods and tools are needed to assist with keeping track of changes in the model, making sure inadvertent changes to baseline data did not occur, visibility of changes in the different model versions, and the impacts of changes to the models. System engineers and configuration management personnel from the Power and Propulsion Element (PPE) project at NASA Glenn Research Center have been working to develop a modeling construct that allows models to be the source of truth and maintain a configuration managed baseline. This paper presents a process that leverages the existing CM tools and describes how PPE used this process to manage changes more rigorously. It will describe the process behind building the model architecture that utilizes the MBSE tool capabilities and the configuration management process. It will contain some of the advantages and disadvantages of the architecture that the PPE project had settled upon utilizing, as well as some enhanced capabilities that the PPE MBSE team has developed.

MBSE↗

Camera Simulation for the Perseverance Rover’s Lander Vision System

On February 18, 2021, the Perseverance Rover safely landed on Mars at Jezero Crater. Part of the successful landing was due to the Lander Vision System (LVS), which takes descent images from the LVS Camera (LCAM) and IMU measurements and estimates the lander position relative to a map of the Jezero landing site. The LVS Simulation LCAM (LVSS LCAM) model is an image rendering program developed to test the LVS in a variety of scenarios to ensure performance amid uncertainty. The LVSS LCAM model includes a pointing misalignment model, an exposure timing model, shadowing, a terrain reflectance model, atmospheric attenuation from dust, and sensor effects. This model was used for performance analysis, verification, and validation of the LVS algorithms in a Mars-like simulation prior to landing. This paper describes the LVSS LCAM rendering algorithm and compares flight images from LVS operation during the Perseverance landing with their rendered counterparts.

Zheng, Jason↗

Unconservatism of Linear-Elastic Fracture Mechanics (LEFM) Analysis Post Autofrettage

The scope of the NASA Engineering and Safety Center (NESC) Unconservatism of Linear-Elastic Fracture Mechanics (LEFM) Analysis Post Autofrettage assessment was to evaluate the influence of the elastic-plastic autofrettage cycle on elastic cycles post autofrettage and generate data to support damage tolerance life analysis verification approach. The decision to include an elastic-plastic autofrettage cycle is informed by other factors beyond damage tolerance, including manufacturing and fatigue crack initiation. The results of the NESC assessment are contained in this report.

Linear-Elastic Fracture Mechanics↗

Goddard high resolution spectrograph science verification and data analysis

The data analysis performed was to support the Orbital Verification (OV) and Science Verification (SV) of the GHRS was in the areas of the Digicon detector's performance and stability, wavelength calibration, and geomagnetic induced image motion. The results of the analyses are briefly described. Detailed results are given in the form of attachments. Specialized software was developed for the analyses. Calibration files were formatted according to the specifications in a Space Telescope Science report. IRAS images were restored of the Large Magellanic Cloud using a blocked iterative algorithm. The algorithm works with the raw data scans without regridding or interpolating the data on an equally spaced image grid.

Source record↗

Verification of thermal analysis codes for modeling solid rocket nozzles

One of the objectives of the Solid Propulsion Integrity Program (SPIP) at Marshall Space Flight Center (MSFC) is development of thermal analysis codes capable of accurately predicting the temperature field, pore pressure field and the surface recession experienced by decomposing polymers which are used as thermal barriers in solid rocket nozzles. The objective of this study is to provide means for verifications of thermal analysis codes developed for modeling of flow and heat transfer in solid rocket nozzles. In order to meet the stated objective, a test facility was designed and constructed for measurement of the transient temperature field in a sample composite subjected to a constant heat flux boundary condition. The heating was provided via a steel thin-foil with a thickness of 0.025 mm. The designed electrical circuit can provide a heating rate of 1800 W. The heater was sandwiched between two identical samples, and thus ensure equal power distribution between them. The samples were fitted with Type K thermocouples, and the exact location of the thermocouples were determined via X-rays. The experiments were modeled via a one-dimensional code (UT1D) as a conduction and phase change heat transfer process. Since the pyrolysis gas flow was in the direction normal to the heat flow, the numerical model could not account for the convection cooling effect of the pyrolysis gas flow. Therefore, the predicted values in the decomposition zone are considered to be an upper estimate of the temperature. From the analysis of the experimental and the numerical results the following are concluded: (1) The virgin and char specific heat data for FM 5055 as reported by SoRI can not be used to obtain any reasonable agreement between the measured temperatures and the predictions. However, use of virgin and char specific heat data given in Acurex report produced good agreement for most of the measured temperatures. (2) Constant heat flux heating process can produce a much higher heating rate than the radiative heating process. The results show that heating rates of 125 C/s (225 F/s) can be achieved. (3) The electrical resistance of the FM 5055 samples were about 150 Omega in the virgin state, and decreased to about 35 Omega when charred. A reliable scheme must be developed to electrically insulate the composite from the heater foil in order to prevent any current leakage into the sample which can result in volumetric heating of the char zone of the composite.

Keyhani, M.↗

MESA: Message-Based System Analysis Using Runtime Verification

In this paper, we present a novel approach and framework for run-time verication of large, safety critical messaging systems. This work was motivated by verifying the System Wide Information Management (SWIM) project of the Federal Aviation Administration (FAA). SWIM provides live air traffic, site and weather data streams for the whole National Airspace System (NAS), which can easily amount to several hundred messages per second. Such safety critical systems cannot be instrumented, therefore, verification and monitoring has to happen using a nonintrusive approach, by connecting to a variety of network interfaces. Due to a large number of potential properties to check, the verification framework needs to support efficient formulation of properties with a suitable Domain Specific Language (DSL). Our approach is to utilize a distributed system that is geared towards connectivity and scalability and interface it at the message queue level to a powerful verification engine. We implemented our approach in the tool called MESA: Message-Based System Analysis, which leverages the open source projects RACE (Runtime for Airspace Concept Evaluation) and TraceContract. RACE is a platform for instantiating and running highly concurrent and distributed systems and enables connectivity to SWIM and scalability. TraceContract is a runtime verication tool that allows for checking traces against properties specified in a powerful DSL. We applied our approach to verify a SWIM service against several requirements.We found errors such as duplicate and out-of-order messages.

Message-based System↗

ORNL Report of Analysis for the Verification of NRMP CRM U030A

In support of the Certified Reference Material (CRM) program managed by the Nuclear Reference Material Program (NRMP), the Material Signatures and Isotopic Standards (MSIS) group of Oak Ridge National Laboratory (ORNL) was asked to prepare a set of CRM U030A units for use as standards for isotopic analysis using multicollector thermal ionization mass spectrometry (TIMS) and inductively coupled plasma mass spectrometry (ICP-MS) instruments. This report documents the results of the verification measurements performed on three randomly selected units by the MSIS group’s ISO/IEC 17025:2017 accredited operating procedure CSD-AM-CIMS-IN20, Determination of Uranium and Plutonium Isotopic Composition using Thermal Ionization Mass Spectrometry [1], and in accordance with the quality assurance plan as described in QAP-X-96-CSD/RML-001, Nuclear Analytical Chemistry Laboratory Section Quality Assurance Plan [2].

Mathew, Kattathu [Oak Ridge National Laboratory (O↗

Design, analysis, and test verification of advanced encapsulation systems

Design sensitivities are established for the development of photovoltaic module criteria and the definition of needed research tasks. The program consists of three phases. In Phase I, analytical models were developed to perform optical, thermal, electrical, and structural analyses on candidate encapsulation systems. From these analyses several candidate systems will be selected for qualification testing during Phase II. Additionally, during Phase II, test specimens of various types will be constructed and tested to determine the validity of the analysis methodology developed in Phase I. In Phse III, a finalized optimum design based on knowledge gained in Phase I and II will be developed. All verification testing was completed during this period. Preliminary results and observations are discussed. Descriptions of the thermal, thermal structural, and structural deflection test setups are included.

Mardesich, N.↗

Development and verification of global/local analysis techniques for laminated composites

A two-dimensional to three-dimensional global/local finite element approach was developed, verified, and applied to a laminated composite plate of finite width and length containing a central circular hole. The resulting stress fields for axial compression loads were examined for several symmetric stacking sequences and hole sizes. Verification was based on comparison of the displacements and the stress fields with those accepted trends from previous free edge investigations and a complete three-dimensional finite element solution of the plate. The laminates in the compression study included symmetric cross-ply, angle-ply and quasi-isotropic stacking sequences. The entire plate was selected as the global model and analyzed with two-dimensional finite elements. Displacements along a region identified as the global/local interface were applied in a kinematically consistent fashion to independent three-dimensional local models. Local areas of interest in the plate included a portion of the straight free edge near the hole, and the immediate area around the hole. Interlaminar stress results obtained from the global/local analyses compares well with previously reported trends, and some new conclusions about interlaminar stress fields in plates with different laminate orientations and hole sizes are presented for compressive loading. The effectiveness of the global/local procedure in reducing the computational effort required to solve these problems is clearly demonstrated through examination of the computer time required to formulate and solve the linear, static system of equations which result for the global and local analyses to those required for a complete three-dimensional formulation for a cross-ply laminate. Specific processors used during the analyses are described in general terms. The application of this global/local technique is not limited software system, and was developed and described in as general a manner as possible.

Thompson, Danniella Muheim↗

Design, analysis and test verification of advanced encapsulation systems

An analytical methodology for advanced encapsulation designs was developed. From these methods design sensitivities are established for the development of photovoltaic module criteria and the definition of needed research tasks. Analytical models were developed to perform optical, thermal, electrical and analyses on candidate encapsulation systems. From these analyses several candidate systems were selected for qualification testing. Additionally, test specimens of various types are constructed and tested to determine the validity of the analysis methodology developed. Identified deficiencies and/or discrepancies between analytical models and relevant test data are corrected. Prediction capability of analytical models is improved. Encapsulation engineering generalities, principles, and design aids for photovoltaic module designers is generated.

Garcia, A., III↗

A Computational Framework to Control Verification and Robustness Analysis

This paper presents a methodology for evaluating the robustness of a controller based on its ability to satisfy the design requirements. The framework proposed is generic since it allows for high-fidelity models, arbitrary control structures and arbitrary functional dependencies between the requirements and the uncertain parameters. The cornerstone of this contribution is the ability to bound the region of the uncertain parameter space where the degradation in closed-loop performance remains acceptable. The size of this bounding set, whose geometry can be prescribed according to deterministic or probabilistic uncertainty models, is a measure of robustness. The robustness metrics proposed herein are the parametric safety margin, the reliability index, the failure probability and upper bounds to this probability. The performance observed at the control verification setting, where the assumptions and approximations used for control design may no longer hold, will fully determine the proposed control assessment.

Crespo, Luis G.↗

Cross-Code Verification of Neutronics Analysis Tools at INL Applied for 238 Pu Production in the Advanced Test Reactor

Here, analyses are completed for experiments prior to experiment irradiation in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). Various codes are used to qualify all experiments planned for insertion in the reactor, thereby ensuring that all safety and programmatic requirements are satisfied preirradiation. Among the common experiment analysis tools at INL are MCNP5 coupled to ORIGEN2 (MOPY) and MC21. MOPY uses MCNP5 for transport calculations along with calculations for fluxes and select reaction rates, and then ORIGEN2 handles the step-by-step and postirradiation depletion. MC21 handles all in-reactor transport and step-by-step, during-irradiation, depletion calculations, and then ORIGEN (SCALE 6.2.3) is used for decay and dose calculations postirradiation. The MOPY results, along with those obtained via two variations of the MC21 model, were compared in terms of 238 Pu production in the ATR’s H10 position. For the MOPY model, the MC21 model utilizing the HELIOS-based fission product (FP) library, and the MC21 model utilizing the expanded 1300 FP library, the during-cycle irradiation in-core heating results were sufficiently equivalent; however, the MOPY model and the MC21 model with the HELIOS library showed some differences relating to the respective FP libraries. Ultimately, the MC21 model with a 1300 FP library produced the most consistent results throughout the cycle, whereas the MC21 model that utilized the (smaller) HELIOS library was able to handle during-irradiation analysis but lacked certain short-lived FPs that significantly contributed to the total decay heat at shutdown. MOPY, on the other hand, was found to overpredict fission gas production, as a result of limitations in the ORIGEN2 code.

ATR↗

Design, analysis, and test verification of advanced encapsulation system

Procurement of 4 in x 4 in polycrystalline solar cells were proceeded with some delays. A total of 1200 cells were procured for use in both the verification testing and qualification testing. Additional thermal structural analyses were run and the data are presented. An outline of the verification testing is included with information on test specimen construction.

Garcia, A.↗

Design, analysis, and test verification of advanced encapsulation systems

Thermal, optical, structural, and electrical isolation analyses are decribed. Major factors in the design of terrestrial photovoltaic modules are discussed. Mechanical defects in the different layers of an encapsulation system, it was found, would strongly influence the minimum pottant thickness required for electrical isolation. Structural, optical, and electrical properties, a literature survey indicated, are hevily influenced by the presence of moisture. These items, identified as technology voids, are discussed. Analyses were based upon a 1.2 meter square module using 10.2 cm (4-inch) square cells placed 1.3 mm apart as shown in Figure 2-2. Sizing of the structural support member of a module was determined for a uniform, normal pressure load of 50 psf, corresponding to the pressure difference generated between the front and back surface of a module by a 100 mph wind. Thermal and optical calculations were performed for a wind velocity of 1 meter/sec parallel to the ground and for module tilt (relative to the local horizontal) of 37 deg. Placement of a module in a typical array field is illustrated.

Garcia, A.↗