Search NASA⌕ Search

SEARCH · Search NASA

Results for “Volatile collection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Molecular and Elemental Dust Analyzer (MEDA) for the comet rendezvous asteroid flyby mission

Comets are some to the most primitive bodies in the solar system and therefore should contain elemental, chemical, and isotopic records of the early history of the solar system. An opportunity to perform in situ analyses of a comet nucleus exists with the Comet Rendezvous Asteroid Flyby (CRAF) mission. An integrated gas chromatograph/X-ray fluorescence instrument (MEDA), being proposed for inclusion onboard the CRAF spacecraft, will measure the molecular and elemental constituents of collected dust grains and ices. The gas chromatograph, employing helium ionization detectors and three columns designed to separate light gases, polar gases, and hydrocarbons will measure the volatile compounds of the biogenic elements thermally released from collected dust grains. The sensitivity of the GC for compounds of interest is at the picogram level. X-ray fluorescence utilized cryogenically cooled Si(Li) solid state detectors of nominal 150 eV resolution at 5.9 keV. Based on laboratory work with carbonaceous meteorites, both the GC and XRF can perform meaningful analyses with a few micrograms of collected comet dust.

Ohara, B. J.↗

Components Refurbishment and Chemical Analysis Facility, SWMU #041 - Per- and Polyfluoroalkyl Substances Site Assessment Report Kennedy Space Center, Florida

This PFAS Site Assessment (SA) Report presents the activities and results associated with PFAS investigations at the Components Refurbishment and Chemical Analysis (CRCA) facility located at Kennedy Space Center (KSC), Florida. In 2022, CRCA was identified as an Area of Potential Concern because the facility stores several potential PFAS-containing chemicals. A groundwater sample collected from an onsite monitoring well detected PFOA and PFOS at concentrations greater than State of Florida provisional Groundwater Cleanup Target Levels (pGCTLs). PFAS SA activities were conducted between March 2022 and February 2024. During this timeframe, a total of 16 direct-push technology (DPT) locations and 82 discrete samples were collected from these locations, along with 90 monitoring well samples. The analytical data screening process focused on State of Florida pGCTLs and United States Environmental Protection Agency (USEPA) Regional Screening Level (RSLs) from November 2023 to evaluate the data. Analytical results identified PFOS, PFOA, and PFBA at concentrations exceeding their respective RSLs at each depth interval (shallow, intermediate, and deep). PFOS and PFOA had the largest footprint of RSL exceedances in each depth interval, but pGCTL exceedances were only observed at limited locations in the shallow and intermediate intervals. PFBA had the highest detections of any PFAS compound, with concentrations exceeding 180,000 nanograms per liter (ng/L), which is 100-times the RSL of 1,800 ng/L in the shallow and intermediate intervals and 10-times the RSL in the deep interval. The maximum PFBA detection was 841,000 ng/L at shallow monitoring well, MW0006. The PFAS SA also included samples collected from the onsite hydraulic containment system (HCS) which was installed to control and treat the onsite chlorinated volatile organic compound (CVOC) plume. Influent and effluent aqueous samples were collected monthly from the system. PFAS concentrations were relatively the same for both influent and effluent samples, indicating that while the HCS has been effective for CVOC treatment, it does not provide any additional treatment for PFAS compounds. Since the HCS has achieved its objectives, the system was shut down in December 2024. PFAS data gaps still exist, to include surface water and soil, which were not sampled during this SA. Soil sampling near the Chemical Process Area is recommended. Surface water and soil sampling at select stormwater outfalls is also recommended. Additionally, further groundwater sampling is recommended (DPT and monitoring well) in all depth intervals to delineate the extent of PFAS impacts at CRCA.

K Alex Murphy↗

JSC Stardust Curation Team

STARDUST, a NASA Discovery-class mission, is the first to return samples from a comet. Grains from comet Wild 2's coma-the gas and dust envelope that surrounds the nucleus-will be collected as well as interstellar dust. The mission which launched on February 7, 1999 will encounter the comet on January 10, 2004. As the spacecraft passes through the coma, a tray of silica aerogel will be exposed, and coma grains will impact there and become captured. Following the collection, the aerogel tray is closed for return to Earth in 2006. A dust impact mass spectrometer on board the STARDUST spacecraft will be used to gather spectra. of dust during the entire mission, including the coma passage. This instrument will be the best chance to obtain data on volatile grains, which will not be well-collected in the aerogel. The dust impact mass spectrometer will also be used to study the composition of interstellar grains. In the past 5 years, analysis of data from dust detectors aboard the Ulysses and Galileo spacecraft have revealed that there is a stream of interstellar dust flowing through our solar system. These grains will be captured during the cruise phase of the STARDUST mission, as the spacecraft travels toward the comet. The sample return capsule will parachute to Earth in February 2006, and will land in western Utah. Once on y the ground, the sample return capsule will be placed into a dry nitrogen environment and flown to the curation lab at JSC.

Zolensky, Michael E.↗

Atmospheric aerosol measurement problems

The present knowledge of the atmospheric aerosols is summarized briefly with respect to geographical distribution, time variations, optical properties, chemical nature, and natural and artificial sources. The measurement techniques for determining aerosol properties are summarized with the limitations and results from each. The problems resulting from variations in refractive index, shape, composition, volatile constituents, relative humidity and time from collection until measurement are described. Needed measurements on atmospheric aerosols are outlined with some of the latest methods for obtaining them, including the needs and goals of some world-wide programs.

Harris, F. S., Jr.↗

Hydrogen and carbon isotopic composition of volatiles in Nakhla: Implications for weathering on Mars

Gases were collected at 120, 200, 300, 415, and 600 and 850 C. Hydrogen yields for the 600 and 850 C aliquots were measured separately and then the gases were combined for isotopic analysis. CO2 samples collected at the two lowest temperature steps amounted to less than 0.5 mu mole and were not analyzed isotopically. Excluding the 120 C temperature step, the bulk delta D of the sample was + 187 percent. Delta D values increase from -91 percent in the 120 C step to +518 percent in the 315 to 850 C step. The hydrogen content is greatest in the 120 C step and is roughly constant in the 200, 300, and 415 C aliquots. Between 415 C and 850 C, the yield drops off considerably. From 850 C to 950 C, virtually no H2 and only minor CO2 (less than 1 mu mole) were extracted. Using the isotopic analysis from the 300, 415, 600, and 850 C temperature collections, the bulk delta C-13 sub (PDB) is 0.0 percent. The heaviest component (delta C-13 sub (PDB) of +29 percent) was collected between 300 and 415 C. The release of hydrogen at the low temperatures reported here is consistent with the breakdown of the phases that constitute the alteration product between approx. 250 and 650 C. Although not as high as the present Martian atmosphere, the high delta D values are consistent with a Martian origin for the meteorites in question.

Watson, L. L.↗

Preparation and Testing of Ice-Enriched Lunar Regolith Simulant for RESOLVE OVEN

The RESOLVE (Regolith and Environment Science and Oxygen and Lunar Volatile Extraction) project seeks to deploy a robotic ISRU lander at the lunar south pole to determine the accessibility of frozen ice and the resource potential at various locations. The OVEN (Oxygen and Volatiles Extraction Node) component will be used to heat samples to 150 C or higher in order to drive off ice and other volatiles, which will then be identified and measured. An ice volatilization system has been developed to specifically collect data on the extraction of water vapor from a sample. Testing of the system was begun in April of this year. This report addresses our current work to test the system in a relevant environment in this case, using simulants with up to 10wt% water ice at 76K, in reduced atmosphere.

Cooper, Bonnie↗

In situ extraction and analysis of volatiles and simple molecules in interplanetary dust particles, contaminants, and silica aerogel

Results are presented for the analyses of eight interplanetary dust particles (IDPs) for the volatile elements H, C, N, O, and S and their molecular species, as well as of the volatiles associated with contaminants (i.e., the compounds used during the collection and curation of IDPs), which were carried out using a laser microprobe interfaced with a quadrupole mass spectrometer. It was found that the volatile species from contaminants were always present in the spectra of IDPs. Despite the contamination problems, several indigenous molecular species could be identified, including OH, CO2 or C2H4, C and CS2, CO2 along with CO (possibly indicating the presence of carbonate), H2S, SO, COS, SO2, and CS2. In some cases, the sulfur components can be attributed to aerosols; however, in one of the IDPs, the presence of H2S, SO, COS, and SO2 indicates the possible presence of elemental sulfur.

Hartmetz, C. P.↗

Microwave AeroGel Volatile Collector (MAGVC) Aerogel and Microwave Radiation Study

The MAGVC is a volatile extraction system that uses microwave radiation to sublimate and collect water trapped in regolith on the lunar surface It is comprised of: - Microwave source (magnetron) - Aerogel-insulated chamber (depicted as a dome) - Volatile storage system (depicted as 4 tanks) - Autonomous operating system

Aerogel↗

Search for organic and volatile inorganic compounds in two surface samples from the Chryse Planitia region of Mars

Two surface samples collected from the Chryse Planitia region of Mars were heated to temperatures up to 500 C, and the volatiles that they evolved were analyzed with a gas chromatograph-mass spectrometer. Only water and carbon dioxide were detected. This implies that organic compounds have not accumulated to the extent that individual components could be detected at levels of a few parts per billion by weight in the samples. Proposed mechanisms for the accumulation and destruction of organic compounds are discussed in the light of this limit.

Biemann, K.↗

Investigating Bennu’s Volatile Accretion History Through Step-Heating N-Ne-Ar Analyses of Single Aggregate Particles

NASA’s OSIRIS-REx spacecraft delivered a sample from the carbonaceous asteroid (101955) Bennu to Earth on September 24, 2023. Since Bennu presumably accreted in the outer protoplanetary disk, beyond Jupiter’s orbit, the collected material is expected to be rich in highly volatile elements such as H, C, N, and noble gases—similar to Ivuna-type (CI) carbonaceous chondrites and material from asteroid (162173) Ryugu returned by JAXA’s Hayabusa2 spacecraft. This type of material may have contributed to the volatile inventory of Earth and the other terrestrial planets. Bulk CI chondrites record a narrow range of δ 15 N values (i.e., the permil difference from the atmospheric 15 N/ 14 N ratio), averaging between +42 and 49‰. In contrast, recent analyses at CRPG’s noble gas facility revealed that two pelletized Ryugu samples have lower δ 15 N values of +18.1 ± 0.9‰ and +19.5 ± 0.9‰. Together with the low measured N abundances, this observation suggests that Ryugu has lost a 15 N-rich, labile organic phase due to pervasive aqueous alteration. Subsequent high-resolution step-heating analyses of an additional Ryugu particle demonstrated that the δ 15 N value varies significantly during successive extraction steps (between +1.0 ± 1.0‰ and 65.8 ± 1.1‰); the variable N isotopic composition points to the presence of several isotopically distinct N-carrier phases in CI-type material. Here, we report preliminary N-Ne-Ar results obtained for individual particles from an aggregate Bennu sample using the Noblesse-HR (Nu Instruments) noble gas mass spectrometer at CRPG’s noble gas facility. In a companion abstract, we will present the noble gas (He, Ne, Ar, Kr, Xe) characteristics of other aggregate particles determined with a HELIX MC Plus. Whereas the abundance and isotopic composition of noble gases permit detection of various presolar phases and the so-called phase Q, as well as quantification of solar wind–derived and cosmogenic components, the abundance and isotopic composition of N are expected to provide further insights into the origin and evolution of N-bearing phases in carbonaceous asteroids.

E Füri↗

Degassing history of Mars from Martian atmosphere samples

A comparison of the abundances of Ar-40 and He-4 (radiogenic) in various terrestrial planetary atmospheres provides clues to the volcanic and tectonic histories of the planets while the amount of primordial noble gases in the planetary atmospheres provides clues to the quantities of volatile rich materials captured by each planet. The noble gas contents of Mars, Earth, and Venus clearly show that the absolute abundances of isotopes of gases are directly proportional to the amounts of degassed CO2 into the planetary atmosphere. Several basic geological units can be seen on the global geological map of Mars. The enormous size of volcanic and tectonic structures of Mars, despite its smaller size, provide invaluable clues to the degassing history of Mars. Therefore, the collection of samples of Martian atmosphere and soil volatiles is imperative to understand the origin and evolution of the atmosphere and its interaction with the Martian surface. Surface properties of Martian rocks, soils, breccias, and regolith and their chemistry are also generic to any discussion on the origin and evolution of the atmosphere of Mars. The differences in absolute abundances of gases in the planetary atmospheres are amenable to many alternative interpretations. These alternative interpretations can be tested by imposing additional constraints derived from the isotopic results of noble gases in the atmospheres of the planets.

Rao, A. S. P.↗

Volatile products from the interaction of KCl(g) with Cr2O3 and LaCrO3 in oxidizing environments

Cooled target collection techniques and high pressure mass spectrometric sampling were used to measure the relative rates of oxidative vaporization and to identify the volatile products emanating from samples of chromia and Mg-doped lanthanum chromite. The materials were exposed to partial pressures of KCl with and without H2O in one atmosphere of slowly flowing oxygen at elevated temperatures. Chromia and fresh samples of lanthanum chromite exhibited enhanced rates of oxidative vaporization upon exposure to these reactants. Mass spectrometric identification showed that the enhancements resulted from the heterogeneous formation of complex molecules of the type KCl sub 1,2,3 CrO3 and KOH sub l,2 CrO3. Lanthanum chromite that had undergone prolonged oxidative vaporization exhibited no enhanced oxidation upon exposure to the reactants.

Kohl, F. J.↗

Exobiology science objectives at a lunar base

Five general categories of experimentation on the moon are reviewed which would provide important scientific information about chemical evolution and the origin and early evolution of life. Attention is given to: (1) chemical analyses of samples for products of prebiotic evolution, (2) analysis of crater records and understanding the implications for the origin and evolution of life on earth, (3) exposure of microbes and organics to the space environment, (4) collection of cosmic dust particles and analysis of volatiles and organics, and (5) observations of planetary environments and the interstellar medium to determine the nature and extent of chemical evolution.

Devincenzi, Donald L.↗

Field demonstration of DNAPL dehalogenation using emulsified zero-valent iron

This paper describes the results of the first field-scale demonstration conducted to evaluate the performance of nanoscale emulsified zero-valent iron (EZVI) injected into the saturated zone to enhance in situ dehalogenation of dense, nonaqueous phase liquids (DNAPLs) containing trichloroethene (TCE). EZVI is an innovative and emerging remediation technology. EZVI is a surfactant-stabilized, biodegradable emulsion that forms emulsion droplets consisting of an oil-liquid membrane surrounding zero-valent iron (ZVI) particles in water. EZVI was injected over a five day period into eight wells in a demonstration test area within a larger DNAPL source area at NASA's Launch Complex 34 (LC34) using a pressure pulse injection method. Soil and groundwater samples were collected before and after treatment and analyzed for volatile organic compounds (VOCs) to evaluate the changes in VOC mass, concentration and mass flux. Significant reductions in TCE soil concentrations (>80%) were observed at four of the six soil sampling locations within 90 days of EZVI injection. Somewhat lower reductions were observed at the other two soil sampling locations where visual observations suggest that most of the EZVI migrated up above the target treatment depth. Significant reductions in TCE groundwater concentrations (57 to 100%) were observed at all depths targeted with EZVI. Groundwater samples from the treatment area also showed significant increases in the concentrations of cis-1,2-dichloroethene (cDCE), vinyl chloride (VC) and ethene. The decrease in concentrations of TCE in soil and groundwater samples following treatment with EZVI is believed to be due to abiotic degradation associated with the ZVI as well as biodegradation enhanced by the presence of the oil and surfactant in the EZVI emulsion.

Water Pollutants/isolation & purification↗

Results from the Gas Chromatograph Mass Spectrometer (GCMS) Experiment on the Cassini-Huygens Probe

The GCMS was part of the instrument complement on the Cassini-Huygens Probe to measure in situ the chemical composition of the atmosphere during the probe descent and coupled with the Aerosol Collector Pyrolyser (ACP) experiment by serving as detector for the pyrolization products to determine the composition of the aerosol particles. The GCMS employed a quadrupole mass filter with a secondary electron multiplier detection system and a gas sampling system providing continuous direct atmospheric composition measurements and batch sampling through three gas chromatographic (GC) columns, a chemical scrubber and a hydrocarbon enrichment cell. The GCMS gas inlet was heated to prevent condensation, and to evaporate volatiles from the surface after impact. The GCMS collected data from an altitude of 146 km to ground impact. The Probe and the GCMS survived impact and collected data for 1 hour and 9 minutes on the surface. Mass spectra were collected during descent and on the ground over a range of m/z from 2 to 141. The major constituents of the lower atmosphere were confirmed to be NP and CH4. The methane mole fraction was uniform in the stratosphere. It increased below the tropopause, at about 32 km altitude, monotonically toward the surface, reaching a plateau at about 8 km at a level near saturation. After surface impact a steep increase of the methane signal was observed, suggesting evaporation of surface condensed methane due to heating by the GCMS sample inlet heater. The measured mole fraction of Ar-40 is 4.3 x 10(exp-5) and of Ar-36 is 2.8 x 10(exp -7). The other primordial noble gases were below mole fraction. The isotope ratios of C-12/C-13 determined from methane measurements are 82.3 and of N-14/N-15 determined from molecular nitrogen are 183. The D/H isotope ratio determined from the H2 and HD measurements is 2.3 x l0(exp -4). Carbon dioxide, ethane, acetylene and cyanogen were detected evaporating from the surface in addition to methane.

Niemann, Hasso B.↗

Field Demonstration of DNAPL Dehalogenation Using Emulsified Zero-Valent Iron

This paper describes the results of the first field-scale demonstration conducted to evaluate the performance of nano-scale emulsified zero-valent iron (EZVI) injected into the saturated zone to enhance in situ dehalogenation of dense, non-aqueous phase liquids (DNAPLs) containing trichloroethene (TCE). EZVI is an innovative and emerging remediation technology. EZVI is a surfactant-stabilized, biodegradable emulsion that forms emulsion droplets consisting of an oil-liquid membrane surrounding zero-valent iron (ZVI) particles in water. EZVI was injected over a five day period into eight wells in a demonstration test area within a larger DNAPL source area at NASA's Launch Complex 34 (LC34) using a pressure pulse injection method. Soil and groundwater samples were collected before and after treatment and analyzed for volatile organic compounds (V005) to evaluate the changes in VOC mass, concentration and mass flux. Significant reductions in TCE soil concentrations (>80%) were observed at four of the six soil sampling locations within 90 days of EZVI injection. Somewhat lower reductions were observed at the other two soil sampling locations where visual observations suggest that most of the EZVI migrated up above the target treatment depth. Significant reductions in TCE groundwater concentrations (57 to 100%) were observed at all depths targeted with EZVI. Groundwater samples from the treatment area also showed significant increases in the concentrations of cis-1,2-dichloroethene (cDCE), vinyl chloride (VC) and ethene. The decrease in concentrations of TCE in soil and groundwater samples following treatment with EZVI is believed to be due to abiotic degradation associated with the ZVI as well as biodegradation enhanced by the presence of the oil and surfactant in the EZVI emulsion.

Quinn, Jacqueline↗

BOREAS TGB-10 Volatile Organic Carbon Data over the SSA

The BOREAS TGB-10 team collected several trace gas data sets in its efforts to determine the role of biogenic hydrocarbon emissions with respect to boreal forest carbon cycles. This data set contains measured VOC concentrations. These data were obtained at the SSA-OJP site from May to September 1994. The data are stored in tabular ASCII files.

Westberg, Hal↗