Search NASA⌕ Search

SEARCH · Search NASA

Results for “Volatility analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Comet coma sample return instrument

The sample collection technology and instrument concept for the Sample of Comet Coma Earth Return Mission (SOCCER) are described. The scientific goals of this Flyby Sample Return are to return to coma dust and volatile samples from a known comet source, which will permit accurate elemental and isotopic measurements for thousands of individual solid particles and volatiles, detailed analysis of the dust structure, morphology, and mineralogy of the intact samples, and identification of the biogenic elements or compounds in the solid and volatile samples. Having these intact samples, morphologic, petrographic, and phase structural features can be determined. Information on dust particle size, shape, and density can be ascertained by analyzing penetration holes and tracks in the capture medium. Time and spatial data of dust capture will provide understanding of the flux dynamics of the coma and the jets. Additional information will include the identification of cosmic ray tracks in the cometary grains, which can provide a particle's process history and perhaps even the age of the comet. The measurements will be made with the same equipment used for studying micrometeorites for decades past; hence, the results can be directly compared without extrapolation or modification. The data will provide a powerful and direct technique for comparing the cometary samples with all known types of meteorites and interplanetary dust. This sample collection system will provide the first sample return from a specifically identified primitive body and will allow, for the first time, a direct method of matching meteoritic materials captured on Earth with known parent bodies.

Albee, A. L.↗

Implementation of Real-Time Hardware in the Loop Simulation for WAVE Instrument Avionics

The Regolith and Environment Science and Oxygen and Lunar Volatile Extraction (RESOLVE) payload will lead the Resource Prospector rover to hydrogen-rich locations on the moon supporting NASA's in-situ resource utilization (ISRU) mission. The Water Analysis and Volatile Extraction (WAVE) system will be responsible for heating up regolith samples and analyzing their volatiles in a vaporized state. Given the space environment, testing flight hardware and software using the scientific instruments can be costly and time consuming, which can hold back progress involving the instruments. A hardware-in-the-loop (HITL) simulation will test the Avionics Data Acquisition as well as the Instrument Interface Unit, through simulating sensors and actuators involved in supporting the WAVE instruments. HITL is a platform for testing and developing WAVE's avionics and software, where the simulation plant will imitate the LAVA and OVEN instruments, thus allowing for an accessible, efficient, and replicable testing environment.

Al Qaraghuli, Ali↗

In situ analysis of organic material with a portable mass spectrometer

We have tested a portable mass spectrometer (MS) system, the Mini 10.5, for in situ applications including the analysis of volatile organic hydrocarbon (VOC) and water soluble organic components extracted from solid material using an automated sample processing system (ASPS), by doing so we intend to demonstrate the utility of in situ analysis compared to sample acquisition and return for analysis on future robotic space missions.

Beegle, L. W.↗

Volatility of sodium, potassium, and cesium perrhenates determined by thermogravimetry

Here, in this study, we investigated the volatility of sodium, potassium, and cesium perrhenates using thermogravimetry (TG) performed on single salts and their binary mixed salts. We performed simultaneous TG and differential scanning calorimetry under a ramp heating condition at 10°C/min up to 1200°C to characterize volatilization behavior as a function of temperature. We also performed isothermal TG over a temperature range of 700 to 975°C to estimate the vapor pressures of the alkali perrhenates based on a modified Langmuir equation that relates the rate of free evaporation from the open surface to vapor pressure. In this paper, we discuss the results of our study on the temperature of evaporation and temperature-dependent vapor pressure of sodium, potassium, and cesium perrhenates in relation to rhenium volatilization behavior observed during melting of simulated waste glass.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical Modelling of Sublimation Losses During Sample Handling Within the Light WAVE Lunar Water Prospecting Instrument

NASA’s focus of exploring the Moon’s south pole under the Artemis program has placed new emphasis on characterizing the quantity and distribution of water ice and other volatiles present within the Moon’s permanently shadowed regions (PSRs), first measured during the 2009 LCROSS mission. NASA’s VIPER rover is the first of a series of prospecting missions to characterize this water ice resource. NASA’s Johnson Space Center (JSC) has developed the Light Water Analysis and Volatiles Extraction (Light WAVE) instrument shown in Figure 1 for a follow-on prospecting mission, designed to be a rover payload for water ice prospecting at various depths and locations within PSRs. A key source of error for lunar water prospecting instruments, including Light WAVE, is the loss of water in an icy regolith sample to the lunar vacuum via sublimation due to heating above its ice-stable temperature. This abstract and conference presentation discuss a sublimation model for Light WAVE’s sample crucible using COMSOL Multiphysics to assess the sublimation losses that would occur between sample collection from an external drill and sealing the sample within Light WAVE’s boiler.

Lunar Polar Water↗

Demonstration of a Lunar Water Extraction and Quantification Technique in a Relevant Environment

The presence of water ice in permanently shadowed regions on the lunar surface may enable a sustained human presence on the Moon with minimal need for consumables. The first step toward utilizing lunar water ice to advance human space exploration will be to determine the abundance, accessibility, and distribution of this valuable resource. This paper will describe the most recent test results from the Light Water Analysis and Volatile Extraction (Light WAVE) system that was designed to capture icy regolith samples acquired from a drill. Regolith samples are then weighed, sealed, and heated to release volatiles. Volatiles are captured in a volume with a known temperature and the ideal gas law is used to determine the total quantity of volatiles in the volume. The composition of the volatile mixture is determined using a mass spectrometer so that each volatile can be quantified. By quantifying the amount of water extracted from the regolith sample, and acquiring the mass of the sample, water concentration by mass can be determined. The goal of recent testing was to determine the accuracy of water quantification using a combination of ideal gas law and mass spectrometer analysis. The Light WAVE system maybe applied to future water ice investigation missions without an inherent limit to the number of samples that can be processed, and the system may also enable lunar water sample return.

Aaron J Paz↗

RESOLVE's Field Demonstration on Mauna Kea, Hawaii 2010

In cooperation with the Canadian Space Agency, and the Northern Centre for Advanced Technology, Inc., NASA has undertaken the In-Situ Resource Utilization (ISRU) project called RESOLVE (Regolith and Environment Science & Oxygen and Lunar Volatile Extraction). This project is an Earth-based lunar precursor demonstration of a system that could be sent to explore permanently shadowed polar lunar craters, where it would drill into regolith, quantify the volatiles that are present, and extract oxygen by hydrogen reduction of iron oxides. The resulting water could be electrolyzed into oxygen to support exploration and hydrogen, which would be recycled through the process. The RESOLVE chemical processing system was mounted on a Canadian Space Agency mobility chasis and successfully demonstrated on Hawaii's Mauna Kea volcano in February 2010. The RESOLVE unit is the initial prototype of a robotic prospecting mission to the Moon. RESOLVE is designed to go to the poles of the Moon to "ground truth" the form and concentration of the hydrogen/water/hydroxyl that has been seen from orbit (M3, Lunar Prospector and LRO) and to test technologies to extract oxygen from the lunar regolith. RESOLVE has the ability to capture a one-meter core sample of lunar regolith and heat it to determine the volatiles that may be released and then demonstrate the production of oxygen from minerals found in the regolith. The RESOLVE project, which is led by KSC, is a multi-center and multi-organizational effort that includes representatives from KSC, JSC, GRC, the Canadian Space Agency, and the Northern Center for Advanced Technology (NORCAT). This paper details the results obtained from four days of lunar analog testing that included gas chromatograph analysis for volatile components, remote control of chemistry and drilling operations via satalite communications, and real-time water quantification using a novel capacitance measurement technique.

Captain, Janine↗

Secondary Volcanically-Induced Lunar Atmosphere and Lunar Volatiles: 3-D Modeling and Analysis

The fact that the Moon could have a transient secondary atmosphere due to volcanic outgassing has been known for some time, though typically such an atmosphere was believed to be extremely thin (~10-8 bar) [1]. But recent research by Needham and Kring (NK) [2] suggests that during the peak of volcanic activity ~3.5 Ga such a volcanically-outgassed atmosphere could reach ~10-2 bar of surface pressure. In similar research Wilson et al. [3] proposed a more conservative estimate, arguing that the thickness of such an atmosphere would depend on the intervals between major eruptions and may not exceed microbar densities. In either case a collisional atmosphere could be present, which would control transport of outgassed volatiles (such as H2O) and their deposition in polar regions, where they could be preserved until modern day frozen in permanently shadowed regions (PSR) or buried beneath the regolith. Here we study such a hypothetical atmosphere to investigate its stability, meteorological properties and the effect on transport of volatiles. We use the ROCKE-3D planetary 3-D General Circulation Model (GCM)[4]. The insolation and orbital parameters were set to conditions 3.5 Ga. The atmospheric composition, based on the list of outgassed species presented by NK in combination with our estimates for atmospheric escape, condensation and the results from our 1-D chemistry model, was chosen to be either CO-dominated or CO2-dominated (depending on atmospheric temperature). In this study we restricted ourselves to relatively "thick" lunar atmospheres of 1-10 mb, though we believe that our results will scale to thinner atmospheres as well. We present the results for ground and atmospheric temperature for modeled atmospheres over a wide parameter space. In particular we consider different atmospheric compositions (CO or CO2 dominated), a set of atmospheric pressures from 1 mb to 10 mb and a set of obliquities from 0o to 40o. We also present an experiment of a single major eruption [5] and show that in just 3 years ~80% of the outgassed water is deposited in polar regions. This demonstrates the efficiency of such an atmosphere in delivering volatiles. We argue that a secondary lunar atmosphere could play a significant role in forming volatile deposits currently observed in the polar regions of the Moon.

Lunar atmospheres↗

Sustainable Recycling of Rare-Earth Elements from NdFeB Magnet Swarf: Techno-Economic and Environmental Perspectives

Rare-earth elements (REEs) are increasingly susceptible to supply risks due to their limited geographical availability and growing demand in clean energy applications such as neodymium-iron-boron (NdFeB) magnets used in electric vehicles and wind turbines. When NdFeB magnets are produced, 6–73% of swarf is generated during the manufacturing steps. This paper presents an innovative technology that utilizes copper nitrate to dissolve REEs in NdFeB magnet swarf and subsequently recovers ~97% of them as mixed rare-earth oxides (REOs) of purity higher than 99.5%. Techno-economic analysis (TEA) and life cycle assessment (LCA) quantified the economic and environmental impacts of adopting the proposed acid-free dissolution technology, projecting a net profit margin of 12–43% and a global warming impact reduction by up to 73% compared to the prevailing REO production routes in China. As copper nitrate is the single largest contributor to the cost and environmental footprint, recycling of copper nitrate was investigated as well as using alternative copper salts (e.g., copper acetate), revealing significant improvements in TEA and LCA results. Dysprosium was a major revenue source, highlighting the importance of targeting electric vehicle magnets that are rich in dysprosium. As the REO market is volatile, sensitivity analysis was employed to evaluate the profitability of the proposed technology under different REO prices over the last 11 years. Overall, our results confirmed the economic and environmental viability of the proposed technology for sustainable recycling of REEs from the NdFeB magnet swarf.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measuring Sulfur Isotope Ratios from Solid Samples with the Sample Analysis at Mars Instrument and the Effects of Dead Time Corrections

The Sample Analysis at Mars (SAM) instrument suite comprises the largest science payload on the Mars Science Laboratory (MSL) "Curiosity" rover. SAM will perform chemical and isotopic analysis of volatile compounds from atmospheric and solid samples to address questions pertaining to habitability and geochemical processes on Mars. Sulfur is a key element of interest in this regard, as sulfur compounds have been detected on the Martian surface by both in situ and remote sensing techniques. Their chemical and isotopic composition can belp constrain environmental conditions and mechanisms at the time of formation. A previous study examined the capability of the SAM quadrupole mass spectrometer (QMS) to determine sulfur isotope ratios of SO2 gas from a statistical perspective. Here we discuss the development of a method for determining sulfur isotope ratios with the QMS by sampling SO2 generated from heating of solid sulfate samples in SAM's pyrolysis oven. This analysis, which was performed with the SAM breadboard system, also required development of a novel treatment of the QMS dead time to accommodate the characteristics of an aging detector.

Franz, H. B.↗

In situ , in vivo , and in operando imaging and spectroscopy of liquids using microfluidics in vacuum

This review offers a succinct overview of the development of a vacuum-compatible microfluidic reactor system for analysis at the liquid vacuum interface (SALVI), and its diverse applications in in situ, in vivo, and in operando imaging of liquid surfaces as well as the air-liquid (a-l), liquid-liquid (l-l), and solid-liquid (s-l) interfaces in the past decade. SALVI is one of the first microfluidics-based reactors that has enabled direct analysis of volatile liquids in vacuum surface tools such as scanning electron microscopy (SEM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). Its integration into ambient and vacuum spectroscopy and microscopy is illustrated. Several applications are highlighted including (1) imaging nanoparticles in liquid using in situ SEM; (2) mapping the evolving l-l interface using in situ x-ray absorption spectroscopy and ToF-SIMS; (3) following complex a-l interfacial oxidation reaction products using in situ ToF-SIMS; (4) capturing biological interfaces of cells and microbes via in vivo multimodal and correlative imaging; and (5) monitoring the dynamic solid electrode and liquid electrolyte interface using in operando molecular imaging. Finally, outlook and recommendations are presented. Besides showing the holistic information volume obtained by real-time multiplexed imaging, this review intends to convey the importance of tool development in revolutionizing surface and interface analysis using vacuum platforms previously limited to solid surfaces. Microfluidics is manifested to be not limited to ambient conditions in many examples in this review. Moreover, fundamental interfacial phenomena underpinning mass and charge transfer can now be pursued in real time via innovated chemical imaging and spectroscopy.

42 ENGINEERING↗

Reversible Colorimetric Sensing of Volatile Analytes By Wicking in Close Proximity to A Photonic Film

Isolation of volatile analytes from environmental or biological fluids is a rate-determining step that can delay the response time for continuous sensing. In this paper, we demonstrate a colorimetric sensing system that enables the rapid detection of gas-phase analytes released from a flowing micro-volume fluid sample. The sensor platform is an analyte-responsive metal-insulator-metal (MIM) thin-film structure integrated with a large area quartz micropillar array. This allows precise planar alignment and microscale separation (310 μm) of the optical and fluidic structures. This configuration offers rapid and homogeneous color changes over large areas that permits detection by low-resolution optics or eye, which is well-suited to portable/wearable devices. For our proof-of-principle demonstration, we utilized a poly(methyl methacrylate) (PMMA) spacer and evaluated the sensor's response (color change) to ethanol vapor. We show that the RGB color value is quantitatively linked to the spacer swelling, which is reversible and repeatable. The optofluidic platform reduces the sensor response time from minutes to seconds compared with experiments using a conventional chamber. The sensor's concentration-dependent response was examined, confirming the potential of the reported sensing platform for continuous, compact, and quantitative colorimetric analysis of volatile analytes in low-volume samples, such as biofluids.

Timothy J. Palinski↗

Development of a Gas Chromatography with High-Resolution Time-of-Flight Mass Spectrometry Methodology for BDNPA/F

Analysis of thermally labile compounds such as bis(2,2-dinitropropyl) acetal/formal (BDNPA/F), an energetic plasticizer, is usually performed via liquid chromatography (LC) as opposed to gas chromatography (GC) due to thermal decomposition in the inlet or the analytical column. While LC is a powerful technique, the analysis of volatile and semivolatile compounds is best suited to GC. Herein, a method was developed for a gas chromatograph coupled to high-resolution mass spectrometer (GC-HRMS), utilizing a programmable temperature vaporizer (PTV) inlet. A subset of the native compounds and several produced by the thermal decomposition of BDNPA/F in the inlet were evaluated by using multiple PTV inlet parameters to determine the optimal ramp rate and final temperature of the inlet (60 °C/min from 60 to 325 °C). The optimized GC-HRMS method nearly reduced all thermal decomposition, allowing for an excellent separation to be obtained. Furthermore, multiple ionization methods, including electron impact (EI), negative chemical ionization (NCI), and positive chemical ionization (PCI), were used to explore the many chemical differences between the BDNPA/F samples. A preliminary investigation of the benefits of using GC-HRMS to evaluate the chemical differences between unaged and aged BDNPA/F samples for unique insight was evaluated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solvent Hold Tank Sample Results for MCU-19-366- 367-368 (April 2019), MCU-19-469-470-471 (May 2019), MCU-19-524-525-526 (June 2019): Quarterly Report

A trend summary of three sets of Solvent Hold Tank (SHT) monthly samples MCU-19-366-367-368 (April), MCU-19-469-470-471 (May), and MCU-19-524-525-526 (June) are reported. Most of the conclusions are based on the June SHT sample (MCU-19-524-525-526). Analyses of the June SHT sample (MCU-19-524- 525-526) indicated that the Modifier (Cs-7SB) and the Extractant (MaxCalix) concentrations were below their nominal recommended concentrations (169,000 mg/L and 46,900 mg/L respectively) by 4% and 2% respectively but consistent with previously observed levels during normal runs. The Suppressor (N,N’,N”– tris(3,7-dimethyloctyl)guanidine or TiDG) concentration has decreased since the March 2019 measurement to 793 mg/L, which is above the minimum recommended concentration (479 mg/L). The Semi-Volatile Organic Analysis (SVOA) did not detect any impurities. However, the Fourier Transform Hydrogen Nuclear Magnetic Resonance (FT-HNMR) analysis detected presence of phthalates at a few ppm. The impurity concentration was highest in the April sample and consistently detected in the May and June samples (but always registered as a few ppm or less). Another impurity observed in the samples was mercury. Based on the June SHT sample, up to 25 ± 5 micrograms of mercury per mL of solvent was detected (as the average of the Direct Mercury Analysis (DMA) and X-Ray Fluorescence (XRF) methods). The higher mercury concentration in the solvent (as determined in the last three-monthly samples) is possibly due to the higher mercury concentration in Salt Batches 9 and 10. The gamma concentration (~2.90E4 dpm/mL) measured in the June 2019 SHT samples was consistent with previous values observed when the Modular Caustic-Side Solvent Extraction Unit (MCU) was operating continuously (for example, between December 2016 and January 2017). Statistical analysis of the different analytical methods detected a bias between the FT-HNMR and the High Performance Liquid Chromatography (HPLC) methods when measuring the MaxCalix and Modifier concentrations; the FT-HNMR gave a higher concentration possibly due to peak overlapping in the measured data. A bias was detected when measuring total mercury by the DMA method versus the XRF method with the XRF method reported higher mercury concentrations. The laboratory will continue to monitor the quality of the solvent for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent Hold Tank Sample Results for MCU-19-569-571 (December 2019), MCU-20-1-28 (January 2020), and MCU-20-29-30-31 (June 2020) (Quarterly Report)

A trend summary of three Solvent Hold Tank (SHT) monthly samples MCU-19-569-570-571 (December 2019), MCU-20-1-28 (January 2020), and MCU-20-29-30-31 (June 2020) are reported. Most of the conclusions are based on the June 2020 SHT sample (MCU-20-29-30-31). Analyses of the June 2020 SHT sample indicated that the Modifier (Cs-7SB) and the Extractant (MaxCalix) concentrations were above their nominal recommended concentrations (169,000 mg/L and 46,900 mg/L respectively) by 6% and 7% respectively. The Suppressor (N,N’,N”–tris(3,7-dimethyloctyl)guanidine or TiDG) concentration has remained at 833 ± 16 mg/L, but it is above the minimum recommended concentration (479 mg/L). The Semi-Volatile Organic Analysis (SVOA) and FT-HNMR did not detect any organic impurities. Another impurity observed in the samples was mercury. Based on the June 2020 SHT sample, up to 23 ± 5 micrograms of mercury per gram of solvent (or 19 ± 4 mg/L) was detected. The mercury concentration steadily decreased from 34.8 ug/g solvent (or 21.9 mg/L) in the December 2019 SHT sample to 34.8 ug/g solvent (or 19 mg/L) in the June 2020 SHT sample. The gamma concentration (~3.33E4 dpm/mL) measured in the June 2020 SHT samples was consistent with previous values observed when MCU was idle (for example, between February 2017 and August 2017). If additional SHT samples become available, the laboratory will continue to monitor the quality of the solvent for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Detection of soil microorganism in situ by combined gas chromatography mass spectrometry

Experimental tests were made to determine whether analysis of volatile metabolic products, formed in situ, is a viable procedure for an extraterrestrial life detection system. Laboratory experiments, carried out under anaerobic conditions with addition of carbon source, extended to include a variety of soils and additional substrates. In situ experiments were conducted without amendment using a vacuum sampling system.

Alexander, M.↗

Space radiation effects on composite matrix materials - Analytical approaches

In-vacuo ultraviolet and gamma radiation exposure tests are utilized in a study aimed at the identification of radiation damage mechanisms in composite materials, with the objective of predicting the long-term behavior of composite structures in a space environment at geosynchronous orbit. Physical and chemical methods of polymer characterization are utilized for the study of composite matrix degradation, in conjunction with GC/MS techniques for the analysis of volatile by-products.

Giori, C.↗