Search NASA⌕ Search

SEARCH · Search NASA

Results for “Voltage positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Module-Level Solutions For Degradation by Ionization Damage

After years of improving module efficiency while targeting mean degradation rates of 0.5 to 0.6 %/y for crystalline silicon technology, there is much evidence that the degradation rates are now increasing significantly. Contributing factors include:Radiation damage (UV-Light Induced Degradation): Trina solar: -4.5%/y degradation rate in Singapore, DOE National Laboratory Regional Test Centers showed degradation of -1% < r < -2%/y in crystalline silicon modules, Jinko Solar: -4% < r < -7% efficiency loss from 540 MJ/m-2 of UV-A light, ISFH: 15% relative power loss during of 1.8 GJ/m-2 UV exposure, attributed to H+. Electrical bias from positive system voltage (e.g., +1000 V, +1500 V) can drive ions and metallization through the encapsulation, NREL: Ion transport can affect the cell passivation, resulting in power loss of 5% to 40% in p-PERC+ (bifacial), NREL: Damage at cell rear with up to 17% power at cell fronts in n-PERT modules. Delamination can also occur due to cell surface reactions driven by light and bias.

module efficiency↗

Series-Connected Buck Boost Regulators

A series-connected buck boost regulator (SCBBR) is an electronic circuit that bucks a power-supply voltage to a lower regulated value or boosts it to a higher regulated value. The concept of the SCBBR is a generalization of the concept of the SCBR, which was reported in "Series-Connected Boost Regulators" (LEW-15918), NASA Tech Briefs, Vol. 23, No. 7 (July 1997), page 42. Relative to prior DC-voltage-regulator concepts, the SCBBR concept can yield significant reductions in weight and increases in power-conversion efficiency in many applications in which input/output voltage ratios are relatively small and isolation is not required, as solar-array regulation or battery charging with DC-bus regulation. Usually, a DC voltage regulator is designed to include a DC-to-DC converter to reduce its power loss, size, and weight. Advances in components, increases in operating frequencies, and improved circuit topologies have led to continual increases in efficiency and/or decreases in the sizes and weights of DC voltage regulators. The primary source of inefficiency in the DC-to-DC converter portion of a voltage regulator is the conduction loss and, especially at high frequencies, the switching loss. Although improved components and topology can reduce the switching loss, the reduction is limited by the fact that the converter generally switches all the power being regulated. Like the SCBR concept, the SCBBR concept involves a circuit configuration in which only a fraction of the power is switched, so that the switching loss is reduced by an amount that is largely independent of the specific components and circuit topology used. In an SCBBR, the amount of power switched by the DC-to-DC converter is only the amount needed to make up the difference between the input and output bus voltage. The remaining majority of the power passes through the converter without being switched. The weight and power loss of a DC-to-DC converter are determined primarily by the amount of power processed. In the SCBBR, the unswitched majority of the power is passed through with very little power loss, and little if any increase in the sizes of the converter components is needed to enable the components to handle the unswitched power. As a result, the power-conversion efficiency of the regulator can be very high, as shown in the example of Figure 1. A basic SCBBR includes a DC-to-DC converter (see Figure 2). The switches and primary winding of a transformer in the converter is connected across the input bus, while the secondary winding and switches are connected in series with the output bus, so that the output voltage is the sum of the input voltage and the secondary voltage of the converter. In the breadboard SCBBR, the input voltage applied to the primary winding is switched by use of metal oxide/semiconductor field-effect transistors (MOSFETs) in a full bridge circuit; the secondary winding is center-tapped, with two MOSFET switches and diode rectifiers connected in opposed series in each leg. The sets of opposed switches and rectifiers are what enable operation in either a boost or a buck mode. In the boost mode, input voltage and current, and the output voltage and current are all positive; that is, the secondary voltage is added to the input voltage and the net output voltage can be regulated at a value equal or greater than the input voltage. In the buck mode, input voltage is still positive and the current still flows in the same direction in the secondary, but the switches are controlled such that some power flows from the secondary to the primary. The voltage across the secondary and the current into the primary are reversed. The result is that the output voltage is lower than the input voltage, and some power is recirculated from the converter secondary back to the input. Quantitatively, the advantage of an SCBBR is a direct function of the regulation range required. If, for example, a regulation range of 20 percent is required for a 500-W supply, th it suffices to design the DC-to-DC converter in the SCBBR for a power rating of only 100 W. The switching loss and size are much smaller than those of a conventional regulator that must be rated for switching of all 500 W. The reduction in size and the increase in efficiency are not directly proportional to switched-power ratio of 5:1 because the additional switches contribute some conduction loss and the input and output filters must be larger than those typically required for a 100-W converter. Nevertheless, the power loss and the size can be much smaller than those of a 500-W converter.

Birchenough, Arthur G.↗

Apparatus Tests Thermocouples For Seebeck Inhomogeneity

Automated apparatus reveals sources of error not revealed in calibration. Computer-controlled apparatus detects and measures Seebeck inhomogeneities in sheathed thermocouples. Measures thermocouple output voltage as function of position of probe along sharp gradient of temperature. Abnormal variations in voltage-versus-position data indicative of Seebeck inhomogeneities. Prototype for development of standard method and equipment for routine acceptance/rejection testing of sheathed thermocouples in industrial and research laboratories.

Burkett, Cecil G., Jr.↗

Direct-Current Unbalance Detector

Short circuits to ground indicated by voltage changes. Current transducer connected in bridge circuit with floating 30-Vdc power supply measures voltage unbalance between positive and negative powerlines and ground. Detection circuit output swings higher or lower than normal balanced condition voltage to signify unbalance toward positive or negative side respectively. Circuit configuration adaptable to monitor 4- to 20-mA current loops often found in industrial controls.

Wagner, A. P.↗

Investigation of the Effects of Cathode Flow Fraction and Position on the Performance and Operation of the High Voltage Hall Accelerator

The National Aeronautics and Space Administration (NASA) Science Mission Directorate In- Space Propulsion Technology office is sponsoring NASA Glenn Research Center (GRC) to develop a 4 kW-class Hall thruster propulsion system for implementation in NASA science missions. Tests were performed within NASA GRC Vacuum Facility 5 at background pressure levels that were six times lower than what has previously been attained in other vacuum facilities. A study was conducted to assess the impact of varying the cathode-to-anode flow fraction and cathode position on the performance and operational characteristics of the High Voltage Hall Accelerator (HiVHAc) thruster. In addition, the impact of injecting additional xenon propellant in the vicinity of the cathode was also assessed. Cathode-to-anode flow fraction sensitivity tests were performed for power levels between 1.0 and 3.9 kW. It was found that varying the cathode flow fraction from 5 to approximately 10% of the anode flow resulted in the cathode-to-ground voltage becoming more positive. For an operating condition of 3.8 kW and 500 V, varying the cathode position from a distance of closest approach to 600 mm away did not result in any substantial variation in thrust but resulted in the cathode-to-ground changing from -17 to -4 V. The change in the cathode-to-ground voltage along with visual observations indicated a change in how the cathode plume was coupling to the thruster discharge. Finally, the injection of secondary xenon flow in the vicinity of the cathode had an impact similar to increasing the cathode-to-anode flow fraction, where the cathode-to-ground voltage became more positive and discharge current and thrust increased slightly. Future tests of the HiVHAc thruster are planned with a centrally mounted cathode in order to further assess the impact of cathode position on thruster performance.

Cathode Coupling↗

Effect of KOH concentration and anions on the performance of Ni-H2 battery positive plate

The capacity and voltage behavior of electrochemically impregnated sintered nickel positive plates was examined by galavanostatic charging; and discharging in a flooded electrolyte cell. Three different concentrations of KOH (40 percent, 31 percent, and 26 percent) and 31 percent KOH containing dissolved nitrate, sulfate or silicate were investigated. The end of charge voltage at C/10 charge and at 10 C showed the following order: 40 percent KOH is greater than 31 percent KOH alone and in the presence of the anions greater than 26 percent KOE. The middischarge voltage at C/2 discharge was higher in 26 percent KOH, almost the same for 31 percent KOH with and without the added contaminants and much lower for 40 percent KOH. The plate capacity was marginally affected by cycling in all cases except for 40 percent KOH where the capacity declined after 1000 cycles at 80 percent DOD. At the end of cycling the plate tested in the presence of sulfate and silicate experienced measurable weight loss as a result of active material extrusion. Cyclic voltammetry of miniature electrodes in 31 percent KOH showed that the second oxidation peak that corresponds to the formation of a different phase of oxidized Ni has a lower peak current at -5 C compared to 25 C and oxygen evolution occurs a higher potential at -5 C. The reduction peak (discharge reaction) is more polarized at 25 C compared to -5 C. The presence of silicate alters the potentials only marginally. The implications of these results in plate treatment and low temperature operation are discussed.

Vaidyanathan, H.↗

Effect of KOH Concentration and Anions on the Performance of a Ni-H2 Battery Positive Plate

The capacity and voltage behavior of electrochemically impregnated sintered nickel positive plates was examined by galvanostatic charging and discharging in a flooded electrolyte cell. Three different concentrations of potassium hydroxide (KOH) (40, 31, and 26 percent) and 31 percent KOH containing dissolved nitrate, sulfate, or silicate were investigated. The end-of-charge voltage at C/10 charge and at 10 degrees C showed the following order: 40 percent KOH greater than 31 percent KOH alone and in the presence of the anions greater than 26 percent KOH. The mid discharge voltage at C/2 discharge was higher in 26 percent KOH, almost the same for 31 percent KOH with and without added contaminants, and much lower for 40 percent KOH. The plate capacity was marginally affected by cycling in all cases except for 40 percent KOH, where the capacity declined after 1,000 cycles at 80 percent depth of discharge (DOD). At the end of cycling, all the plates tested experienced a weight loss, except in the case of 31 percent KOH, as a result of active material extrusion. Cyclic voltammetry of miniature electrodes in 31 percent KOH showed that the cathodic peak potentials are less polarized in the presence and absence of silicate at -5 degrees C compared to 25 degrees C indicating a slightly higher voltage during discharge in a Ni-H2 battery. Futhermore, the features of the current-potential profile were practically unchanged in the presence of silicate.

Vaidyanathan, Hari↗

Incrementally Variable High-Voltage Supply

Programable power supply provides regulated output ranging from 2.5 to 2,500 volts. Exponential digital-to-analog converter provides low-voltage analog signal to power converter and to negative and positive high-voltage regulators. In response, converter furnishes voltage of approximate magnitude represented by analog signal, and regulators adjust voltage to precise magnitude. Entire voltage range covered in 169 steps. Total power consumption expected to be less than 2 watts.

Potter, D. W.↗

Dilute plasma coupling currents to a high voltage solar array in weak magnetic fields

The plasma coupling current to an approximately 2000 sq cm array was measured for externally biased positive and negative voltages on the array to 1000 V in applied magnetic field strengths from 0 to 0.93 G. The plasma density varied from 2,000 to 1.3 million electrons/cu cm. It was found that the magnetic field primarily increased the plasma coupling current for negative biases. For positive bias, the current could increase or decrease depending on the voltage, field strength, and plasma density. It was also found that the plasma coupling current was not very sensitive to how the plane of the array was oriented relative to the magnetic field.

Grier, N. T.↗

Mode-Switching Algorithms For Antenna Servocontroller

New algorithms proposed to reduce acceleration and velocity perturbations caused by transitions between control modes of servocontrol system. Consists of position-control loop closed around rate (velocity)-control loop. Rate loop analog type-1 controller. Rate command (voltage) from position-loop controller compared to filtered tachometer feedback rate (voltage) to create rate error. Rate loop adjusts actuator-command signal to null rate error, causing antenna to turn at commanded rates.

Nickerson, Jack A.↗

A rocket-borne electrostatic analyzer for measurement of energetic particle flux

A rocket-borne electrostatic analyzer experiment is described. It is used to measure energetic particle flux (0.9 to 14 keV) in the nighttime midlatitude E region. Energetic particle precipitation is believed to be a significant nighttime ionization source, particularly during times of high geomagnetic activity. The experiment was designed for use in the payload of a Nike Apache sounding rocket. The electrostatic analyzer employs two cylindrical parallel plates subtending a central angle of 90 deg. The voltage waveform supplied to the plates is a series of steps synchronized to the spin of the payload during flight. Both positive and negative voltages are provided, extending the detection capabilities of the instrument to both electrons and protons (and positive ions). The development, construction and operation of the instrument is described together with a preliminary evaluation of its performance in a rocket flight.

Pozzi, M. A.↗

System and method for voltage-based real-time micro-object position control with the aid of a digital computer

The system and method described allow for real-time control over positioning of a micro-object. A movement of at least one micro-object suspended in a medium can be induced by a generation of one or more forces by electrodes proximate to the micro-object. Prior to inducing the movement, a simulation is used to develop a model describing a parameter of an interaction between each of the electrodes and the micro-object. A function describing the forces generated by an electrode and an extent of the movement induced due to the forces is generated using the model. The function is used to design closed loop policy control scheme for moving the micro-object towards a desired position. The position of the micro-object is tracked and taken into account when generating voltage patterns in the scheme.

Matei, Ion↗

Static inverter with synchronous output waveform synthesized by time-optimal-response feedback

Time-optimal-response 'bang-bang' or 'bang-hang' technique, using four feedback control loops, synthesizes static-inverter sinusoidal output waveform by self-oscillatory but yet synchronous pulse-frequency-modulation (SPFM). A single modular power stage per phase of ac output entails the minimum of circuit complexity while providing by feedback synthesis individual phase voltage regulation, phase position control and inherent compensation simultaneously for line and load disturbances. Clipped sinewave performance is described under off-limit load or input voltage conditions. Also, approaches to high power levels, 3-phase arraying and parallel modular connection are given.

Kernick, A.↗

Inductive Non-Contact Position Sensor

Optical hardware has been developed to measure the depth of defects in the Space Shuttle Orbiter's windows. In this hardware, a mirror is translated such that its position corresponds to the defect's depth, so the depth measurement problem is transferred to a mirror-position measurement problem. This is preferable because the mirror is internal to the optical system and thus accessible. Based on requirements supplied by the window inspectors, the depth of the defects needs to be measured over a range of 200 microns with a resolution of about 100 nm and an accuracy of about 400 nm. These same requirements then apply to measuring the position of the mirror, and in addition, since this is a scanning system, a response time of about 10 ms is needed. A market search was conducted and no sensor that met these requirements that also fit into the available housing volume (less than one cubic inch) was found, so a novel sensor configuration was constructed to meet the requirements. This new sensor generates a nearly linearly varying magnetic field over a small region of space, which can easily be sampled, resulting in a voltage proportional to position. Experiments were done with a range of inductor values, drive voltages, drive frequencies, and inductor shapes. A rough mathematical model was developed for the device that, in most aspects, describes how it operates and what electrical parameters should be chosen for best performance. The final configuration met all the requirements, yielding a small rugged sensor that was easy to use and had nanometer resolution over more than the 200-micron range required. The inductive position sensor is a compact device (potentially as small as 2 cubic centimeters), which offers nanometer-position resolution over a demonstrated range of nearly 1 mm. One of its advantages is the simplicity of its electrical design. Also, the sensor resolution is nearly uniform across its operational range, which is in contrast to eddy current and capacitive sensors whose sensitivity is dependent upon position.

Youngquist, Robert↗

Design of high-voltage, high-power, solid state remote power controllers for aerospace applications

Two general types of remote power controllers (RPC's), which combine the functions of a circuit breaker and a switch, were developed for use in dc aerospace systems. Power-switching devices used in the designs are the gate-turnoff thyristor (GTO) and MOSFET. The RPC's can switch dc voltages to 1200 V and currents to 1000 A. Seven different units were constructed and subjected to laboratory and thermal vacuum testing. Two of these were dual units that switch both positive and negative voltages simultaneously. The RPC's using MOSFET's have slow turnon and turnoff times which limit surge currents and voltage spiking from high di/dt. The GTO's have much faster transition times. All RPC's have programmable overload tripout proportional to I sq T and microsecond tripout for large overloads.

Sturman, J. C.↗

High-voltage, high-power, solid-state remote power controllers for aerospace applications

Two general types of remote power controller (RPC) that combine the functions of a circuit breaker and a switch were developed for use in direct-current (dc) aerospace systems. Power-switching devices used in these designs are the relatively new gate-turnoff thyristor (GTO) and poweer metal-oxide-semiconductor field-effect transistors (MOSFET). The various RPC's can switch dc voltages to 1200 V and currents to 100 A. Seven different units were constructed and subjected to comprehensive laboratory and thermal vacuum testing. Two of these were dual units that switch both positive and negative voltages simultaneously. The RPC's using MOSFET's have slow turnon and turnoff times to limit voltage spiking from high di/dt. The GTO's have much faster transition times. All RPC's have programmable overload tripout and microsecond tripout for large overloads. The basic circuits developed can be used to build switchgear limited only by the ratings of the switching device used.

Sturman, J. C.↗

Voltage control of magnetism in Fe3-xGeTe2/In2Se3 van der Waals ferromagnetic/ferroelectric heterostructures

Abstract We investigate the voltage control of magnetism in a van der Waals (vdW) heterostructure device consisting of two distinct vdW materials, the ferromagnetic Fe 3- x GeTe 2 and the ferroelectric In 2 Se 3 . It is observed that gate voltages applied to the Fe 3- x GeTe 2 /In 2 Se 3 heterostructure device modulate the magnetic properties of Fe 3- x GeTe 2 with significant decrease in coercive field for both positive and negative voltages. Raman spectroscopy on the heterostructure device shows voltage-dependent increase in the in-plane In 2 Se 3 and Fe 3- x GeTe 2 lattice constants for both voltage polarities. Thus, the voltage-dependent decrease in the Fe 3- x GeTe 2 coercive field, regardless of the gate voltage polarity, can be attributed to the presence of in-plane tensile strain. This is supported by density functional theory calculations showing tensile-strain-induced reduction of the magnetocrystalline anisotropy, which in turn decreases the coercive field. Our results demonstrate an effective method to realize low-power voltage-controlled vdW spintronic devices utilizing the magnetoelectric effect in vdW ferromagnetic/ferroelectric heterostructures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Predictive Coordinated and Cooperative Voltage Control for Systems With High Penetration of PV

In this paper, we propose a predictive coordinated and cooperative voltage control method in a power distribution system with high penetration of photovoltaic (PV) units. First, an integrated coordinated voltage control of voltage regulators (VRs) tap positions and cooperative distributed control of the reactive power output from PV inverters are used to maintain system voltages within an appropriate bandwidth. Next, solar power forecasting is applied to predict voltage changes, which are used to set the VR tap positions and capacitor switch status to prevent large voltage fluctuations. The fine tuning of voltage adjustment is then achieved by cooperative control of PV inverters to maintain a uniform voltage profile across the system. The proposed method is tested on a modified IEEE 123-node test feeder with high penetration of PVs using real measurement data and compared with the base case. Simulation results demonstrate the effectiveness of the integrated voltage control, as well as the enhancement from the predictive control through solar power forecasting-enabled voltage change estimates. Comparison to previous work in the literature shows significant improvement in terms of voltage deviation and reduction in excessive tap changes.

14 SOLAR ENERGY↗