Search NASA⌕ Search

SEARCH · Search NASA

Results for “Voltage positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The Regenerative Current Mirror: A Very Low Power Front-End Amplifier for Silicon Pixel Detectors

In pixelized detectors, reducing power consumption in the front end ASIC chips becomes a crucial demand. Optimization based on mature pre-amplifier schemes today is unlikely to bring sufficient improvements. A new CMOS front-end gain stage topology with very low power consumption called regenerative current mirror is developed to fulfill the demand. The circuit takes advantage of high speed performance of current amplification while operating with relatively low bias current. The regenerative current mirror uses a NMOS current mirror and a PMOS current mirror, both with nominal gain of 1, to form a loop-back topology that provides a positive feedback. An NMOS FET with an external adjustable voltage applied to it gate terminal is used to limit open loop gain of the current mirrors to be slightly lower than 1. This yields a net gain of the positive feedback loop to be much larger than 1 while operating the current mirrors under relatively low bias currents. Simulation shows that in 65 nm fabrication process, the power consumption of the gain stages suitable for silicon pixel detectors can be controlled < 10 micro-Watts per channel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modifying Surface Chemistry to Enhance the Electrochemical Stability of Nickel‐Rich Cathode Materials

Residual impurities such as lithium carbonate and hydroxide are a major concern for accelerating parasitic reactions at the cathode electrolyte interface of lithium-ion batteries. Removal of these lithium-bearing species becomes a necessity for high-performance nickel-rich cathode materials. Instead of directly removing these impurities through washing steps, a wet impregnation process is employed to convert these detrimental surface impurities into beneficial surface coating on nickel-rich cathode materials. Specifically, the pristine cathode material is treated with Al(H 2 PO 4 ) 3 solution to convert undesired compounds into Li 3 PO 4 and AlPO 4 , both of which are considered positive surface coating materials for high-voltage cathodes. It is found that the introduced modification greatly suppresses the interfacial impedance hike and improves the capacity retention of the cathode material after repeating charging/discharging. It is believed that these benefits are realized through the modification of the surface chemistry of the cathode material, which helps to slow down the parasitic reactions and reduce the damage to the cathode material.

25 ENERGY STORAGE↗

Logical Majorana zero modes in a nanowire network

We present a scheme to use physical Majorana quasizero modes at each junction of a two-dimensional nanowire network to build a logical Majorana zero mode, the location of which is controllable through gate voltages. The wire network is a way to realize a recent proposal to imprint a Kekulé vortex pattern on a honeycomb lattice via gate voltages. We show that a specific type of junction, other than a naive Y or T junction, is needed to realize, without breaking time-reversal symmetry, an artificial “graphene” system with Majorana fermions instead of complex ones at each site. The junction we propose (i) traps exactly one physical Majorana (quasi)zero mode at each site of either a brick wall or honeycomb lattice and (ii) allows this mode to hybridize with all three neighboring sites. Using a lattice of these junctions and starting from an electronic, tight-binding model for the wires, we imprint the voltage patterns corresponding to the Kekulé vortex and observe the emergence of the logical Majorana zero mode at the vortex core. By suitable adiabatic modulations of gate voltages as a function of time, the positions of individual Kekulé vortices can be moved, and in this manner, non-Abelian braiding of the logical Majoranas bound to the vortex cores can be performed. We provide the range of parameters where these excitations could be realized experimentally.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Photovoltaics Research and Development: Device Architecture for Next-Generation CdTe PV. Cooperative Research and Development Final Report, CRADA Number CRD-17-00662

Despite remarkable efficiency improvements at the cell and module level, thin-film CdTe PV suffers from a significant voltage deficit compared with the ideal. The proposed solution is to build cells with fully depleted absorbers and with energy barriers front and back to direct electrons and holes in appropriate directions. Combined with minimal interfacial recombination, this approach, which is similar to the successful silicon HIT cells, circumvents the need for higher lifetimes and carrier concentration to achieve higher voltage, Colorado State is particularly well-positioned to the address the depleted absorbed architecture. It has robust single-vacuum closed-spaced-sublimation deposition chamber, currently being enhanced with new sources for CdTe alloys and grading. It has made reasonable-efficiency cells with absorbers as thin as 0.3 um, it has demonstrated electron reflection at the rear of the absorber with a continuous CdMgTe layer, it has replaced CdS with MgZnO, which has several advantages including tunable band offsets, and it has achieved 16.8% efficiency. It also has a mature suite of measurement equipment for cell evaluation and the experience to effectively analyze its results for refinement in cell fabrication. Several healthy collaborations will continue within the CdTe community.

14 SOLAR ENERGY↗

Digital Twin User Guide for Chelan County Public Utility District

This user manual offers a comprehensive guide for developing a Digital twin (DT) of a Kaplan turbine at Chelan County Public Utility District (Chelan PUD) using neural networks. As variable renewable generation expands, hydropower units must operate with optimal efficiency and stability. For Kaplan machines, this flexibility is achieved through coordinated control of guide vane (wicket gates) opening and runner blade pitch, which amplifies the plant’s inherent nonlinear behavior and challenges traditional physics-only modeling. The efficiency of the Kaplan turbine varies with different combinations of the guide vans (wicket gate) opening and the blade angle. Each guide van opening and blade angle has a corresponding highest efficiency point, forming a cam relationship that represents the optimal combination.The discharge of a hydraulic turbine is controlled by the opening angle of the guide vans. Therefore, for each value of head, there is a certain guide van opening and blade angle that corresponds to the highest efficiency. For a given head, different combinations of the guide van opening and blade angle have different efficiencies. Therefore, coordinate cam curves are used to describe the relationship between the wicket gate opening and blade angle with different water head. To address these challenges, the manual details a data-driven modeling and learning workflow centered on structured neural networks. The approach is designed to forecast critical operational variables—discharge flow, net head, penstock (or scroll-case) pressure, and generator electrical outputs—by leveraging real-time inputs such as the generator power control setpoint, exciter field current and field voltage, together with hydromechanical commands (e.g., gate position and, when available, runner blade-pitch angle). The neural models are trained and validated on operational data from a Kaplan unit operated by Chelan PUD, demonstrating that the structured NN architecture can learn the coupled gate–blade–electrical dynamics. The result is a robust DT that improves situational awareness and supports data-informed decision-making for Chelan PUD’s Kaplan turbine operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Balanced current-source inverter

A switching circuit for a current source inverter includes a first inverter leg, a second inverter leg, and a controller. The first inverter leg includes a first reverse-voltage-blocking (RB) switch, a second RB switch, and a third RB switch that are connected in series between a first bus line and a second bus line. The second inverter leg includes a fourth RB switch, a fifth RB switch, and a sixth RB switch are connected in series between the first bus line and the second bus line. The controller is configured to control a switch between an on-state and an off-state for each RB switch. When in the on-state, a reverse voltage is blocked by a respective RB switch, and a current with a positive polarity is conducted through the respective RB switch. When in the off-state, a voltage and the current are blocked by the respective RB switch.

Jahns, Thomas Merlin↗

Machine Learning Enabled Position Detection for 6.78 MHz UAV Wireless Power Transfer System

This paper presents a novel supervised machine learning (SML) approach for accurate position detection of the receiver coil in wireless power transfer (WPT) systems using only secondary-side electrical measurements, with applications in autonomous unmanned aerial vehicle (UAV) charging. The proposed method trains a supervised learning model to map measured secondary-side voltage and current features to the receiver’s spatial position with high precision. This enables an autonomous UAV to determine its location relative to the primary coil center, the optimal position for maximizing wireless charging efficiency. The sensing method is fully integrated into a standard WPT system, utilizing the same primary and secondary coils for both power transfer and position detection, thereby eliminating additional sensing hardware. The use of a 6.78 MHz operating frequency enhances positional sensitivity, as high-frequency near-field electromagnetic fields respond strongly to small spatial variations. Experimental validation is performed on a 30 W scaled prototype featuring a 210 mm × 140 mm primary coil, a 50 mm × 80 mm receiver coil, and a 15 mm air gap. Results demonstrate reliable position estimation and a strong correlation between predicted position and optimal coil alignment. This integrated framework unifying position detection and wireless charging offers a promising foundation for future autonomous electric vertical takeoff and landing (eVTOL) systems, enabling compact, hardware-efficient, and high-accuracy charging solutions.

Colak, Kerim [New York University]↗

Impact of K-factor on Short Circuit Program Convergence for Inverter-Based Resources during Faults

Classical short-circuit programs that linearize the power network are no longer applicable for inverter based resources (IBRs), necessitating an iterative approach. Phasor domain programs can model the IBRs using an iterative approach considering nonlinear fault responses. In phasor domain models, the IBR can be modeled as a voltage controlled current source (VCCS) in tabular form with positive, negative, and zero sequence information for balanced and unbalance short-circuit faults. In the VCCS modeling of the IBR, positive and negative incremental reactive current, also known as the k-factor, plays an important role in short circuit program convergence. In this work, a few approaches: conventional VCCS modeling with a k-factor of 2, conventional VCCS modeling with a k-factor of 2 with modified pre-fault voltages, VCCS characteristics based on the power flow solution with a k-factor of 2, and VCCS characteristics based on the power flow solution with a k-factor of 1 are investigated for short circuit program convergence under higher IBR penetration. The IEEE 39 bus New England Test System is taken as the test system, and simulations are carried out in PSS®CAPE 15.0.26 simulation software. Simulation results demonstrate that IBR penetration is higher for the VCCS model, which corresponds to the power flow solution with k-factor 1, compared to other approaches.

42 ENGINEERING↗

Power Decoupling Method for Voltage Source Inverters Using Grid Voltage Modulated Direct Power Control in Unbalanced System

The grid voltage modulated direct power control (GVM-DPC) is a novel power regulation method for grid-connected voltage source inverters (VSI). However, interactions between real and reactive powers still exist in GVM-DPC under unbalanced grid voltage condition, which may deteriorate its transient performance. Here, this article proposes a power decoupling method for GVM-DPC-based VSI in unbalanced systems based on the dynamic feedforward power compensation strategy, which can reduce the coupling magnitudes of real and reactive powers in the transient stages. First, the power coupling mechanism of positive and negative sequence real and reactive powers of VSI under the unbalanced voltage condition is analyzed. Then, the power coupling magnitudes (PCM) are derived according to relationships among the positive sequence components of real power, reactive power and point of common coupling (PCC) voltages. Next, the PCM are compensated into the GVM-DPC for the better decoupling performance. Furthermore, a stability analysis of the proposed control system is studied based on the impedance model, and a comparison with the traditional power decoupling method based on virtual impedance is conducted to show the superiority of the proposed method. Finally, simulations, hardware-in-loop test and experiment are conducted to validate the effectiveness of the proposed method.

42 ENGINEERING↗

Microbial community diversity changes during voltage reversal repair in a 12-unit microbial fuel cell

Microbial fuel cell stacks (MFC-Stack) are often confronted with voltage reversals, likely due to an interplay between microbial community dynamics and insufficient electric circuit balancing. Herein, we provide new insight into voltage reversals by examining the microbiomes of twelve MFC units of a 12-liter Pilot-MFC-Stack during repair. Different biofilm repair methods (self-healing, electrostimulation, and re-acclimatization upon cross-inoculation) were used to evaluate the microbial community response. In addition, MFC-Stack simulation was performed based on Kirchhoff’s Second Law to predict values for source potentials and post-evaluate internal resistances. Analysis of the 16S rRNA amplicon sequencing data suggests that the biofilm repair methods could slowly heal damaged biofilms. Notably, severely voltage reversed MFC units had low electrogen relative abundances (18%) and positive anode potentials, while strong bioanodes and contained more than 50% electrogens and had negative anode potentials. Between-community analyses (beta diversity ordination and multinomial regression) of the voltage reversed MFC units revealed differences among biofilms in contrast to healthy/strong MFC units. Permutational multivariate analysis of variance (PERMANOVA) confirmed that reversed biofilms were, indeed, significantly (p < 0.05) different from stronger ones. Overall, these analyses demonstrated the utility of combining electrotechnical and microbial community analyses, especially beta diversity ordination and multinomial regression, to understand problematic MFC units and the potential success of a biofilm repair method. Finally, thicker biofilms were usually healthier and stronger, although thickness was no guarantee for proper structure and power function as all factors were interdependent. There was an evolutionary trend that strong anodes became stronger/healthier and others weaker. This spontaneous trend has to be considered to avoid irreversible voltage reversals and to repair electrogenic biofilms in an MFC-Stack.

59 BASIC BIOLOGICAL SCIENCES↗

Safety issues of defective lithium-ion batteries: identification and risk evaluation

Lithium-ion batteries inevitably suffer minor damage or defects caused by external mechanical abusive loading, e.g. , penetration, deformation, and scratch without triggering a hard/major short circuit. The replacement of cells becomes a dilemma if the safety risk of the defective batteries remains unknown. Herein, by introducing a representative defect form, i.e. , screw indentation, we demonstrate the safety characteristics of defective batteries. We prove that defective batteries have a significantly increased thermal risk and deteriorated mechanical integrity, but can go undetected due to prompt voltage recovery and insignificant local temperature increase. We discover that the voltage curve within the first few cycles contains sufficient information to identify defective batteries from otherwise good ones and propose methodologies to monitor the cells. Capacity loss and current leakage are two characteristics that can be estimated using the voltage curve. According to the defect size and position, the capacity loss could be 1 to 10 2 mA h and the leakage current could be 5–50 mA. Results remove the barriers for defective battery safety risk evaluation, enabling identification, monitoring, and early warning of minor damaged batteries.

25 ENERGY STORAGE↗

A Virtual Space Vector Model Predictive Control for a Seven-Level Hybrid Multilevel Converter

This paper proposes a virtual space vector (VSV) model predictive control (MPC) for a three-phase seven-level (7L) hybrid multilevel converter (HMC), where each phase consists of an active-neutral-point-clamped converter with a floating H-bridge. To achieve the best current tracking, which is the primary goal of the proposed algorithm, a novel geometrical positioning approach is proposed to select the optimal voltage vector among all the realspace vectors and VSVs. Then, all the possible switching sequences that belong to the optimal voltage vector are evaluated to realize the dc capacitor voltage balancing and common-mode voltage reduction. Through an external modulator, the optimal voltage vector can be synthesized by using either one-, three-, or seven-segment switching sequence. Compared with the conventional MPC, the proposed VSV-MPC can reduce not only the computational burden but also the current THD. Both simulation and experimental results obtained on silicon carbide based 7L-HMC prototype are presented to validate the feasibility and effectiveness of the proposed VSVMPC strategy.

42 ENGINEERING↗

First Principles Determination of the Potential-of-Zero-Charge in an Alumina-Coated Aluminum/Water Interface Model for Corrosion Applications

The surfaces of most metals immersed in aqueous electrolytes have a several-nanometer-thick oxide/hydroxide surface layer. This gives rise to the existence of both metal|oxide and oxide|liquid electrotlyte interfaces, and makes it challenging to correlate atomic length-scale structures with electrochemical properties such the potential-of-zero-charge (PZC). The PZC has been shown to be correlated the onset potential for pitting corrosion. Here, we conduct large-scale Density Functional Theory and ab initio molecular dynamics to calculate the PZC of a Al(111)| γ -Al 2 O 3 (110)| water double-interface model within the context of aluminum corrosion. By partitioning the multiple interfaces involved into binary components with additive contributions to the overall work function and voltage, we predict the PZC to be -1.53 V vs SHE for this model. Furthermore, we calculate the orbital energy levels of defects like oxygen vacancies in the oxide, which are critical parameters in theories associated with pitting corrosion. We predict that the Fermi level at the PZC lies above the impurity defect levels of the oxygen vacancies, which are therefore uncharged at the PZC. From the PZC estimate, we predict the voltage needed to create oxygen vacancies with net positive charges within a flatband approximation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Use of Machine Learning on PMU Data for Transmission System Fault Analysis

Synchrophasor technology has been used for monitoring, control, and protection of bulk power system for over 10 years. Deployment of phasor measurement units (PMUs) in the USA power system has surpassed 3000 units installed in the transmission substations as stand-alone intelligent electronic devices (IEDs) or as a software add-on to other devices such as digital protective relays (DPRs) or digital fault recorders (DFRs). By now, thousands of terabytes of PMU data may have been captured and stored by various transmission system operators (TSOs) and independent system operators (ISOs). This creates an opportunity to deploy advanced machine learning (ML) techniques to detect and classify faults recorded by PMUs automatically to be used by the system operators for rapid, critical decision-making when manual analysis of the past or unfolding events is not feasible. In this paper we offer a brief background on how the automated fault analysis may be done using DPR and/or DFR data, and compare some of the legacy approaches to the new ML approaches in the context of the system-wide PMU recordings. We then offer insights from developing practical ML solutions that have been applied on field recordings captured by close to 450 PMUs from all three US interconnections (Western, Eastern and ERCOT) over two years (2016-2017). We identify and illustrate ML challenges we addressed: inaccurate data, data with scarce and temporally imprecise fault labels, data recorded by PMUs sparsely located at substations resulting in the fault records taken afar from the ends of the faulted lines, data containing only positive sequence values, and data taken at different voltage levels. We then illustrate the ML model results for fault analysis under different application scenarios. The novelty of this study is not only in the design, implementation, and performance analysis of the ML algorithms, but also in the use of advanced fault modelling and simulation approaches to improve the training results when developing supervised ML models for fault detection and classification. Extensive simulations of faults were conducted on a 14-bus power system to create a training dataset with over 1400 accurately labelled faults. This dataset was applied to enhance the accuracy of fault detection and classification of machine learning-based models trained with small number of labelled faults in large datasets recorded in the grid interconnections ranging from 5,000 to 70,000 buses.

Synchrophasors, Machine Learning, Fault Analysis, ↗

Time-resolved electron energy distribution functions at the substrate during a HiPIMS discharge with cathode voltage reversal

Abstract The time-dependent plasma properties of a high-power impulse magnetron sputtering plasma are investigated which include a positive ‘kick’ pulse on the sputtering target 2 μ s after the main negative pulse, this reversing the voltage on the cathode. At a substrate 15 cm distant from the magnetron, the time-dependent electron energy distribution function (EEDF), plasma potential, potential commute time and plasma diffusion properties are measured using a single Langmuir probe. Results show that the positive pulse on the target expels plasma and raises the plasma potential across the chamber on the order of 1 to 2 μ s, which is the time scale of the electron diffusion. The EEDF at the substrate fits a Druyvesteyn distribution during the main negative pulse rising slightly in average energy over time. The distribution is still Druyvesteyn and at the very start of the positive pulse, but then loses the higher energy electrons and drops in average electron energy as the positive pulse progresses. A Boltzmann equation solver, BOLSIG+, was used to predict the EEDF at the substrate during the positive pulse and it agrees best with the measurements assuming a value of 0.2 Td for the E / N (electric field/gas number density).

Physics↗

A Simplified Model Predictive Control Strategy for a Nine-Level Hybrid Multilevel Converter

This paper proposes a simplified model predictive control (SMPC) for a 9-level hybrid multilevel converter based on the active-neutral-point-clamped (ANPC) topology. The proposed SMPC firstly identifies the voltage vector that has optimal current tracking performance by a novel geometrical positioning approach in the complex plane, which can dramatically reduce the computational burden. Then it evaluates the switching states that are subject to the same voltage vector and selects the optimal switching state to balance the dc capacitor voltages. Both simulation and experimental results are carried out to validate the feasibility and effectiveness of the proposed control strategy.

14 SOLAR ENERGY↗

Simplified Two-Stage Model Predictive Control for a Hybrid Multilevel Converter With Floating H-Bridge

This paper proposes a simplified two-stage model predictive control (ST-MPC) for a hybrid multilevel converter, which is an active-neutral-point-clamped converter with floating H-bridge (ANPC-H). The objective of the first stage is to select the voltage vector that has the optimal current tracking performance by using a novel geometrical positioning approach in the complex plane. The second stage selects the best switching state among all the available switching states that belong to the same voltage vector obtained in the first stage, to balance dc capacitor voltages and reduce the common mode voltage. The proposed ST-MPC can dramatically reduce the computational burden and ensure the best current tracking by the two-stage structure, such that the execution time is much shorter compared with the conventional MPC. In addition, the geometrical positioning approach in the first stage is generic and can be applicable for any multilevel converters with N-level output; thus, this ST-MPC can be applied for both sevenand nine-level operation of the hybrid ANPC-H converter under different dc voltage ratios. Both simulation results and experimental results obtained on a silicon carbide hybrid ANPC-H converter prototype validate the feasibility and effectiveness of the proposed ST-MPC strategy.

42 ENGINEERING↗

Electrolytes for high-voltage lithium batteries

Here, in the aim of achieving higher energy density in lithium ion batteries (LIBs), both industry and academia show great interests in developing high-voltage LIBs (>4.3 V). However, increasing the charge cut-off voltage of the commercial LIBs causes severe degradations of both the positive electrode materials and the conventional LiPF 6 -oragnocarbonate electrolytes. Consequently, LIBs using conventional LiPF 6 -organocarbonate electrolytes suffer from a short cycle life when operated at higher charge cut-off voltages. In this review, the aging mechanisms associated with high-voltage LIBs will be analyzed and the countermeasures from the electrolyte design will be discussed.

25 ENERGY STORAGE↗