Search NASA⌕ Search

SEARCH · Search NASA

Results for “Volume of Fluid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Fluvial Volumes, Timescales, and Intermittency in Milna Crater, Mars

Ancient lake deposits and valley networks on Mars provide strong evidence that its surface was once modified by liquid water, but the extent of that modification is still debated. Ancient lacustrine deposits in Milna Crater provide insight into the timescale and fluid volume required to construct fluvially derived sedimentary deposits near the Noachian-Hesperian boundary. Placing the lacustrine deposits their regional context in Paraná Valles provides a quantitative measurement of the intermittency of large, water-mediated sediment transport events in that region.

Buhler, P.↗

Effect of simulated weightlessness on exercise-induced anaerobic threshold

The effect of simulated weightlessness, induced by ten days of continuous bedrest (BR) in the -6 deg head-down position, on the exercise-induced anaerobic threshold (AT) was determined by comparing specific ventilatory and gas-exchange measurements during an incremental ergometer test performed before and after BR. The primary index for determining the exercise-induced AT values of each subject was visual identification of the workrate or oxygen uptake (VO2) at which the ratio of the expired minute ventilation volume (VE) to VO2 exhibited a systematic increase without a concomitant increase in the VE/VCO2 value. Following BR, the mean VO2max of the subjects decreased by 7.0 percent, and the AT decreased from a mean of 1.26 L/min VO2 before BR to 0.95 L/min VO2 after BR. The decrease in AT was manifested by a decrease in both absolute and relative workrates. The change in AT correlated significantly with the change in plasma volume but not with the change in VO2max. The results suggest that the reduction in AT cannot be completely explained by the reduction in VO2, and that the AT decrease is associated with the reduction in intravascular fluid volume.

Convertino, V. A.↗

Venous compliance and fluid shift measurements on Spacelab IML-1

During the first few hours of a human spaceflight mission, a headward fluid shift out of the abdomen, pelvis, and legs initiates a number of adaptive cardiovascular responses, including a loss of intravascular and extravascular fluid volume. On return to earth, these cardiovascular changes may lead to debilitating symptoms of orthostatic intolerance in an unprotected astronaut. To test the hypothesis that an inflight increase in compliance of the leg veins may contribute to this condition, measurements of lower leg fluid shift and bulk venous compliance were collected from crew members during the eight-day First International Microgravity Laboratory shuttle mission. An ultrasonic limb plethysmograph, in conjunction with two compression cuffs encircling the calf and thigh, was used to determine bulk compliance of the underlying veins over a range of negative and positive transmural pressures. The data from inflight experiment sessions were compared to preflight and postflight sessions. The preliminary results indicate that the volume of the lower leg decreased by over 10 percent by the sixth day of flight, but there was no apparent change in venous compliance.

Leiski, D.↗

Reversible Colorimetric Sensing of Volatile Analytes By Wicking in Close Proximity to A Photonic Film

Isolation of volatile analytes from environmental or biological fluids is a rate-determining step that can delay the response time for continuous sensing. In this paper, we demonstrate a colorimetric sensing system that enables the rapid detection of gas-phase analytes released from a flowing micro-volume fluid sample. The sensor platform is an analyte-responsive metal-insulator-metal (MIM) thin-film structure integrated with a large area quartz micropillar array. This allows precise planar alignment and microscale separation (310 μm) of the optical and fluidic structures. This configuration offers rapid and homogeneous color changes over large areas that permits detection by low-resolution optics or eye, which is well-suited to portable/wearable devices. For our proof-of-principle demonstration, we utilized a poly(methyl methacrylate) (PMMA) spacer and evaluated the sensor's response (color change) to ethanol vapor. We show that the RGB color value is quantitatively linked to the spacer swelling, which is reversible and repeatable. The optofluidic platform reduces the sensor response time from minutes to seconds compared with experiments using a conventional chamber. The sensor's concentration-dependent response was examined, confirming the potential of the reported sensing platform for continuous, compact, and quantitative colorimetric analysis of volatile analytes in low-volume samples, such as biofluids.

Timothy J. Palinski↗

Structural Requirements and Scaling Analysis of a Fluidic Mirror Space Telescope Support Structure

The NASA FLUTE project proposes large-scale (50m) fluidic telescopes for astronomy applications. To continue to explore the universe, astronomers require larger and larger telescope apertures. The highest priority astrophysics targets such as exoplanets and early galaxies are extremely faint, motivating larger telescope apertures. However, mission costs depend on aperture diameter, and scaling apertures beyond 10-m apertures faces economic and technological viability challenges. An unsegmented primary mirror made in space via fluidic microgravity shaping would provide a scalable and cost-effective method to scale apertures to 50-m scale while achieving sub-nanometer (root mean square) surface quality. Such microgravity fluidic shaping has been demonstrated in laboratory neutral buoyance environments, parabolic microgravity experiments, as well aboard the International Space Station. One of the main components of a fluidic observatory is the mirror frame. The frame must provide a stable bounding circular ring which the edges of the fluid mirror surface can wet. The frame can optionally provide a ‘floor’ surface on the interior of the ring to provide additional fluid support and reduce required fluid volume. In this work, we evaluate several classes of structural frame architectures potentially suitable for a fluidic telescope support structure. We start by estimating stability requirements, orbital, station keeping, and slew loads based on a notional CONOPS. The scaling of overall fluid mass required for each architecture is evaluated. Preliminary results elucidate the importance of a support floor for overall mission viability above 10-m diameter. We then investigate the scaling of a tetrahedral truss frame support structure. We show that segmented solid shell support surfaces can provide sufficient stability at modest mass fractions. We estimate that the total fluid and frame mass for a 50-m telescope could be on the order of 15,000 kg. Finally, implementation considerations are discussed, including deployment/assembly methodologies. The results of this study establish feasibility of a large-scale fluidic telescope and will guide further architecture development and detailed structural design.

Christine Gregg↗

Renal sodium reabsorption following induction of and recovery from volume expansion

In the rat, infusion of a volume of isotonic saline equal to 2% of body weight resulted in an 82% increase in the delivery of filtrate out of the proximal tubule but little or, in some animals, no change in the urinary excretion of sodium. By contrast, further degrees of volume expansion resulted in lesser increases in the distal delivery of filtrate, but were associated with a marked increase in the urinary excretion of sodium. Sixty minutes following completion of volume expansion, while the animals were still in positive sodium balance, the urinary excretion of sodium decreased 52% compared to a decrease of only 24% in the distal delivery of filtrate. During the course of progressive volume expansion and during the recovery phase, there was a dissociation between alterations in sodium reabsorption in the proximal convoluted tubule and in the whole kidney. These studies indicate that although the proximal tubule is more sensitive to changes in the extracellular fluid volume, distal nephron sites are ultimately responsible both for the natriuresis of volume expansion and the relative antinatriuresis of the recovery periods.

Knight, T. F.↗

Cardiovascular effects of weightlessness and ground-based simulation

A large number of animal and human flight and ground-based studies were conducted to uncover the cardiovascular effects of weightlessness. Findings indicate changes in cardiovascular function during simulations and with spaceflight that lead to compromised function on reambulation and/or return to earth. This altered state termed cardiovascular deconditioning is most clearly manifest when in an erect body state. Hemodynamic parameters inidicate the presence of excessive tachnycardia, hypotension (leading to presyncope in one-third of the subjects), decreased heart volume, decreased plasma and circulating blood volumes and loss of skeletal muscle mass, particularly in the lower limbs. No clinically harmful effects were observed to date, but in-depth follow-ups were limited, as was available physiologic information. Available data concerning the causes for the observed changes indicate significant roles for mechanisms involved with body fluid-volume regulation, altered cardiac function, and the neurohumoral control of the control of the peripheral circulation. Satisfactory measures are not found. Return to preflight state was variable and only slightly dependent on flight duration. Future progress awaits availability of flight durations longer than several weeks.

Sandler, Harold↗

A Geometric Volume of Fluid-Based Multiphase Flow Solver Extension to the Reacting Flow Solver, PeleLM

A new algorithm is presented to simulate multiphase flows with surface tension in a pathway for spray combustion simulation. The algorithm combines capabilities from two open-source packages, including the interface reconstruction library (IRL), a library of computational geometry routines to enable the volume of fluid (VOF) method, and PeleLM, a solver for the reacting Navier-Stokes equations. Additionally, surface tension is implemented using the continuum surface force (CSF) model with an improved height function technique in the volume fraction field. Spurious errors in volume fraction arising from our combined strategy are corrected through a topology-based method that improves both numerical stability and accuracy. Multiple validation simulations are conducted, including (i) translations and rotations of Zalesak's disk, (ii) a stationary circular droplet with surface tension, (iii) an oscillating elliptical droplet, and (iv) three-dimensional deformation of a spherical droplet. Results indicate that the combined scheme retains the favorable properties of each of the component algorithms.

42 ENGINEERING↗

Mechanism for negative water balance during weightlessness An hypothesis

The mechanism for the apparent decrease in body fluid volume in astronauts during spaceflight remains obscure. The widespread postulate that the hypohydration is the result of the Henry-Gauer reflex, a diuresis caused by inhibition of vasopressin secretion resulting from increased left and perhaps right atrial (central) venous pressure, has not been established with direct measurements on astronauts. An hypothesis is proposed to account for fluid-electrolyte shifts during weightlessness. A moderate but transient increase in central venous pressure occurs when orbit is entered that is insufficient to activate the Henry-Gauer reflex but sufficient to stimulate the release of atrial natriuretic peptides. Increased sodium excretion would facilitate some increased urinary water loss. The resulting relatively dilute plasma and interstitial fluids would cause fluid to shift into the cellular space, resulting in edema in the head and trunk and inhibition of thirst and drinking. Thus, the negative water balance in astronauts would be caused by a gradual natriuresis and diuresis coupled with reduced fluid intake.

Greenleaf, J. E.↗

Beta-Adrenergic Blockade Does not Prevent Polycythemia or Decrease in Plasma Volume in Men at 4300 m Altitude

When humans ascend to high altitude (ALT) their plasma volume (PV) and total blood volume (BV) decrease during the first few days. With continued residence over several weeks, the hypoxia-induced stimulation of erythropoietin increases red cell production which tends to restore BV. Because hypoxia also activates the beta-adrenergic system, which stimulates red blood cell production, we investigated the effect of adrenergic beta-receptor inhibition with propranolol on fluid volumes and the polycythemic response in 11 healthy unacclimatized men (21-33 years old exposed to an ALT of 4300 m (barometric pressure 460 Torr) for 3 weeks on Pikes Peak, Colorado. PV was determined by the Evans blue dye method (PV(sub EB)), BV by the carbon monoxide method (BV(sub CO)), red cell volume (RCV)was calculated from hematocrit (Hct) and BV(sub CO), and serum erythropoietin concentration ([EPO]) and reticulocyte count, were also determined. All determinations were made at sea level and after 9-11 (ALT-10) and 9-20 (ALT-20) days at ALT. At sea level and ALT, six men received propranolol (pro, 240 mg/day), and five received a placebo (pla). Effective beta-blockade did not modify the mean (SE) maximal values of [EPO] [pla: 24.9 (3.5) vs pro: 24.5 (1.5) mU/ml] or reticulocyte count [pla: 2.7 (0.7) vs pro: 2.2 (0.5)%]; nor changes in PV(sub EB)[pla: -15.8 (3.8) vs pro: -19.9 (2.8)%], RCV(sub CO) [pla: +7.0 (6.7) vs pro: +10.1 (6.1)%], or BV(sub CO) [pla: -7.3 (2.3) vs pro: -7.1 (3.9)%]. In the absence of weight loss, a redistribution of body water with no net loss is implied. Hence, activation of the beta-adrenergic system did not appear to affect the hypovolemic or polycythemic responses that occurred during 3 weeks at 4300 m ALT in these subjects.

Grover, R. F.↗

Physiological water model development

The water of the human body can be categorized as existing in two main compartments: intracellular water and extracellular water. The intracellular water consists of all the water within the cells and constitutes over half of the total body water. Since red blood cells are surrounded by plasma, and all other cells are surrounded by interstitial fluid, the intracellular compartment has been subdivided to represent these two cell types. The extracellular water, which includes all of the fluid outside of the cells, can be further subdivided into compartments which represent the interstitial fluid, circulating blood plasma, lymph, and transcellular water. The interstitial fluid surrounds cells outside of the vascular system whereas plasma is contained within the blood vessels. Avascular tissues such as dense connective tissue and cartilage contain interstitial water which slowly equilibrates with tracers used to determine extracellular fluid volume. For this reason, additional compartments are sometimes used to represent these avascular tissues. The average size of each compartment, in terms of percent body weight, has been determined for adult males and females. These compartments and the forces which cause flow between them are presented. The kidneys, a main compartment, receive about 25 percent of the cardiac output and filters out a fluid similar to plasma. The composition of this filtered fluid changes as it flows through the kidney tubules since compounds are continually being secreted and reabsorbed. Through this mechanism, the kidneys eliminate wastes while conserving body water, electrolytes, and metabolites. Since sodium accounts for over 90 percent of the cations in the extracellular fluid, and the number of cations is balanced by the number of anions, considering the renal handling sodium and water only should sufficiently describe the relationship between the plasma compartment and kidneys. A kidney function model is presented which has been adapted from a previous model of normal renal function in man. To test the validity of the proposed kidney model, results predicted by the model will be compared to actual data involving injected or ingested fluids and subsequent urine flow rates. Comparison of the model simulation to actual data following the ingestion of 1 liter of water is shown. The model simulation is also shown with actual data following the intravenous infusion of hypertonic saline.

Doty, Susan↗

Pros and Cons of Using Water Immersion to Simulate Physiological Responses to Microgravity

Head-out water immersion (HOI) has been employed as a remedial treatment for various ills and ailments for many millennia, and total body immersion even longer as protective encapsulation for the mammalian fetus. Two discrete differences between stimuli induced by true microgravity (10(exp -4) g) and HOI are readily apparent. External water pressure on the skin and accompanying negative pressure breathing cause blood to shift headward. Secondly, the gravitational force is ever present during immersion and microgravity, but its effect is essentially neutralized during Earth orbital flight. Thus, the physiological responses to immersion should not be expected to match those during microgravity. Immersion has been used mainly to study and understand kidney function and associated cardiovascular responses for control of body fluid volume and osmotic content, with some application to and simulation of microgravity responses. There is a plethora of data from human HOI studies, but relatively few controlled data from microgravity studies. In general, it appears that physiological responses occur more quickly with water immersion than in microgravity, but this may be due to less rigorous control (voluntary and involuntary) of the preflight state of crew members. The central venous pressure-vasopressin (Gauer-Henry) reflex control for fluid balance may not be of prime importance in microgravity. Gross functions such as reduced body weight and water, level of hypovolemia, decreased isokinetic strength, and lower nitrogen balance found during immersion are qualitatively similar in microgravity, but the mechanisms controlling these and other functions are, for the most part, unclear. Only acquisition of data from well-controlled microgravity experiments will resolve this discrepancy.

Greenleaf, J. E.↗

Changes in plasma volume during bed rest - Effects of menstrual cycle and estrogen administration

The effect of increased blood estrogen concentration, caused either during normal menstrual cycles or by exogenous administration of premarin, on the bed-rest (BR) induced decrease in plasma volume (PV) was investigated. In women who underwent duplicate 11-day BR without estrogen supplementation, the PV was found to decrease significantly, during the first 5 days of BR, to a lower level at which it remained for the rest of the BR period. In women who began BR in the periovulatory stage of the menstrual cycle, the loss of PV was delayed, while women who began BR during other stages of the cycle exhibited the usual trend of the PV decrease during the BR. In women who underwent a single 12-day BR period while taking premarin (1.25 mg/day), PV was found to decrease during the first 4-5 days of BR, but then returned toward the pre-BR level during the remainder of the BR, indicating that estrogens have a role in stabilizing body fluid volume.

Fortney, S. M.↗

Development of a model to assess orthostatic responses

A major change for crewmembers during weightlessness in microgravity is the redistribution of body fluids from the legs into the abdomen, thorax, and head. The fluids continue to be sequestered in these areas throughout the flight. Upon reentry into gravity on landing, these same body fluids are displaced again to their normal locations, however, not without hazardous incidence to the crewmembers. The problem remains that upon landing, crewmembers are subject to orthostasis, that is, the blood flowing into the legs reduces the blood supply to the brain and may result in the crewmember fainting. The purpose of this study was to develop a model of testing orthostatic responses of blood pressure regulating mechanisms of the cardiovascular system, when challenged, to maintain blood pressure to the brain. To accomplish this, subjects' responses were assessed as they proceeded from the supine position of progressive head-up tilt positions of 30 deg, 60 deg, and 90 deg angles. A convenience sample consisted of 21 subjects, females (N=11) and males (N=10), selected from a list of potential subjects available through the NASA subject screening office. The methodology included all non-invasive measurements of blood pressure, heart rate, echocardiograms, cardiac output, cardiac stroke volume, fluid shifts in the thorax, ventricular ejection and velocity times, and skin blood perfusion. The Fischer statistical analysis was done of all data with the significance level at .05. Significant differences were demonstrated in many instances of changes of posture for all variables. Based on the significance of the findings of this study, this model for assessing orthostatic responses does provide an adequate challenge to the blood pressure regulatory systems. While individuals may use different adaptations to incremental changes in gravity, the subjects, in aggregate, demonstrated significant adaptive cardiovascular changes to orthostatic challenges which were presented to them.

Rubin, Marilyn↗

Growth-induced Donnan exclusion influences swelling kinetics in highly charged dynamic polymerization hydrogels

Polymeric gels crosslinked by DNA sequences can exploit DNA strand-displacement reactions to promote swelling through dynamic polymerization. The degree of swelling and the rate of swelling must be directly tunable to achieve the promise of programmable soft matter. Though the kinetics of the strand-displacement reaction provide insertion rates up to 10 4 /Molar/second as measured in bulk solution, DNA hydrogel swelling can take upwards of 30 h to complete. Computational modeling of the reaction-induced swelling of these gels with our recently-developed reactive electrochemomechanical theory (Zimmerman et al., 2024) suggests that their extraordinarily slow swelling is partly due to a scaling mismatch between the addition of charge and the addition of fluid volume, leading to a large transient increase in the fixed charge density. The significant increase in the gel’s fixed charge density, due to the binding of negatively charged DNA, sharply restricts the concentration of mobile hairpins through the phenomenon of Donnan charge exclusion, an effect commonly exploited in nanofiltration applications using polymeric membranes. The scaling problem is overcome when the mean additional swelling provided to the hydrogel by addition of a crosslink is above a critical value, thus the swelling outpaces the charge accumulation, leading the fixed charge density to drop and significantly accelerating the swelling process. This study shows that Donnan exclusion can explain the kinetics of DNA hydrogel swelling, and studies ways to modulate the reaction speed by either modifying the salt concentration or increasing or decreasing the number of base pairs in each DNA sequence.

42 ENGINEERING↗

Interpreting strain tensor data to characterize and monitor reservoirs for CO2 storage and other applications

Recent advances in instrumentation have made it feasible to measure the transient strain tensor caused by small changes in fluid volume or pressure in the subsurface and this has opened the door to new opportunities for characterization and monitoring. We have deployed strainmeters and then conducted injection well tests in an underlying reservoir at 530m depth. The resulting data indicated that the horizontal strain at shallow strainmeters (30 to 40m depth) was tensile and the vertical strain was compressive. The radial strain was less than the horizontal strain, and the strain rates decreased from 100 nanostrain/day to roughly 10 n/d over a few days. The signal at two strainmeters at shallow depth were consistent, although the magnitude of the horizontal strains were different reflecting the different radial directions from the well. The signal at a deep strainmeter deployed at reservoir depth was much different, with tensile vertical strains and compressive horizontal strains. These data can be interpreted by inverting poroelastic forward models developed using numerical and analytical methods. The average horizontal strain in the caprock resembles the transient pressure in the underlying reservoir and classic type-curve methods from transient well testing can be used for preliminary interpretations of strain data. We have developed closed-form analytical solutions to a pressurized poroelastic inclusion and inhomogeneity in a half-space. This model is fast and can be inverted to estimate reservoir stiffness and geometry. Numerical models developed using finite element methods allow more details of the subsurface to be included in the inversion, but they require much longer run times and this makes inversion cumbersome using standard methods. We have developed an inversion approach that uses a proxy model created using machine learning to do most of the forward calculations. The proxy model is periodically updated and refined using the finite element model to ensure accuracy. This approach significantly reduces the computational requirements and makes it feasible to use Bayesian inversion with large numerical models. We have shown that the strain tensor in the caprock is sensitive to pressure in the reservoir, boundaries in the reservoir, and pressure in the caprock caused by leaks. These results indicate that coupling strain tensor data with inversion has the potential to help evaluate reservoirs during initial characterization, and to monitor them during the CO2 injection and storage process.

Murdoch, Larry↗

Segmented ball valve is easy to open and close

Segmented ball valve and flowmeter in the same spherical housing provide a valve that will handle large fluid volume without bulkiness and weight of blade valves or conventional ball valves. The valve is easily opened or closed and the flowmeter remains stationary, so errors are eliminated.

Prono, E.↗