Search NASA⌕ Search

SEARCH · Search NASA

Results for “WFIRST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

WFIRST Grism Characterization

We had presented the optical design and early test result of WFIRST grism spectrometer in previous SPIE conferences. This paper reports the follow-on activity of the spectral and radiometric calibrations, including the calibration methods, experiment designs, and test equipment calibration, such as the light source and detectors used in the test. The real grism calibration includes the throughput versus wavelength, which is largely determined by the diffraction efficiency of the two diffractive surfaces. It also includes spectral resolution, point spread function, and encircle energy measurements. The measured data are presented. The comparisons between the test data and the simulation from theory or optical model are also presented.

Optics↗

Demonstration of Multi-Star Wavefront Control for WFIRST, Habex, and LUVOIR

Coronagraphic instruments will enable direct imaging of dim planetary companions around nearby stars. The majority of nearby FGK stars are located in multi-star systems, including the Alpha Centauri stars, which may represent the best quality targets available for spectroscopic characterization due to their proximity and brightness. However, a binary system exhibits additional leakage from the o -axis companion star that may be brighter than the target exoplanet. Multi-Star Wavefront Control (MSWC) is a wavefront-control technique that allows simultaneous suppression of starlight of both stars in a binary system. MSWC would thus enable direct imaging of circumstellar planets in binary star systems such as Alpha Centauri. MSWC is compatible with a wide suite of planned coronagraphic instruments for future space missions. As part of the technology demonstration e orts for MSWC, the rst milestone results are presented here demonstrating (via computer simulations), high-contrast imaging capabilities of multi-star systems for several instruments including: [1] the upcoming WFIRST and its CGI demonstrator, [2] the HABitable Worlds EXplorer (Habex) mission concept, [3] the segmented Large UV/Optical/IR (LUVOIR) mission concept, and [4] a small-aperture Alpha Centauri direct-imager mission concept. For each of these missions, a baseline coronagraph option planned for the mission will be adopted and instrument baseline performance will be compared for single-star wavefront control.

Sirbu, Dan↗

Exoplanet Imaging with CHARIS and Future Synergies with WFIRST CGI

The principal science goal of directly imaging exoplanets is spectroscopy. At Subaru, the SCExAO instrument uses the CHARIS integral field spectrograph (IFS) to take spectra of young, self-luminous companions and disks in the near-infrared. CHARIS provides both R70 and R20 spectral resolutions across the J, H, and K bands. Of the two, R20 is the primary observing mode, which provides both excellent spectral coverage of the companions and a larger bandpass for advanced speckle subtraction techniques. Looking to the future, the WFIRST CoronaGraph Instrument (CGI) is a technology demonstration for future missions whose spectroscopic techniques are rooted in what has been demonstrated at ground observatories. CGI will reach very high contrast in broadband light with advanced wavefront control and coronagraphy techniques, paving the way for characterizing Earth-like planets. The spectral resolution of CGI spectroscopic modes is R50 with 15% bandpasses from 600 to 970nm. The calibration, speckle subtraction, and spectral extraction methods for CGI spectroscopy has a strong heritage from techniques developed for SCExAO+CHARIS. We discuss such synergies between CHARIS and CGI characterization capabilities from both a science and engineering perspective, including the new Wollaston polarization upgrade to CHARIS.

Groff, Tyler D.↗

Narrowband Rejection of Reaction Wheel and Environmental Disturbances for the WFIRST OMC Testbed

The Wide Field Infrared Survey Telescope (WFIRST) is a NASA observatory with two scientific instruments. The first is the Wide Field Instrument (WFI) designed to perform wide field imaging and surveys of the near infrared (NIR) sky. The second is a coronagraph (CGI) that will enable astronomers to detect and measure properties of planets in other solar systems. The coronagraph requires 0.5 milli-arcsecond (mas) RMS pointing per axis of the line of sight (LOS) to achieve a contrast of 1x10-9. This paper discusses the approach used for achieving this level of pointing performance on the occulting mask coronagraph (OMC) testbed at JPL. This testbed uses a low-order wavefront sensing (LOWFS) camera and fast steering mirror (FSM) to suppress injected LOS jitter and environmental LOS jitter. The injected jitter includes representative broadband spacecraft attitude control system (ACS) LOS motion and tonal LOS jitter caused by the reaction wheel assemblies (RWA). The environmental jitter includes thermal LOS variations and harmonics of the line noise. The LOWFS camera uses high flux from the obscured science target to achieve high rate measurements of the LOS. These measurements are augmented with fictitious RWA tachometer information and an estimate of the line noise frequency. A LOS servo using a combination of feedback and feedforward control is used in the testbed to compensate for all of the disturbance sources and to mitigate jitter caused by in-band camera noise. The feedforward uses a novel robust least mean squares (RLMS) filter algorithm to reject the RWA and line frequency tones. High fidelity models of the sensors, disturbances and actuator are presented in this paper. These models were developed as part of a simulation of the LOS control system. Performance results from the hardware testbed at the Jet Propulsion Laboratory (JPL) are discussed in this paper.

Shields, Joel↗

WFIRST CGI: Prism and Polarizer Characterization Modes

As part of its technology demonstration, the WFIRST coronagraph instrument (CGI) will demonstrate point source spectroscopy and polarization measurements of disks. The specific implementation of spectroscopy is a zero-deviation Amici prism and slit to be placed on the planet after high contrast has been achieved by CGI. The polarization optics are a set of Wollaston prisms so that orthogonal polarization states can be measured simultaneously. The CGI spectral characterization mode, being designed and built and Goddard Space Flight Center (GSFC), has a spectral resolution of R50 and is designed to accommodate a 15% bandpass spanning 610-785nm. In order to recover Stokes information, there are two sets of Wollaston prisms clocked 45 degrees with respect to one another with each measurement taken in series. The Wollaston design and optical elements are a contribution by the Japanese Aerospace Exploration Agency, with final alignment and testing being done at GSFC. The spectroscopy mode is designed to target Methane absorption features around 730nm, keeping the spectral resolution as low as possible to improve the signal-to-noise ratio and hence reduce detection time. We highlight the requirements for these modes and address the challenge of on-orbit spectral calibration for a deployable slit in the presence of pointing drifts. Of unique interest is how the observatory error budget couples into good stellar spectrum calibration and subsequent speckle subtraction. We also provide further detail on the optomechanical design, its stability based on thermal and structural predictions, modeled performance, and operations concept. These performance metrics are simulated to demonstrate how a slit located at an arbitrary field point is homed onto the planet and converted to a calibrated spectrum.

Tyler D Groff↗

WFIRST coronagraph optical modeling

End-to-end numerical optical modeling of the WFIRST coronagraph incorporating wavefront sensing and control is used to determine the performance of the coronagraph with realistic errors, including pointing jitter and polarization. We present the performance estimates of the current flight designs as predicted by modeling. We also describe the release of a new version of the PROPER optical propagation library, our primary modeling tool, which is now available for Python and Matlab in addition to IDL.

Zhou, Hanying↗

The WFIRST Coronagraph Instrument Optical Design Update

The WFIRST Coronagraph Instrument will perform direct imaging of exoplanets via coronagraphy of the host star. It uses both the Hybrid Lyot and Shaped Pupil Coronagraphs to meet the mission requirements. The Phase A optical design fits within the allocated instrument enclosure and accommodates both coronagraphic techniques. It also meets the challenging wavefront error requirements. We present the optical performance including throughput of the imaging and IFS channels, as well as the wavefront errors at the first pupil and the imaging channel. We also present polarization effects from optical coatings and analysis of their impacts on the performance of the Hybrid Lyot coronagraph. We report the results of stray light analysis of our Occulting Mask Coronagraph testbed.

Zhao, Feng↗

High Accuracy Coronagraph Flight Model For WFIRST–CGI Raw Contrast Sensitivity Analysis

A high-accuracy high-fidelity flight wavefront control (WFC) model is developed for detailed raw contrast sensitivity analysis of WFIRST-CGI. Built upon features of recently testbed validated model, it is further refined to combine a full Fresnel propagation diffraction model for high accuracy contrast truth evaluation, and an economical compact model for WFC purposes. Extensive individual raw contrast error sensitivities are evaluated systematically, both as known imperfections and as unknown calibration errors, for both spectroscopy mode and wide field-of-view mode with shaped pupil coronagraph. More than 90 distinct error items were identified, including system aberrations, optical misalignment, component manufacturing error, telescope interface related errors, etc. The result forms the basis for raw contrast error budget flow down to a sub-system level, where detailed specifications needed to aid in component design and manufacturing, mechanical alignment and instrument integration, and verification and validation operations. Evaluations are mostly automated, making it relatively easy for repeat runs of revised design or at new desired error quantity. Top error sensitivities and contrast floor contributors are discussed and several observations are noted.

Poberezhskiy, Ilya↗

WFIRST Coronagraph Detector Trap Modeling Results and Improvements

The WFIRST coronagraph is being designed to detect and characterize mature exoplanets through the starlight reflected from their surfaces and atmospheres. The light incident on the detector from these distant exoplanets is estimated to be on the order of a few photons per pixel per hour. To measure such small signals, the project has baselined the CCD201 detector made by e2v, a low-noise and high-efficiency electron-multiplying charge-coupled device (EMCCD), and has instituted a rigorous test and modeling program to characterize the device prior to flight. An important consideration is detector performance degradation over the proposed mission lifetime due to radiation exposure in space. To quantify this estimated loss in performance, the project has built a detector trap model that takes into account detailed trap interactions at the sub-pixel level, including stochastic trap capture and release, and the deferment of charge into subsequent pixels during parallel and serial clocking of the pseudo-two-phase CCD201 device. This paper describes recent detector trap model improvements and modeling results.

Holland, Andrew↗

WFIRST Coronagraph Flight Performance Modeling

As it has for the past few years, numerical modeling is being used to predict the on-orbit, high-contrast imaging performance of the WFIRST coronagraph, which was recently defined to be solely a technology demonstrator. A consequence has been a realignment of modeling priorities and revised applications of modeling uncertainty factors and margins, which apply to multiple factors such as pointing and wavefront jitter, thermally-induced deformations, polarization, and aberration sensitivities. At the same time, the models have increased in fidelity as additional parameters have been added, such as time-dependent pupil shear and mid-spatial-frequency deformations of the primary and secondary mirrors, detector effects, and reaction-wheel-speed-dependent pointing and wavefront jitter.

Trauger, John↗

WFIRST Coronagraph: Digging Dark-Holes with Partially Corrected Pupil Phase

The WFIRST coronagraph employs two sequential deformable mirrors to compensate for phase and amplitude errors in the coronagraph optical system. In such a system the actuators of the deformable mirrors would be used for two purposes: To flatten the overall wavefront errors at a system pupil, and to create "dark-holes". The actuators have limited stroke ranges. Therefore, if the pupil phase errors are relatively large, flattening them completely could use up a significant portion of the actuator stroke, sometimes leaving insufficient stroke for creating the dark-holes. We have investigated the impact of partially-corrected pupil phase errors on a Hybrid Lyot Coronagraph (HLC) broadband contrast performance. The predicted broadband contrast floor and the contrast chromaticity agree well with those measured on the HLC testbed.

Poberezhskiy, Ilya↗

Laboratory Testbed Verification of Data Post-Processing Strategies for the WFIRST Coronagraph Instrument

One of the objectives of the WFIRST Coronagraph Instrument is to demonstrate post-processing algorithms for space-based exoplanet imaging data in the regime of very high contrast ratios (< 1E-8). We analyzed two 15-hour time series of laboratory images acquired with prototype coronagraph designs on a vacuum chamber testbed at JPL. These data sets enabled us to test the performance of reference differential imaging (RDI) PSF subtraction as a function of time and Euclidean (L2) speckle pattern distance. Starting from an analytical relationship between speckle pattern stability and classical subtraction gain, we compared the classical subtraction result to those of the KLIP RDI algorithm. In both data sets, KLIP RDI contrast gains are typically 3-4× greater than those of classical subtraction. These results suggest that a diverse reference PSF library will enable a significant gain in sensitivity beyond that suggested by the raw, frame-to-frame speckle pattern stability.

Ygouf, Marie↗

The WFIRST Coronagraph Instrument: A Major Step in the Exploration of Sun-Like Planetary Systems Via Direct Imaging

The Wide Field Infrared Survey Telescope (WFIRST) Coronagraph Instrument (CGI) will be the first high-performance stellar coronagraph using active wavefront control for deep starlight suppression in space, providing unprecedented levels of contrast and spatial resolution for astronomical observations in the optical. One science case enabled by the CGI will be taking visible images and (R~50) spectra of faint interplanetary dust structures present in the habitable zone of nearby sunlike stars (~10 pc) and within the snow-line of more distant ones (~20 pc), down to dust brightness levels commensurate with that of the solar system zodiacal cloud. Reaching contrast levels below 10-7 at sub-arcsecond angular scales for the first time, CGI will cross an important threshold in debris disks physics, accessing disks with low enough optical depths that their structure is dominated by transport mechanisms rather than collisions. Hence, CGI will help us understand how exozodiacal dust grains are produced and transported in low-density disks around mature stars. Additionally, CGI will be able to measure the brightness level and constrain the degree of asymmetry of exozodiacal clouds around individual nearby sunlike stars in the optical, at the ~3x solar zodiacal emission level. This information will be extremely valuable for optimizing the observational strategy of possible future exo-Earth direct imaging missions, especially those planning to operate at optical wavelengths as well, such as the Habitable Exoplanet Observatory (HabEx) and the Large Ultraviolet/Optical/Infrared Surveyor (LUVOIR).

Demers, R.↗

Lessons for WFIRST CGI from Ground-Based High-Contrast Systems

The Coronagraph Instrument (CGI) for NASA’s Wide Field Infrared Survey Telescope (WFIRST) will constitute a dramatic step forward for high-contrast imaging, integral field spectroscopy, and polarimetry of exoplanets and circumstellar disks, aiming to improve upon the sensitivity of current ground-based direct imaging facilities by 2–3 orders of magnitude. Furthermore, CGI will serve as a pathfinder for future exo-Earth imaging and characterization missions by demonstrating wavefront control, coronagraphy, and spectral retrieval in a new contrast regime, and by validating instrument and telescope models at unprecedented levels of precision. To achieve this jump in performance, it is critical to draw on the experience of ground-based high-contrast facilities. We discuss several areas of relevant commonalities, including: wavefront control, post-processing of integral field unit data, and calibration and observing strategies.

Xuan, Wenhao↗

Development of the WFIRST CGI Integral Field Spectrograph

The principal science goal of directly imaging exoplanets is spectroscopy. Future mission concepts such as LU- VOIR and HabEx have baselined their science instruments to use an integral field spectrograph (IFS) to maximize observing efficiency. Coronagraphic imaging with an IFS has strong heritage at ground observatories, having produced planet and brown dwarf near-infrared spectra at contrast floors as low as high 1 × 10-6 levels. As a technology demonstration for future missions the WFIRST coronagraph instrument (CGI) will demonstrate the ability to measure spectra in visible light with at contrast levels sufficient for detecting Earth-like planets. The spectrograph was originally meant to match that of future missions; an independent IFS channel for wavefront control and imaging spectroscopy. Due to a series of de-scopes as the project progressed, the baseline spectroscopic capability of CGI is no longer an IFS but a zero deviation optical prism and slit used in conjunction with the direct imaging camera. Regardless, CGI advanced a lenslet IFS through the preliminary design phase of a flight project. Here we present that development as the challenges and requirements of an IFS for coronagraphy are quite unique and relevant to future missions. With that development in place, we also present the initial design of the zero optical deviation prism, highlighting the relative challenges and performance of each concept.

Tyler D Groff↗

The WFIRST CGI Integral Field Spectrograph: Requirements and Performance Predictions

The WFIRST coronagraphic instrument (CGI) will demonstrate exoplanet spectroscopy using an integral field spectrograph (IFS). The CGI IFS, being designed and built at Goddard Space Flight Center, has a spectral resolution of R50 and is designed to accommodate a 20% bandpass spanning 600- 970 nm. The IFS is principally targeting the abundance of Methane features, with the primary coronagraph band being centered around 770nm. Key to the performance estimates are the achievable signal-to-noise (SNR) ratios and the stability of the microspectra over the course of tens and hundreds of hours. As a technology demonstration for CGI, the ability to close a wavefront control loop around the IFS, maintain a stable dark hole, and provide time resolved data that simultaneously spans spatial and spectral dimensions are crucial demonstrations for future observatories. The IFS is optimized both for coronagraphs and science observations with a potential future starshade. We highlight how the long duration observations, and requirements for both starshades and coronagraphs drive the IFS requirements and the calibrations required both onorbit and on the ground. We also provide further detail on the optomechanical design, its stability based on thermal and structural predictions, anticipated performance, and operations concept of the CGI IFS. The impact of these performance metrics are projected into simulated data products, demonstrating cube extraction of noisy images and the subsequent planet spectrum that can be extracted from them. These demonstrations and performance predictions are key to future missions such as LUVOIR and HabEx, whose principal science case relies on efficient spectroscopy of exoplanets.

Tyler Groff↗

Bubble Mapping with the Square Kilometre Array - I. Detecting Galaxies with Euclid, JWST, WFIRST, and ELT within Ionized Bubbles in the Intergalactic medium at z > 6

The Square Kilometre Array (SKA) is expected to provide the first tomographic observations of the neutral intergalactic medium at redshifts z > 6 and pinpoint the locations of individual ionized bubbles during early stages of cosmic reionization. In scenarios where star-forming galaxies provide most of the ionizing photons required for cosmic reionization, one expects the first ionized bubbles to be centred on overdensities of such galaxies. Here, we model the properties of galaxy populations within isolated, ionized bubbles that SKA-1 should be able to resolve at z ≈ 7–10, and explore the prospects for galaxy counts within such structures with various upcoming near-infrared telescopes. We find that, for the bubbles that are within reach of SKA-1 tomography, the bubble volume is closely tied to the number of ionizing photons that have escaped from the galaxies within. In the case of galaxy-dominated reionization, galaxies are expected to turn up above the spectroscopic detection threshold of JWST and ELT in even the smallest resolvable bubbles at z ≤ 10. The prospects of detecting galaxies within these structures in purely photometric surveys with Euclid, WFIRST, JWST, or ELT are also discussed. While spectroscopy is preferable towards the end of reionization to provide a robust sample of bubble members, multiband imaging may be a competitive option for bubbles at z ≈ 10, due to the very small number of line-of-sight interlopers expected at these redshifts.

Erik Zackrisson↗