Search NASA⌕ Search

SEARCH · Search NASA

Results for “Wall Model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Numerical Simulation of a Natural Convection–Driven Air-Cooled Reactor Cavity Cooling System Experiment

Ensuring the efficient removal of decay heat from the reactor vessel is essential for the safety of advanced reactor technologies. Several Generation-IV concepts incorporate variations in the reactor vessel cooling systems to achieve this objective. High-temperature gas-cooled reactors utilize a reactor cavity cooling system (RCCS), a passive ex-vessel system designed to operate without active components or external power during accident conditions. The RCCS removes decay heat primarily through radiative and convective heat transfer mechanisms. Here, this study presents a comprehensive validation of a computational fluid dynamics Reynolds-averaged Navier-Stokes model for the University of Wisconsin-Madison air-cooled RCCS facility. Validation was conducted for both high- and low-power natural convection cases under a uniform heating profile. Near-wall resolution was found to be critical for accurately modeling natural convection in the RCCS; employing an all-𝑦 + wall treatment resulted in wall temperature discrepancies exceeding 50 °⁢𝐶 compared to a wall-resolved mesh. Thermal-hydraulic behaviors under natural and forced convection conditions were compared within the heated cavity and RCCS. A turbulence model sensitivity analysis indicated that low-Reynolds number k-ɛ, k-ω shear stress transport (SST), and Reynolds stress transport models produce similar wall temperature predictions. A buoyancy modeling sensitivity study revealed that the Boussinesq approximation significantly underpredicted thermal-hydraulic behavior in the RCCS. Based on these findings, modeling recommendations are provided. The validated data set along with identified sensitivities refine the modeling of natural convection in the RCCS. The information produced by this study supports RCCS design, optimization, and safety evaluations, enabling the calibration and verification of reduced-order thermal-hydraulic models.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Resistive wall tearing mode disruptions

Abstract This paper deals with resistive wall tearing mode (RWTM) disruptions. RWTMs are closely related to resistive wall modes. RWTMs are tearing modes whose linear and nonlinear behavior is strongly dependent on the resistive wall outside the plasma. The consequence for ITER, is that the thermal quench timescale could be much longer than previously conjectured. Active feedback stabilization is another possible way to mitigate or prevent RWTM disruptions. Simulations of RWTM disruptions are reviewed for DIII-D and MST. MST has a longer resistive wall time than ITER, and disruptions are not observed experimentally when MST is operated as a standard tokamak. Simulations indicate that the RWTM disruption time scale is longer than the experimental shot time. Edge cooling causes contraction of the current profile, which can destabilize RWTMs. The equilibria studied here have the q = 2 rational surface close to the edge of the plasma, and low current density between the q = 2 surface and the wall. A sequence of low edge current model equilibria has major disruptions only for a resistive, not ideal, wall, and edge q ⩽ 3.4 . This is consistent with regimes of tokamak disruptivity, suggesting that tokamak disruptions caused by edge cooling at low edge q could be RWTMs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessing the hygrothermal performance of bio-based materials in building wall systems

Building envelope systems are crucial in regulating thermal and moisture exchange between interior and exterior environments, accounting for approximately 28 % of building energy consumption in the United States with walls being the primary contributors. Improper selection of building envelope materials can lead to moisture-related issues, reduced resilience, and compromised durability. Hygrothermal performance assessment is a key factor in efficient building design. As such, improving the energy and hygrothermal performance of opaque wall materials, through careful assessment of material choices, is essential to enhancing building resilience, lowering energy costs, and improving occupant comfort. As the building industry seeks new strategies to reduce material energy intensity, bio-based materials emerge as a promising solution. However, their long-term hygrothermal performance in building envelope systems remains underexplored. To fill this gap, this study evaluates the hygrothermal behavior of 13 bio-based materials in residential wall systems across three U.S. climate zones. Laboratory experiments were performed to measure material properties such as density, thermal conductivity, moisture transmission, and sorption isotherms. These data were integrated into the WUFI® simulation tool to assess wall hygrothermal performance in Houston, Baltimore, and Chicago. A three-phase modeling approach was used: (1) baseline residential walls with oriented strand board (OSB) and gypsum board; (2) replacing OSB with bio-based materials; and (3) replacing drywall with bio-based materials. Results showed that the evaluated bio-based materials maintained acceptable moisture thresholds of ≤ 16 % across all climates, confirming their viability as an alternative for current sheathing materials. Furthermore, this study provides a foundation for future research and innovation in material science on the use of certain bio-based materials in high-performance, low energy use residential construction. Ultimately, providing critical data, offering a database of bio-based material properties, and supplying a simulation-based approach will help designers make informed decisions for future efficient building practices.

Bio-based materials↗

Scalable Federated Learning for Scientific Foundation Models on Leadership-Class Systems

Federated learning (FL) at leadership-class HPC systems remains largely unexplored, despite growing interest in deploying federated workflows on modern HPC systems. This paper provides the first system-level empirical characterization of federated fine-tuning of pretrained foundation models on an exascale supercomputer under a multi-node deployment. Using up to 96 concurrent FL clients deployed across Frontier nodes, we study the impact of client scale, model size, data heterogeneity, partial participation, and differential privacy on runtime, communication overhead, and convergence stability. Our results show that pretrained transformer models remain robust to heterogeneity, client dropout, and privacy noise, while system efficiency degrades rapidly with scale as synchronizat and orchestration dominate runtime. We further demonstrate that system-aware execution strategies, including intra-node aggregation and early aggregation, significantly reduce wall-clock time without degrading model quality. These findings establish a practical performance baseline and inform the design of communication-efficient FL systems on leadership-class HPC platforms.

Kotevska, Olivera [ORNL] (ORCID:0000000316772243)↗

Primary and Low-Strain Creep Models for 9Cr Tempered Martensitic Steels Including the Effects of Irradiation Softening and High-Helium Re-Hardening

Primary and low-strain creep represents a very important integrity challenge to large, complex structures, like fusion reactors. Here, we develop a predictive empirical primary creep model for 9Cr tempered martensitic steels (TMS), relating the applied stress (σ) to strain (ε), time (t) and temperature (T). The most accurate model is based on the applied σ normalized by the steel’s T-dependent ultimate tensile stress (σo), σ/σo(T). The model, fit to 17 heats of 9Cr TMS, yielded a σ root mean square error (RMSE) of ≈±11 MPa. Notably, the model also provides robust predictions for all the other TMS, when calibrated only by the fusion candidate Eurofer97 database. The model was extended to explore two possible effects of neutron irradiation, which produces both displacements per atom (dpa) and helium (He in atomic parts per million, appm) damage. These effects, which have not been previously considered, include: (a) softening, as a function of dpa, at T > ≈400–450 °C, in low-He fission environments (<1 He/dpa); and (b) subsequent re-hardening in high-He (≥10 He/dpa) fusion first-wall environments. The irradiation effect models predict (a) accelerated primary creep due to irradiation softening; and (b) fully arrested creep due to high-He re-hardening.

Alam, Md Ershadul (ORCID:0000000345968026)↗

Toward Verification of RANS Simulations of the T-Tube Modular Divertor Using Large Eddy Simulations of Impinging Turbulent Plane Jets

Turbulent impinging jets have been proposed to cool high heat flux plasma-facing components such as the solid tungsten target plates of the divertor in long-pulse magnetic fusion energy reactors. In particular, the T-tube modular divertor, originally developed by the ARIES Team, consists of two concentric cylindrical tubes where helium flows through a slot in the inner tube, forming an approximately planar jet that impinges upon and cools the inner surface of the pressure boundary (namely, the outer tube) and the ~15-cm 2 plasma-facing W target. The objective of this work is to demonstrate that large eddy simulations (LESs) accurately simulate the thermal transport in canonical flows that comprise the cooling flow in the T-tube, as well as validate temperatures from LES with experimental measurements in a simplified T-tube geometry. Wall‑resolved LESs, validated by experimental data and verified by direct numerical simulations (DNSs), provide benchmark data for two canonical flows in the T‑tube, namely, planar impinging and wall jets, for Reynolds numbers Re B = 4 × 10 3 to 2 × 10 4 . Our LES results are within 4% to 12% root-mean-square error (RMSE) of surface Nusselt number distributions (Nu) from experiments and DNSs. The validated LES results are then used as the ground truth to evaluate four Reynolds‑averaged Navier-Stokes (RANS) turbulence closures, namely, the k‑ω SST, realizable k‑ε, GEKO, and γ‑SST models. The k‑ω SST model has the best overall performance in terms of heat transfer, giving surface Nu within 12% RMSE of the LES results for high‑ReB impinging jets and reduced overprediction in the wall‑jet region. The GEKO model with default constants has the next best performance, providing slightly better Nu predictions for low ReB impinging jets (versus k-ω SST) but worse overall performance over the full range of ReB studied here. The realizable k‑ε turbulence model significantly overestimates turbulence near the stagnation point, while the γ‑SST model suppresses near‑wall production, biasing the simulations toward simulating laminar surface heat transfer. Simulations of the simplified T‑tube show that LES and RANS simulations with the k‑ω SST model give nearly identical average heat transfer coefficients (HTCs) over the impingement surface. The realizable k‑ε model predicts significantly lower wall temperatures due to overestimation of HTC in the outlet flow.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Domain-wall-mediated polarization switching in ferroelectric AlScN: Strain relief and field-dependent dynamics

While scandium-doped aluminum nitride (AlScN) exhibits robust ferroelectricity and excellent thermal stability, its utility is limited by an exceptionally high coercive field (𝐸 𝑐 ) for polarization switching. Unraveling the atomistic switching dynamics is therefore critical for tailoring 𝐸 𝑐 . Here, in this study, we combine density functional theory and machine-learning molecular dynamics to elucidate the polarization switching mechanisms in AlScN over various Sc concentrations and applied electric fields. We find that excessive lattice strain strictly prohibits collective polarization switching, but the preexisting domain walls relieve strain and lead to a distinct switching dynamics—dictating a field-dependent switching mechanism. At low electric fields, switching occurs via gradual domain-wall propagation consistent with the Kolmogorov-Avrami-Ishibashi model. In contrast, high fields stimulate additional nucleation, driving a rapid, homogeneous reversal process described by the simultaneous nonlinear nucleation and growth model. These findings highlight the critical role of domain-wall dynamics and suggest domain engineering as a viable strategy to tailor coercive fields in AlScN and related ferroelectrics.

36 MATERIALS SCIENCE↗

Wall heating by subcritical energetic electrons generated by the runaway electron avalanche source *

Abstract Subcritical energetic electrons (SEEs) produced by the runaway electron (RE) avalanche source at energies below the runaway threshold are found to be the primary contributor to surface heating of plasma-facing components (PFCs) during final loss events. This finding is supported by theoretical analysis, computational modeling with the Kinetic Orbit Runaway electrons Code (KORC), and qualitative agreement with DIII-D experimental observations. The avalanche source generates significantly more secondary electrons below the runaway threshold, which thermalize rapidly when well-confined. However, during a final loss event, the RE beam impacts the first wall, and SEEs are deconfined before they can thermalize. Additionally, because the energy deposition length decreases faster than energy, the deposited energy density, and thus the maximum PFC surface temperature change, is larger for SEEs than REs. KORC simulations employ an analytic first wall to model particle deconfinement onto a non-axisymmetric wall composed of individual tiles. PFC surface heating is calculated using a 1D model extended to include an energy-dependent deposition length scale. Simulations of DIII-D qualitatively agree with infrared (IR) imaging only when SEEs from the avalanche source are included. These results demonstrate that SEEs are the dominant contributor to PFC surface heating and indicate that the avalanche source plays a critical role in the PFC damage caused during final loss events. The prominence of SEEs also has important implications for interpreting IR imaging, one of the primary diagnostics for RE-wall interaction diagnosis, despite REs dominating the energy and current density. This result improves predictions of wall damage due to post-disruption REs to estimate material lifetime and design RE mitigation systems for ITER and future reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Axion domain walls, small instantons, and non-invertible symmetry breaking

Non-invertible global symmetry often predicts degeneracy in axion potentials and carries important information about the global form of the gauge group. When these symmetries are spontaneously broken they can lead to the formation of stable axion domain wall networks which support topological degrees of freedom on their worldvolume. Such non-invertible symmetries can be broken by embedding into appropriate larger UV gauge groups where small instanton contributions lift the vacuum degeneracy, and provide a possible solution to the domain wall problem. We explain these ideas in simple illustrative examples and then apply them to the Standard Model, whose gauge algebra and matter content are consistent with several possible global structures. Each possible global structure leads to different selection rules on the axion couplings, and various UV completions of the Standard Model lead to more specific relations. As a proof of principle, we also present an example of a UV embedding of the Standard Model which can solve the axion domain wall problem. The formation and annihilation of the long-lived axion domain walls can lead to observables, such as gravitational wave signals. Observing such signals, in combination with the axion coupling measurements, can provide valuable insight into the global structure of the Standard Model, as well as its UV completion.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Model Intercomparison Study of Aerosol‐Cloud‐Turbulence Interactions in a Cloud Chamber: 1. Model Results

This study presents the first model intercomparison of aerosol‐cloud‐turbulence interactions in a controlled cloudy Rayleigh‐Bénard Convection chamber environment, utilizing the Pi Chamber at Michigan Technological University. We analyzed simulated cloud chamber‐averaged statistics of microphysics and thermodynamics in a warm‐phase, cloudy environment under steady‐state conditions at varying aerosol injection rates. Simulation results from seven distinct models (DNS, LES, and a 1D turbulence model) were compared. Our findings demonstrate that while all models qualitatively capture observed trends in droplet number concentration, mean radius, and droplet size distributions at both high and low aerosol injection rates, significant quantitative differences were observed. Notably, droplet number concentrations varied by over two orders of magnitude between models for the same injection rates, indicating sensitivities to the model treatments in droplet activation and removal and wall fluxes. Furthermore, inconsistencies in vertical relative humidity profiles and in achieving steady‐state liquid water content suggest the need for further investigation into the mechanisms driving these variations. Despite these discrepancies, the models generally reproduced consistent power‐law relationships between the microphysical variables. This model intercomparison underscores the importance of controlled cloud chamber experiments for validating and improving cloud microphysical parameterizations. Recommendations for future modeling studies are also highlighted, including constraining wall conditions and processes, investigating droplet/aerosol removal (including sidewall losses), and conducting simplified experiments to isolate specific processes contributing to model divergence and reduce model uncertainties.

54 ENVIRONMENTAL SCIENCES↗

Simplified Model and Approach to Transform Infrared Surface Temperature to Film Effectiveness in a Conjugate Heat Transfer Experiment

This paper describes a simplified engineering model based on a one-dimensional thermal resistance network. The model is used to develop a new method to relate film cooling effectiveness and heat transfer augmentation to local overall cooling effectiveness in a conjugate flat plate experiment. This paper presents experimental proof-of-concept data to demonstrate the potential for this model. In contrast to previous approaches, neither the wall heat flux nor the adiabatic wall temperature is required to estimate the local film cooling performance parameters. The model predicts surface temperatures that are within the experimental uncertainties over the range for which the model is trained, and to within five percent when the model is extrapolated to higher coolant channel Reynolds numbers. This paper is relevant to conjugate test rigs that can measure the hot surface temperature distribution with and without film cooling. This information may also be relevant to designers as a method to approximate surface temperatures or used as an approximate heat transfer model for optimization studies.

advanced gas turbines↗

Flow reversal benchmark of a one-sided heated narrow rectangular channel with CATHARE and RELAP5

Flow reversal in narrow coolant channels can be a crucial phenomenon for the safety of research reactors with a downward nominal flow direction. During a loss of forced flow accident, the downward flow stagnates briefly before transitioning into an upward natural circulation flow. The fuel may be damaged if dryout occurs and threshold fuel and/or cladding temperatures are exceeded. A comprehensive study is provided for flow reversal in narrow rectangular channels by examining experimental data and conducting software model analyses. The literature on flow reversal was reviewed, and selected experimental datasets were used to benchmark against CATHARE and RELAP5 models and also compare the code calculations with each other. The experimental data comes from flow reversal tests conducted with a narrow rectangular channel with one-sided heating. The results were compared with experimental data for successful flow reversal tests and predicted dryout power for dryout conditions. Also, the study examined the effects of the pump coastdown period, inlet liquid temperature, system pressure, and localized pressure drops. The experimental results showed that shorter coastdown periods, reduced pressure drops, and lower coolant inlet temperatures increased the dryout power. However, the system pressure did not noticeably affect the results. The simulation results showed that both CATHARE and RELAP5 agreed with experimental data, capturing the trends of the experimental results. Slight differences between each code calculation, as well as the predicted and measured dryout powers, were attributed to experimental uncertainties and the modeling of physical phenomena such as wall nucleation, interfacial heat transfer, drag coefficients, and critical heat flux. Overall, this study provides an understanding of flow reversal and the prediction capabilities of thermal-hydraulics software models. In conclusion, a future study of the flow reversal benchmark of a narrow rectangular channel with two-sided heating may provide additional valuable insights.

CATHARE↗

Elucidating key reducing species beyond ions in hydrogen plasma smelting reduction of iron ore

Hydrogen plasma smelting reduction (HPSR) of iron ore has attracted significant attention over the past decade due to its high-temperature operation, rapid plasma mediated reduction kinetics, and simpler density-based separation of molten iron product, compared to H2-based solid-state reduction. All of these attributes enable processing of low-grade ores for downstream use in electric-arc furnaces, as virgin iron with low gangue content is required for high quality steel and improved furnace operation. While positive ions exist within the plasma arc, this work demonstrates that near the anodic ore surface, hydrogen radicals and vibrationally excited hydrogen species dominate and their densities correlate well with observed reduction rates. Species concentrations in the transferred plasma arc and at the plasma-ore interface are evaluated using coupled thermal plasma and near-wall non-equilibrium plasma models. The thermal plasma model is validated against experimental voltage data and spectroscopic measurements of plasma temperature and density for varying current inputs. Modeling of the near surface thermochemical non-equilibrium and micrometer scale anode sheath layer reveals, in addition to the expected H + , significant concentrations of ArH + and H$^+_3$ ions, typically not observed in thermal plasmas under thermodynamic equilibrium. Our results show that the inverted sheath structure at the anodic ore surface strongly suppresses reactive positive ion fluxes, while non-equilibrium electron-impact processes generate abundant hydrogen radicals and vibrationally excited species. These findings highlight the critical role of non-equilibrium effects in hydrogen arc-driven iron ore reduction and advance understanding beyond prevailing hypotheses centered on hydrogen ion-driven mechanisms.

08 HYDROGEN↗

Integrated modeling of boron powder injection for real-time plasma-facing component conditioning

An integrated modeling framework for investigating the application of solid boron (B) powder injection for real-time surface conditioning of plasma-facing components (PFCs) in tokamak environments is presented. Utilizing the DIII-D impurity powder dropper (IPD) setup, this study simulates B powder injection scenarios ranging from milligrams to tens of milligrams per second, corresponding to boron flux rates of 10 20 –10 21 B/s in standard L-mode conditions. The comprehensive modeling approach combines EMC3-EIRENE for simulating the deuterium plasma background and the Dust Injection Simulator (DIS) for the ablation and transport of the boron powder particles. EMC3 trace impurity fluid modeling results show substantial boron transport to the inboard lower divertor, predominantly influenced by the main ion plasma flow. The dependency on powder particle size (5-250 µm) was found to be insignificant for the scenario considered. The effects of erosion and redeposition were considered to reconcile the discrepancies with experimental observations, which saw substantial deposition on the outer divertor plasma-facing components. For this purpose, the WallDYN3D code was updated to include boron sources within the plasma domain and integrated into the modeling framework. The mixed-material migration modeling shows evolving boron deposition patterns, suggesting the formation of mixed B-C layers or predominantly B coverage depending on the powder mass flow rate. While the modeling outcomes at lower B injection rates tend to align with DIII-D experimental observations, the prediction of near-pure boron layers at higher rates has yet to be experimentally verified in the carbon environment of the DIII-D tokamak. The extensive reach of boron layers found in the modeling suggests the need for modeling that encompasses the entire wall geometry for more accurate experimental correlations. This integrated approach sets a precedent for analyzing and applying real-time in-situ boron coating techniques in advanced tokamak scenarios, potentially extendable to ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Online Tool for Preliminary Design and Techno-Economic Analysis of District Geothermal Heating and Cooling Systems

District geothermal heating and cooling systems (DGHCS) have significant benefits for reducing energy consumption as well as building- and grid-level peak electric demand. Currently, no publicly available tools are available to effectively design and conduct techno-economic analysis of DGHCS. GeoWISE was originally developed for preliminary design and techno-economic analysis of geothermal heating and cooling systems in an individual commercial or residential building. This paper introduces recent upgrades of GeoWISE that allow users to design and conduct techno-economic analysis of DGHCS. Several new features are implemented in GeoWISE to allow selection and specification of multiple new or existing buildings. A database of information for over 125 million existing U.S. buildings was used in GeoWISE that allows users easily locate existing buildings of interest based on street addresses, and optionally edit information of the buildings (e.g., footprint, vintage, principal functions, number of floors, window-to-wall ratio). Unique energy simulation models of the selected buildings are then automatically created using the Automatic Building Energy Modeling (AutoBEM) and EnergyPlus simulations are performed to predict thermal loads of the buildings. A simplified DGHCS is then designed and simulated to predict its energy use. A central borehole heat exchanger (BHE) of the DGHCS is sized using the RowWise algorithm of GHEDesigner to meet the thermal loads within user-specified land areas for installing BHE. The upgraded GeoWISE reports the needed capacity of heating and cooling equipment in each building, design of the central BHE, energy consumption reduction, and energy cost saving resulting from using DGHCS compared with conventional HVAC systems. A case study is showcased using the upgraded GeoWISE to design and conduct techno-economic analysis of a simplified DGHCS.

Prem Anand Jayaprabha, Jyothis Anand [ORNL] (ORCID↗

SANSMIC v.1.0

SAND2024-01036O The updated Sandia Solution Mining Code (SANSMIC) modeling software models the dissolution of underground salt cavern walls due to raw-water injection (leaching), assuming an oil blanket. A previous version of this software modeled the impacts of leaching at the Strategic Petroleum Reserve and has been used in research for several decades, but the source code was not available. The new version will enhance current research as additional subsurface storage of energy in solution-mined caverns increases. It will also allow research reproducibility by making the software available to the wider research community. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Hart, David↗

Simplified Model and Approach to Transform Infrared Surface Temperature to Film Effectiveness in a Conjugate Heat Transfer Experiment

In the pursuit of more efficient gas turbines, film cooling is a critical technology. This article describes a simplified engineering model based on a one-dimensional thermal resistance network. The model is used to relate film-cooling effectiveness and heat transfer augmentation to local overall cooling effectiveness in a conjugate flat plate experiment. Here, this article presents experimental proof-of-concept data to demonstrate the potential for this model. In contrast to previous approaches, neither the wall heat flux nor the adiabatic wall temperature is required to estimate the local film-cooling performance parameters. The model predicts surface temperatures that are within the experimental uncertainties over the range for which the model is trained and to within five percent when the model is extrapolated to higher coolant channel Reynolds numbers. This article is relevant to conjugate test rigs that can measure the hot-surface temperature distribution with and without film cooling. This information may also be relevant to designers as a method to approximate surface temperatures or used as an approximate heat transfer model for optimization studies.

advanced turbines↗

Informative and non-informative decomposition of turbulent flow fields

Not all the information in a turbulent field is relevant for understanding particular regions or variables in the flow. Here, we present a method for decomposing a source field into its informative Φ I (x, t) and residual Φ R (x, t) components relative to another target field. The method is referred to as informative and non-informative decomposition (IND). All the necessary information for physical understanding, reduced-order modelling and control of the target variable is contained in Φ I (x, t), whereas Φ R (x, t) offers no substantial utility in these contexts. The decomposition is formulated as an optimisation problem that seeks to maximise the time-lagged mutual information of the informative component with the target variable while minimising the mutual information with the residual component. The method is applied to extract the informative and residual components of the velocity field in a turbulent channel flow, using the wall shear stress as the target variable. We demonstrate the utility of IND in three scenarios: (i) physical insight into the effect of the velocity fluctuations on the wall shear stress; (ii) prediction of the wall shear stress using velocities far from the wall; and (iii) development of control strategies for drag reduction in a turbulent channel flow using opposition control. In case (i), IND reveals that the informative velocity related to wall shear stress consists of wall-attached high- and low-velocity streaks, collocated with regions of vertical motions and weak spanwise velocity. This informative structure is embedded within a larger-scale streak–roll structure of residual velocity, which bears no information about the wall shear stress. In case (ii), the best-performing model for predicting wall shear stress is a convolutional neural network that uses the informative component of the velocity as input, while the residual velocity component provides no predictive capabilities. Finally, in case (iii), we demonstrate that the informative component of the wall-normal velocity is closely linked to the observability of the target variable and holds the essential information needed to develop successful control strategies.

97 MATHEMATICS AND COMPUTING↗