Search NASA⌕ Search

SEARCH · Search NASA

Results for “Water Electrolysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Evaluating the effect of ionomer chemical composition in silver-ionomer catalyst inks toward the oxygen evolution reaction by half-cell measurements and water electrolysis

The effect of anion exchange ionomer (AEI) chemistry on the kinetics of the oxygen evolution reaction (OER) was systematically studied in both half-cell and single-cell electrolysis experiments. OER was studied in 1 M K 2 CO 3 at 50°C using an array of ionomer-silver catalyst inks deposited on Ni foam. Different ionomer modifications were investigated to optimize the OER performance. The AEI used in this work features a block copolymer backbone of polychloromethylstyrene-b-polycyclooctene-b-polychloromethylstyrene which was functionalized with either benzyltrimethylammonium (TMA) or benzylmethylpiperidinium (MPRD) quaternary ammonium cations. Here, using an MPRD quaternary ammonium cation shifted the rate determining step at high overpotentials, ultimately providing enhanced performance. Increasing the catalyst ink dilution was also found to substantially improve mass activity and catalyst utilization (increase from 35 to 88 A g –1 Ag), likely by reducing the ionomer thickness and decreasing transport resistances. In the final ionomer modification, the Ni foam substrate was leveraged to partially hydrogenate the polycyclooctene midblock to be polyethylene-like at the Ni interface. A significant increase in the electrochemical surface area (Cdl increased from 8.8 to 20.8 mF cm –2 ) and performance (by 47 mA cm –2 or 29 A g –1 Ag) was observed with the incorporation of polyethylene. Kinetic results from half-cell experiments were validated via single-cell anion exchange membrane electrolysis experiments, where the optimized electrode displayed enhanced performance in both 1 M K 2 CO 3 and DI H 2 O.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Parasitic Effects in Impedance Spectrum of PEM Water Electrolysis Cells: Case Study of High-Frequency Inductive Effects

Electrochemical impedance spectroscopy (EIS) is a powerful tool to characterize and distinguish electrochemical, electrical, and diffusive processes in an electrolysis cell. The EIS response with small impedance (mΩ) depends on components and materials of the cell, but often also on the electrical setup, cables, and connectors, leading to incorrect conclusions about the performance of the electrolysis cells. These parasitic effects are assessed via a short-circuit measurement and confirmed to be external from the membrane electrode assembly (MEA). In the setup, the inductive characteristic is described by a modified inductive reactance and must be included in the equivalent circuit model (ECM) which is fitting the cell EIS spectra in operation (in situ). If points of the spectra showing inductive characteristic (below x-axis in Nyquist plot) are excluded from the ECM evaluation, an artificially increased ohmic resistance at high frequencies is obtained. In addition, considerations on other components of the ECM can be misleading and significantly incorrect. The only way to avoid that inductive behavior caused by the external setup is incorrectly assigned to the ECM describing properties of the MEA is to include the inductive effects in the ECM analysis of in situ EIS measurements.

30 DIRECT ENERGY CONVERSION↗

Interfacial engineering via laser ablation for high-performing PEM water electrolysis

A rationalized interfacial design strategy was applied to tailor the porous transport layer (PTL)-catalyst layer (CL) contact and the PTL bulk-phase architecture. Particularly, at the PTL-CL interface, our results reveal that laser ablated sintered titanium power-based PTLs improve electrolyzer performance at both the H2NEW Consortium baseline catalyst loading of 0.4 mgIr cm -2 as well as at the ultra-low catalyst loading of 0.055 mgIr cm -2 . Under ultra-low catalyst loadings, the laser ablated PTL demonstrates maximum reduction of 230 mV compared to the commercial PTL at 4 A cm -2 , and reduces by 68 mV at 3.2 A cm -2 under H2NEW baseline loading. Laser ablation alters the titanium phase at the interface, so it forms more uniform structure like a microporous layer or a backing layer, leading to an increase in the surface area in contact with the catalyst layer while preventing the membrane from deforming into the PTL. Moreover, we reveal that bulk-phase architecture modification of the PTL by ablating patterned pores at the flow field-PTL interface improves mass transport without sacrificing contact at the CL-PTL interface. Overall, laser ablation of the PTL is an effective method to customize interfacial design to enhance proton exchange membrane electrolyzer performance.

08 HYDROGEN↗

Ruthenium-lead oxide for acidic oxygen evolution reaction in proton exchange membrane water electrolysis

Developing an active and stable anode catalyst for the proton exchange membrane water electrolyzer (PEM-WE) is a critical objective to enhance the economic viability of green hydrogen technology. However, the expensive iridium-based electrocatalyst remains the sole practical material with industrial-level stability for the acidic oxygen evolution reaction (OER) at the anode. Ruthenium-based catalysts have been proposed as more cost-effective alternatives with improved activity, though their stability requires enhancement. The current urgent goal is to reduce costs and noble metal loading of the OER catalyst while maintaining robust activity and stability. Here, in this study, we design a Ru-based OER catalyst incorporating Pb as a supporting element. This electrocatalyst exhibits an OER overpotential of 201 mV at 10 mA.cm -2 , simultaneously reducing Ru noble metal loading by similar to 40%. Normalization of the electrochemically active surface area unveils improved intrinsic activity compared to the pristine RuO 2 catalyst. During a practical stability test in a PEM-WE setup, our developed catalyst sustains stable performance over 300 h without notable degradation, underscoring its potential for future applications as a reliable anodic catalyst.

Electrocatalysis↗

Mechanistic and Mitigation-Strategy Insights into NaCl and CaCl 2 Contamination of Proton-Exchange-Membrane Water Electrolysis Using Continuum Modeling

Cationic contaminants are detrimental to proton-exchange-membrane water electrolyzers (PEMWEs). To obtain insight, a 1-D, nonisothermal, multiphase continuum cell model including cationic contamination is developed. Simulations of steady-state cell performance predict decreased performance due to an increase in kinetic overpotential associated with the hydrogen-evolution reaction, which was attributed to decreased protonic-activity within the cathode catalyst layer from proton supplantation with contaminant cations. The accumulation and extent of cation exchange in the cathode catalyst layer depends on the operating current density due to migration. Simulations of cell recovery of potential suggest that a contaminated cell can recover approximately 78% (450 mV) with 24 h of constant current density operation at 2 A cm –2 , with higher current densities accelerating reduced recovery times. Parametric studies show that anode-side acidification at lower current densities inhibit cation contaminant adsorption, and cathode-side acidification at larger current densities facilitate the expulsion of adsorbed cations; for a cathode-side pH of 6 and 5, the cell can recover an additional 10% and 100% performance, respectively. Overall, the model serves as a framework for modeling other aspects of PEMWE systems to address durability and performance aspects, which can assist in improving the viability of the technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Water-Fed, Photovoltaic-Driven Anion-Exchange Membrane Water Electrolysis for Solar Hydrogen Production

Direct coupled photovoltaic (PV)-electrolysis is a promising approach for low-cost hydrogen production, avoiding the need for separate electricity generation. Without solar concentration, the operating current densities of a PV-electrolyzer are small, and low capital costs are needed to reach hydrogen production cost targets (<$2/kg). Anion-exchange membrane (AEM) electrolyzers could be well-suited for this application due to their ability to use platinum group metal (PGM)-free catalysts and operate without supporting electrolytes, but a water-fed PV-AEM system has not yet been demonstrated. In this work, the performance of two AEM electrolyzer designs under pure-water, low-temperature, and diurnal-cycling conditions was evaluated. A simple PV-electrolyzer system design with direct electric coupling to a commercial 84 cm2 Si mini module and passive heating and water flow to the electrolyzer was used for on-sun testing in October 2025. The best-performing PV-AEM system achieved an average solar-to-hydrogen (STH) efficiency of 6.6% and a production rate of 15 mg/kWh/m2 of solar irradiance over 11 days. Minimal electrolyzer corrosion was observed, with no loss in efficiency over the diurnal cycles. While highlighting areas for improved electrolyzer and system design, this work is a proof of concept for distributed hydrogen production using inexpensive and abundant materials.

08 HYDROGEN↗

Hybrid Ionomer-Free Porous Transport Electrodes With Catalyst Coated Membranes for Enhanced Water Electrolysis

To promote industrial uptake of clean hydrogen production technologies such as polymer electrolyte membrane (PEM) water electrolyzers, advancements in catalyst layer (CL) morphology are required. We demonstrate how improved electrochemical performance can be achieved when using an ionomer free porous transport electrode (PTE) coupled with a traditional catalyst coated membrane (CCM) assembly in PEM water electrolyzers. Notably, we reveal that the superior performance achieved when utilizing a hybrid PTE and CCM assembly is due to enhanced ohmic performance caused by optimal contact with both the porous transport layer (PTL) and PEM interfaces. Using operando neutron radiography, we demonstrate that configurations utilizing a CCM resulted in more rapid water replenishment to reaction sites, indicating enhanced membrane hydration beneficial for performance. This enhanced membrane hydration coupled with improved contact area at the PEM-catalyst layer (CL) and PTL-CL interfaces was revealed through the reduced ohmic overpotentials of the hybrid PTE-CCM design, which achieved the lowest ohmic overpotential of 431 mV at 2000 mA cm−2. While the average in-plane water distributions are generally similar between cell configurations, we reveal that utilizing a PTE configuration promotes a more homogenous water distribution near the CL-membrane interface due to enhanced catalyst utilization.

Seip, Tess [ORNL] (ORCID:0000000232740594)↗

Electrochemical phenyl oxidation: A limiting factor of oxygen evolution reaction in water electrolysis

This mini review explains the electrochemical phenyl oxidation of ionomers in the anode catalyst layers of the water electrolyzer that significantly impacts the performance and durability of the device. Although the relevant studies on phenyl oxidation on platinum group metal-free catalysts under high electrode potential are scarce, several studies with platinum group metal catalysts indicated that the impact of electrochemical phenyl oxidation can be profound. In the first part, this review summarizes ionomer-catalyst interactions that impact alkaline electrochemical devices, emphasizing the importance of minimizing interactions between the phenyl moiety of ionomers and oxygen evolution reaction catalysts. In the second part, we discuss the adsorption energies of phenyl groups found in ionomer fragments on different oxygen evolution catalysts. Finally, the mitigation strategies of electrochemical phenyl oxidation for advanced water electrolyzers are briefly discussed at the end of the review.

25 ENERGY STORAGE↗

Tantalum-stabilized ruthenium oxide electrocatalysts for industrial water electrolysis

The iridium oxide (IrO 2 ) catalyst for the oxygen evolution reaction used industrially (in proton exchange membrane water electrolyzers) is scarce and costly. Although ruthenium oxide (RuO 2 ) is a promising alternative, its poor stability has hindered practical application. Here, we used well-defined extended surface models to identify that RuO 2 undergoes structure-dependent corrosion that causes Ru dissolution. Tantalum (Ta) doping effectively stabilized RuO 2 against such corrosion and enhanced the intrinsic activity of RuO 2 . In an industrial demonstration, Ta-RuO 2 electrocatalyst exhibited stability near that of IrO 2 and had a performance decay rate of ~14 microvolts per hour in a 2800-hour test. At current densities of 1 ampere per square centimeter, it had an overpotential 330 millivolts less than that of IrO 2 .

Zhang, Jiahao [Sichuan Univ., Chengdu (China); Uni↗

Complete Phase Transformation of Ir Nanowire Network into Defect-Rich Oxide Catalyst for High-Performance PEM Water Electrolysis

Iridium-based catalysts remain the most reliable option for the oxygen evolution reaction (OER) in proton exchange membrane water electrolyzers (PEMWEs). However, their high cost and limited performance represent critical barriers to the commercialization of this green hydrogen production technology. Herein, we report the creation of a metallic Ir nanowire network (IrNWN), which exhibits superior OER performance through its in-situ transition into an oxide structure with high intrinsic activity. At a low loading of 0.25 mgIr/cm2 in PEMWEs, IrNWN achieved a current density of 3.13 A/cm2 at a cell voltage of 1.8 V, outperforming the commercial Ir-based catalyst and surpassing the Department of Energy (DOE) 2026 technical target. Moreover, the high activity of IrNWN was maintained for 900 hours in a durability test at 2 A/cm2, showing a low degradation rate of 0.042 mV/hour. Structural analysis of the electrochemically oxidized IrNWN revealed the presence of mixed Ir oxidation states and a high density of surface terminal oxygen groups (μ1-O), which contributed to a reduced energy barrier for the rate-determining O-O coupling step.

oxygen evolution reaction↗

High temperature water electrolysis testing of gold-based electrodes for H 2 production

The Hybrid Sulfur (HyS) process is a promising thermochemical water-splitting cycle with global scale hydrogen production potential. The SO 2 -depolarized electrolyzer (SDE) is a critical component of the cycle. At the core of the SDE is the membrane-electrode assembly (MEA), which consists of a polymer electrolyte membrane (PEM) sandwiched between two electrocatalyst layers. New electrocatalyst and membrane materials are being developed with the goals of improving the electrolyzer performance and extending the lifetime of the MEA. In this work, we evaluated the performance of three different membranes and optimized operating conditions, resulting is one of the highest performances in the literature.

08 HYDROGEN↗

NREL's 1MW Water Electrolysis Stack Performance Validation to Pilot-Scale Renewable Natural Gas Production [Slides]

NREL has designed, built, and operates a 1MW water electrolyzer balance-of-plant to support industrial partners and the U.S. Department of Energy in developing next-generation PEM stacks to reduce the cost of hydrogen production. With that hydrogen, we are developing, innovating and de-risking a biomethanation process capable of megawatt-scale deployment that upgrades biogas waste streams to produce pipeline quality renewable natural gas (RNG). Biomethanation is a two-step process using a methanogenic microorganism to convert renewable hydrogen (H 2 ) and waste carbon dioxide (CO 2 ) to renewable methane (CH 4 ) - the primary component in natural gas. Using biogenic CO 2 from biogas sources like dairies, wastewater treatment plants, and landfills allows production of this drop-in direct replacement fuel. Research projects and future R&D topics are also discussed during the presentation.

08 HYDROGEN↗

(Invited) Continuum Mathematical Modeling of Water Electrolysis: A Tutorial

Widespread use of hydrogen energy is contingent on the development of reliable and economical sources of hydrogen. Electrolysis from renewably-derived low-carbon electricity is a potentially viable method of hydrogen generation. Prime among the electrolysis technologies are those utilizing ion-conducting polymers (ionomers) including proton-exchange-membrane water electrolyzer (PEMWE). However, these technologies need to exhibit increased efficiency, performance, and durability to become commercially viable. Like most electrochemical devices, PEMWEs involve multiple components (e.g., catalyst, ionomer, transport layers, membrane, plates) and multiple phases, with phenomena occurring across different time and length scales. Furthermore, it is difficult to experimentally probe many of the species and phenomena during operation. Thus, mathematical modeling at the continuum level has been an invaluable aid in exploring, understanding, and optimizing PEMWE cell and components. Furthermore, this is especially true in the highly coupled and complex physics and chemistries that occur with the membrane-electrode assembly (MEA). The physics in a typical volume-averaged non-isothermal model include multiphase transport in porous media, concentrated-solution theory, Ohm's Law, and Butler-Volmer kinetics, and ion, gas, and water transport in the ionomer.

Dizon, Arthur↗

Resolving Anodic Current and Temperature Distributions in a Polymer Electrolyte Membrane Water Electrolysis Cell Using a Pseudo-Two-Phase Computational Fluid Dynamics Model

Expanding upon our prior experimental work, we constructed a three-dimensional model of a polymer electrolyte membrane water electrolyzer using computational fluid dynamics. We applied the assumption of pseudo-two-phase flow, the flow of two phases with equal velocity. Experimental data were used to obtain parameters and to determine the conditions under which this model was valid. Anodic distributions of current density, temperature, liquid saturation, and relative humidity were obtained at various flow rates. The overall current density and temperature difference from inlet to outlet at the anode agreed strongly with experimental measurements under most circumstances. This verification allowed us to further examine the apparent gas coverage calculated from experimental and model temperature data. Results suggested a low liquid saturation and low relative humidity at the anode due to the consumption of liquid water and water vapor. However, we questioned the accuracy of the pseudo-two-phase assumption at low water feed rates. We concluded that the model was applicable to systems with liquid water feed rates greater than 0.6 ml min -1 cm -2 . Therefore, it is a fair screening method that can advise which operating conditions lead to excessive temperatures or drying at the anode, thereby promoting the longevity of the membrane and catalyst.

25 ENERGY STORAGE↗

Titanium porous-transport layers for PEM water electrolysis prepared by tape casting

While the porous-transport layer (PTL) is a key component in PEM electrolyzers, it is one of the most underexplored due to limited available structures. In this work, we present a novel PTL design for PEM water electrolyzers enabled by a cost-effective, scalable tape-casting technique. Here, a precise control of the PTL pore structure is achieved by incorporating poreformers of various sizes, and by varying the titanium and poreformer ratio. The structures are characterized with SEM and synchrotron X-ray computed tomography imaging techniques. Comprehensive electrochemical performance analysis demonstrates that higher titanium loading provides improved contact at the catalyst-layer/PTL interface but suffers from severe mass-transport losses due to gas bubbles. We solve this mass-transport problem by mixing in large poreformer beads that produce a highly porous structure with excellent gas removal properties yet still maintaining mechanical integrity. The PTL fabricated with 60:40 Ti:PMMA ratio and 60 μm PMMA bead size outperformed the standard commercial Ti powder-based PTL by 62 mV at 4 A/cm 2 .

25 ENERGY STORAGE↗

Proton Exchange Membrane (PEM) Water Electrolysis: Cell-Level Considerations for Gigawatt-Scale Deployment

Hydrogen produced with no greenhouse gas emissions is termed “green hydrogen” and will be essential to reaching decarbonization targets set forth by nearly every country as per the Paris Agreement. Proton exchange membrane water electrolyzers (PEMWEs) are expected to contribute substantially to the green hydrogen market. However, PEMWE market penetration is insignificant, accounting for less than a gigawatt of global capacity. Achieving substantive decarbonization via green hydrogen will require PEMWEs to reach capacities of hundreds of gigawatts by 2030. This paper serves as an overarching roadmap for cell-level improvements necessary for gigawatt-scale PEMWE deployment, with insights from three well-established hydrogen technology companies included. Analyses will be presented for economies of scale, renewable energy prices, government policies, accelerated stress tests, and component-specific improvements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗