Search NASA⌕ Search

SEARCH · Search NASA

Results for “Weathering Rates”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Quantifying the Thermodynamic Impacts on the Atmospheric Boundary Layer due to the Sea Breeze in the Coastal Houston Region

The atmospheric boundary layer (ABL) is unique in coastal regions because of kinematic and thermodynamic influences from continental and marine environments. Sea-breeze (SB) circulations act to equilibrate the land–sea temperature gradient through advecting marine air onshore. The strength of the SB varies in terms of stability, temperature, and moisture advection and influences air quality and weather forecasts. The Tracking Aerosol Convection Interactions Experiment (TRACER) collected a wealth of data on coastal boundary layer evolution, including observations from uncrewed aerial systems (UASs). Vertical profiles of temperature, humidity, and winds were collected by the OU CopterSonde UAS from June to September in the coastal region of Houston. These profiles offer 5-m vertical resolution, on average, every 30 min through diurnal transitions, SB events, and nearby deep convection. During the campaign, CopterSonde observations were gathered through 17 SB events, six of which led to convection initiation. The UAS data can resolve the thermodynamic evolution and interactions between the SB and the preexisting convective boundary layer. Results show large variability across observed SBs and their impacts on temperature and moisture. The intensity of thermodynamic changes depends on the time of sea-breeze passage and influence from the Galveston Bay Breeze, a secondary marine circulation commonly observed in this region. In quantifying the spectrum of SB impacts, equivalent potential temperature θ e is used to contextualize its role in convection initiation and evolution. In conclusion, while all SBs tend to increase θ e from moisture advection, the rate and timing of the θ e rise can distinguish convective from nonconvective cases.

54 ENVIRONMENTAL SCIENCES↗

Outdoor Deployment Data for a Four-Terminal GaAs//Si Tandem Solar Mini-Module

This dataset contains the complete outdoor measurement and analysis data for a mechanically stacked, four-terminal (4T) gallium arsenide (GaAs)//silicon (Si) tandem solar mini-module deployed from October 2019 to January 2021 at the Solar Radiation Research Laboratory (SRRL) in Golden, Colorado, USA. The data support a performance modeling and degradation analysis framework for tandem photovoltaic devices, as described in the accompanying publication. The dataset includes: (1) current–voltage (J–V) characteristics of each sub-cell measured approximately every five minutes, with extracted performance parameters; (2) spectral irradiance from an EKO MS-710 WISER spectroradiometer, along with derived spectral mismatch ratios (SMR) and average photon energy (APE); (3) one-minute resolution meteorological data from the co-located SRRL weather station and GPS-derived precipitable water vapor (PWV); (4) pre-deployment laboratory characterization (external quantum efficiency, J–V curves, standard test conditions parameters); (5) outdoor-extracted temperature and PWV correction coefficients; and (6) PVcircuit equivalent-circuit simulation outputs used for model validation. Degradation rates of −4.1 ± 0.2 %/year (GaAs) and −2.5 ± 0.9 %/year (Si) were determined using a filtering and normalization methodology adapted for fixed-tilt tandem modules. All data are provided in open, portable formats (Apache Parquet, CSV, JSON) to enable full reproducibility of the published analysis.

14 SOLAR ENERGY↗

IM3 + EPRI Data Center Load Projections

This dataset contains scenarios of hourly total electricity demand with and without projected loads from data centers over the period 2022-2040. The root projections without data center demands are identical to those documented in Burleyson et al. 2024. In short, those projections encompass hourly electricity demands for 54 Balancing Authorities (BAs) in the United States across a range of eight of weather and socioeconomic scenarios. Refer to the root dataset and accompanying publication, Burleyson et al. 2025, for information about how those projections were generated. For this derivative dataset we used the base loads from the following scenarios: rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 The root load projections did not reflect the drastic expansion of data centers that has occurred in the last several years to support artificial intelligence and cloud computing. To reflect growth in data center demand, a second set of load projections were created in which we layered in additional data center load projections based on the data center load growth scenarios described in a 2024 report by the Electric Power Research Institute (EPRI): "Powering Intelligence: Analyzing Artificial Intelligence and Data Center Energy Consumption". The EPRI projections from the report are included in this dataset (EPRI_2024_Projections.xlsx). That report contained annual state-level data center load projections for four year-over-year growth rates for data center demands: Low (3.71% annual growth) Moderate (5% annual growth) High (10% annual growth) Higher (15% annual growth) To homogenize the load projections with and without data centers we had to get them to a common scale. The first step was to take the EPRI annual state-level data center energy consumption values and convert them to 8760-hr loads for each year. We did that by assuming a flat (e.g., not weather- or time-sensitive) load profile and distributing the data center loads in each state evenly across all hours in a year. From there the loads were downscaled from the state-level to the county-level using 2019 county-level populations as weights. Finally, the county-level hourly data center loads were summed to the BA-level using the county-to-BA mapping underpinning the root load projections. The net result is 16 (4 weather and socioeconomic scenarios crossed with 4 data center load growth scenarios) unique load projections for the period 2022-2040. The file format follows that of the root dataset with a single additional column "Scaled_TELL_BA_Load_with_DC_MWh" that contains the hourly loads with the added data center loads for a given BA-year-scenario combination. Please refer to the readme file in the root dataset for more information on the file format.

Burleyson, Casey [Pacific Northwest National Labor↗

Modeling the potential effects of rooftop solar on household energy burden in the United States

Policymakers at the federal and state level have begun to incorporate energy burden into equity goals and program evaluations, aiming to reduce energy burden below a high level of 6% for lower income households in the United States. Pairing an empirical household-level dataset spanning United States geographies together with modeled hourly energy demand curves, we show that rooftop solar reduces energy burden across a majority of adopters during our study period from a median of 3.3% to 2.6%. For low- and moderate-income adopters (at or below 80% and 120% of area median income, respectively), solar reduces median 2021 energy burden from 7.7% to 6.2%, and 4.1% to 3.3%, respectively. Importantly, solar reduces the rate of high or severe energy burden from 67% of all low-income households before adoption to 52% of households following adoption, and correspondingly from 21% to 13% for moderate-income households. Here, we show rooftop solar can support policy goals to reduce energy burden along with strategies such as weatherization and bill assistance.

14 SOLAR ENERGY↗

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION↗

Value of Nuclear Energy to the Reliability of the North American Power System: Results for Western and Eastern Interconnections

This report documents the fulfillment of a milestone for the United States (U.S.) Department of Energy Office of Nuclear Energy Light Water Reactor Sustainability Program: completing a baseline study of regional impact of nuclear power plants and hydrogen production in maintaining grid services and power quality. Models have been comprehensively demonstrated for the Western Interconnection, or Western Electric Coordinating Council area, and in the Eastern Interconnection for scenarios representative of past extreme events (e.g., drought and heat waves). Understanding the impact on the reliability of the bulk electric system of any reduction in generation capacity from nuclear power, for any reason, is the motivation of this work. Factors that might lead to the premature or unplanned closure of nuclear plants, extended outages, or repurposing of nuclear power include: • Aging infrastructure: Many nuclear power plants in the U.S. are nearing the end of their designed operating lives. Upgrading aging infrastructure can be expensive, and some utilities may choose to retire plants rather than invest in costly upgrades. • Low wholesale electricity prices: The deregulation of the electricity market in many states has led to increased competition and driven down wholesale electricity prices, causing nuclear power operators to seek other revenue sources for their heat and power such as clean hydrogen production. • Renewables growth: The rapid growth of renewable energy sources like solar and wind power is posing a challenge to traditional generation sources like nuclear. While many see renewables as a key part of the clean energy transition, their intermittent nature requires additional grid solutions for reliable power supply. • The potential for regulatory decisions to be in conflict: In its 2021 rulemaking, EPA rule (86 FR 880), the Environmental Protection Agency (EPA) set a compliance date for the ban on processing and distribution in commerce of Decabromodiphenyl Ether (DecaBDE). Since DecaBDE is in many components, particularly wiring, of nuclear power plants which are deemed safety-related or important to safety, three plants would not have been able to restart after their 2023 spring outages, and numerous others would have faced issues in the near future. Fortunately, in this case, the EPA provided relief to the nuclear energy industry. The report provides a summary of the significant role nuclear energy plays in the United States’ power generation mix, supplying around 20% of the nation’s electricity generation, spread across 28 U.S. states. Nuclear power is reliable, mostly unaffected by weather and seasonal changes, and provides a consistent source of baseload power. In terms of capacity, nuclear power plants account for as much as 26% of balancing area power generation capacity. Nuclear power also provides a substantial contribution (e.g., 10% of the inertia in the Eastern Interconnection) of the synchronous spinning mass/inertia that buffers the rate at which frequency changes when a load and generation imbalance occurs (e.g., a large plant trips or a load is suddenly shed due to a transmission outage). This contribution is critical for maintaining grid stability during sudden changes in load or generation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Complex Dependence of Calcite Crack Kinetics on Salinity: The Role of DLVO and Hydration Forces

Abstract Subcritical crack growth (SCG) plays an important role in many geological processes such as delayed earth rupture and rock weathering. The complex dependency of SCG on the in‐crack fluid chemistry, however, is still poorly understood. In this study, we utilize the newly developed surface force‐based fracture theory (SFFT) to elucidate the relative contributions of surface forces and solute transport to the crack growth kinetics of calcite in NaCl solutions. Expanding on Barenblatt's cohesive crack model, SFFT introduces an effective stress intensity at the crack tip that encompasses all the relevant intermolecular forces across the crack in addition to the external far‐field stresses. The nonlinear system of equations portraying the crack opening profile, the solute distribution in a propagating crack, and the crack growth velocity are numerically solved via an implicit scheme. After carefully calibrating the model for calcite‐water systems, the SFFT is used to predict the SCG response of calcite at different NaCl concentrations, based on various hypotheses. These predictions are then compared to existing SCG data from the literature. We demonstrate that the experimentally observed variation of SCG rate with NaCl concentration cannot be explained solely by DLVO forces (electrostatic and Van der Waals interactions). This can be remediated by introducing an exponentially decaying hydration force with a nonlinear, nonmonotonic dependence on NaCl concentration. Furthermore, we demonstrate that accounting for both diffusive and advective transport of ions is important in explaining the absence of a stage‐II SCG response for calcite in electrolyte solutions. Plain Language Summary Subcritical crack growth (SCG) refers to the slow propagation of cracks in materials under a stress below the threshold for catastrophic failure. SCG is a key process in many geological events, for example, delayed earth ruptures and rock weathering. New initiatives such as underground CO 2 and H 2 storage in carbonate reservoirs further call for better understanding of SCG in carbonate minerals subjected to varying fluid chemistry. This study examines the SCG of calcite, a key mineral found in carbonate rocks, intergranular cement in sandstones, and filling material in mineral veins and faults, determining their deformation and strength. A mathematical model is developed to describe how the crack opens and propagates, how solutes (like salts) distribute within the crack, and how the crack surfaces interact with each other. We used the model to predict calcite SCG in water at different salt concentrations and compared it with experimental data. Our results revealed that the hydration force is the dominating factor in determining the complex, non‐linear dependency of SCG on salinity. We also found that both the movement of ions by diffusion and by bulk water flow are crucial for explaining the SCG rates, especially when the cracks grow quickly. Key Points Surface Force‐Based Fracture Theory predicts the complex subcritical crack growth patterns of calcite crystals immersed in NaCl solutions Results highlight the dominant role of hydration forces in altering the fracture behavior of calcite compared to VdW and electric double‐layer forces Advective solute transport explains the absence of stages‐II and ‐III subcritical crack growth responses in solid‐liquid systems

DLVO↗

Voucher Opportunity 5-15: Independent Assessment of Monitoring, Reporting, and Verification (MRV) Technologies and Practices for Enhanced Rock Weathering (CRADA 718) Abstract

Development of robust, transparent, and precise monitoring, reporting, and verification (MRV) technologies and practices is critical for carbon dioxide removal (CDR) project developers to comply with regulatory and permitting requirements, voluntary carbon market (VCM) protocols, and to ensure safety while reducing environmental impacts. Enhanced rock weathering (ERW)-based CDR technologies focus on removing atmospheric carbon through conversion into thermodynamically stable solid or aqueous carbonate forms for permanent storage (i.e., mineralization). This highly durable form of CDR enhances naturally occurring silicate rock weathering cycles by optimizing application of finely-ground silicate rock particles (i.e., from basalt) on terrestrial agricultural lands to accelerate natural silicate rock weathering and mineralization. Enhanced rock weathering may also provide improved crop yields and enhance soil health. A critical aspect for commercialization of these technologies is the development of MRV to quantify the net removal and durable storage of atmospheric CO 2 . For ERW systems, it is essential to accurately characterize the mineral feedstock selected for application to establish the baseline geochemical composition, mineral dissolution rates, and carbon removal potential of the feedstocks to estimate overall net removal. Given the difficulty with conducting MRV for ERW in diverse soil/environment types, over large application areas, and due to complex chemical reaction networks, this project will accelerate understanding towards consensus on best practices for MRV. The overall objectives of the proposed voucher project are to: 1) Characterize and analyze feedstock(s) intended for ERW field application by Lithos Carbon (“Voucher Recipient”/ “CRADA Participant”) to determine overall mineralization potential; 2) Facilitate knowledge transfer and documentation of experimental protocols, instrumentation, and other relevant best practices; and 3) Support the Voucher Recipient’s broader technology commercialization and ERW Research Facility development plans. This work will align with the Voucher Recipient’s MRV plans for field sites and build upon complementary efforts conducted by PNNL on mineralization MRV.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid SACR Observations of Convection at Bankhead National Forest (RAPID) Field Campaign Report

Improving our representation of convective cell processes requires better quantification of convective clouds throughout their entire life cycle. This includes gaining a clearer understanding of the controls on key convective cloud properties, such as updraft intensity, particle size distributions, rainfall rates, and hydrometeor species. Our inability to improve convective cloud process modeling stems, in part, from a limited understanding of convective cell properties, particularly given how rapidly these storms evolve. This lack of detailed observations in the most intense and organized convective storms is especially significant, as large errors remain in representing these clouds, which are critical for severe weather prediction and Earth system model performance. Cloud and precipitation radars are essential tools for studying cloud microphysics and dynamics, particularly in deeper convective clouds. The recent U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility’s third Mobile Facility (AMF3) Bankhead National Forest (BNF) deployment provides a unique opportunity to investigate important land–atmosphere interactions, as well as the environmental controls on deep convective cloud processes, in a location favorable for frequent convection. We operate the X/Ka-band Scanning ARM Cloud Radar (X/Ka SACR) using a scan strategy optimized to capture these rapidly evolving clouds and their properties, thereby improving studies of deep convective cloud processes. This effort is strengthened by a complementary and coordinated partnership with ongoing university and multi-agency radar activities collocated in north Alabama—a unique opportunity to examine clouds and precipitation from a lifetime-centric perspective.

54 ENVIRONMENTAL SCIENCES↗

Proof-of-concept chemometric approach for environmental forensic sourcing of crude oil samples using SPME-GC-MS

Environmental exposure to crude oil through seepage and spillage poses risks to the immediate environment and the broader ecosystem as areas along the oil distribution path are affected by the influx of crude petroleum as well as the environmental, economic, and civil unrest that accompanies it. There is a large financial burden associated with the lost resources, including the cost of rehabilitation, and the affected sources of revenue for communities affected by oil spills. As such, it is crucial to determine the responsible parties. This work outlines an environmental forensics approach to determining the source of an un-weathered crude oil sample. The researchers employed solid phase microextraction coupled with gas chromatography mass spectrometry (SPME-GC-MS) to capture and analyze the gaseous components emitted by crude oil samples sourced from five locations. Samples were analyzed using Spearman's rank correlation and 3D covariance analysis. Both chemometric approaches yielded optimal performance results with no misclassifications, true positive rate (TPR) = 100 % and false positive rate (FPR) = 0 %. The similarity metrics calculated by each test noted clear delineations between the values of same-source and differently sourced samples. The Spearman's rank correlation test and 3D covariance calculations both demonstrated the ability to correctly identify sample source origin in this dataset. Finally, the authors outline an approach to the future application of these tests and suggest their joint use in future crude oil sourcing endeavors.

3D covariance mapping↗

Anthropogenic extremely low volatility organics (ELVOCs) Govern the Growth of Molecular Clusters over the Southern Great Plains during the Springtime

New particle formation (NPF) and growth govern cloud condensation nuclei (CCN) concentrations in many regions. The mechanisms governing the nucleation of molecular clusters vary substantially in different regions of the atmosphere. Additionally, the growth of these clusters from ~2 to 20 nm sizes is often governed by the availability of extremely low volatility organic vapours (ELVOCs). While the pathways to ELVOC formation from the oxidation of biogenic monoterpenes with ozone is better understood, the chemical and mechanistic pathways for ELVOC formation from oxidation of anthropogenic organics are not well understood. We integrate measurements and three-dimensional regional model simulations with the Weather Research and Forecasting Model coupled to chemistry (WRF-Chem) to understand the processes governing new particle formation and growth and secondary organic aerosol (SOA) formation during the Holistic Interactions of Shallow Clouds, Aerosols and Land Ecosystems (HI-SCALE) field campaign at the Southern Great Plains (SGP) observatory in Oklahoma, and contrast it with a site within the Bankhead National Forest (BNF), Alabama in Southeast USA, where 5-year long measurements will begin in 2024. Simulations show that nucleation rates are at least an order of magnitude higher at SGP compared to BNF during the springtime days (April 28 and May 14, 2016), largely due to lower H2SO4 concentrations at BNF, which are needed for nucleation. In addition, the larger CS at BNF (compared to SGP) increase the loss of molecular clusters by coagulation to pre-existing particles. Among the 8 different nucleation mechanisms in WRF-Chem, we find that the amine+H2SO4 nucleation mechanism dominates at the SGP site, while the pure organic ion induced nucleation mechanism dominates over BNF. Through various WRF-Chem sensitivity simulations, we find that anthropogenic ELVOCs are critical for explaining the growth of newly formed particles and the resulting number size distribution observed near the surface at the SGP site during the daytime. In addition, we show that treating organic particles as semisolid, with strong diffusion-limited uptake of organic vapours, brings model predictions into closer agreement with the observed evolution of particle size distribution. Simulations also predict that anthropogenic SOA, formed by the oxidation of aromatic volatile organic compounds (VOCs), is the dominant organic aerosol component at SGP, while biogenic SOA dominates particle composition at the BNF site in Southeast USA on these days.

Shrivastava, ManishKumar B.↗

Improving Dynamic Wireless Charging System Performance For Electric Vehicles Through Variable Speed Limit Control Integration

Electric Vehicle (EV) charging has been a significant barrier to the widespread use of EVs. Traditional EV charging methods depend on cables, and there are concerns about safety, accessibility, convenience, and weather. A recent development, dynamic (or in-motion) wireless charging, enables EVs to charge wirelessly by incorporating charging infrastructure into roadways, allowing EVs to charge while moving. However, the energy transferred relies heavily on vehicle speed and time spent in the charging lane. This paper proposes an innovative solution that combines dynamic wire-less charging with Variable Speed Limit (VSL) control. This dynamic traffic control strategy adjusts speed limits based on real-time traffic, weather, and incidents. This integration of dynamic wireless charging and VSL has two potential benefits. First, it can motivate driver compliance with VSL through the incentive of charging. Second, it can promote smoother traffic flow and improve traffic safety by implementing lower speed limits at certain times. To verify these benefits, microscopic traffic simulations in SUMO were conducted under different EV penetration rates and VSL compliance rates. Simulation results reveal that the proposed approach can enhance dynamic wireless charging system performance while improving traffic flow and safety.

Xu, Guanhao [ORNL] (ORCID:0000000214326357)↗

Influence of background sources and topographic resolution in the Weather Research and Forecasting Model on xenon plume characteristics at monitoring stations

For many atmospheric monitoring applications, networks of measurement sites—such as the radionuclide stations of the International Monitoring System—can be sparse. With measurement locations potentially hundreds to thousands of kilometers from a release it is important to quantify the effects of physical processes on transport and dispersion of plumes between source and measurement locations. This study addresses the effects of background sources and topography resolution near the release location of radionuclides. We use the Weather Research and Forecasting (WRF) model with inline chemistry to investigate (1) how an additional, time-varying source of 133 Xe, such as an operational medical isotope production facility, contributes to activity concentration measurements at monitoring sites, and (2) how complex topography influences on atmospheric conditions near emission sources impact plume concentrations at varying distances from the source. Two 133 Xe emission sources, including (1) a high flux rate of short duration representing an explosive event, and (2) a variable and continuous background source, are simulated. The continuous background source contributes significantly to total 133 Xe concentrations at several monitoring stations. Further, a WRF simulation at 9 km horizontal resolution is compared with a nested grid simulation, where the innermost domain has a resolution of 1 km. Increased topographic resolution leads to an improved representation of plume responses to local winds, with topographic influences greatest at locations closest to the sources. Differences between the two domain resolutions decrease at greater distances from the sources, as plumes have time to spread and mix and are influenced by synoptic scale circulation patterns that are represented similarly in both simulations.

54 ENVIRONMENTAL SCIENCES↗

Direct air capture with amino acid solvent: Operational optimization using a crossflow air‐liquid contactor

Direct air capture (DAC) is a negative emission technology for removing CO2 from the atmosphere to maintain the CO 2 level within a reasonable range so as to address greenhouse effects. In this study, the operational optimization of lab-scale DAC has been investigated using a crossflow air-liquid contactor loaded with a three dimensionally printed Gyroid packing structure and a potassium sarcosinate solvent. The effects of various parameters, including feed air flow rate, liquid solvent flow rate, contactor geometry, and ambient temperature, are examined. The results demonstrate that the Gyroid packing design achieves comparable CO 2 capture performance to conventional packed beds but with a significantly lower pressure drop of up to 77.8%, suggesting its potential as an efficient and cost-effective solution for gas–liquid contactors in DAC. Additionally, the study explores the climate impact on CO 2 capture performance and finds that as the air temperature increases from 35 to 95°F at a fixed relative humidity of 80%, the CO 2 capture rate increased from 23.2% to 46.8% with better stability. The research highlights the importance of optimizing contactor design and operational conditions to improve the CO 2 capture rate and feasibility of DAC systems as a negative emission technology for addressing greenhouse effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ocean internal tides suppress tropical cyclones in the South China Sea

Abstract Tropical Cyclones (TCs) are devastating natural disasters. Analyzing four decades of global TC data, here we find that among all global TC-active basins, the South China Sea (SCS) stands out as particularly difficult ocean for TCs to intensify, despite favorable atmosphere and ocean conditions. Over the SCS, TC intensification rate and its probability for a rapid intensification (intensification by ≥ 15.4 m s −1 day −1 ) are only 1/2 and 1/3, respectively, of those for the rest of the world ocean. Originating from complex interplays between astronomic tides and the SCS topography, gigantic ocean internal tides interact with TC-generated oceanic near-inertial waves and induce a strong ocean cooling effect, suppressing the TC intensification. Inclusion of this interaction between internal tides and TC in operational weather prediction systems is expected to improve forecast of TC intensity in the SCS and in other regions where strong internal tides are present.

54 ENVIRONMENTAL SCIENCES↗

Quantum-Inspired Bayesian Sampling for Uncertainty Quantification and Machine Learning (Final Technical Report)

With increasing simulation and measurement data, machine learning and artificial intelligence have been widely used in computational decision-making of complex engineering systems. The resulting tools, such as uncertainty quantification solvers, reinforcement learning, and physics-informed machine learning, have achieved great success in critical DOE tasks such as material discovery and design, energy system modeling and control, and numerical weather and climate prediction. A core topic in scientific machine learning and artificial intelligence is Bayesian inference: given an observed data set, people want to estimate the posterior distribution of a (possibly large) number of hidden parameters. Due to the flexibility and weak assumptions, Bayesian sampling has been the mainstream Bayesian inference solvers despite the rapid progress of approximate Bayesian inference. Classical Bayesian sampling methods such as Markov-chain Monte Carlo suffer from a low-acceptance rate due to the random walk nature, therefore state-of-the-art techniques use Hamiltonian Monte Carlo and its variants to efficiently draw posterior samples in a high dimension. The key idea of Hamiltonian Monte Carlo and its variants is to simulate the Hamiltonian dynamics of a classical particle with a fixed mass, and their performance significantly degrades when the posterior distribution is highly spiky or has multiple modes. Leveraging the idea of quantum physics, this project has investigated new theory, algorithms and applications of Bayesian inference (especially Bayesian sampling). The main results include: (1) novel quantum-inspired Bayesian sampling methods that can lead to better accuracy for challenging multi-modal or spiky distributions, (2) more scalable machine learning framework leveraging tensor-compressed Bayesian inference, and (3) Bayesian and sampling approaches for verifying the robustness of continuous and binary neural networks.

97 MATHEMATICS AND COMPUTING↗

Automated Operational Forecasting of Monsoon Low Pressure Systems

Monsoon low pressure systems (LPSs) are the dominant rain-bearing weather system of South Asia, often producing extreme precipitation and hydrological disasters in a region inhabited by nearly two billion people. Despite the importance of these storms, no operational system has automatically identified and tracked LPS in real time in numerical weather prediction model output; many commonly used vortex-tracking algorithms are ill suited for monsoon LPS because of the weak winds and cold cores of these systems. Here, we describe a new system that uses optimized algorithms to identify monsoon LPS in short- to medium-range forecasts from the U.S. Global Ensemble Forecast System (GEFS) and a version of the deterministic Global Forecast System (GFS) adapted and used operationally by the Indian Institute of Tropical Meteorology (IITM). We also assess the historical performance of these models in forecasting South Asian monsoon LPS, comparing this with the performance of the Integrated Forecasting System of the ECMWF. We assess the accuracy of model predictions of LPS genesis, position, intensity, and precipitation rates for forecast lead times of 1–5 days, yielding quantitative information on model biases to guide operational forecasters and disaster managers. The system we introduce here could be extended to other low-latitude regions affected by dynamically weak, heavily precipitating atmospheric vortices that are often not included in tropical cyclone inventories.

54 ENVIRONMENTAL SCIENCES↗

Supporting ARPA-E Power Grid Optimization (Final Report)

Pacific Northwest National Laboratory (PNNL), Arizona State University (ASU), Georgia Institute of Technology (Georgia Tech), Los Alamos National Laboratory (LANL), National Renewable Energy Laboratory (NREL), Texas A&M University (TAMU), The University of Texas at Austin (UT), and the University of Wisconsin-Madison (UW-M) supported the ARPA-E Grid Optimization (GO) Competition by providing a common problem formulation, data format, datasets, evaluation mechanism, scoring, rules, and results that resulted in the awarding of $\$9.24$ million dollars to teams from academia, industry, and national labs for solving three sets of increasingly difficult non-linear, security- constrained AC Optimal Powerflow (AC-OPF) optimization problems in order to increase the efficiency of the US Electric Grid. It is estimated that a 1% increase in efficiency can save $\$1$ billion. Current industry practices typically use a linear DC model (DC-OPF) in order solve the OPF problem within the time constraints of the operation schedule. The GO Competition challenges the best power engineers, mathematicians, and computer scientists to make possible operational decisions based on accurate physical models. To accomplish this, the GO Competition created a series of Challenges and funded teams to produce the best solver. Challenge 1 was to solve the security constrained Alternating Current Optimal Power Flow (ACOPF) problem. Challenge 2 extended that to by adding adjustable transformer tap ratios, phase shifting transformers, switchable shunts, price-responsive demand, ramp rate constrained generators and loads, and fast-start unit commitment (UC). Furthermore, Challenge 2 was a maximization problem while Challenge 1 was a minimization problem. While Challenge 3 was being developed, the entrants were invited to find better solutions to the Challenge 2 synthetic datasets with no restrictions on time, hardware, or algorithms. The Challenge 2 solutions turned out to be very good. Challenge 3 expanded the Challenge 2 problem further by using multiperiod dynamic markets, including advisory models for extreme weather events, day-ahead markets, and the real-time markets with an extended look-ahead. These problems included active bid-in demand and topology optimization. Together the Challenges used nearly 30 million CPU hours. Since each team was working on the same problem, using the same data, and running on the same hardware, fair comparisons could be drawn as to the best solver. The datasets were varied enough, however, that the best solver for one dataset was not necessarily the best at another, so cumulative scores were used. The process was managed by the PNNL maintained website https://GOCompetition.energy.gov, where Entrants could find information about the problem, the data, the rules, submit their solver for evaluation, and see the scores of all the competing teams on a Leaderboard. Interest was world-wide but only American teams were eligible for prizes. The Competition has produced 34 journal articles 115 papers and been cited over 500 times in the literature, including 12 dissertations (4 from foreign countries; Columbia (2), Germany, and Italy) and 3 from the DOE ExaScale project. Software developed by Pearl Street Technologies for Challenges 1 and 2 is now deployed by Southwest Power Pool (SPP) and Midcontinent Independent Service Operator (MISO). Other teams have received inquiries from venture capitalists. Google DeepMind has thanked the Competition for making the datasets developed for the Competition public. They are using it to train machine learning models. The larger datasets have billions of unknowns to be solved for, but only a small percent matter in the final solution. Knowing what unknowns are important can dramatically speedup the solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗