Search NASA⌕ Search

SEARCH · Search NASA

Results for “Well Installation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

TEACHING AN OLD ACCELERATOR NEW TRICKS

The Argonne Tandem Linac Accelerator System (ATLAS) has been a National User Facility since 1985. In that time, many of the systems that help operators retrieve, modify, and store beamline parameters have not kept pace with the advancement of technology. Development of a new method of storing and retrieving beamline parameters resulted in the testing and installation of a time-series database as a potential replacement for the traditional relational database. InfluxDB was selected due to its self-hosted Open-Source version availability as well as the simplicity of installation and setup. A program was written to periodically gather all accelerator parameters in the control system and store them in the time-series database. This resulted in over 13,000 distinct data points, captured at 5-minute intervals. A second test captured 35 channels on a 1-minute cadence. Graphing of the captured data is being done on Grafana, an Open-Source version is available that co-exists well with InfluxDB as the back-end. Grafana made visualizing the data simple and flexible. The testing has allowed for the use of modern graphing tools to generate new insights into operating the accelerator, as well as opened the door to building large data sets suitable for Artificial Intelligence and Machine Learning applications.

Novak, D.↗

Performance of Windows in Walls With Continuous Insulation

Window openings in walls are a significant contributor to poor thermal performance because of thermal bridging through the framing members (e.g., studs, joists, plates, bracing) and because windows lack the thermal properties of insulation. Window installation guidance for walls with continuous insulation (CI) is critical for continued market growth of this energy efficiency technology. This research project offers window manufacturers a starting point and a potential path toward developing installation instructions for windows over CI. The objectives of the research include evaluating the common method for installing windows in walls with CI, as well as establishing acceptance criteria for evaluating the performance of windows installed in walls with and without CI. The research measures: 1. The performance characteristics (e.g., water management, structural integrity) of windows in walls without CI. 2. The performance of different thicknesses and types of CI used in walls. 3. The performance of different types of window assemblies (e.g., double-hung windows, mulled double-hung windows, mulled casement windows, and slider windows) installed over CI. 4. The performance of window flange types (e.g., rigid mounting and less robust flanges) installed over CI. 5. Installing windows over CI using baseline installation instructions versus window manufacturer installation instructions. The project’s sequential testing protocol consists of the following: • A water penetration resistance testing adapted from two ASTM standards: E331 (uniform static air pressure in four steps) and E547 (cyclic static air pressure) • A temperature cycling adapted from ASTM E2264 Method B (convective hot air) • A service condition wind loading test adapted from ASTM E330 • A six-month vertical displacement observation phase prior to the structural performance testing • A final water penetration resistance test after vertical displacement observation • A structural performance test adapted from ASTM E330. Key research findings include: • The criterion for passing a water penetration resistance test is that there is no water overflowing at the interior face of the studs. If there is any bubbling or slight pooling of water at the sill, then it must recede after the pressure is removed. Excessive leakage and/or water leaking to the interior face of the framing around the window constitutes a failure. • All single double-hung windows installed directly to lumber or over oriented strand board passed all test protocols. • For most wall specimens, the test results showed that the use of foam sheathing did not affect the performance of the window for water leakage. • All wall specimens underwent temperature cycling. The results indicated that temperature cycling had little to no effect on windows installed over foam sheathing. • For wall specimens that underwent six-month vertical displacement monitoring, the results showed that windows installed over foam sheathing do not sag over time. • The single-hung and double-hung windows installed using window manufacturer installation instructions passed the structural performance test, compared to failures observed in windows that were installed using generic installation instructions. The generic and manufacturer installation methods differed on the following construction details: type of fasteners, fastening patterns on the flanges, and window shimming details. • Additional testing is required to determine methods to improve structural pressure performance of slider windows. Potential solutions that would require additional testing may include fastener spacing, different types of fasteners, masonry window clips, construction adhesive, foam sealant, stronger window flange material, and/or straps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Utah FORGE: 16B(78)-32 RFS DSS Strain Change Rate vs. Depth During 16A(78)-32 Stimulation

This dataset contains strain change rate versus depth data acquired using a Rayleigh frequency shift (RFS) distributed strain sensing (DSS) system during hydraulic stimulation of well 16A(78)-32 at the Utah FORGE site in April 2024. The data were collected from an optical fiber installed in the annulus of production well 16B(78)-32, approximately 300 feet from the injection well. The dataset includes tabulated strain data and an explanation of the methodology used to generate the frac log, which integrates strain change rate signals over selected time windows to identify fracture events.

15 GEOTHERMAL ENERGY↗

Detecting fractures and monitoring hydraulic fracturing processes at the first EGS Collab testbed using borehole DAS ambient noise

Enhanced geothermal systems (EGS) require cost-effective monitoring of fracture networks. We validate the capability of using borehole distributed acoustic sensing (DAS) ambient noise for fracture monitoring using core photos and core logs. The EGS Collab project has conducted 10 m scale field experiments of hydraulic fracture stimulation using 50–60 m deep experimental wells at the Sanford Underground Research Facility (SURF) in Lead, South Dakota. The first EGS Collab testbed is located at 1616.67 m (4850 ft) depth at SURF and consists of one injection well, one production well, and six monitoring wells. All wells are drilled subhorizontally from an access tunnel called a drift. The project uses a single continuous fiber-optic cable installed sequentially in the six monitoring wells to record DAS data for monitoring hydraulic fracturing during stimulation. We analyze 60 s time records of the borehole DAS ambient noise data and compute the noise root-mean-square (rms) amplitude on each channel (points along the fiber cable) to obtain DAS ambient noise rms amplitude depth profiles along the monitoring wellbore. Our noise rms amplitude profiles indicate amplitude peaks at distinct depths. We compare the DAS noise rms amplitude profiles with borehole core photos and core logs and find that the DAS noise rms amplitude peaks correspond to the locations of fractures or lithologic changes indicated in the core photos or core logs. We then compute the hourly DAS noise rms amplitude profiles in two monitoring wells during three stimulation cycles in 72 h and find that the DAS noise rms amplitude profiles vary with time, indicating the fracture opening/growth or closing during the hydraulic stimulation. Our results demonstrate that borehole DAS passive ambient noise can be used to detect fractures and monitor fracturing processes in EGS reservoirs.

58 GEOSCIENCES↗

Federal Workplace Charging Program Guide

This report serves as a program guide to support federal agencies in developing their own policy documents for workplace charging. It provides suggested language that agencies can incorporate into their own policies to define requirements for charging privately owned vehicles (POVs) on government-owned or leased property. The Fixing America's Surface Transportation Act authorizes the U.S. General Services Administration (GSA) and other federal agencies to install, operate, and maintain electric vehicle supply equipment (EVSE) for POVs in parking areas used by federal employees and authorized users, and it requires the collection of fees to recover the costs of installing, operating, and maintaining this equipment. This guide offers details for agency facility managers, transportation personnel, employees, and vendors regarding the charging of electric vehicles (EVs) for use by employees and personnel at government-owned and leased buildings. This guide describes the requirements associated with federal agencies providing EV charging in publicly accessible sites. The policy also describes when and how fees may be imposed to cover costs of electricity, as well as EVSE units and installations in various scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Mechanistic modeling of CO 2 well leakage in a generic abandoned well through a bridge plug cement-casing gap

Both known and unmapped plugged and abandoned wells are potential leakage pathways for CO 2 from geologic carbon sequestration (GCS) sites. Although many abandoned wells have cement bridge plugs installed to prevent leakage, the seal between the cement and the inner casing wall is subject to failure. In this study, we carried out detailed T2Well simulations of cases of sudden non-Darcy flow of CO 2 and brine leakage up the gap between a cement plug and the inner steel casing wall that becomes a fully connected flow path during the post-injection period. The goal of our study was two-fold: (1) to understand the dynamics, rates, and the characteristic temporal signals associated with the onset of leakage through various gap-aperture sizes, and (2) to suggest potential monitoring strategies based on the findings. Simulation results show that the leakage of CO 2 and brine upward is transient with interesting phase interference behavior. Time-dependent oscillatory flows with varying pressure, temperature, and flow rates of CO 2 and brine show strong dependence on gap aperture. Phase-change and decompression lead to very low temperatures at the top of the well for gap apertures larger than 4 mm suggesting that remote thermal monitoring at the ground surface may be an effective way of monitoring even if well locations are not known a priori. Pressure in the well is also indicative of CO 2 leakage. The temporal patterns of changing temperature and pressure may be useful diagnostic signals for leakage detection. Finally, these transient leakage signals may provide information on the cause of leakage and/or characteristics of the flow path that could inform effective remediation design and execution approaches.

58 GEOSCIENCES↗

Historic and modern approaches for discovery of abandoned wells for methane emissions mitigation in Oil Creek State Park, Pennsylvania

Hundreds of oil wells were drilled along Oil Creek in Pennsylvania in the mid-16 1800s, birthing the modern oil industry. No longer in operation, many wells are now classified as abandoned, and, due to their age, their locations are either unknown or inaccurately recorded. These historic well sites present environmental, safety, and economic concerns in the form of possible methane leaks and physical hazards. Airborne magnetic and LiDAR surveys were conducted in the Pioneer Run watershed in Oil Creek State Park to find abandoned wells in a historically significant but physically challenging location. Wells were drilled in this area prior to modern geolocation and legal documentation. Although a large number of old wells were abandoned summarily without remediation of the site, much of the land area within Oil Creek State Park is now covered in trees and dense underbrush, which can obscure wellheads. The thick vegetation and steep terrain limited the possibility of ground-based surveys to easily find well sites for methane emissions studies. The data from remote sensing surveys were used to corroborate potential well locations from historic maps and photographs. Potential well sites were verified in a ground-based field survey and monitored for methane emissions. Two historic photographs documenting oil activity in the late 1800s were georeferenced using a combination of magnetic and LiDAR data. LiDAR data, which were more useful in georeferencing and in field verification, identified 290 field locations in the Pioneer Run watershed, 86% of which were possible well sites. Sixty-two percent of the ground-verified wells remained unplugged and comprised the majority of leaking wells. The mean methane emissions factor for unplugged wells was 0.027 ± 0.099 kg/day, lower than other Appalachian Basin methane emissions estimates. LiDAR was used for the first time, in combination with an airborne magnetic survey, to reveal underground oil industry features and inform well identification and remediation efforts in difficult-to-navigate regions. In the oldest oil fields, where well casing has been removed or wood conductor casing was installed, historic photographs provide additional lines of evidence for oil wells where ground disturbances have concealed surface features. Identification of well sites is necessary for mitigation efforts, as unplugged wells emit methane, a potent greenhouse gas.

02 PETROLEUM↗

Standardized nomenclature for photovoltaic connectors

Photovoltaic (PV) systems rely on discrete connectors for the efficient and safe flow of power from module to module and from strings to combiner boxes and inverters. Despite their functional importance, no common nomenclature for PV connectors currently exists, resulting in confusion and miscommunication. Misunderstood terms like "MC4 compatible", "cross-mating", "intermating", "female", and "male" can lead to installation and maintenance errors and compromise system reliability. We believe a standardized terminology will reduce confusion, help support installation best practices, aid in maintenance and repair, inform next-generation designs, and provide a technical basis for improved codes and standards. To that end, we are proposing a standardized glossary for 4 mm PV connectors (the most common type of connector used in PV applications) based on, and validated by, a Sandia National Laboratories' investigation that included the following sources: 1) a comprehensive review of official documents from 20 connector manufacturers, including schematics, datasheets, installation manuals, and catalogs, as well as relevant patents; 2) two rounds of surveys distributed to stakeholders, including connector manufacturers, engineers, asset owners, test labs, and researchers; and 3) visual examination of 25 different models of 4 mm single-pole DC PV connectors to document variations in design and functionality. This work provides a foundation for establishing a clear and consistent terminology for PV connectors that will in turn enable progress toward greater reliability and collaboration across the industry.

14 SOLAR ENERGY↗

Final Booster Complex Design for the Jefferson Lab Electron Ion Collider*

In this work we show the final iteration of the design for the booster complex of the Jefferson Lab EIC, which would have brought the ions from an energy (proton) of 150 MeV up to 12.1 GeV. This complex would have consisted of two figure-8 rings. The Low Energy Booster (LEB) which would have accelerated its protons from 150 MeV to 8 GeV, and has had its lattice tweaked to increase the effectiveness of chromaticity cancellations. The High Energy Booster (HEB) would have brought the 8 GeV protons up to 12.1 GeV. The HEB would in the tunnel that was designed for the collider rings, sitting on top of them. It has had a bypass around the interaction region added, as well as a cooling solenoid installed.

Nissen, E. A.↗

The Contact Stress Sensor _ Proposal to the FY2020 Technology Tech Mat Grants Program

The technology to be advanced is a very small and thin Contact Stress Sensor (CSS) that measures the contact stress between two contacting surfaces. It will be used to monitor the internal condition of a weapon in the stockpile over periods of decades. Monitoring the load path of a complex weapon assembly offers an important verification of the weapon’s mechanical state in both quasi-static or dynamic environments. Concurrently, the sensor can be used to measure temperature. This is useful for sensor calibration while installed in a system, as well as thermal monitoring in regions of the system that are difficult to access. Thus, the CSS is one way to monitor the internal “health” of a weapon. A sensor is shown below with each sensor being less then 2mm in width and 125 microns in thickness.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Western Sector In-Situ Chemical Oxidation Project: Additional Injection Pilot Testing Supplemental Results (U)

Trichloroethylene (TCE) and tetrachloroethylene (PCE) are persistent at elevated concentrations in the Western Sector of the M-Area Hazardous Waste Management Facility (HWMF) groundwater plume. Migration of these chlorinated ethenes as Dense Non-Aqueous Phase Liquids (DNAPLs) occurred from the M-Area Settling Basin along geologic strata resulting in a high concentration groundwater plume in Western Sector. Pump-and-treat has been active for over 30 years at the M-Area HWMF to hydraulically contain the primary sources of the plume in addition to other remediation strategies throughout the contaminated zone, like soil vapor extraction, dynamic underground stripping, groundwater recirculation wells, and bioremediation. In-situ chemical oxidation (ISCO) has been identified as a viable treatment method for removal of these volatile organic compounds (VOCs) due to the complex lithology and high concentrations in this part of the aquifer. In addition to ISCO, a new recovery well (i.e., RWM018) was also installed in Western Sector to contain the high concentration VOC plume. The ISCO projects have utilized the gradient induced by RWM018 to help plan the injection and monitoring locations. The combination of ISCO and the additional pump and treat in Western Sector with the installation of RWM018 will help to control the plume and maximize remediation efforts.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hydrogen Plus Other Alternative Fuels Risk Assessment Models (HyRAM+) (Technical Reference Manual V.4)

The HyRAM+ software toolkit provides a basis for conducting quantitative risk assessment and consequence modeling for hydrogen, methane, and propane infrastructure and transportation systems. HyRAM+ is designed to facilitate the use of state-of-the-art science and engineering models to conduct robust, repeatable assessments of safety, hazards, and risk. HyRAM+ includes generic probabilities for equipment failures, probabilistic models for the impact of heat flux on humans and structures, and experimentally validated first-order models of release and flame physics. HyRAM+ integrates deterministic and probabilistic models for quantifying accident scenarios, predicting physical effects, and characterizing hazards (thermal effects from jet fires, overpressure effects from delayed ignition), and assessing impact on people and structures. HyRAM+ is developed at Sandia National Laboratories to support the development and revision of national and international codes and standards. HyRAM+ is a research software in active development and thus the models and data may change. This report will be updated at appropriate developmental intervals. This document provides a description of the methodology and models contained in HyRAM+ version 4.0. The most significant change for HyRAM+ version 4.0 from HyRAM version 3.1 is the incorporation of other alternative fuels, namely methane (as a proxy for natural gas) and propane into the toolkit. This change necessitated significant changes to the installable graphical user interface as well as changes to the back-end Python models. A second major change is the inclusion of physics models for the overpressure associated with the delayed ignition of an unconfined jet/plume of flammable gas.

02 PETROLEUM↗

Roadmap for Advancement of Low-Voltage Secondary Distribution Network Protection

Downtown low-voltage (LV) distribution networks are generally protected with network protectors that detect faults by restricting reverse power flow out of the network. This creates protection challenges for protecting the system as new smart grid technologies and distributed generation are installed. This report summarizes well-established methods for the control and protection of LV secondary network systems and spot networks, including operating features of network relays. Some current challenges and findings are presented from interviews with three utilities, PHI PEPCO, Oncor Energy Delivery, and Consolidated Edison Company of New York. Opportunities for technical exploration are presented with an assessment of the importance or value and the difficulty or cost. Finally, this leads to some recommendations for research to improve protection in secondary networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Force-triggered, Bio-based, Sealants for Prefabricated Building Components: Towards Improved Efficiency, Performance and Sustainability

The prefabricated building construction industry has made extensive progress in expediting the manufacture of prefabricated components at offsite plants. However, this progress has not translated to the assembly of the prefabricated components at the construction site. Case in point, sealing the joints between components to prevent air leaks requires the manual application of tape, caulk, or spray foam at the jobsite, and performance is highly dependent on the skills of the installer. To reduce assembly time and improve the airtightness and waterproofness of prefabricated components, we developed a sealant that can be installed at the plant and have its curing reaction triggered at the jobsite. Additionally, we used this opportunity to explore the use of bio-based feedstocks that are abundant and not used for food. We evaluated a series of force-triggered, bio-based, high strength, and fast curing sealants, consisting of a one-part heterogeneous system. These sealants are derived from formulations with ≥80% of bio-based components, consisting of a cardanol derived diepoxy that is microencapsulated in a polymer shell and embedded in a cardanol derived amine curing agent. The microcapsule shell allows separation of the reactive species in the one-part sealant allowing a fast-curing system to remain unreacted until the right trigger is applied. When the microcapsules are activated and broken by force, the highly reactive species mix and cure, exhibiting peel strengths up to 143 ppi. The open-air shelf stability of the sealant complexes was demonstrated by peel strength values of ~16 ppi when triggering the curing reaction even after being exposed for 8 months to open air and humidity. The successful on-demand triggering of curing reactions and the shelf stability provide efficacy of these force-triggered sealants for installation on prefabricated components, storage for months prior to delivery, and assembly at the jobsite. These force-triggered bio-based sealants for prefabricated buildings could result in lower installation time and cost as well as better performance than tapes and caulks at the jobsite.

Cortes Guzman, Karen [ORNL] (ORCID:000000028793468↗

Pilot Study for Determining HVAC Fault Prevalence from Fault Monitoring Data

HVAC faults in U.S. commercial buildings are estimated to waste 0.7 quads of energy annually and many companies have deployed software at scale for fault detection and diagnosis (FDD). Yet the lack of comprehensive published data on fault prevalence makes it difficult for researchers, software developers, and building operators to target the most important types of faults and accelerate the widespread deployment of this technology. A multi-lab effort is underway to quantify the prevalence of commercial building HVAC faults. This paper describes initial analysis conducted on over 2-years of FDD data from 12 campus buildings to inform the methodology and data collection strategy of the full study. The analysis found a large variability in fault prevalence across different buildings, pieces of equipment, and fault types, many duplicate fault alarms, and challenges in validating faults with secondary data sources such as manually entered work order data. This paper also discusses the requirements for a successful full study, which necessitates the acquisition of a large, diverse dataset, from buildings that vary in end-use, climate region, and installed FDD software platform, as well as robust validation data easily linked to the FDD data. It is especially important to perform this analysis on data from multiple FDD providers and building owners to ensure that the results are agnostic to the software methodology used and building-specific settings. Future work will present the results of the full study, which will contain data from several different partner organizations, spanning a large proportion of U.S. climate zones.

Newman, Sarah F.↗

Implementation of a System of Gamma Imagers for Measuring Plutonium Holdup

The Surplus Plutonium Disposition (SPD) project is an effort to dilute and dispose of many tonsof weapons grade plutonium. This work will take place in a shielded glovebox to protect workers fromradiological dose. Accurate measurements of the holdup, or material left behind, in the gloveboxes is im-portant for Nuclear Material Control and Accountancy, worker dose minimization, criticality safety, andprocess monitoring. Shielding around the gloveboxes presents an obstacle for the traditional GeneralizedGamma Holdup (GGH) method. The uncertainties associated with that method, at around 28%, arealso detrimental since the amount of holdup must be kept below an established limit with a high level ofconfidence.Passive gamma-ray imaging provides a more complete depiction of the distribution of radioactivematerials. Recent refinement of the method has demonstrated that quantitative information can beextracted from the images with a well-characterized system. A permanently installed system of gamma-ray imagers is currently being developed to measure plutonium holdup in the SPD gloveboxes. Thispaper will report on progress with the development of this system.This application requires that the features of current commercially available instruments from H3Dand PHDS, optimized for measurement performance in a mobile application, be translated into theconstraints of the operational environment with fixed installations. The interaction between facilityconstraints and measurement capabilities will be addressed.A series of measurements with plutonium sources in a mocked-up glovebox geometry with imagersmounted above the ceiling of the glovebox have been taken. Imager performance with respect to angularresolution, minimum measurement time for quantification, and signal-to-noise ratio with a multitudeof sources will be evaluated for those measurements. A series of prototypes of user interfaces will bepresented for display of the data to its various consumers for the purposes of Nuclear Material Controland Accountancy, worker dose minimization, criticality safety, and process monitoring.

Schmitt, Kyle↗

Development and Preliminary Analysis of a U.S. Geothermal Heat Pump Installation Database

This paper seeks to addresses the significant gap in the literature regarding the installation and adoption of geothermal heat pump (GHP) systems in the United States. While the "2021 U.S. Geothermal Power Production and District Heating Market Report" published by the National Renewable Energy Laboratory (NREL) focused on direct-use geothermal district heating systems, it did not include an analysis of GHP installations (Robins et al. 2021). To bridge this gap, NREL has compiled a novel database currently containing 70,470 records of GHP installations, primarily sourced from state well permits and small-scale studies. Our methodology emphasizes the collection, cleaning, and standardization of data, addressing challenges such as inconsistent reporting formats and privacy concerns. Despite limitations in data on capacity, costs, and performance, our preliminary geospatial analysis reveals insights into the distribution of GHP systems across urban and rural areas and climate zones. The paper highlights the importance of publicly accessible data for advancing GHP technology adoption with a discussion of existing data sources and their limitations, advocating for improved collaboration between NREL and industry stakeholders.

data collection↗

Development of the high energy engineering X-ray (HEX) superconducting wiggler, magnetic measurement, installation, and commissioning

The High energy Engineering X-ray (HEX) diffraction beamline at the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Lab (BNL) is the first high-energy beamline capable of reaching 200 keV for a monochromatic beam. With the 3 GeV electron beam energy for the NSLS-II ring, only the superconducting wiggler (SCW) producing greater than 4 T peak field can cover these ranges with a sufficient number of photons. The 1.2 m-long HEX-SCW has a period length of 70 mm and a field strength on-axis of 4.3 T. It utilizes no liquid helium, and the vertical aperture size of the electron beam vacuum chamber is 8 mm. Unlike regular undulators/wigglers, there is no standard configuration for the magnetic measurement system for superconducting insertion devices. The NSLS-II Insertion Devices group has developed, in collaboration with the vacuum group, a novel in-vacuum Hall mapper with a 1.75 m in-vacuum linear motor and an in-vacuum flip coil system utilizing many commercial-off-the-shelf products. The measurements were conducted at the BNL, and the device was installed in the ring and commissioned. Here, this paper provides a description of the SCW and its magnetic measurement systems, as well as a brief account of the installation and commissioning efforts.

36 MATERIALS SCIENCE↗