Search NASA⌕ Search

SEARCH · Search NASA

Results for “Wolter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Grazing incidence metal optics for the Berkeley Extreme Ultraviolet Explorer satellite - A progress report

The four flight Wolter-Schwarzschild mirrors currently under fabrication for the Extreme Ultraviolet Explorer (EUVE) satellite are described. The principal figuring operation of these grazing incidence metal mirrors (gold over nickel on an aluminum substrate) is carried out by diamond turning at the Lawrence Livermore National Laboratories. Turning has been accomplished and optical testing results analyzed for three of the mirrors. As-turned values of 1.7 arc sec full width at half maximum (FWHM) and half energy width (HEW) of 5 arc seconds in the visible have been achieved. These results illustrate the great potential of precision fabrication technology for the production of large grazing incidence optics.

Finley, D.↗

Spectral slicing X-ray telescope

Layered synthetic microstructure (LSM) X-ray optics is investigated as a system for coupling a conventional glancing incidence X-ray mirror to a high sensitivity X-ray detector. It is shown that, by the use of figured LSM optics, it is possible to magnify the X-ray image produced by the primary mirrors so as to maintain their high inherent spatial resolution. The results of theoretical and design analyses of several spectral slicing X-ray telescope systems that utilize LSM mirrors of hyperboloidal, spherical, ellipsoidal, and constant optical path aspheric configurations are presented. It is shown that the spherical LSM optics are the preferred configuration, yielding subarcsecond performance over the entire field. The Stanford/Marshall Space Flight Center Rocket X-ray Telescope, which will utilize normal incidence LSM optics to couple a Wolter-Schwarzschild primary mirror to high resolution detectors for solar X-ray/EUV studies, is discussed. Design diagrams are included.

Hoover, R. B.↗

Computer controlled polishing and testing of a glancing incidence telescope

The elements of a Wolter type II telescope have been fabricated using a small area tool in a computer controlled facility. The absolute radius of the mirrors can be established to 0.812 micron, and relative heights on the surfaces can be determined to 0.016 micron. The primary has a 0.041-micron rms surface error, and the secondary has a 0.054-micron surface error.

Thomas, R. J.↗

Telescope technology for the Far Ultraviolet Spectroscopic Explorer (FUSE)

Preliminary engineering studies are in progress to define a telescope for FUSE. General science objectives include high resolution spectroscopy in the 900-1200 A spectral region, low or moderate resolution spectroscopy in the 100-900 A range, and long slit imaging over a 1-arcmin field at a spatial resolution of 1 arcsec. Telescope design studies indicate that a 1-m-diameter Wolter-Schwarzschild type II glancing-incidence telescope with an effective collecting area of 3000 sq cm is required to meet the primary science objectives. A baseline optical design has been completed, and initial alignment sensitivities derived to begin the process of error allocation for the entire system.

Osantowski, J. F.↗

The AXAF technology mirror assembly program - An overview

The manufacture and testing of the Technology Mirror Assembly (TMA), a prototype Wolter I telescope scaled to the dimensions of the innermost element of the High-Resolution Mirror Assembly for the NASA Advanced X-ray Astrophysics Facility (AXAF), are reviewed. Consideration is given to the grinding, polishing, coating, and assembly of the zerodur TMA blanks, the TMA mount design, and the test procedures used at the MSFC X-ray Calibration Facility. Test results indicate FWHM resolution less than 0.5 arcsec, but with significant near-field scattering attributed to ripple; further long-lap polishing is suggested.

Wyman, Charles L.↗

The Advanced X-ray Astrophysics Facility

NASA's Advanced X-ray Astrophysics Facility (AXAF), scheduled for launch in the early 1990s, will be an X-ray observatory built around a large-area, high-resolution grazing incidence X-ray telescope. The heart of the AXAF will be an X-ray telescope consisting of six nested Wolter type I paraboloid-hyperboloid pairs ranging in diameter from 0.6 to 1.2 m. The rsulting geometric collecting area will be 1700 sq cm and the focal length will be 10 m. Potential AXAF instruments are presented.

Weisskopf, Martin C.↗

An extreme ultraviolet telescope with no soft X-ray response

While EUV grazing incidence telescopes of conventional design exhibit a substantial X-ray response as well as an extreme UV response, and existing bandpass filters for the transmission of radiation longward of 400 A also transmit soft X-rays, the grazing incidence telescope presented suppresses this soft X-ray throughput through the incorporation of a Wolter Schwarzschild Type II mirror with large graze angles. The desirable features of an EUV photometric survey telescope are retained. An instrument of this design will be flown on the EUE mission, in order to make a survey of the sky at wavelengths longer than 400 A.

Finley, David S.↗

An analysis of two classes of grazing incidence mirrors for use with Rowland circle spectrometers

Results are presented of a comparative analysis of Hettrick Bowyer Type II (HBII) and Wolter-Schwarzschild Type II (WSII) optics for use with Rowland circle spectrometers. The HBII can substitute, with few exceptions, for a WSII in any Rowland circle with little change in spectrometer performance or design. However, the HBII telescope offers several clear advantages over the WSII in these configurations. Because the HBII employs a virtual focus, it requires a much shorter instrument length than a WSII. For example, a 3-m Rowland circle spectrometer, fed by an optimized, f/10, 1-m diameter WSII, has a total instrument length of 6 m. If a HBII is used to feed the identical spectrometer, the entire instrument length can be as little as 3 m. In addition, the improved imaging gained with the larger graze angles of the HBII design results in better resolution in slitless operation modes.

Green, James↗

Grazing incidence optics; Proceedings of the Meeting, Orlando, FL, Apr. 3, 4, 1986

Papers are presented on the diffraction-limited performance of grazing incidence optical systems; transverse ray aberrations of Wolter type 1 telescopes; hybrid X-ray telescope systems; surface characterization of grazing incidence optics in the extreme UV and X-ray regions; and the surface roughness properties of synchrotron radiation optics. Topics discussed include the simulation of free-abrasive grinding of grazing incidence mirrors with vertical-honing and flexible blades; mirrors for the Extreme Ultraviolet Explorer; the design and development of conical X-ray imaging mirrors; thermal loading considerations for synchrotron radiation mirrors; and grazing incidence optics for synchrotron radiation insertion-device beams. Consideration is given to the interpretation of glancing incidence scattering measurements; damage processes in short wavelength coated FEL optics; the replication of grain incidence optics; and the assembly and alignment of the Technology Mirror Assembly.

Osantowski, John F.↗

The mirrors for the Extreme Ultraviolet Explorer

Flight mirrors for the Extreme Ultraviolet Explorer satellite are currently under fabrication. The grazing incidence metal mirrors are Wolter-Schwarzschild Type I and II and are figured by diamond turning. Imaging performance is excellent, with the figure after polishing for the best mirror being such that the full width-half maximum is 1.0 arc seconds and the half energy width is 8 arc seconds measured at visible wavelengths. Surface finish, as determined from scattering measurements in the extreme ultraviolet, is about 20 A rms.

Finley, David S.↗

Electroformed grazing incidence X-ray mirrors for a mirror array telescope

Grazing incidence Wolter type I mirrors for higher-energy X-rays have been replicated from two superpolished mandrels by electroforming. Single mirrors and a nested pair were tested with 1.5- and 6.4-keV X-rays, and their subminute of arc resolution and reflectivity close to the theoretical values are confirmed. The design of the mandrels, the mirror mounting scheme, and results of the X-ray test are presented. The microroughnesses of the mirrors measured using an optical profilometer were compared with the X-ray test results.

Ulmer, Melville P.↗

Optical surface evaluation by soft X-ray scattering

During the fabrication of the mirrors for the Extreme Ultraviolet Explorer (EUVE), methods for evaluating the surface quality of the optics have been developed. Measurement of soft X-ray scattering profiles allows for the determination of the surface roughness and correlation lengths for highly polished metal surfaces. With this method, the surface parameters for one of the Wolter Schwarzschild type I mirrors that had been fabricated for the EUVE mission have been determined. The techniques employed, the theoretical basis for the method, and the data that had been taken are presented. The measurements show that the best mirrors have a surface roughness of 20A rms or less.

Green, James C.↗

The measured performance of a grazing incidence relay optics telescope for solar X-ray astronomy

The design, fabrication, and test performance of a grazing-incidence diverging magnifier (GIDM) for use in high-resolution X-ray imaging of the solar corona are described. The GIDM, designed to be mounted in front of the focus of a 30.48-cm Wolter-Schwarzschild primary, is an Ni-coated Be hyperboloid-hyperboloid structure of principal diameter 3.15 cm; the two components are mounted on a central steel plate which acts as a support and spacer. The combined instrument has overall length 1.9 m, effective focal length 5.4 m, and plate scale 26.0 micron/arcsec. In point- and line-source measurements in an 89.5-m vacuum test facility, the on-axis resolution is shown to be equal to that of the primary alone. The field of view for 1-arcsec resolution is limited to 1.25 arcmin in radius, but the effective-area limitation is less significant when CCD detectors of high quantum efficiency are used instead of film.

Moses, Dan↗

Fabrication of imaging X-ray optics

The design, fabrication, and performance of optics for X-ray astronomy and laboratory applications are described and illustrated with diagrams, drawings, graphs, photographs, and sample images. Particular attention is given to the Wolter I telescope developed for spectroscopic observation of 8-30-A cosmic X-ray sources from a rocketborne X-ray Objective Grating Spectrometer; this instrument employs three nested paraboloid-hyperboloid mirrors of 5083 Al alloy, figured by diamond turning and covered with a thin coating of acrylic lacquer prior to deposition of a 40-nm-thick layer of Sn. In calibration tests at NASA Marshall, the FWHM of the line-spread function at 1.33 nm was found to be 240 microns, corresponding to 21 arcsec. Also presented are the results of reflectivity measurements on C and W multilayers sputtered on Si and fusion glass substrates.

Catura, R. C.↗

Surface evaluation of the grazing incidence mirrors for the Extreme Ultraviolet Explorer

The EUV scattering from the Wolter-Schwarzschild type I short wavelength scanner mirror aboard the Extreme Ultraviolet Explorer is measured, and the results are used to evaluate the surface microroughness of the mirror. It is found that the most likely values for the mirror surface are sigma = 20 A, and rho = 40 microns. These results are consistent with previous estimates, but with a higher degree of certainty. The full-scale simulation presented here allows over 99 percent of the light distribution to be reasonably modeled.

Green, James↗

Aberrations for grazing incidence telescopes

The wavefront aberration polynomial and transverse ray aberration expansions will be derived for grazing incidence two-mirror Wolter telescopes including all paraboloid-hyperboloid and paraboloid-ellipsoid combinations. The reference sphere is determined with the help of the principal surface of the telescope, and the aberration polynomials will be given as functions of the coordinates of the ray intersection with the reference sphere. Third -and some of the fifth-order and seventh-order aberration terms will be analyzed. Also, the well-known relationship between wavefront aberration polynomials and transverse ray aberration polynomials will be verified.

Saha, Timo T.↗

An electroformed mirror array for high energy X-ray astronomy

A design for a mirror array telescope for high energies with almost 1000 sq cm effective area at 7 keV is described. Briefly, it consists of 36 modules. Each module contains Wolter I mirrors nested 6 deep. The system is small enough to be flown on an Aries rocket. With the current mirrors, the angular resolution at high contrast is 20 arcsec and the half power diameter for images is 1.5 arcmin at 1.5 keV and 3.5 arcmin - 4 arcmin at 7 keV. Plans to improve upon this performance are discussed.

Ulmer, Melville P.↗

The flight test of a grazing incidence relay optics telescope for solar X-ray astronomy utilizing a thinned, back-illuminated CCD detector

The new AS&E Ultrahigh Resolution Soft X-ray Solar Research Rocket Payload has been successfully flown twice on Black Brant IX Sounding Rockets from White Sands Missile Range. These flights, conducted on 15 August 1987 and 11 December 1987, provided the first test of the new payload which consists of 3.8X magnifying hyperboloid-hyperboloid grazing incidence relay optic used in conjunction with an existing Wolter-I primary mirror. An RCA SID 500 series CCD detector was utilized in a thinned, back-illuminated configuration for recording the images. The 5.4 m effective focal length of the compound optics system resulted in a plate scale of 1 arc second per pixel which is comparable to the inherent resolution of the primary mirror. These flights represent the first use in X-ray astronomy of either of these two new technologies. These observations are presented with comparison to laboratory measurements and theoretical expectations of the instrument performance.

Moses, J. Daniel↗