Search NASA⌕ Search

SEARCH · Search NASA

Results for “X-ray focusing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Cosmic structure strikes back: The elimination of vector-mediated nonstandard interaction models as a mechanism for sterile neutrino dark matter production

We revisit sterile neutrino production enabled by nonstandard interactions (NSIs) among active neutrinos mediated by new bosons. We focus on vector mediators, including neutrinophilic, gauged 𝐿 𝜇 −𝐿 𝜏 , and 𝐵−𝐿 realizations, that modify in-medium dispersion and scattering, thereby altering the active-sterile conversion history. Building on a novel production framework with NSI thermal potentials and collision integrals, we compute nonthermal phase-space distributions across sterile neutrino mixing and NSI parameters and map each point to an equivalent thermal warm dark matter particle mass 𝑚 th via linear theory transfer function fitting with the cosmological structure formation Boltzmann solver. This enables a direct reinterpretation of state-of-the-art structure formation limits from Milky Way satellites, strong lensing, and the Lyman-𝛼 forest. These limits, in conjunction with x-ray decay searches, as well as results from a wide variety of particle physics experiments allow for a more complete examination of these models. We find that these vector-mediated models are ruled out when the full combination of current constraints, listed above, are taken into account. NSI scalar-mediated models and models with low reheating temperatures remain viable.

cosmology↗

Kramers nodal line in the charge density wave state of YTe 3 and the influence of twin domains

Recent studies have focused on the relationship between charge density wave (CDW) collective electronic ground states and nontrivial topological states. YTe 3 , a nonmagnetic quasi-two-dimensional chalcogenide, has been reported to exhibit a CDW state below 334 K. Using angle-resolved photoemission spectroscopy (ARPES) and density functional theory (DFT), we establish that YTe 3 is a CDW-induced Kramers nodal line (KNL) metal, a recently proposed topological state of matter. Scanning tunneling microscopy and low energy electron diffraction reveal two orthogonal domains, each with a unidirectional CDW and a similar wave vector (𝐪 CDW ). When the influence of twin domains is considered, the effective band structure (EBS) computations that utilize DFT-calculated bands using a noncentrosymmetric structure determined by x-ray crystallography, show excellent agreement with ARPES. The noncentrosymmetry of YTe 3 is established by Raman spectroscopy. The Fermi surface and ARPES intensity plots show weak shadow bands displaced by 𝐪 CDW from the main bands. Furthermore, these are linked to CDW modulation, as the EBS calculation confirms. Bilayer split main and shadow bands suggest the existence of crossings, according to theory and experiment. DFT bands, including spin-orbit coupling, indicate existence of a KNL along the Σ direction from multiple crossings of bands dispersing perpendicular to it. Additionally, doubly degenerate bands are only found along the KNL at all energies, with some bands dispersing through the Fermi level.

Angle-resolved photoemission spectroscopy↗

Organic colloid composition in variable-redox porewaters within a mountainous floodplain

Redox gradients, often driven by changes in sediment moisture levels in porous, heterogeneous groundwater systems, create dynamic conditions that may promote the production and transport of colloids within natural waters. While much research has focused on the inorganic composition of colloids, the organic composition remains less well understood. Organic matter (OM) in colloids may associate with minerals, complex metal ions, and serve as an electron donor for microbial respiration; therefore, its composition is of high interest. We examined the composition of porewater OM along a redox gradient in a riparian soil located along the Slate River in Crested Butte, Colorado, USA as a function of depth (90, 130, 200, and 350 cm below ground surface). All depths were oxic to suboxic, except 200 cm, where the products of iron and sulfate reduction were observed concomitant with an increase in dissolved and/or colloidal OM, pH, alkalinity, and conductivity. We investigated the composition of porewater using correlated scanning transmission X-ray microscopy and transmission electron microscopy. We observed a change in the OM chemistry from carboxylate-rich at the 200 cm depth (where it was also enmeshed with non-crystalline iron) to phenol- and substituted-aromatic-rich at other depths. Radiocarbon dating revealed carbon in porewater at 200 cm was younger than depths above and below. Soil porewater can flow down into the underlaying gravel bed during baseflow conditions, thus we speculate whether riparian porewater could transport iron- and carboxylate-rich organic colloids into surrounding surface waters through the gravel bed conduit.

Alpine floodplain↗

Data from Stewart et al. 2026 "Organic Colloid Composition in Variable-Redox Porewaters within a Mountainous Floodplain"

Redox gradients, often driven by changes in sediment moisture levels in porous, heterogeneous groundwater systems, create dynamic conditions that may promote the production and transport of colloids within natural waters. While much research has focused on the inorganic composition of colloids, the organic composition remains less well understood. Organic matter (OM) in colloids may associate with minerals, complex metal ions, and serve as an electron donor for microbial respiration; therefore, its composition is of high interest. We examined the composition of porewater OM along a redox gradient in a riparian soil located along the Slate River in Crested Butte, Colorado, USA as a function of depth (90, 130, 200, and 350 cm below ground surface). All depths were oxic to suboxic, except 200 cm, where the products of iron and sulfate reduction were observed concomitant with an increase in dissolved and/or colloidal OM, pH, alkalinity, and conductivity. We investigated the composition of porewater using correlated scanning transmission X-ray microscopy and transmission electron microscopy. We observed a change in the OM chemistry from carboxylate-rich at the 200 cm depth (where it was also enmeshed with non-crystalline iron) to phenol- and substituted-aromatic-rich at other depths. Radiocarbon dating revealed carbon in porewater at 200 cm was younger than depths above and below. Soil porewater can flow down into the underlaying gravel bed during baseflow conditions, thus we speculate whether riparian porewater could transport iron- and carboxylate-rich organic colloids into surrounding surface waters through the gravel bed conduit. This data package includes geochemical data (.csv) as a function of depth from porewaters in OBJ1. Measurements included are pH, conductivity, TOC, Fe concentration, sulfate concentration, dissolved oxygen. Additionally radiocarbon dating age of carbon in samples is provided. Additionally, this dataset contains metadata files (.csv) describing the methods, file contents, and column headers.

alpine floodplain↗

Correlating Surface Processing of Nb Superconducting RF Cavities with the Evolution of Surface Electronic States

Superconducting-radio frequency (RF) cavities provide an efficient way to accelerate particle beams with extremely high acceleration gradients while generating very small power dissipation. The few nanometers of the surface play a critical role in defining the RF performance of superconducting Nb based cavities. Over the past two decades, several pioneering surface treatment and processing methods have emerged, enabling remarkable improvements in superconducting cavity performance by simultaneously achieving high quality factors with increasing maximum acceleration gradients. These processing approaches include chemical polishing, distinct multi-step thermal treatments under ultra-high vacuum (UHV) conditions over low to high temperature regimes, as well as high-temperature treatments under controlled nitrogen atmospheres. Beyond their macroscopic impact on RF performance, these methods produce distinct surface oxide configurations characterized by different valence states, oxide thicknesses, chemical uniformity, and oxygen concentration profiles extending into the near-surface bulk of niobium. In this work, we are trying to understand how the surface-processing methods and the resulting oxide/oxygen profiles affect the electronic structure of surface and the mechanism of superconductivity. Using a combination of X-ray photoemission and X-ray absorption spectroscopies, we investigate how the valence-band structure and the electronic density of states (DoS) near the Fermi level evolve under different surface treatments. By employing tunable photon energies across multiple elemental absorption edges, we use resonant photoemission to disentangle and identify the elemental contributions to specific valence-band features. Our observations show that different surface-processing methods lead to distinct temperature evolutions of the DoS and valence-band states near the Fermi level. Our results suggest variations in different Nb-O orbital hybridizations in distinct processes and point towards the possibility of different underlying mechanisms of superconductivity governed by surface chemistry and oxide configuration. We also correlate these distinct superconducting mechanisms with RF cavity performance, specifically focusing on measured surface resistance, the nature of the Q-slope, and quench fields observed in superconducting RF measurements. These results will enable us to identify the potential limiting factors and relevant controllable parameters that can be further optimized to improve the performance of superconducting RF cavities.

Tripathi, Malvika [Fermilab] (ORCID:00000001989251↗

Linking Domain Structure Evolution at a Grain Boundary to Piezoelectric Response via Nano‐Diffraction

Electric-field-induced domain structure switching in a 1 𝜇⁢m -thick Pb 0.99 (Zr 0.45 Ti 0.55 ) 0.98 Nb 0.02 O 3 (Nb-doped PZT) bicrystal film was characterized in situ via nano-focused synchrotron diffraction. The epitaxial film was deposited on a (100) SrTiO 3 bicrystal substrate. The changes in domain structure were mapped within a 5 𝜇⁢m × 5 𝜇⁢m area at and around an in-plane tilt-type (23.6°) grain boundary with 50 nm spatial resolution. Rocking curves collected at each point of the mapped area provided the ability to reconstruct spatially-varying three-dimensional (3D) reciprocal space maps around the grain boundary. The 3D reciprocal space maps reveal how different tilted 𝑎 -type domain variants interact with the grain boundary as a function of increasing electric field. Initially, a subset of 𝑎 -type domain variants with their polarization vectors largely orthogonal to the grain boundary were found in greater abundance within 570 nm of the grain boundary, possibly due to X-ray beam-induced local increases in the electrical conductivity, but after the coercive field was exceeded, reconfiguration of the ferroelastic domains was observed. The spatially-varying reciprocal space maps also facilitated evaluation of the strain field across the mapped area, along with 𝑑 33,𝑓 . Significant spatial heterogeneity of strain and 𝑑 33,𝑓 are observed, especially at the coercive field, which was attributed to maintaining deformation compatibility and correlated ferroelastic switching.

36 MATERIALS SCIENCE↗

Geology of the One Earth Energy Site

The One Earth Energy site is one of two sites in the Illinois Storage Corridor (ISC) project. The objectives of the ISC project is to accelerate commercial deployment of carbon capture utilization and storage at two individual sites and receive approvals for Underground Injection Control (UIC) Class VI permits for construction at each site. At the One Earth Energy site, an extensive data collection program was undertaken, which included the drilling of a test well (One Earth Energy #1 [OEE #1]), four 2D seismic lines, and a small 3D seismic survey. The OEE #1 well was drilled in 2022 and acquired extensive core, log, and testing data to characterize the subsurface geology of the site. Coring was focused on the storage interval, the Mt. Simon Sandstone, and the confining interval, the Eau Claire Formation. The core and log data were used to evaluate the sedimentology and sequence stratigraphy, as well as to develop the conceptual geologic model. This report includes the geological summaries of the Mt. Simon Sandstone and the Eau Claire Formation. The extensive analysis of the log data is included in the petrophysical section, showing ranges of porosity, estimated pore size, and the mineral content of selected zones in the well. The separate petrographic technical report entitled “Petrographic and Advanced Geologic Characterization Report on One Earth Energy #1 (API# 1211325373)”, report number DOE-UIUC-0031892-04, details thin section point-counting analysis that includes mineralogical and pore space analysis, including grain size analysis, annotated thin section photomicrographs, scanning electron microscopy (SEM) with energy dispersive X-ray spectroscopy (EDS), and statistics of grain size analysis on Mt. Simon thin sections from OEE #1. The final OEE #1 well data to be included in this geology report is the routine core analysis of both whole core plugs and rotary sidewall core plugs. In addition to the OEE #1 well, four 2D seismic lines and a small 3D survey were acquired as part of the overall subsurface geological characterization. This geology report references the seismic interpretation report, entitled “One Earth Energy Site Seismic Interpretation Task 5.0”, report number DOE-UIUC-0031892-07. This report details the stratigraphic and structural interpretation of the 2D and 3D seismic data acquired at the One Earth Energy site. The 2D seismic data was acquired in 2019 and 2021, and the 3D survey was acquired in 2022. The objectives of the seismic programs were to contribute to the subsurface characterization of the Mt. Simon-Eau Claire Storage Complex by evaluating the continuity of potential storage reservoirs and containment intervals across the project area, and to determine if any geologic features are present that would increase containment risk to the proposed carbon storage project.

09 BIOMASS FUELS↗

Constraining hydrodynamic models of inertial confinement fusion implosions using capsule surrogate experiments

We conduct capsule surrogate experiments at the National Ignition Facility to calibrate radiation hydrodynamic simulations to infer hydrodynamic conditions that are not observable in indirect drive ignition implosions. We tune the simulations by applying laser power and cross beam energy transfer (CBET) saturation multipliers to match the observables from capsule surrogate experiments. Shock timing, velocity, and symmetry are measured in liquid D 2 filled Keyhole capsule surrogate experiments and implosion trajectory, stagnation time, and shape time history are measured in in-flight 2D backlit x-ray radiography experiments (“2DConA”) of D 2 gas filled capsule implosions. Calibrated simulations suggest that the N210808 ignition implosion (fusion target gain = 0.7) had a shell mass remaining at stagnation of less than the nominal %5 (3.8%) and resulted in less confinement. For N221204, the shell was made 5.75 μm thicker to trade implosion velocity for increased confinement and resulted in a target gain = 1.5 with a shell mass remaining of 5.7%. Furthermore, a single adjusted model can reproduce all shock timing data as changes are made to shell thickness (79–85 μm) and laser wavelength separation (1.8–4.0 Å). However, for the 2DConA implosions, a 5% variation in the peak power laser multipliers and a 30% variation in late-time CBET between experiments are needed to match the observed stagnation times, in-flight $P_2$ shape, and hot-spot $P_2$ shape. While progress is being made to improve the models in simulations using focused experiments, capsule surrogate experiments will continue to be needed to optimize future ignition designs.

Lasers↗

Mechanical Behavior of Neutron Irradiated Refractory Multi-Principal Element Alloys Processed via Spark Plasma Sintering

The search for advanced materials capable of withstanding the extreme conditions of Generation IV reactors is a critical area in materials science research. These reactors operate under severe environments, including high temperatures, corrosion, stress, and irradiation damage. Consequently, there is a need for innovative alloy systems to ensure the reliability and longevity of proposed Generation IV reactor components. Refractory multi-principal-element alloys (RMPEA) have emerged as a promising candidate due to their exceptional properties. These alloys, characterized by their composition of multiple principal elements in near-equiatomic ratios, exhibit superior resistance to irradiation damage, reduced void swelling, enhanced microstructural stability, and minimal irradiation-induced hardening. While initial studies on RMPEAs have shown promising results, most research has been limited to thin films, nanocrystalline microstructures, and ion irradiation, which do not accurately represent the behavior of bulk materials. To address this gap, our research focused on the neutron irradiation of bulk RMPEAs. We aim to conduct comprehensive post-irradiation examinations (PIE) of RMPEAs irradiated at the Advanced Test Reactor at Idaho National Laboratory. The RMPEAs were synthesized using spark plasma sintering (SPS) with mechanically alloyed metallurgical powder. The RMPEA specimens are a MoNbTi alloy system with additions of -Zr, and -ZrV. Furthermore, PIE consisted of mechanical testing and advanced materials characterization. The mechanical testing consisted of sub-sized tensile testing, micro- and nano- indentation. Microstructural characterization included scanning electron microscopy and transmission electron microscopy. Mechanical testing coupled with advanced microscopy techniques provides insight into phase morphology and its effects on the mechanical properties of the RMPEA specimens. The results indicate that both pristine and irradiated RMPEA specimens exhibited brittle behavior during tensile testing, which can be attributed to their heterogeneous microstructure. The SPS manufacturing process did not include any post treatment, which resulted in a heterogeneous microstructure. Energy-dispersive X-ray spectroscopy revealed the presence of intermetallic such as laves phases within the microstructure. Specifically, Ti-rich precipitates were observed in the MoNbTi specimen, while Mo-rich precipitates were found in the MoNbTiZrV specimen. Nano-hardness testing of pristine samples showed that the laves phases exhibited higher hardness values compared to the matrix phase, suggesting that precipitate hardening is likely the dominant hardening mechanism in these specimens. The results from this work will be used to build a finite element model to predict mechanical behavior of future MPEA compositions. Thus, enabling for a streamlined approach to developing novel MPEAs for the nuclear industry.

36 - MATERIALS SCIENCE↗

Impact of nitrogen on lithium-induced corrosion and cracking of RAFM steel

The emergence of private fusion enterprises, combined with advancements in U.S. and EU ITER-TBM as well as EU DEMO liquid breeder blanket concepts, has renewed focus on the materials challenges. This study examines the compatibility of reduced activation ferritic/martensitic (RAFM) steel in liquid Lithium (Li) containing various Nitrogen (N) concentrations, tested at 600 and 700 °C for 500 and 1000 h under static conditions. Microstructural characterization revealed the corrosion-induced dissolution and precipitation in Li containing 0.082 and 0.17 wt.% N at 600 °C, while limited dissolution and precipitation were observed in N-gettered Li using zirconium (Zr) and titanium (Ti) foils at 600 °C. Tensile testing at room temperature after Li exposure revealed a decrease in strength and ductility of the RAFM steel as a function of N content in Li. Severe embrittlement was observed after 500 h in Li containing 0.17 wt.% N at 600 °C and after 500 h in hot-gettered Li at 700 °C. Chromium (Cr) depletion from the steel matrix was observed, leading to the formation of M6C-type carbides on the surface identified by electron microscopy (SEM), X-ray diffraction (XRD), in agreement with thermodynamic calculations. These findings highlight the critical materials challenges posed by liquid Li breeder blanket concepts, emphasizing the need for improved strategies to address Li-induced dissolution, precipitation, and steel embrittlement due to N contamination of the coolant.

Romedenne, Marie [ORNL] (ORCID:0000000317936561)↗

Thermoreflectance Detection of Point Defects Resulting from Focused Ion Beam Milling

Focused ion beam (FIB) milling is a commonly used tool for nanoscale material processing, such as for transmission electron microscopy (TEM) sample preparation, or the creation of fiducial markers prior to other processes and measurements. During milling, a high energy ion beam is used to remove material via sputtering. The expelled target material may return to the sample surface however, affecting subsequent measurements. Beam spreading or irradiation due to neutral gallium may also irradiate a larger area than intended. Extensive research has explored the effects of FIB milling on the prepared TEM sample, but few have looked at the effects of milling on the properties of the sample surrounding the milled region. We use multiple pump-probe laser-based techniques (time domain thermoreflectance and steady-state thermoreflectance) to measure the spatial extent of FIB-induced surface/subsurface changes on a series of silicon wafers milled at multiple currents and doses. We supplement these measurements with high-resolution scanning transmission electron microscopy, energy dispersive X-ray spectroscopy, stylus profilometry, and time-of-flight secondary ion mass spectroscopy. We find a sample surface affected by the FIB up to 1 mm from where milling occurred, with a notable dependence on the ion beam current. We also note remarkably high sensitivity to surface defects using the thermoreflectance metrologies, including detection where other measurements failed.

defects↗

Establishing the Stability of Cross-Linked Poly(ethylene oxide) Blended with Poly(pentyl malonate) against Lithium Metal Anodes

This work focuses on an electrolyte obtained by infusing linear poly(pentyl malonate) (PPM) chains into cross-linked poly(ethylene oxide) (PEO). A lithium salt is added to enable ion transport. Obtaining this electrolyte is only possible because PPM is miscible with PEO irrespective of salt concentration. The properties of this electrolyte are compared against two benchmarks: an electrolyte obtained by infusing linear PEO into cross-linked PEO and cross-linked PEO with no added linear polymer. Measurements of storage moduli and ion transport efficacies are found to be similar across the three electrolytes, suggesting similar stability behavior against lithium metal anodes, based on current theoretical models. Instead, the PPM infused electrolyte outperforms the other two electrolytes. In the cycling tests, the current supported by the PPM infused electrolyte was a factor of 20 higher than that of the PEO infused electrolyte and a factor of 4 higher than that of the cross-linked PEO electrolyte. In the unidirectional plating experiments, the other two electrolytes fail after about 4 h or less, while the PPM containing electrolyte did not fail during the 140 h testing period. Insight into the nature of failure modes was obtained using synchrotron hard X-ray microtomography.

Gido, Lily [University of California, Berkeley]↗

Boride-based Ceramic Super-high Temperature Thermocouples in Harsh Environments (Final Scientific/Technical Report)

An electromotive force (emf) can be generated along a temperature gradient between the cold end and hot end of a thermoelectric material, termed the Seebeck effect. Based on the Seebeck effect, metallic alloys have been extensively employed to detect temperatures for centuries, named thermocouples. However, commercially available thermocouple alloys suffer from limitations, such as oxidation, chemical degradation, and poor long-term stability under high-temperature harsh environments. This DOE-funded project aimed to develop high-temperature, chemically tolerant thermocouples suitable for operation in extreme environments relevant to semiconducting thermoelectric materials. The research focused on boride-based semiconducting thermoelectric compounds as candidates for next-generation thermocouples with enhanced oxidation resistance, chemical stability, and thermal robustness under conditions representative of charcoal-fired electricity facilities. During the funded years, boride materials were synthesized using an arc-plasma technique under ambient air and argon atmospheres, enabling scalable and cost-effective production compared with conventional boride fabrication methods. The synthesized borides were processed into nanostructured powders, followed by consolidation into dense bulk materials using a spark plasma sintering (SPS) bottom-up approach. Comprehensive characterization was performed, including microstructural analysis, electrical transport measurements, and optical and thermal property evaluation. Both p-type and n-type boride electric legs were fabricated and integrated into boride-based thermocouples. The thermal and irradiation stabilities of the boride nanomaterials and bulk thermoelectric materials were systematically evaluated to assess suitability for long-term operation in harsh environments. Additionally, 12 students were broadly hands-on trained spanning the full research workflow, including word processing and technical editing (e.g., LATEX for manuscript and poster preparation), data collection and analysis (using Python and related libraries and hardware interfaces), sample preparation (including arc-plasma synthesis and spark plasma sintering), and advanced characterization techniques (such as X-ray diffraction, UV–vis spectroscopy, electron microscopy, differential thermal analysis (DTA), and Seebeck coefficient measurements, etc). Overall, this project demonstrated the feasibility of boride-based thermoelectric materials as durable high-temperature thermocouples, providing a promising pathway toward robust temperature sensing technologies aligned with DOE energy infrastructure and extreme-environment monitoring needs.

20 FOSSIL-FUELED POWER PLANTS↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Co‐Electrolysis of CO 2 and H 2 O to Syngas on Bimetallic Pd x Cu 1‐ x Catalysts for Tandem Thermochemical Conversion to Carbon Nanofibers

Electrification of chemical production using renewable energy and abundant feedstocks offers a promising pathway for decarbonizing the chemical industry. Current efforts on CO 2 valorization largely focus on making chemicals and fuels. Here, to help achieve net-negative emissions through long-term carbon storage, this study aims to develop efficient electrocatalysts for a tandem electrochemical-thermochemical process to convert CO 2 into carbon nanofibers (CNFs). CO 2 and water are first electrochemically reduced in a membrane electrode assembly (MEA) electrolyzer to produce syngas (CO + H 2 ), which is subsequently fed into a thermochemical packed bed reactor to facilitate CNF growth. This work systematically evaluated Pd x Cu 1-x bimetallic electrocatalysts to assess the effect of Pd–Cu alloying on enhancing syngas production while reducing Pd loading. Transmission electron microscopy and Raman spectroscopy confirmed the formation of high-purity, crystalline CNFs, regardless of the syngas composition from the MEA. In situ X-ray absorption spectroscopy and X-ray diffraction measurements revealed that increasing Cu content in the Pd x Cu 1-x alloy progressively inhibited palladium hydride formation, consistent with DFT calculations on the stability of Pd x Cu 1-x under reducing electrochemical potentials.

58 GEOSCIENCES↗

Tuning optical properties and local lone-pair off-centering in “hollow” FA 1− x { en } x Pb η−y Sn y Br 3 perovskites

Hollow metal halide perovskites, while a relatively recent discovery, have already been shown to push the boundaries of tuneability within an inherently limited compositional space. Here, we further expand our knowledge of these complex materials demonstrating the ability to control optical properties and local structure, notably lone-pair induced off-centering. We focus on the mixed metal FA 1−x en x Pb η−y Sn y Br 3 hollow perovskites. These compounds have wide ranging optical gaps from 1.9 eV (deep red) to 2.6 eV (light yellow), combining the anomalous bandgap red-shifting of Pb/Sn mixing with the blue-shifting effects of the organic substitution. Average and local structural studies employing single crystal X-ray diffraction and total X-ray scattering pair distribution function analyses respectively suggest strong incoherent off-centering distortions that are locally correlated with Sn concentration. The inclusion of ethylenediammonium dications appears to regulate metal off-centering, opening new opportunities of research into this phenomenon.

Balvanz, Adam [Northwestern University, Evanston, ↗

First use of an InSb crystal for x-ray imaging spectroscopy of highly ionized tungsten in the Wendelstein 7-X stellarator

Advances in time and space resolved measurements of highly charged states of tungsten (W) through x-ray imaging spectroscopy have enabled investigation of impurity transport in the Wendelstein 7-X (W7-X) stellarator. The high-resolution x-ray imaging spectrometer (HR-XIS) system on W7-X utilizes the Bragg diffraction properties of a set of multiple crystals to measure a range of impurity emission lines within sections of the 1–7 Å wavelength range, including transitions of W. A new indium–antimonide crystal has been installed on the HR-XIS system to allow viewing of the 5.5–6.2 Å region focusing on emissions of W. Consequently, many bright W emission lines from W 40+ to W 47+ were observed in this wavelength range, both in plasmas with injected W and in those with only intrinsic W impurity sources, showing the high sensitivity of the diagnostic. Three W 46+ emissions correspond in wavelength and intensity with calculated photon emissivity coefficients and can be exploited for W transport and concentration applications in plasmas with T e ≳ 2.1 keV. Here, an estimate of the core W density behavior in two separate turbulence-reduced ‘high-performance’ (HP) discharges on W7-X is done using the 5.6893 Å W 46+ line. The n W behavior in HP scenarios can be explained by previous experimental results and neoclassical predictions.

XICS↗

XRISM/Resolve view of Abell 2319: Turbulence, sloshing, and ICM dynamics

Here, we present results from XRISM/Resolve observations of the core of the galaxy cluster Abell 2319, focusing on its kinematic properties. The intracluster medium (ICM) exhibits temperatures of approximately 8 keV across the core, with a prominent cold front and a high-temperature region (⁠~11 keV) in the north-west. The average gas velocity in the 3' x 4' region around the brightest cluster galaxy (BCG) covered by two Resolve pointings is consistent with that of the BCG to within 40 km s -1 ⁠ and we found modest average velocity dispersion of 230–250 km s -1 ⁠. On the other hand, spatially resolved spectroscopy reveals interesting variations. A blueshift of up to ~230 km s -1 ⁠ is observed around the east edge of the cold front, where the gas with the lowest specific entropy is found. The region further south inside the cold front shows only a small velocity difference from the BCG; however, its velocity dispersion is enhanced to ~400 km s -1 ⁠, implying the development of turbulence. These characteristics indicate that we are observing sloshing motion with some inclination angle following BCG and that gas phases with different specific entropy participate in sloshing with their own velocities, as expected from simulations. No significant evidence for a high-redshift ICM component associated with the subcluster Abell 2319B was found in the region covered by the current Resolve pointings. These results highlight the importance of sloshing and turbulence in shaping the internal structure of Abell 2319. Further deep observations are necessary to better understand the mixing and turbulent processes within the cluster.

Astronomy and AstroPhysics↗