Search NASA⌕ Search

SEARCH · Search NASA

Results for “X-ray focusing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Paraboloidal X-ray telescope mirror for solar coronal spectroscopy

The telescope mirror for the X-ray Spectrograph Spectrometer Telescope System is a sixty degree sector of an extreme off-axis paraboloid of revolution. It was designed to focus a coronal region 1 by 10 arc seconds in size on the entrance slit of the spectrometer after reflection from the gold surface. This paper discusses the design, manufacture, and metrology of the mirror, the methods of precision mechanical metrology used to focus the system, and the mounting system which locates the mirror and has proven itself through vibration tests. In addition, the results of reflection efficiency measurements, alignment tolerances, and ray trace analysis of the effects of misalignment are considered.

Brown, W. A.↗

Atmospheric, Non-Combusting Droplet Sizing and Spray Imaging Results From a Non-Proprietary Aero Gas Turbine Engine Pressure Swirl Atomizer using Shadowgraphy and Planar Laser Scatter

Members from industry and federal agencies of the United States have developed a collaborating group focused on improving the understanding of the atomization processes common to gas turbine engines. The group is aimed on providing high quality data using x-ray diagnostics in the internal geometry and the near-field dense spray as well as optical diagnostics in the visible spectrum, downstream of the nozzle. This paper reports results from one of the two non-proprietary injectors designs from the group: the primary-secondary injector. In particular, we characterize the spray from only the primary, pressure-swirl atomizing circuit using water through the nozzle. We observed Sauter mean diameter decreased with increased water pressure drop across the nozzle. SMD was also collected at three axial distances and showed decreased size with distance from the nozzle. Planar laser sheet droplet scattering provided qualitative assessment of the spray. Higher water pressure drops provided better atomization than lower pressure drops. The addition of swirling air flow through the injector alleviates and improves the atomization quality, particularly at the lower water pressure drops.

optical diagnostics↗

Analysis of Aerobee 17.012 data

The results are summarized of reduction and analysis of data acquired during the flight of NASA-Aerobee 17.012CG. This rocket was launched from White Sands Missile Range on 6 April 1974 at 0410 U.T. The primary instrument in the experiment payload was a singly focussing x-ray reflector system sensitive in the range from 0.18 to 3 keV. X-ray detectors for this system consisted of two gas flow proportional counters with fields of view defined by apertures of 0.1 deg and 0.3 deg at the reflector focus. A Bragg spectrometer utilizing KAP crystals was included in the payload with the objective of detecting the Lyman alpha line of 0 VIII at 18.97A in the Puppis supernova remanant. A 35 mm camera photographed the star field every 1.6 sec throughout the flight to provide aspect information.

Catura, R. C.↗

Plasma phenomena at magnetic neutral points

A model of the plasma focus is considered, in which large axial electric fields are induced by the imploding current sheet during the final few nanoseconds of the collapse phase. This field provides a mechanism for creation of a beam of electrons of highly suprathermal energies. For this beam, the bremsstrahlung radiation is calculated, which is expected either from electron-deuteron collisions in the focused plasma itself or from the beam as it reaches the walls of the device. Comparison with experimental results indicates that the walls are the more likely source of these hard X-rays and also find qualitative agreement of the expected angular distribution of X-rays with experiment.

Sturrock, P. A.↗

Apollo 6, Anomaly Report No. 6: Abnormal Structural Performance During Launch Phase

Approximately 2 minutes 13 seconds after lift-off of the Apollo 6 mission, abrupt changes of strain, vibration, and acceleration measurements were indicated in the S-IVB, instrument unit, adapter, lunar module, and command and service modules; photographs showed objects coming from the area of the adapter. The adapter, however, continued to sustain the required loads with no impairment of the mission. The investigation was first focused upon the understanding of the coupled vibration modes and characteristics of the launch vehicle and spacecraft.' Extensive test programs were conducted. It was eventually concluded that the adapter failure was not caused by vibration. Extensive study of the airborne photography and other evidence indicated that a large area of the adapter had lost inner facesheet from the honeycomb sandwich panels. Loads and stresses resulting from vibration were determined to be insufficient to initiate such a failure. The investigation was then directed toward determining the range of pressures that could have been trapped in the Apollo 6 adapter sandwich panels, and toward determining the tolerance of the panels to withstand pressure with various degrees of flaws such as adhesive voids and facesheet dents. The degradation effects of moisture and heat exposure on the adhesive strength were also studied and tested. These tests and analyses led to the conclusion that pressure internal to the sandwich panels could have caused the failure, if a large flaw existed. The pressure buildup would have been caused by aerodynamic heating effects on air and moisture trapped in the panel. The probable cause of the failure was found in the original ultrasonic inspection scan record of the affected adapter panel. In the center of the region where the adapter failed, horizontally along the station 709 panel splice, the record contained two thick anomalous lines extending several feet. Without an X-ray record of this region, the significance of this particular scan record cannot be fully understood. However, since all other evidence had indicated that the adhesive had to be weakened in a rather large area to initiate the failure, the investigation was focused intently upon the station 709 splices of other adapters. Sufficient information was developed to verify that deficient assembly techniques have consistently resulted in abnormalities in the structure at this station. These abnormalities were identified in adapters 12, 13, 14, 15, and 16. Before the splice abnormalities were pinpointed, corrective action was taken to reduce pressure "buildup in the honeycomb panels and to reduce heat degrading effects on the adhesive. This was done by drilling vent holes in the inner facesheet and covering the outer facesheet with cork. The adapters having identified abnormalities in the station 709 splice are being repaired, and the contractor is investigating ways of avoiding these -abnormalities in panels yet to be bonded.

Source record↗

X-ray spectrographs using radial groove gratings

A high efficiency spectrograph design for the EUV and soft X rays is presented. This grazing incidence system uses a plane surface reflection grating with rulings that are radial, like the spokes of a wheel. The grating is placed in a beam of light that is converging to a focus. The single reflection off the grating is in the conical diffraction mount ensuring maximum performance from the system. Aberrations and performance levels are discussed. The gratings can be manufactured with existing ruling engines. Sample applications to an X-ray monochromator and an EUV stellar spectrograph are discussed.

Cash, W. C., Jr.↗

Broad band X-ray astronomical spectroscopy

The Broad Band X-Ray Telescope (BBXRT) experiment has been designed for high sensitivity, moderate resolution spectrophotometry of cosmic sources in the range 0.5 to 12 keV. Principal elements are two co-aligned imaging telescopes with cooled Si(Li) detectors at each focus. The mirror design uses an approximate geometry of tightly nested, conical, foil reflectors that allow a large filling factor (high throughput) at small grazing angles (high energy response). Each detector consists of a cluster of five elements defined with grooves on a single crystal. This arrangement affords some spatial resolution as well as a means of substantial background reduction. Shuttle borne measurements will typically be of 2000 s duration for sources with a flux of 10 to the -12 erg/sq cm-s.

Serlemitsos, P. J.↗

Measuring EUV Line Emission from the Hot Interstellar Medium

In the local interstellar medium, the presence of hot gas was inferred from measurements of oxygen VI absorption in the ultraviolet, and from diffuse emission in the extreme ultraviolet (EUV) and soft X-ray regions. A spectrometer that is very sensitive to gas in this temperature range is described. The spectrometer uses an array of plane ruled gratings at grazing incidence in the extreme off plane mount. A set of Kirkpatrick-Baez mirrors focuses the conically diffracted light on to one of two microchannel plate detectors. The field of view of the instrument is 0.2 deg by 12 deg. The predicted sensitivity ranges from 50 to 200 ph/(sq cm sec str) with a resolving power of 15 to 50 over the 50 to 700 angstrom wavelength band.

Labov, S.↗

Tomographic and analog 3-D simulations using NORA

The results of two computer simulations demonstrate the feasibility of using the nonoverlapping redundant array (NORA) to form three-dimensional images of objects with X-rays. Pinholes admit the X-rays to nonoverlapping points on a detector. The object is reconstructed in the analog mode by optical correlation and in the digital mode by tomographic computations. Trials were run with a stick-figure pyramid and extended objects with out-of-focus backgrounds. Substitution of spherical optical lenses for the pinholes increased the light transmission sufficiently that objects could be easily viewed in a dark room. Out-of-focus aberrations in tomographic reconstruction could be eliminated using Chang's (1976) algorithm.

Yin, L. I.↗

Multi-anode microchannel arrays - New detectors for imaging and spectroscopy in space

Consideration is given to the construction and operation of multi-anode microchannel array detector systems having formats as large as 256 x 1024 pixels. Such arrays are being developed for imaging and spectroscopy at soft X-ray, ultraviolet and visible wavelengths from balloons, sounding rockets and space probes. Both discrete-anode and coincidence-anode arrays are described. Two types of photocathode structures are evaluated: an opaque photocathode deposited directly on the curved-channel MCP and an activated cathode deposited on a proximity-focused mesh. Future work will include sensitivity optimization in the different wavelength regions and the development of detector tubes with semitransparent proximity-focused photocathodes.

Timothy, J. G.↗

Current sheet collapse in a plasma focus.

Collapse of the current sheets in a plasma focus has been recorded simultaneously through slits parallel and perpendicular to the symmetry axis in the streak mode. The dark period following the collapse is due to the plasma moving out of the field of view. Microdensitometric measurements of intensity variation also support this conclusion. A large anisotropy is also found in the x-ray radiation pattern. Effects of different vacuum vessels were investigated.

Jalufka, N. W.↗

A focussing iron line crystal spectrometer for Spacelab

A crystal spectrometer system is described which employs conical focusing of 12 curved LiF crystal panels to minimize the detector size and reduce the background counting rate. The wavelength range from 1.70 to 1.98 A is covered, including the resonance lines of Fe XXV and Fe XXVI as well as the Fe I K-alpha line and absorption edge. Operation of the spectrometer is discussed, noting that diffracted X-rays are registered in one-dimensional position-sensitive detectors and that the arrival position of a photon in a detector is related to its wavelength due to the fixed curvature of the crystal panels in the dispersion plane. Some characteristics of the multianode position-sensitive detectors are reviewed along with the crystal arrangement and mounting. The instrument sensitivity is evaluated in relation to the strengths of 6.7-keV emission features detected by the Ariel 5 and OSO 8 proportional-counter spectrometers.

Catura, R. C.↗

Production of hard X rays in a plasma focus

A model of a plasma focus is examined wherein large axial electric fields are produced by an imploding current sheet during the final nanoseconds of the collapse phase and where the fields provide a mechanism for creating a beam of electrons of highly suprathermal energies. The expected bremsstrahlung radiation above 100 keV is calculated for such a beam, which has a power-law spectrum, both from electron-deuteron collisions in the focused plasma and when the beam reaches the wall of the device. It is concluded that, since the experimental results indicate little or no radiation above 100 keV originating in the walls, that the electrons in the beam must be decelerated after leaving the plasma and before reaching the wall. Comparisons with the results and the total energy of the device yield qualitative agreement with the expected angular distribution of hard X-rays and reasonable agreement with the total energy in accelerated electrons required to produce the observed total energy in hard X-rays by this mechanism.

Newman, C. E.↗

A moderate-resolution, wide-band, astronomical echelle spectrograph

An echelle spectrograph is described which is specifically designed for use on a 52-in. f/7.6 telescope as an instrument optimally suited for studying spectra of the faint optical counterparts to X-ray stars at moderate spectral resolution. The spectrograph is also able to accomodate a two-dimensional photon-tagging panoramic image detector so that high-time-resolution studies of the spectra of variable stars can be carried out. The equations for echelle spectrographs are summarized, and some features of the present instrument are discussed. These include its prism cross-disperser, small elliptical flat mirror, and unusually high efficiency. An iron-argon calibration spectrum obtained by pressing the film against the output fiber optics of a three-stage electrostatically focused image intensifier, a spectrum of P Cygni taken by placing the film directly in the image plane of the spectrograph, and a photon-counted image of a small section of an echellogram produced during an observation of the Ring nebula in Lyra are provided to illustrate the performance of the instrument.

Bardas, D.↗

Three mirror glancing incidence system for X-ray telescope

A telescope suitable for soft X-ray astronomical observations consists of a paraboloid section for receiving rays at a grazing angle and a hyperboloid section which receives reflections from the paraboloid at a grazing angle and directs them to a predetermined point of focus. A second hyperboloid section is centrally located from the other two surfaces and positioned to reflect from its outer surface radiation which was not first reflected by the paraboloid. A shutter is included to assist in calibration.

Hoover, R. B.↗

Microchannel detector array for X-rays and UV

Device employs sensitive photoelectric electrodes and solid-state memory, can be used at visible UV and X ray wavelengths, includes nonmagnetic proximity focusing, and is immune to high energy charged-particle background.

Timothy, J. G.↗

Optical spectrum of HDE 245770 /A0535 + 26/

Narrow-band spectrophotometric observations of HDE 245770 with the multichannel spectrometer and slit spectra obtained with the SIT digital spectrograph at the Cassegrain focus of the 5-m Hale telescope indicate that this star is of spectral type B0 with emission at H-alpha, H-beta, and probably 5876 A of He I. There is some evidence that it is of luminosity class III. The reddening is estimated in various ways and corresponds to a B-V color excess of 0.80. If the star is really a giant, its distance is approximately 1.8 kpc. No variations larger than 1% at the reported 104-x X-ray pulse period are evident in the data in visual magnitude, color, or H-alpha emission intensity. This is not surprising, since the optical star is much more luminous than the X-ray object, and the heating effect of the X-ray source (which is assumed to be one component of a binary) on the B0 star's atmosphere can produce at most a few percent modulation in visual light.

Wade, R. A.↗