Planned High-gradient Flat-beam-driven Dielectric Wakefield Experiments at the Fermilab’s Advanced Superconducting Test Accelerator

In beam driven dielectric wakefield acceleration (DWA), high-gradient short-wavelength accelerating fields are generally achieved by employing dielectric-lined waveguides (DLWs) with small aperture which constraints the beam sizes. In this paper we investigate the possibility of using a low-energy (50-MeV) flat beams to induce high-gradient wakes in a slab-symmetric DLW. We demonstrate via numerical simulations the possibility to produce axial electric field with peak amplitude close to 0.5 GV/m. Our studies are carried out using the Fermilab's Advanced Superconducting Test Accelerator (ASTA) photoinjector beamline. We finally discuss a possible experiment that could be performed in the ASTA photoinjector and eventually at higher energies.

43 PARTICLE ACCELERATORS↗

Accelerated Testing of Selected Filler Compositions

The fillers R&D program, mostly experimental, is part of a broader R&D program that includes new process modeling and performance assessment of criticality effects and the overall importance of criticality to repository performance (consequence screening). A literature research and consultation effort with experts by Hardin and Brady (2018) identified several potentially effective and workable filler materials including cements (primarily phosphate based), molten-metal alloys, and low-temperature glasses. Filler attributes were defined and the preliminary lists were compared qualitatively. Further comparative analysis will be done (e.g., cost estimates) after experimental screening has narrowed the list of alternatives. The following cement filler compositions were selected for experimental development work and accelerated testing in FY19: Aluminum phosphate cements (APCs); more specifically aluminum oxide / aluminum phosphate (Al 2 O 3 / AlPO 4 ) cements in which Al 2 O 3 serves as the filler material bound by an AlPO 4 binder formed by the reaction of Al 2 O 3 with H 3 PO 4 ; Calcium phosphate cements (CPCs); more specifically composed of pure or nearly pure hydroxyapatite (Ca 5 (PO 4 ) 3 (OH)); Magnesium potassium phosphate cements (MKPs) composed of magnesium oxide / magnesium potassium phosphate (MgO / MgKPO 4 ) cements in which MgO serves as the filler and MgKPO 4 serves as the binder formed by the reaction of MgO with monopotassium phosphate (KH 2 PO 4 ) and tricalcium phosphate ((Ca 3 (PO 4 ) 2 ); Two additional potential cement materials were explored preliminarily as the result of: (1) continued literature investigations into other filler candidates (wollastonite-based phosphate ceramic) and (2) the experimental discovery of a well-consolidated fly ash phosphate cement during the evaluation of fly ash as a potential filler material with Al 2 O 3 in APCs. Fly ash phosphate cements, more specifically in which a fly ash material composed primarily of mullite and quartz serves as the filler and is reacted with H 3 PO 4 to form amorphous phosphate phase(s) as the binder; Wollastonite aluminum phosphate cements (WAPC), specifically wollastonite / aluminum phosphate (CaSiO 3 / AlPO 4 ) in which CaSiO 3 serves as the filler material and AlPO 4 serves as the binder formed by Al(OH) 3 or metakaolin as Al sources and H 3 PO 4 or ammonium dihydrogen phosphate (ADP) (NH 4 H 2 PO 4 ) as phosphate sources. The FY19 effort focused on the optimization of compositions and subsequent processing of these five materials to achieve dense and well-consolidated monolithic samples with relatively low porosity. Once these goals were met basic material properties screening evaluations were performed including an assessment of dissolution resistance in water at elevated temperature (200 °C) and mechanical testing including unconfined compressive strength (UCS) testing. To date, the aluminum phosphate cements (APCs) appear to show the most promise for continued development. They are easily prepared and form smooth pourable slurries that remain stable for days with relatively low viscosities of several thousand centipoise (cP). They are then set at elevated temperatures (e.g., 170 °C) under ambient (0.1 MPa) or elevated pressure (~1MPa). Overall, they demonstrate the best dissolution resistance in water at elevated temperature (200 °C) and good compressive strengths. However, additional effort is required to optimize the APC slurry formulations and the process used for thermal curing these materials. The calcium phosphate cements (CPCs) can be formed at room temperature to produce a well-consolidated body. However, their slurry viscosities are very high (and difficult to measure) and they exhibit relatively short cure times of 2 to 3 hours. Also, dissolution resistance is very poor, the poorest of all the cements examined The same is the case for the small number of MKP cements fabricated; they cure very quickly (10 minutes or less) and disintegrate within a few hours upon immersion in distilled water. Surprisingly, fly ash reacts with phosphoric acid to form dense and well-consolidated cements but the mixture rapidly sets at room temperature (less than 30 minutes) and the subsequent conversion of the binder to an amorphous phosphate phase(s) as a function of temperature is complicated. Finally, the wollastonite aluminum phosphate cements (WAPC) are easily prepared and form smooth pourable slurries that remain stable for several hours. They are then set at 130 °C. A WAPC sample exhibited the highest compressive strengths of all the materials we evaluated but in general their dissolution resistance to water is poor.

36 MATERIALS SCIENCE↗

Material characterization of seven photovoltaic backsheets using seven accelerated test conditions

A variety of polymeric backsheet materials can be found in fielded photovoltaic (PV) modules, mostly based on fluoropolymer and polyethylene terephthalate (PET) materials. Cost reduction and sustainability considerations drive the recent development of alternative backsheet materials and designs [1]. In some fielded PV installations, polymeric materials are susceptible to environmental degradation in the form of backsheet cracking. To prevent backsheet degradation that can result in a module failure, thorough laboratory reliability testing is needed. In this report we studied the durability of seven commercial and experimental PV backsheets through accelerated stress testing using seven photolytic, hygrometric, and custom tests with the goal to understand if novel fluoropolymer-free backsheets are sufficiently environmentally durable to be commercialized. We divided the mechanisms observed during aging into two categories: core degradation and surface degradation. Although core degradation due to hydrolysis was observed in all commercial PET-, and polyamide (PA)-based backsheets aged with 85 degrees C/85% relative humidity, this test is unlikely to be field relevant. Photo-oxidative reactions on the exposed surface during UV weathering affected all seven backsheets regardless of the outer layer polymer material and additives. This degradation was limited to the outermost micrometers of the surface, except for backsheets containing PA-12, which resulted in surface cracking. A custom test combining UV with water spray caused the most severe backsheet degradation, including surface erosion and loss of insulating properties in polyolefin (PO)- and PA-based backsheets. This highlights the importance of combined accelerated stress testing to screen for complex backsheet degradation mechanisms. We also showed that, with material and design optimization, coextruded experimental PO-based backsheets have the potential to be a durable alternative to commercial PET- and fluoropolymer-based PV backsheets.

14 SOLAR ENERGY↗

Leveraging accelerated testing of LED drivers to model the reliability of two-stage and multi-channel drivers

The next wave of LED lighting technology is likely to be tunable white lighting (TWL) devices which can adjust the colour of the emitted light between warm white (~ 2700 K) and cool white (~ 6500 K). This type of lighting system uses LED assemblies of two or more colours each controlled by separate driver channels that independently adjust the current levels to achieve the desired lighting colour. Drivers used in TWL devices are inherently more complex than those found in simple SSL devices, due to the number of electrical components in the driver required to achieve this level of control. The reliability of such lighting systems can only be studied using accelerated stress tests (AST) that accelerate the aging process to time frames that can be accommodated in laboratory testing. This paper describes AST methods and findings developed from AST data that provide insights into the lifetime of the main components of one-channel and multi-channel LED devices. The use of AST protocols to confirm product reliability is necessary to ensure that the technology can meet the performance and lifetime requirements of the intended application.

Davis, Lynn↗

Initial performance of the magnet system in the splitter/combiner section of the Cornell-Brookhaven Energy-Recovery Linac Test Accelerator

The Cornell-Brookhaven Energy-recovery Linac Test Ac- celerator is a four-pass, 150-MeV electron accelerator with a six-cell 1.3 GHz superconducting-RF linear accelerator and a fixed-field alternating-gradient (FFAG) return loop made up of Halbach-style quadrupole magnets. The optics matching between the linear accelerator and the return loop is achieved with a conventional magnet system comprised of 50 dipole magnets and 64 quadrupole magnets in four beamlines at each end of the linac. The 42-, 78-, 114- and 150-MeV electron beams are separated into independent vacuum chambers in order to allow for the path-length ad- justment required by energy recovery. We report on the first beam tests of the initial installation of the splitter/combiner section at the exit of the linac. The vacuum system of the 42-MeV S1 line was installed during the first week of April. Nine dipole and four quadrupole magnets were installed and surveyed into position the following week, and the water cooling system was commissioned. A 6-MeV beam passed through the line on April 11 with no need for adjusting pre-set magnet excitation currents. One week later, time- of-flight measurements were used to calibrate and phase the individual superconducting RF cavities. The S1 magnet settings were then scaled up to achieve 5-cavity, 42-MeV operation through the first nine FFAG permanent-magnet quadrupoles. This initial Fractional Arc Test will conclude on May 18, when the installation of the remaining seven split- ter/combiner lines and the return loop will begin. CBETA operations are scheduled to begin in early 2019.

43 PARTICLE ACCELERATORS↗

Evaluation of Dynamic Mechanical Loading as an Accelerated Test Method for Ribbon Fatigue

Dynamic Mechanical Loading (DML) of photovoltaic modules is explored as a route to quickly fatigue copper interconnect ribbons. Results indicate that most of the interconnect ribbons may be strained through module mechanical loading to a level that will result in failure in a few hundred to thousands of cycles. Considering the speed at which DML may be applied, this translates into a few hours o testing. To evaluate the equivalence of DML to thermal cycling, parallel tests were conducted with thermal cycling. Preliminary analysis suggests that one +/-1 kPa DML cycle is roughly equivalent to one standard accelerated thermal cycle and approximately 175 of these cycles are equivalent to a 25-year exposure in Golden Colorado for the mechanism of module ribbon fatigue.

14 SOLAR ENERGY↗

Evaluation of Dynamic Mechanical Loading as an Accelerated Test Method for Ribbon Fatigue

Dynamic Mechanical Loading (DML) of photovoltaic modules is explored as a route to quickly fatigue copper interconnect ribbons. Results indicate that most of the interconnect ribbons may be strained through module mechanical loading to a level that will result in failure in a few hundred to thousands of cycles. Considering the speed at which DML may be applied, this translates into a few hours of testing. To evaluate the equivalence of DML to thermal cycling, parallel tests were conducted with thermal cycling. Preliminary analysis suggests that one +/-1 kPa DML cycle is roughly equivalent to one standard accelerated thermal cycle and approximately 175 of these cycles are equivalent to a 25-year exposure in Golden Colorado for the mechanism of module ribbon fatigue.

14 SOLAR ENERGY↗

ACCELERATED TESTING OF NEUTRON-ABSORBING ALLOYS FOR NUCLEAR CRITICALITY CONTROL

The US Department of Energy requires nuclear criticality control materials be used for storage of highly enriched spent nuclear fuel used in government programs and the storage of commercial spent nuclear fuel at the proposed High-Level Nuclear Waste Geological Repository located at Yucca Mountain, Nevada. Two different metallic alloys (Ni-Cr-Mo-Gd and borated stainless steel) have been chosen for this service. An accelerated corrosion test program to validate these materials for this application is described and a performance comparison is made.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ADVANCED X-BAND TEST ACCELERATOR FOR HIGH BRIGHTNESS ELECTRON AND GAMMA RAY BEAMS

In support of Compton scattering gamma-ray source efforts at LLNL, a multi-bunch test stand is being developed to investigate accelerator optimization for future upgrades. This test stand will enable work to explore the science and technology paths required to boost the current 10 Hz monoenergetic gamma-ray (MEGa-Ray) technology to an effective repetition rate exceeding 1 kHz, potentially increasing the average gamma-ray brightness by two orders of magnitude. Multiple bunches must be of exceedingly high quality to produce narrow-bandwidth gamma-rays. Modeling efforts will be presented, along with plans for a multi-bunch test stand at LLNL. The test stand will consist of a 5.5 cell X-band rf photoinjector, single accelerator section, and beam diagnostics. The photoinjector will be a high gradient standing wave structure, featuring a dual feed racetrack coupler. The accelerator will increase the electron energy so that the emittance can be measured using quadrupole scanning techniques. Multi-bunch diagnostics will be developed so that the beam quality can be measured and compared with theory. Design will be presented with modeling simulations, and layout plans.

42 ENGINEERING↗

Advanced X-Band Test Accelerator for High Brightness Electron and Gamma Ray Beams

In support of Compton scattering gamma-ray source efforts at LLNL, a multi-bunch test stand is being developed to investigate accelerator optimization for future upgrades. This test stand will enable work to explore the science and technology paths required to boost the current 10 Hz monoenergetic gamma-ray (MEGa-Ray) technology to an effective repetition rate exceeding 1 kHz, potentially increasing the average gamma-ray brightness by two orders of magnitude. Multiple bunches must be of exceedingly high quality to produce narrow-bandwidth gamma-rays. Modeling efforts will be presented, along with plans for a multi-bunch test stand at LLNL. The test stand will consist of a 5.5 cell X-band rf photoinjector, single accelerator section, and beam diagnostics. The photoinjector will be a high gradient standing wave structure, featuring a dual feed racetrack coupler. The accelerator will increase the electron energy so that the emittance can be measured using quadrupole scanning techniques. Multi-bunch diagnostics will be developed so that the beam quality can be measured and compared with theory. Design will be presented with modeling simulations, and layout plans.

43 PARTICLE ACCELERATORS↗

Accelerated Testing Validation

The DOE Fuel Cell technical team recommended ASTs were performed on 2 different MEAs (designated P5 and HD6) from Ballard Power Systems. These MEAs were also incorporated into stacks and operated in fuel cell bus modules that were either operated in the field (three P5 buses) in Hamburg, or on an Orange county transit authority drive cycle in the laboratory (HD6 bus module). Qualitative agreement was found in the degradation mechanisms and rates observed in the AST and in the field. The HD6 based MEAs exhibited lower voltage degradation rates (due to catalyst corrosion) and slower membrane degradation rates in the field as reflected by their superior performance in the high potential hold and open-circuit potential AST tests. The quantitative correlation of the degradation rates will have to take into account the various stressors in the field including temperature, relative humidity, start/stops and voltage cycles.

08 HYDROGEN↗

Degradation mechanisms and accelerated testing in PEM fuel cells

The durability of PEM fuel cells is a major barrier to the commercialization of these systems for stationary and transportation power applications. Although there has been recent progress in improving durability, further improvements are needed to meet the commercialization targets. Past improvements have largely been made possible because of the fundamental understanding of the underlying degradation mechanisms. By investigating component and cell degradation modes; defining the fundamental degradation mechanisms of components and component interactions new materials can be designed to improve durability. Various factors have been shown to affect the useful life of PEM fuel cells. Other issues arise from component optimization. Operational conditions (such as impurities in either the fuel and oxidant stream), cell environment, temperature (including subfreezing exposure), pressure, current, voltage, etc.; or transient versus continuous operation, including start-up and shutdown procedures, represent other factors that can affect cell performance and durability. The need for Accelerated Stress Tests (ASTs) can be quickly understood given the target lives for fuel cell systems: 5000 hours ({approx} 7 months) for automotive, and 40,000 hrs ({approx} 4.6 years) for stationary systems. Thus testing methods that enable more rapid screening of individual components to determine their durability characteristics, such as off-line environmental testing, are needed for evaluating new component durability in a reasonable turn-around time. This allows proposed improvements in a component to be evaluated rapidly and independently, subsequently allowing rapid advancement in PEM fuel cell durability. These tests are also crucial to developers in order to make sure that they do not sacrifice durability while making improvements in costs (e.g. lower platinum group metal [PGM] loading) and performance (e.g. thinner membrane or a GDL with better water management properties). To achieve a deeper understanding and improve PEM fuel cell durability LANL is conducting research to better define fuel cell component degradation mechanisms and correlate AST measurements to component in 'real-world' situations.

30 DIRECT ENERGY CONVERSION↗

A Revised Capsule Design for the Accelerated Testing of Advanced Reactor Fuels

Testing of fast reactor fuel is currently challenging because of the thermal neutron spectrum of the Advanced Test Reactor (ATR) and the fact that ATR coolant is substantially below typical temperatures found in liquid metal-cooled fast reactors. Despite these issues, since 2003 the Idaho National Laboratory (INL) has successfully tested a variety of metallic, oxide, and nitride fuels for fast reactor applications. There are, however, opportunities to improve the experiments so that the time required to reach a desired burnup can be reduced, and so the sensitivity of the experiments to fabrication tolerances can be minimized. A revised capsule design exploits the use of smaller diameter rodlets to increase power densities and correspondingly reduce the irradiation time required to reach high burnup. Thermal and nuclear analyses indicate that the time to reach 30at% burnup could be reduced from about 12 years to approximately 2-3 years if the fuel diameter is reduced by one-half and to around 1-2 years if the diameter is reduced by one-third. In addition, reducing fuel diameter improves the radial power distribution in the fuel without the use of cadmium shrouding. This observation opens up the possibility of testing advanced reactor fuel systems in Small I locations in the ATR where there is substantial unused capacity. Although not directly tied to a revised capsule design, post-irradiation furnace testing is proposed to provide time-to-failure data that will be helpful in the benchmarking of fuel performance models and in assessing the performance of new fuel designs relative to more standard fast reactor fuel systems. In this paradigm, ATR irradiation experiments will be viewed more as preparation for furnace testing than as experiments that exist in isolation. An added benefit to furnace testing is that uncertainties in temperatures will significantly be reduced relative to non-instrumented capsules in the ATR. The time and cost in developing this experimental capability is expected to be reduced considerably because of the availability of the blister anneal furnace used by the HPRR program. A key issue in the experiment approach is the potential for non-prototypical rodlet dimensions to influence the observed performance of a given fuel design. For example, a qualitative assessment indicates that the effects of fuel-cladding chemical interactions during furnace testing might be more pronounced in reduced diameter rodlets simply because thinner cladding would be more sensitive to a given depth of fission product penetration. In a traditional empirically-driven approach to fuel qualification, any change from prototypical behavior is undesirable because the resulting data cannot easily be assimilated into a statistical correlation. However, in the current approach, systematic variations in fuel diameter provide the opportunity to benchmark fuel performance models over a wider range of parameter space, which in turn is expected to improve understanding and result in better, more physically based models in the long term.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Computational Methods to Characterize Panel Loading Conditions for Accelerated Testing

Panel cracking and degradation due to wind loading are known to have a detrimental effect on power output. Recreating these damaging conditions in a controlled experimental setting requires an understanding of the loads being generated at the panel surface as a function of both wind speed, wind direction, and panel orientation. To better understand these relationships, a computational fluid dynamics (CFD) simulation package was constructed using an open-source Python library for solving partial differential equations with the finite element method. This CFD package allows the simulated wind speed and panel orientation of a multi-panel array to be easily changed and provides the capability to measure the traction forces at discrete points along the sun-facing and ground-facing surface of an interior panel residing in the wake of one or more upstream panels. A parameter exploration was performed in which the panel angle was varied in even increments from -70 deg to 70 deg and the wind speed was varied from 2 to 30 m/s. During post processing, the measured traction along the panel surface was averaged spatially and interpreted as a time-varying signal, where further processing of this signal yielded the root mean square amplitude and a characteristic frequency associated with the loading. This study found that higher wind speeds are generally associated with increased amplitude of loading and that the panel orientation angle can significantly exacerbate or mitigate this loading. These outcomes are presented along with current work on higher-fidelity verification simulations and recommendations for performing accelerated experimental testing.

loading↗