Search NASA⌕ Search

SEARCH · Search NASA

Results for “ambient air”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Long term monitoring of methane in the atmosphere by multiplex gas chromatography

Methane is of interest in the study of the Earth's atmosphere because of its implication in the future global warming of the surface. This warming is produced by the absorption of infrared energy by trace gases. It has been estimated that in the next 40 to 50 years, methane could contribute 20 to 25 pct. as much atmospheric warming as that expected from carbon dioxide increases. Studies to examine sources, sinks, and cycles of methane will require analytical methods capable of continuous unattended measurement with temporal resolution of an hour or less for weeks at a time. Gas chromatography (GC) is one of the most practical methods available to conduct the analysis of air, but limitations in this technique still exist which can be alleviated with multiplex GC (MGC). MGC is a technique where many samples are pseudo-randomly introduced to the chromatograph without regard to the length of time required for an analysis. The resulting data must then be reduced using computational methods such as cross correlation. In the technique reported, a tube packed with silver oxide was used at the inlet of the GC column to create concentration pulses of methane in a sample stream of air. By using only one carrier, i.e., ambient air, an effective and accurate method to monitor the variations in concentration of methane in the atmosphere over long periods of time was developed. Methane in ambient air was monitored for an eight day period and an interesting temporal variability was found. This work has shown the utility of a relatively simple MGC for the analysis of a real environmental sample.

Valentin, Jose R.↗

Data Quality Objectives Supporting Radiological Air Emissions Monitoring for the PNNL-Richland Campus: North Campus Construction (Rev. 3)

Starting in fiscal year 2023, the north area of the PNNL-Richland Campus will undergo development. Initially, infrastructure (water, electrical) improvements will be installed. Later development includes the construction of several new office buildings. The area to be developed currently contains no buildings but does have two existing solar-powered ambient air sampling stations. Under the requirements of Washington State Department of Health Radioactive Air Emissions License -005, the PNNL-Richland Campus must operate and maintain a radiological air monitoring program. This revision documents and evaluates how the new North Campus construction impacts ambient air surveillance stations within the development region. This revision also considers current stack configurations and uses an updated environmental dispersion model and updated meteorological data. The DQO team concluded that one sampling station in the construction area will be relocated and the other remain in place. The evaluations conducted for this DQO also identified a third sampling station outside the development area that is recommended for relocation as a result of updated dispersion modeling. Recommended sites for the relocations are presented. Considerations for sampling in and around a construction zone are also addressed. Additionally, programmatic improvements to the ambient air sampling program were identified in the DQO process.

54 ENVIRONMENTAL SCIENCES↗

Components Refurbishment and Chemical Analysis Facility, Hot Spot 1 SWMU #041 Year 3 Annual Performance Monitoring Report Kennedy Space Center, Florida

This Year 3 Annual Performance Monitoring Report (PMR) presents the operations, maintenance, and monitoring activities for the Hydraulic Containment System (HCS) Interim Measure (IM) at the Components Refurbishment and Chemical Analysis (CRCA) facility located at John F. Kennedy Space Center (KSC), Florida. The primary objective of the HCS is to attain hydraulic control of the dissolved-phase chlorinated volatile organic compound (CVOC) plume, with the secondary objective to reduce concentrations of CVOCs in the high-concentration plume to support transition to monitored natural attenuation (MNA). CRCA has been designated Solid Waste Management Unit 041 under the KSC Resource Conservation and Recovery Act Corrective Action Program. The timeframe for activities documented in this Year 3 PMR extends from September 2021 through October 2022. Baseline sampling activities were completed in June 2019, and full-scale startup of the HCS IM was completed in July-August 2019. The operational runtime of the HCS for the Year 3 reporting period was approximately 91%, with the majority of downtime attributed to system maintenance and repair. This is generally consistent with Year 1 and Year 2 runtimes of 85% and 92%, respectively. To help reduce downtime, an anti-scaling amendment, Redux 390, has been used to reduce scaling and help maintain system design parameters. Over nine million gallons of groundwater were treated during Year 3 of HCS operations, and concentrations of the site’s contaminants of concern (trans-1,2-dichloroethene and vinyl chloride) have been reduced by over 97%. This PMR describes the activities that were performed during Year 3 to operate and monitor the HCS IM, which includes three extraction wells, seven injection wells, and conveyance piping to a modular structure containing the control panel and an air stripper. Influent and effluent sampling results from the air stripper show that the system is operating as designed and is reducing concentrations of contaminants of concern to below detection limits. In addition to HCS operation, this PMR also discusses performance monitoring that has been implemented to assess progress of the HCS IM and overall plume conditions through scheduled groundwater (quarterly and semi-annual) and sub-slab soil gas (quarterly) sampling and analysis. Two ambient air samples were also collected on a quarterly basis in the vicinity of the modular structure and the paved driveway east of the Solvent Reclamation Area during routine operation and maintenance (O&M) activities to ensure safe breathing zone air quality for on-site personnel. All sub-slab soil gas and ambient air sampling conducted during the Year 3 operational period showed results below applicable regulatory air screening limits. Predictions made during the Year 2 groundwater model updates were in close correlation to post Year 3 plume conditions. Therefore, it can be assumed that the projected path remains valid for transition to MNA in one to two years of continuous HCS operation. The contents of this Year 3 PMR were presented during the February 2023 KSC Remediation Team meeting, where Team consensus was reached on several items including continued O&M of the HCS, and continued monitoring of groundwater, ambient air, and sub-slab soil gas. Replacement of MW0019 and VMP04 was also recommended, as well as additional direct-push technology sampling to further delineate the downgradient plume and confirm overall site-wide low-concentration plume boundaries. Sampling for per- and polyfluoroalkyl substances at CRCA is ongoing and will be submitted under separate cover.

K. Alex Murphy↗

Components Refurbishment and Chemical Analysis Facility, Hot Spot 1 Solid Waste Management Unit #041 Year 4 Annual Performance Monitoring Report Kennedy Space Center, Florida

This Year 4 Annual Performance Monitoring Report (PMR) presents the operations, maintenance, and monitoring activities for the Hydraulic Containment System (HCS) Interim Measure (IM) at the Components Refurbishment and Chemical Analysis (CRCA) facility located at John F. Kennedy Space Center (KSC), Florida. The primary objective of the HCS is to attain hydraulic control of the dissolved-phase chlorinated volatile organic compound (CVOC) plume, with the secondary objective to reduce concentrations of CVOCs in the high-concentration plume to support transition to monitored natural attenuation (MNA). CRCA has been designated Solid Waste Management Unit 041 under the KSC Resource Conservation and Recovery Act Corrective Action Program. The timeframe for activities documented in this Year 4 PMR extends from November 2022 through September 2023. Baseline sampling activities were completed in June 2019, and full-scale startup of the HCS IM was completed in July-August 2019. The operational runtime of the HCS for the Year 4 reporting period was approximately 94%, with the majority of downtime attributed to associated groundwater sampling events, maintenance, and Hurricane Nicole. Almost five million gallons of groundwater were treated during Year 4 of HCS operations, and concentrations of the site’s contaminants of concern (trans-1,2-dichloroethene and vinyl chloride) have been reduced by over 99%. This PMR describes the activities that were performed during Year 4 to operate and monitor the HCS IM, which includes three extraction wells, seven injection wells, and conveyance piping to a modular structure containing the control panel and an air stripper. Influent and effluent sampling results from the air stripper show that the system is operating as designed and is reducing concentrations of contaminants of concern to below detection limits. In addition to HCS operation, this PMR also discusses performance monitoring that has been implemented to assess progress of the HCS IM and overall plume conditions through scheduled groundwater (quarterly and semi-annual) and sub-slab soil gas (quarterly) sampling and analysis. Two ambient air samples were also collected on a quarterly basis in the vicinity of the modular structure and the paved driveway east of the Solvent Reclamation Area during routine operation and maintenance (O&M) activities to ensure safe breathing zone air quality for on-site personnel. All sub-slab soil gas and ambient air sampling conducted during the Year 4 operational period showed results below applicable regulatory air screening limits. Predictions made during the Year 2 groundwater model updates were in close correlation to post Year 4 plume conditions. A supplemental DPT study conducted in 2022 and 2023. This study indicated that low-concentration plume conditions, where concentrations exceed State of Florida Groundwater Cleanup Target Levels, expanded westward to Kennedy Parkway North and northward to the vicinity of the railroad tracks. Based on these results, recommendations were made to install 14 wells to monitor the downgradient and boundary conditions of the expanded LCP. The contents of this Year 4 PMR were presented during the November 2023 KSC Remediation Team meeting, where Team consensus was reached on several items including continued O&M of the HCS, and continued monitoring of groundwater, ambient air, and sub-slab soil gas. Sampling for per- and polyfluoroalkyl substances at CRCA is ongoing and will be submitted under separate cover.

K. Alex Murphy↗

Direct Measurement of Small Particle Growth and Aging at the Atmospheric Radiation Measurement Southern Great Plains Observatory Field Campaign Report

Two identical Captive Aerosol Growth and Evolution (CAGE) chambers were operated at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Southern Great Plains (SGP) observatory in the late summer and fall of 2021. The field study was scheduled to begin in spring, 2020, but was delayed because of the pandemic. CAGE chambers are designed to expose particles to an environment that mirrors that of the surroundings with or without a controlled perturbation designed to assess a sensitivity. The analysis here focuses on roughly the last two months of the overall study period during which measurements were almost continuous and when several perturbation experiments were conducted. Though the utility of a dual-chamber system is the ability to measure the influence of a single change on top of ambient conditions, both chambers were initially operated in the same way, with ambient air pulled through the gas exchange channel in both and ammonium sulfate particles injected into both. The similar time-dependent particle growth observed in the chambers for those periods provides confidence in differences observed during the subsequent perturbation experiments. The growth rate of particles in the reference chamber into which only ammonium sulfate particles were injected and for which only ambient air was pulled through were used to describe time-of-day averages. The average growth rate was highest in the evening and in the morning after sunrise and lowest in the late afternoon. The sensitivity of particle growth to secondary aerosol precursor gases was studied by adding them at a controlled rate to the ambient air flow pulled through one of the two chambers. Addition of 5 ppb of α-pinene resulted in an average particle growth rate of 4.4 nm hr -1 , compared with that of just 0.8 nm hr -1 in the reference chamber. The added α-pinene also triggered one new particle formation (NPF) event in the early evening just before sunset and another in the morning just after sunrise. Similarly, addition of 5 ppb of SO 2 to one chamber led to a pair of NPF events and to increased particle growth rate, though unlike the impact of added α-pinene, growth was enhanced only during the daytime when OH concentration is highest. The influence of aerosol liquid water on secondary aerosol formation and particle growth was investigated by injecting ammonium sulfate seed particles into one chamber and potassium sulfate particles into the other. Particles were injected into the two chambers four times over a 1.5-day period. The chamber relative humidity (RH) history during and following each injection was used to determine whether each particle type was crystalline or aqueous. For the case when both particle types remained crystalline throughout the period, they were tracked and for the case when they remained aqueous, the magnitude and time-dependence of the growth of both were almost exactly the same. For the other two cases the ammonium sulfate particles deliquesced upon injection and remained aqueous, while the potassium sulfate particles remained crystalline. For those two cases, the aqueous particles grew substantially faster than did the crystalline particles, providing evidence of the role of aerosol liquid water on secondary aerosol formation and particle growth.

54 ENVIRONMENTAL SCIENCES↗

Energy and Environmental Analyses of a Solar–Gas Turbine Combined Cycle with Inlet Air Cooling

Sensitivity to ambient air temperatures, consuming a large amount of fuel, and wasting a significant amount of heat dumped into the ambient atmosphere are three major challenges facing gas turbine power plants. This study was conducted to simultaneously solve all three aforementioned GT problems using solar energy and introducing a new configuration that consists of solar preheating and inlet-air-cooling systems. In this study, air was preheated at a combustion chamber inlet using parabolic trough collectors. Then, inlet air to the compressor was cooled by these collectors by operating an absorption cooling cycle. At the design point conditions, this novel proposed integration resulted in a 6.87% relative increase in generated power and a 10.53% relative decrement in fuel consumption, achieving a 19.45% relative increment in the plant’s thermal efficiency. This was accompanied by a reduction of 0.026 kg/s, 4.2 kg/s, and 0.278 kg/s in CO 2 , CO, and NOx emissions, respectively. Finally, spider diagrams were employed to assess the impact of the operating parameters on the overall system’s performance and its associated environmental implications.

14 SOLAR ENERGY↗

Smartphone application for visualizing building air leakage

Annually, unwanted air leakage through building envelopes accounts for 4 quads of energy consumption in the United States, which translates to about 10% of total building energy consumption. Locating and sealing leakage sites is crucial fordecreasing building energy consumption. Smartphones are ubiquitous and contain sophisticated cameras and highperformance processors that could be employed to visualize air leakage using the background-oriented schlieren imaging technique, making leak detection cheaper and easier. This technique requires a textured and high-contrast background such as a brick or concrete masonry unit wall, a building air leak that has a temperature difference compared with the ambient air, and an imaging system. This work focuses on using smartphones as the imaging system to visualize air leakages. The paper discusses application development and the results of testing to determine leakage visualization performance as a function of leak temperature. The results show that leaks with a temperature difference greater than 16°C compared with the ambient air temperature were visualized using existing smartphones.

Boudreaux, Philip [ORNL] (ORCID:0000000229564665)↗

NASA's Aerosol Sampling Experiment Summary

In a spacecraft cabin environment, the size range of indoor aerosols is much larger and they persist longer than on Earth because they are not removed by gravitational settling. A previous aerosol experiment in 1991 documented that over 90 of the mass concentration of particles in the NASA Space Shuttle air were between 10 m and 100 m based on measurements with a multi-stage virtual impactor and a nephelometer (Liu et al. 1991). While the now-retired Space Shuttle had short duration missions (less than two weeks), the International Space Station (ISS) has been continually inhabited by astronauts for over a decade. High concentrations of inhalable particles on ISS are potentially responsible for crew complaints of respiratory and eye irritation and comments about 'dusty' air. Air filtration is the current control strategy for airborne particles on the ISS, and filtration modeling, performed for engineering and design validation of the air revitalization system in ISS, predicted that PM requirements would be met. However, aerosol monitoring has never been performed on the ISS to verify PM levels. A flight experiment is in preparation which will provide data on particulate matter in ISS ambient air. Particles will be collected with a thermophoretic sampler as well as with passive samplers which will extend the particle size range of sampling. Samples will be returned to Earth for chemical and microscopic analyses, providing the first aerosol data for ISS ambient air.

Thermophoretic sampler↗

Sampling Indoor Aerosols on the International Space Station

In a spacecraft cabin environment, the size range of indoor aerosols is much larger and they persist longer than on Earth because they are not removed by gravitational settling. A previous aerosol experiment in 1991 documented that over 90 of the mass concentration of particles in the NASA Space Shuttle air were between 10 m and 100 m based on measurements with a multi-stage virtual impactor and a nephelometer (Liu et al. 1991). While the now-retired Space Shuttle had short duration missions (less than two weeks), the International Space Station (ISS) has been continually inhabited by astronauts for over a decade. High concentrations of inhalable particles on ISS are potentially responsible for crew complaints of respiratory and eye irritation and comments about 'dusty' air. Air filtration is the current control strategy for airborne particles on the ISS, and filtration modeling, performed for engineering and design validation of the air revitalization system in ISS, predicted that PM requirements would be met. However, aerosol monitoring has never been performed on the ISS to verify PM levels. A flight experiment is in preparation which will provide data on particulate matter in ISS ambient air. Particles will be collected with a thermophoretic sampler as well as with passive samplers which will extend the particle size range of sampling. Samples will be returned to Earth for chemical and microscopic analyses, providing the first aerosol data for ISS ambient air.

Thermophoretic sampler↗

Air Dispersion Modeling for the Idaho National Laboratory Permit to Construct P-2015.0023 Facility Emission Cap Revision Request

The U.S. Department of Energy Idaho Operations Office (DOE-ID) is seeking to modify permit to construct (PTC) P-2015.0023 issued to U S Dept. of Energy – Idaho National Laboratory (INL) on January 11, 2018 by the Idaho Department of Environmental Quality (DEQ). This PTC allowed the INL to become a synthetic minor source of air pollutants using a facility emission cap (FEC). Air dispersion modeling was performed as part of the permit revision application process to demonstrate that the modifications will comply with the National Ambient Air Quality Standards (NAAQS). This report documents the modeling methodology and complete results for the air dispersion impact analysis and is supplied as an appendix to the permit revision request, Idaho National Laboratory Permit to Construct P-2015.0023 Facility Emission Cap Revision Request (DOE-ID 2020). All CAPs regulated under Section 109 of the Clean Air Act were modeled with the exception of lead (Pb) and ozone which are not required to be modeled by DEQ. Consistent with the original permit application, modeling was not performed for toxic air pollutants (TAPs) as uncontrolled emissions did not exceed screening emission levels for carcinogenic and non-carcinogenic TAPs. Acceptable model design values (concentrations) for each CAP and averaging period were summed with average background concentrations and compared to NAAQS. The results demonstrate the impacts of requested FEC limits for CAPs are less than applicable standards and demonstrate emissions up to FEC limits will not cause a violation of ambient air quality standards.

99 GENERAL AND MISCELLANEOUS↗

multiplex gas chromatography: A novel analytical technique for future planetary studies

Determination of molecular species comprised of the biogenic elements in the atmospheres of planets and moons of the solar system is one the foremost requirements of the exobiologist studying chemical evolution and the origin of life. Multiplex chromatography is a technique where many samples are pseudo-randomly introduced to the chromatograph without regard to elution of preceding components. The resulting data are then reduced using mathematical techniques such as cross correlation or Fourier Transforms. To demonstrate the utility of this technique for future solar system exploration, chemical modulators were developed. Several advantages were realized from this technique in combination with these modulators: improvement in detection limits of several orders of magnitude, improvement in the analysis of complex mixtures by selectively modulating some of the components present in the sample, increase in the number of analyses that can be conducted in a given period of time, and reduction in the amount of expendables needed to run an analysis. In order to apply this technique in a real application, methane in ambient air was monitored continuously over a period of one week. By using ambient air as its own carrier all expendables beyond power were eliminated.

Valentin, J. R.↗

Air Dispersion Modeling for the Idaho National Laboratory Permit to Construct P-2020.0045 Facility Emission Cap Revision Request

The U.S. Department of Energy Idaho Operations Office (DOE-ID) is seeking to modify permit to construct (PTC) P-2020.0045 issued to U S Dept. of Energy – Idaho National Laboratory (INL) on January 29, 2021 by the Idaho Department of Environmental Quality (DEQ). This PTC allowed the INL to become a synthetic minor source of air pollutants using a facility emission cap (FEC). Air dispersion modeling was performed as part of the permit revision application process to demonstrate that the modifications will comply with the National Ambient Air Quality Standards (NAAQS). This report documents the modeling methodology and complete results for the air dispersion impact analysis and is supplied as an appendix to the permit revision request, Idaho National Laboratory Permit to Construct P-2020.0045 (INL 2025). All criteria air pollutants (CAPs) regulated under Section 109 of the Clean Air Act were modeled with the exception of lead (Pb) and ozone which are not required to be modeled by DEQ. Consistent with the original permit application, modeling was not performed for toxic air pollutants (TAPs) as uncontrolled emissions did not exceed screening emission levels for carcinogenic and non-carcinogenic TAPs. Acceptable model design values (concentrations) for each CAP and averaging period were summed with average background concentrations and compared to NAAQS. The results demonstrate the impacts of requested FEC limits for CAPs are less than applicable standards and demonstrate emissions up to FEC limits will not cause a violation of ambient air quality standards.

54 ENVIRONMENTAL SCIENCES↗

Conceptual Design of the Transformational Challenge Reactor

The Transformational Challenge Reactor is a 3-MW(thermal) helium-cooled experimental nuclear reactor designed using an additive manufacturing–informed agile design process. This design process leverages rapid prototyping and advanced materials from emerging additive manufacturing technologies, key characteristics that enable rapid design maturation. The resulting core design incorporates a blend of advanced reactor technologies into an intermediate-spectrum microreactor, including conventionally manufactured tristructural isotropic (TRISO) fuel particles in an advanced manufactured SiC fuel element and a solid yttrium hydride moderator encapsulated in steel. Matured during the design effort, these technologies are incorporated with additively manufactured steel support and fluidic structures to form a 75-cm-outer-diameter cylindrical active core region. Below and above the active core region are axial SiC reflectors, which are housed inside the reactor pressure vessel. The reactor is controlled with an annular shroud actuated external to the pressure vessel in the gap between the pressure vessel and a steel radial reflector. A safety rod is at the center of the core to shut down the reactor when necessary. Helium pressurized at 5 MPa is forced into the pressure vessel below the core and around the core to the top plenum before it is forced down through the axial reflectors and the active core region. The primary pressurized helium loop is operated up to 500°C and includes the pressure vessel, the circulator, and the hot side of a helium-to-air heat exchanger. The secondary loop rejects all heat from the primary loop to ambient air through a heat exchanger. A vented temporary confinement building contains the entire primary loop, with penetrations for a stack, cooling, and the secondary ambient air loop. Finally, this is the first advanced nuclear microreactor designed using additive manufacturing technologies, demonstrating their applicability in an accelerated advanced design process.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

EMP, Attachment 2: Data Management Plan

This Data Management Plan (DMP) is an attachment to the Pacific Northwest National Laboratory Environmental Radiological Air Monitoring Plan (EMP). PNNL is a U.S. Department of Energy Office of Science national laboratory. Radioactive effluent monitoring and environmental surveillance for PNNL operations in Washington State are the responsibility of the PNNL Environmental Protection and Regulatory Programs division and are conducted by the Environmental Radiation Task staff. This DMP describes the data management processes for PNNL radioactive air emissions (stack) monitoring and environmental radiological ambient air surveillance activities.

40 CFR 61 Subpart H↗

EMP, Attachment 1: Sampling and Analysis Plan (Rev.1)

This Sampling and Analysis Plan (SAP) is written for the Environmental Radiation Task activities related to radioactive air emissions (stack) monitoring and environmental radiological ambient air surveillance of Pacific Northwest National Laboratory (PNNL) operations at the PNNL-Richland campus and PNNL-Sequim campus. PNNL is a U.S. Department of Energy Office of Science laboratory in Richland, Washington. This plan is an attachment to PNNL’s Environmental Radiological Air Monitoring Plan (EMP) (PNNL-20919) and addresses a discrete, vital subject area that is subject to revision independent of the main text of the EMP document. This SAP provides the requirements for planning sampling events and the requirements imposed on the services provided by the analytical laboratory to the PNNL Environmental Radiation Task.

40 CFR 61 Subpart H↗

Investigating dry room compatibility of sulfide solid-state electrolytes for scalable manufacturing

All-solid-state batteries (ASSBs) are viewed as promising next-generation energy storage devices, due to their enhanced safety by replacing organic liquid electrolytes with non-flammable solid-state electrolytes (SSEs). The high ionic conductivity and low Young's modulus of sulfide SSEs make them suitable candidates for commercial ASSBs. Nevertheless, sulfide SSEs are generally reported to be unstable in ambient air. Moreover, instead of gloveboxes used for laboratory scale studies, large scale production of batteries is usually conducted in dry rooms. Thus, this study aims to elucidate the chemical evolution of a sulfide electrolyte, Li 6 PS 5 Cl (LPSCl), during air exposure and to evaluate its dry room compatibility. When LPSCl is exposed to ambient air, hydrolysis, hydration, and carbonate formation can occur. Moreover, hydrolysis can lead to irreversible sulfur loss and therefore LPSCl cannot be fully recovered in the subsequent heat treatment. During heat treatment, exposed LPSCl undergoes dehydration, decomposition of carbonate species, and reformation of the LPSCl phase. Lastly, LPSCl was found to exhibit good stability in a dry room environment and was subject to only minor conductivity loss due to carbonate formation. The dry room exposed LPSCl sample was tested in a LiNi 0.8 Co 0.1 Mn 0.1 O 2 |LiIn half-cell, exhibiting no significant loss of electrochemical performance compared with the pristine LPSCl, proving it to be compatible with dry room manufacturing processes.

36 MATERIALS SCIENCE↗

Development of a solar-powered residential air conditioner: Screening analysis

Screening analysis aimed at the definition of an optimum configuration of a Rankine cycle solar-powered air conditioner designed for residential application were conducted. Initial studies revealed that system performance and cost were extremely sensitive to condensing temperature and to the type of condenser used in the system. Consequently, the screening analyses were concerned with the generation of parametric design data for different condenser approaches; i. e., (1) an ambient air condenser, (2) a humidified ambient air condenser (3) an evaporative condenser, and (4) a water condenser (with a cooling tower). All systems feature a high performance turbocompressor and a single refrigerant (R-11) for the power and refrigeration loops. Data were obtained by computerized methods developed to permit system characterization over a broad range of operating and design conditions. The criteria used for comparison of the candidate system approaches were (1) overall system COP (refrigeration effect/solar heat input), (2) auxiliary electric power for fans and pumps, and (3) system installed cost or cost to the user.

Source record↗

Method and apparatus for checking fire detectors

A fire detector checking method and device are disclosed for nondestructively verifying the operation of installed fire detectors of the type which operate on the principle of detecting the rate of temperature rise of the ambient air to sound an alarm and/or which sound an alarm when the temperature of the ambient air reaches a preset level. The fire alarm checker uses the principle of effecting a controlled simulated alarm condition to ascertain wheather or not the detector will respond. The checker comprises a hand-held instrument employing a controlled heat source, e.g., an electric lamp having a variable input, for heating at a controlled rate an enclosed mass of air in a first compartment, which air mass is then disposed about the fire detector to be checked. A second compartment of the device houses an electronic circuit to sense and adjust the temperature level and heating rate of the heat source.

Clawson, G. T.↗