Search NASA⌕ Search

SEARCH · Search NASA

Results for “astrophysics instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Stellar Radial Velocities in the Old Open Cluster M67 (NGC 2682). II. The Spectroscopic Binary Population

We present and analyze 120 spectroscopic binary and triple cluster members of the old (4 Gyr) open cluster M67 (NGC 2682). As a cornerstone of stellar astrophysics, M67 is a key cluster in the WIYN Open Cluster Study (WOCS); radial-velocity (RV) observations of M67 are ongoing and extend back over 45 yr, incorporating data from seven different telescopes, and allowing us to detect binaries with orbital periods ≲10{sup 4} days. Our sample contains 1296 stars (604 cluster members) with magnitudes of 10 ≤ V ≤ 16.5 (about 1.3–0.7 M {sub ⊙}), from the giants down to ∼4 mag below the main-sequence turnoff, and extends in radius to 30′ (7.4 pc at a distance of 850 pc, or ∼7 core radii). This paper focuses primarily on the main-sequence binaries, but orbital solutions are also presented for red giants, yellow giants, and sub-subgiants. Out to our period detection limit and within our magnitude and spatial domain, we find a global main-sequence incompleteness-corrected binary fraction of 34% ± 3%, which rises to 70% ± 17% in the cluster center. We derive a tidal circularization period of P{sub circ}=11.0{sub −1.0}{sup +1.1} days. We also analyze the incompleteness-corrected distributions of binary orbital elements and masses. The period distribution rises toward longer periods. The eccentricity distribution, beyond P {sub circ}, is consistent with a uniform distribution. The mass-ratio distribution is also consistent with a uniform distribution. Overall, these M67 binaries are closely consistent with similar binaries in the galactic field, as well as with the old (7 Gyr) open cluster NGC 188. WOCS. 83.

47 OTHER INSTRUMENTATION↗

The Stars Kepler Missed: Investigating the Kepler Target Selection Function Using Gaia DR2

The Kepler Mission revolutionized exoplanet science and stellar astrophysics by obtaining highly precise photometry of over 200,000 stars over 4 yr. A critical piece of information to exploit Kepler data is its selection function, since all targets had to be selected from a sample of half a million stars on the Kepler CCDs using limited information. Here we use Gaia DR2 to reconstruct the Kepler selection function and explore possible biases with respect to evolutionary state, stellar multiplicity, and kinematics. We find that the Kepler target selection is nearly complete for stars brighter than Kp < 14 mag and was effective at selecting main-sequence stars, with the fraction of observed stars decreasing from 95% to 60% between 14 < Kp < 16 mag. We find that the observed fraction for subgiant stars is only 10% lower, confirming that a significant number of subgiants selected for observation were believed to be main-sequence stars. Conversely we find a strong selection bias against low-luminosity red giant stars (R ≈ 3–5R {sub ⊙}, T {sub eff} ≈ 5500 K), dropping from 90% at Kp = 14 mag to below 30% at Kp = 16 mag, confirming that the target selection was efficient at distinguishing dwarfs from giants. We compare the Gaia Re-normalized Unit Weight Error (RUWE) values of the observed and nonobserved main-sequence stars and find a difference in elevated (>1.2) RUWE values at ∼σ significance, suggesting that the Kepler target selection shows some bias against either close or wide binaries. We furthermore use the Gaia proper motions to show that the Kepler selection function was unbiased with respect to kinematics.

47 OTHER INSTRUMENTATION↗

Commercially Fabricated Antenna-Coupled Transition Edge Sensor Bolometer Detectors for Next-Generation Cosmic Microwave Background Polarimetry Experiment

We report on the development of commercially fabricated multi-chronic antenna-coupled transition edge sensor (TES) bolometer arrays for cosmic microwave background (CMB) polarimetry experiments. The orders of magnitude increase in detector count for next-generation CMB experiments require a new approach in detector wafer production to increase fabrication throughput. Here, we describe collaborative efforts with a commercial superconductor electronics fabrication facility (SeeQC, Inc.) to fabricate antenna-coupled TES bolometer detectors. We have successfully fabricated an operational dual-polarization, dichroic sinuous antenna-coupled TES detector array on a 150-mm-diameter wafer. The fabricated detector arrays have average yield of 95% and excellent uniformity across the wafer. Both RF characteristics and TES bolometer properties are suitable for CMB observations. We successfully fabricated different types of TES bolometers optimized for frequency multiplexing readout, time-domain multiplexing readout, and microwave SQUID multiplexing readout. We also demonstrated high production throughput. We discuss the motivation, design considerations, fabrication processes, test results, and how industrial detector fabrication could be a path to fabricate hundreds of detector wafers for future CMB polarimetry experiments.

47 OTHER INSTRUMENTATION↗

Characterization of Transition Edge Sensors for the Simons Observatory

The Simons Observatory is building both large (6 m) and small (0.5 m) aperture telescopes in the Atacama Desert in Chile to observe the cosmic microwave background CMB radiation with unprecedented sensitivity. Simons Observatory telescopes in total will use over 60,000 transition edge sensor (TES) detectors spanning center frequencies between 27 and 285 GHz and operating near 100 mK. TES devices have been fabricated for the Simons Observatory by NIST, Berkeley, and HYPRES/SeeQC corporation. Iterations of these devices have been tested cryogenically in order to inform the fabrication of further devices, which will culminate in the final TES designs to be deployed in the field. The detailed design specifications have been independently iterated at each fabrication facility for particular detector frequencies. We present test results for prototype devices, with emphasis on NIST high frequency detectors. A dilution refrigerator was used to achieve the required temperatures. Measurements were taken both with 4-lead resistance measurements and with a time-domain Superconducting Quantum Interference Device (SQUID) multiplexer system. The SQUID readout measurements include analysis of current versus voltage (IV) curves at various temperatures, square wave bias step measurements, and detector noise measurements. Lastly, normal resistance, superconducting critical temperature, saturation power, thermal and natural time constants, and thermal properties of the devices are extracted from these measurements.

47 OTHER INSTRUMENTATION↗

End-to-End Modeling of the TDM Readout System for CMB-S4

The CMB-S4 experiment is developing next-generation ground-based microwave telescopes to observe the cosmic microwave background with unprecedented sensitivity. This will require an order of magnitude increase in the 100-mK detector count, which, in turn, increases the demands on the readout system. The CMB-S4 readout will use time-division multiplexing (TDM), taking advantage of faster switches and amplifiers in order to achieve an increased multiplexing factor. To facilitate the design of the new readout system, we have developed a model that predicts the bandwidth and noise performance of this circuitry and its interconnections. This is then used to set requirements on individual components in order to meet the performance necessary for the full system. Here, we present an overview of this model and compare the model results to the performance of both legacy and prototype readout hardware.

47 OTHER INSTRUMENTATION↗

Bayesian Model for HOPE Mass Spectrometers on Van Allen Probes

Space instruments rely heavily on modeling to predict and understand the instrument response, enabling a determination of the capabilities and resolution. The Bayesian approach provides a framework to incorporate prior knowledge and propagate uncertainty to predict the instrument response. We present an empirical Bayes model for the end-to-end performance of the Helium, Oxygen, Proton, and Electron mass spectrometers aboard the Van Allen Probes mission. In this model, we use a combination of external modeling, laboratory calibration, and expert opinion to construct the time-of-flight spectra and demonstrate good agreement with on-orbit data. The empirical Bayes model is applied to explore doubly charged ions and carbon, nitrogen, oxygen discrimination during the Van Allen Probes mission.

47 OTHER INSTRUMENTATION↗

Using the Gerchberg-Saxton algorithm to reconstruct nonmodulated pyramid wavefront sensor measurements

Adaptive optics (AO) is a technique to improve the resolution of ground-based telescopes by correcting, in real-time, optical aberrations due to atmospheric turbulence and the telescope itself. With the rise of Giant Segmented Mirror Telescopes (GSMT), AO is needed more than ever to reach the full potential of these future observatories. One of the main performance drivers of an AO system is the wavefront sensing operation, consisting of measuring the shape of the above mentioned optical aberrations. Aims. The non-modulated pyramid wavefront sensor (nPWFS) is a wavefront sensor with high sensitivity, allowing the limits of AO systems to be pushed. The high sensitivity comes at the expense of its dynamic range, which makes it a highly non-linear sensor. We propose here a novel way to invert nPWFS signals by using the principle of reciprocity of light propagation and the Gerchberg-Saxton (GS) algorithm. We test the performance of this reconstructor in two steps: the technique is first implemented in simulations, where some of its basic properties are studied. Then, the GS reconstructor is tested on the Santa Cruz Extreme Adaptive optics Laboratory (SEAL) testbed located at the University of California Santa Cruz. This new way to invert the nPWFS measurements allows us to drastically increase the dynamic range of the reconstruction for the nPWFS, pushing the dynamics close to a modulated PWFS. The reconstructor is an iterative algorithm requiring heavy computational burden, which could be an issue for real-time purposes in its current implementation. However, this new reconstructor could still be helpful in the case of many wavefront control operations. In conclusion, this reconstruction technique has also been successfully tested on the Santa Cruz Extreme AO Laboratory (SEAL) bench where it is now used as the standard way to invert nPWFS signal.

47 OTHER INSTRUMENTATION↗

The DAMIC-M Low Background Chamber

The DArk Matter In CCDs at Modane (DAMIC-M) experiment isdesigned to search for light dark matter (m$_{χ}$ < 10 GeV/c$^{2}$)at the Laboratoire Souterrain de Modane (LSM) in France. DAMIC-Mwill use skipper charge-coupled devices (CCDs) as a kg-scale activedetector target. Its single-electron resolution will enable eV-scaleenergy thresholds and thus world-leading sensitivity to a range ofhidden sector dark matter candidates. A DAMIC-M prototype, the LowBackground Chamber (LBC), has been taking data at LSM since2022. The LBC provides a low-background environment, which has beenused to characterize skipper CCDs, study dark current, and measureradiopurity of materials planned for DAMIC-M. It also allows testingof various subsystems like readout electronics, data acquisitionsoftware, and slow control. This paper describes the technicaldesign and performance of the LBC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The pathfinder X-Ray axion telescope for the International Axion Observatory (IAXO) and axion searches at the CERN Axion Solar Telescope (CAST)

The axion, a hypothetical pseudo-scalar particle proposed by Peccei and Quinn to resolve the strong CP problem in quantum chromodynamics, remains one of the most compelling dark matter candidates. Axions and Axion-Like Particles (ALPs) are characterized by a broad and largely unconstrained parameter space in mass and coupling strength, motivating extensive experimental searches. The International Axion Observatory (IAXO) is a next-generation axion helioscope designed to achieve over an order of magnitude improvement in sensitivity to the axion-photon coupling constant gaγ relative to previous experiments such as the CERN Axion Solar Telescope (CAST). IAXO will employ large-scale superconducting magnets, precision x-ray optics, and ultra-low-background detectors to search for solar axions produced primarily via the Primakoff effect. This work presents the design and performance of the IAXO pathfinder x-ray optic, a technological demonstrator that validated the optical concepts for IAXO through axion searches at CAST. Comprehensive ray-tracing simulations and experimental measurements were conducted to assess the optic's effective area, detection efficiency, and background suppression capabilities. Deployed at CAST in conjunction with Micromegas and GridPix detectors, the Pathfinder demonstrated record-setting sensitivity to both gaγ and the axion-electron coupling gae, establishing the most stringent laboratory constraints on solar axions to date. These results confirm the viability of the IAXO optical design and detector concept, providing a critical technological benchmark that informs the ongoing development of the BabyIAXO and full-scale IAXO telescopes.

47 OTHER INSTRUMENTATION↗

Astrometry in two-photon interferometry using an Earth rotation fringe scan

Optical interferometers may not require a phase-stable optical link between the stations if instead sources of quantum-mechanically entangled pairs could be provided to them, enabling long baselines. We developed a new variation of this idea, proposing that photons from two different astronomical sources could be interfered at two decoupled stations. Interference products can then be calculated in post-processing or requiring only a slow, classical connection between stations. In this work, we investigated practical feasibility of this approach. We developed a Bayesian analysis method for the earth rotation fringe scanning technique and showed that in the limit of high signal-to-noise ratio it reproduced the results from a simple Fisher matrix analysis. Here we identify candidate stair pairs in the northern hemisphere, where this technique could be applied. With two telescopes with an effective collecting area of ~ 2 m 2 , we could detect fringing and measure the astrometric separation of the sources at ~100 μas precision in a few hours of observations, in agreement with previous estimates.

47 OTHER INSTRUMENTATION↗

High-count rate effects in event processing for XRISM/ Resolve X-ray microcalorimeter: I. Ground test

The spectroscopic performance of an X-ray microcalorimeter is compromised at high count rates. We utilize the Resolve X-ray microcalorimeter onboard the XRISM satellite to examine the effects observed during high-count rate measurements and propose modeling approaches to mitigate them. We specifically address the following instrumental effects that impact performance: CPU limit, pile-up, and untriggered electrical cross-talk. Experimental data at high count rates were acquired during ground testing using the flight model instrument and a calibration X-ray source. In the experiment, data processing not limited by the performance of the onboard CPU was run in parallel, which cannot be done in orbit. This makes it possible to access the data degradation caused by limited CPU performance. We use these data to develop models that allow for a more accurate estimation of the aforementioned effects. To illustrate the application of these models in observation planning, we present a simulated observation of GX 13+1. Understanding and addressing these issues is crucial to enhancing the reliability and precision of X-ray spectroscopy in situations characterized by elevated count rates.

47 OTHER INSTRUMENTATION↗

Line emission mapper microcalorimeter spectrometer

The line emission mapper (LEM) is a probe-class mission concept that is designed to detect x-ray emission lines from hot ionized gas (T > 10 6 K) that will enable us to test galaxy evolution theories. It will permit us to study the effects of stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. The key to being able to study the hot gases that are otherwise invisible to current imaging x-ray spectrometers is that the energy resolution is sufficient to use cosmological redshift to separate extragalactic source lines from foreground Milky Way emission. LEM incorporates a large-format microcalorimeter array instrument called the LEM microcalorimeter spectrometer (LMS) with a light-weight x-ray optic with 10” half power diameter angular resolution. The LMS microcalorimeter array has pixels with 15" pixel pitch over a 33' field of view (FOV) optimized for the 0.3 to 2 keV energy band. The central 7' region of the array has an energy resolution of 1.3 eV at 1 keV and the rest of the FOV has 2.5 eV energy resolution at 1 keV. The array will be read out with state-of-the-art time-division multiplexing. We present an overview of the LMS instrument, including details of the entire detection chain, the focal plane assembly, as well as the cooling system and overall mechanical and thermal design. For each of the key technologies, we discuss the current technology readiness level and the plan to advance them to be ready for flight. We also describe the current system design and our estimate for the mass, power, and data rate of the instrument. The design details presented concentrate primarily on the unique aspects of the LMS design compared with prior missions and confirm that the type of microcalorimeter instrument needed for LEM is not only feasible but also technically mature.

47 OTHER INSTRUMENTATION↗

The XLZD Design Book: towards the next-generation liquid xenon observatory for dark matter and neutrino physics

This report describes the experimental strategy and technologies for XLZD, the next-generation xenon observatory sensitive to dark matter and neutrino physics. In the baseline design, the detector will have an active liquid xenon target of 60 tonnes, which could be increased to 80 tonnes if the market conditions for xenon are favorable. It is based on the mature liquid xenon time projection chamber technology used in current-generation experiments, LZ and XENONnT. The report discusses the baseline design and opportunities for further optimization of the individual detector components. The experiment envisaged here has the capability to explore parameter space for Weakly Interacting Massive Particle (WIMP) dark matter down to the neutrino fog, with a 3σ evidence potential for WIMP-nucleon cross sections as low as 3 x 10 –49 cm 2 (at 40 GeV/c 2 WIMP mass). The observatory will also have leading sensitivity to a wide range of alternative dark matter models. It is projected to have a 3σ observation potential of neutrinoless double beta decay of 136 Xe at a half-life of up to 5.7 x 10 27 years. Additionally, it is sensitive to astrophysical neutrinos from the sun and galactic supernovae.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Dark Energy Spectrographic Instrument (DESI) Optical Fiber System

The specific research of the DESI project is to study in detail the expansion history of the Universe over the past 10 billion years. In order to do this, the project designed, fabricated, tested and commissioned the DESI instrument which has been deployed at the Mayall Telescope at the Kitt Peak National Observatory near Tucson, Arizona. The DESI project was conducted by approximately 30 US and foreign national laboratories. The complete instrument includes a prime focus corrector assembly, a focal plane with 5,000 optical fibers whose position can be set by robotic positioners, and ten spectrographs. Each spectrograph can accommodate the light from 500 fibers and include three color channels that are illuminated by a common collimator mirror and other planar transfer optics. In order for this entire system to work, optical fibers are required to connect each positioner to the spectrographs. Our CRADA with Durham University in the UK provided the 10 crucial fiber cables required to connect the DESI focal plane to the 10 spectrographs. The key major goals of this CRADA were achieved. Survey planning was another key component to the Durham contribution. Drs. Frenk, Baugh, Cole, Edge, Lacey, Li, Lucey, Massey, Metcalfe, Norberg and Shanks were all important contributors to the working groups to which they were assigned. Their work to implement emission lines and QSO in lightcone mocks, mocks for non-standard cosmologies/modified gravity, optimization of completeness of BGS in crowded regions and extended source photometry have been vital in the early planning for targets during commissioning. The major role in the project involved Dr. Ray Sharples and his team. They provided a significant portion of the design, fabrication and testing of the optical fiber system. In particular, they were responsible for the design, production of engineering drawings, component procurements, and fabrication of the 10 DESI Science fiber cables. Working in close collaboration with Dr. Claire Poppett, they also designed and fabricated the slit assemblies, the specialized termination of the groups of 500 fibers which plug into the spectrographs.

47 OTHER INSTRUMENTATION↗

Software on Mars [Slides]

This community outreach presentation for high school students discusses instrumentation and software developed by Los Alamos National Laboratory for NASA's Perseverance rover that landed on Mars February 2021.

47 OTHER INSTRUMENTATION↗