Listening for Neutrinos with Quantum Acoustics

Many low-threshold superconducting detectors rely on athermal phonon sensing, in which meV-scale phonons from a DM scatter are sensed via their ability to break Cooper pairs in superconducting films. While detectors based on such pairbreaking sensors are highly advantageous and scalable, their sensor threshold is ultimately limited by the energy needed to break a Cooper pair, 2Δ. We present a novel detector architecture for single phonon detection at the O(10μeV) scale, the qubit-coupled hBAR, that does not share this limitation. This architecture, composed of a superconducting qubit piezoelectrically coupled to a high-overtone bulk acoustic resonator, was originally developed in the context of the quantum acoustics community and has a sensor threshold ultimately limited by thermal noise. Such ultra-low-threshold detectors have a wide range of fundamental science applications, including reactor monitoring via neutrinos.

Baxter, Daniel Stephen [Fermilab] (ORCID:000000030↗

Cluster Dynamics Simulations of Intra-Granular Fission Gas Bubble Size and Pressure Evolution in UO 2

Fission gases such as xenon (Xe) play a critical role in determining the behavior and response of nuclear fuel. Given that Xe has little solubility in UO 2 , it accumulates and forms bubbles, which significantly impact fuel performance. Intra- and inter-granular bubble nucleation and growth can lead to fuel swelling, and once bubbles interconnect at grain boundaries, fission gas can be released into the plenum. At low temperatures, limited uranium vacancy mobility can restrict swelling, therefore causing the bubbles to become highly pressurized. Consequently, this can induce micro-cracking, promote fission gas release (increasing the likelihood of cladding failure), and even lead to fuel pulverization under accident conditions such as a loss of coolant accident. As bubble evolution is strongly influenced by local temperature and fission rate, markedly different behavior occurs across the radial profile of the fuel pellet. Capturing the mechanisms that underpin bubble evolution is therefore important to predict these behaviors in the fuel. Previous models describing important mechanisms informed by lower length scale simulations have been developed under the NEAMS program. These can describe the evolution of a single bubble type (i.e., single value for radius and pressure) at each position in the pellet, for instance using the Centipede cluster dynamic code. However, in reality, a full distribution in bubble sizes and pressures exists within the microstructure at a given position in the pellet. To address this the cluster dynamics code Xolotl, which can predict Xe and vacancy phase space (i.e., bubble distributions) for intra-granular bubbles, has been used before. Prior work benchmarked the Xolotl code against the Centipede cluster dynamics code to ensure compatibility and to verify that mobile defect properties are adequately transferred between the two codes, along with some physics improvements. In this work, we go further by introducing a physics-based set of improvements that will allow us to accurately predict bubble size distributions and internal bubble pressures under representative UO 2 irradiation conditions. The improvements include (i) coupling bubble-defect reaction energies to a virial equation of state (EOS), (ii) including a bubble surface tension contribution, (iii) incorporating radiation-induced re-solution of Xe and vacancies, (iv) enabling pressure-driven dislocation loop punching through an effective emission of interstitial clusters informed by interstitial loop energetics, (v) accounting for radiation induced athermal diffusion of Xe, and (vi) implementing a Booth-type grain boundary sink representation for all mobile defects and defect clusters. After these modifications, we observe good agreement of Xolotl fission gas bubble size and concentration predictions with legacy experimental measurements. Additionally, it allows the distribution of Xe bubble pressures and radius to also be predicted and compared to data produced through the Advanced Fuels Campaign (AFC) program. Here, we have done this by running simulations under conditions similar to the AFC post-irradiation examination (PIE) samples irradiated at North Anna 2 light water reactor (LWR). Our results shows excellent agreement with these experimental measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Outer planets mission television subsystem optics study

An optics study was performed to establish a candidate optical system design for the proposed NASA Mariner Jupiter/Saturn 77 mission. The study was performed over the 6-month period from January through June 1972. The candidate optical system contains both a wide angle (A) and a narrow angle (B) lens. An additional feature is a transfer mirror mechanism that allows image transfer from the B lens to the vidicon initially used for the A lens. This feature adds an operational redundancy to the optical system in allowing for narrow angle viewing if the narrow angle vidicon were to fail. In this failure mode, photography in the wide angle mode would be discontinued. The structure of the candidate system consists mainly of aluminum with substructures of Invar for athermalization. The total optical system weighs (excluding vidicons) approximately 30 pounds and has overall dimensions of 26.6 by 19.5 by 12.3 inches.

Source record↗

Metallographic study of metallic fragment of lunar surface material

A high precision investigation of a metallic fragment from the lunar material returned by the Soviet Luna 16 automatic station revealed three characteristic temperature intervals with different kinetics of solid solution decomposition. The following were found in the structure of the iron-nickel-cobalt alloy: (1) delta-phase and alpha-ferrite of diffusional, displacement origin in the grain boundary and acicular forms; and (2) martensite of isothermal and athermal nature, acicular, lamellar, massive, and dendritic. The diversity of the shapes of structural constituents is associated with the effect on their formation of elastic distortions and various mechanisms of deformation relaxation processes.

Mints, R. I.↗

Flow stress model in metal cutting

A model for the plastic deformation that occurs in metal cutting, based on dislocation mechanics, is presented. The model explains the fundamental deformation structure that develops during machining and is based on the well known Cottrell-Stokes Law, wherein the flow stress is partitioned into two parts; an athermal part which occurs in the shear fronts (or shear bands); and a thermal part which occurs in the lamella regions. The deformation envokes the presence of a cellular dislocation distribution which always exists in the material ahead of the shear process. This 'alien' dislocation distribution either exists in the metal prior to cutting or is produced by the compressive stress field which operates in front of the shear process. The magnitude of the flow stress and direction of the shear are shown to be correlated to the stacking fault energy of the metal being cut. The model is tested with respect to energy consumption rates and found to be consistent with observed values.

Black, J. T.↗

Latch fittings for the scientific instruments on the space telescope

Latch fittings which kinematically mount the replaceable scientific instruments onto the Space Telescope must maintain precise alignment and thermal stability for on-orbit observations. Design features which are needed to meet stringent criteria include the use of ceramic isolators for thermal and electrical insulation, materials with different coefficients of thermal expansion for athermalization, precision manufacturing procedures, and extremely tight tolerances. A specific latch fitting to be discussed is a ball-and-socket design. In addition, testing, crew aids, and problems will be covered.

Dozier, J. D.↗

Near-infrared mapping spectrometer optical subsystem development and testing

The Near-Infrared Mapping Spectrometer (NIMS) is one of the four remote-sensing science instruments of the Galileo Orbiter scientific payload. The NIMS scientific objectives require operating the detector and optical subsystem at cryogenic temperatures. The necessity of assembling, aligning, and testing the optics at room temperature and meeting design specifications at the cryogenic operating temperature (130 K) presented a set of challenging technical problems. A systematic approach to the development of athermalized mounts and supporting structures for optical components is described. A technique utilizing the visible spectral range and supplementary ray-trace information for alignment of an infrared instrument is presented. The optical subsystem point-spread function and spatial and spectral resolution were determined at room temperature using selected spectral and spatial targets. Based on thermal-distortion analyses of the structure and mounts, compensators were selected, implemented, and verified at cryogenic temperatures. The selection of the compensator and the overall system performance were verified in a thermal vacuum chamber. Various external and internal calibration targets were used.

Macenka, S. A.↗

Optomechanical design considerations in the development of the DDLT laser diode collimator

A laser diode collimator objective was developed in support of the Direct Detection Transceiver program. Close attention to optomechanical design issues including athermalization, alignment, selection of materials, mounting of elements, and hermetic sealing of the assembly was necessary to insure that the desired optical performance was maintained in space deployment.

Kampe, Thomas U.↗

A modified pump laser system to pump the titanium sapphire laser

As a result of the wide tunability of the titanium sapphire laser NASA has sited it to be used to perform differential absorption lidar (DIAL) measurements of H2O vapor in the upper and lower troposphere. The titanium sapphire laser can provide a spectrally narrow (0.3 to 1.0 pm), high energy (0.5 to 1.0 J) output at 727, 762, and 940 nm which are needed in the DIAL experiments. This laser performance can be obtained by addressing the line-narrowing issues in a master oscillator and the high energy requirement in a fundamental mode oscillator. By injection seeding, the single frequency property of the master oscillator can produce a line narrow high energy power oscillator. A breadboard model of the titanium sapphire laser that will ultimately be used in NASA lidar atmospheric sensing experiment is being designed. The task was to identify and solve any problem that would arise in the actual laser system. One such problem was encountered in the pump laser system. The pump laser that is designed to pump both the master oscillator and power oscillator is a Nd:YLF laser. Nd:YLF exhibits a number of properties which renders this material an attractive option to be used in the laser system. The Nd:YLF crystal is effectively athermal; it produces essentially no thermal lensing and thermally induced birefringence is generally insignificant in comparison to the material birefringence resulting from the uniaxial crystal structure. However, in application repeated fracturing of these laser rods was experience. Because Nd:YLF rods are not commercially available at the sizes needed for this application a modified pump laser system to replace the Nd:YLF laser rod was designed to include the more durable Nd:YAG laser rods. In this design, compensation for the thermal lensing effect that is introduced because of the Nd:YAG laser rods is included.

Petway, Larry B.↗

Wide-Angle, Reflective Strip-Imaging Camera

Proposed camera images thin, striplike portion of field of view of 180 degrees wide. Hemispherical concave reflector forms image onto optical fibers, which transfers it to strip of photodetectors or spectrograph. Advantages include little geometric distortion, achromatism, and ease of athermalization. Uses include surveillance of clouds, coarse mapping of terrain, measurements of bidirectional reflectance distribution functions of aerosols, imaging spectrometry, oceanography, and exploration of planets.

Vaughan, Arthur H.↗

Deformation behavior of a Ni-30Al-20Fe-0.05Zr intermetallic alloy in the temperature range 300 to 1300 K

The deformation properties of an extruded Ni-30Al-20Fe-0.05Zr (at. pct) alloy in the temperature range 300-1300 K were investigated under initial tensile strain rates that varied between 10 exp -6 and 10 exp -3/sec and in constant load compression creep between 1073 and 1300 K. Three deformation regimes were observed: region I, occurring between 400 and 673 K, which consisted of an athermal regime of less than 0.3 percent tensile ductility; region II, between 673 and 1073, where exponential creep was dominant; and region III, between 1073 and 1300 K, where a significant improvement in tensile ductility was observed.

Raj, S. V.↗

SiC lightweight telescopes for advanced space applications. II - Structures technology

A critical technology area for lightweight SiC-based telescope systems is the structural integrity and thermal stability over spaceborne environmental launch and thermal operating conditions. Note, it is highly desirable to have an inherently athermal design of both SiC mirrors and structure. SSG has developed an 8 inch diameter SiC telescope system for brassboard level optical and thermal testing. The brassboard telescope has demonstrated less than 0.2 waves P-V in the visible wavefront change over +50 C to -200 C temperature range. SSG has also fabricated a SiC truss structural assembly and successfully qualified this hardware at environmental levels greater than 3 times higher than normal Delta, Titan, and ARIES launch loads. SSG is currently developing two SiC telescopes; an 20 cm diameter off-axis 3 mirror re-imaging and a 60 cm aperture on-axis 3 mirror re-imager. Both hardware developments will be tested to flight level environmental, optical, and thermal specifications.

Anapol, Michael I.↗

Comparison of Stress Relief Procedures for Cryogenic Aluminum Mirrors

The Infrared Multi-Object Spectrograph (IRMOS) is a facility instrument for the Kitt Peak National Observatory Mayall Telescope (3.8 meter) and an engineering prototype for a potential design for the Next Generation Space Telescope/Multi-Object Spectrograph. IRMOS is a low-to mid-resolution (R = lambda/delta-lambda = 300-3800), near-IR (0.8-2.5 micron) spectrograph which produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arcmin field of view using a commercial MEMS multimirror array device. The instrument operating temperature is 80 K and the design is athermal --- the optical bench and mirrors are machined from aluminum 6061-T651. In spite of its baseline mechanical stress relief, aluminum 6061-T651 harbors some residual stress, which, unless relieved during fabrication, may relieve and distort mirror figure to unacceptable levels at the operating temperature. Other cryogenic instruments using aluminum mirrors for both ground-based and space IR astronomy have employed a variety of heat treatment formulae, with mixed results. We present the results of a test program designed to empirically determine the best stress relief procedure for the IRMOS mirrors. Identical test mirrors with spherical and flat optical prescriptions are processed with five different heat treatment formulae from the literature and compared to samples with out any additional processing. After figuring via diamond turning, the mirrors are tested for figure error and radius of curvature at room temperature and at 80 K for several thermal cycles. The heat treatment procedure for the mirrors that yielded the least and most repeatable change in figure error and radius is applied to the IRMOS mirror blanks. We correlate the results of our optical testing with heat treatment and metallographic data.

Ohl, Raymond G.↗

Lattice Boltzmann Method for 3-D Flows with Curved Boundary

In this work, we investigate two issues that are important to computational efficiency and reliability in fluid dynamics applications of the lattice, Boltzmann equation (LBE): (1) Computational stability and accuracy of different lattice Boltzmann models and (2) the treatment of the boundary conditions on curved solid boundaries and their 3-D implementations. Three athermal 3-D LBE models (D3QI5, D3Ql9, and D3Q27) are studied and compared in terms of efficiency, accuracy, and robustness. The boundary treatment recently developed by Filippova and Hanel and Met et al. in 2-D is extended to and implemented for 3-D. The convergence, stability, and computational efficiency of the 3-D LBE models with the boundary treatment for curved boundaries were tested in simulations of four 3-D flows: (1) Fully developed flows in a square duct, (2) flow in a 3-D lid-driven cavity, (3) fully developed flows in a circular pipe, and (4) a uniform flow over a sphere. We found that while the fifteen-velocity 3-D (D3Ql5) model is more prone to numerical instability and the D3Q27 is more computationally intensive, the 63Q19 model provides a balance between computational reliability and efficiency. Through numerical simulations, we demonstrated that the boundary treatment for 3-D arbitrary curved geometry has second-order accuracy and possesses satisfactory stability characteristics.

Mei, Renwei↗

Optical Testing of Diamond Machined, Aspheric Mirrors for Groundbased, Near-IR Astronomy

The Infrared Multi-Object Spectrometer (IRMOS) is a facility-class instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8-2.5 micron) spectrometer and operates at approximately 80 K. The 6061-T651 aluminum bench and mirrors constitute an athermal design. The instrument produces simultaneous spectra at low- to mid-resolving power (R=lambda/delta lambda= 300-3000) of approximately 100 objects in its 2.8 x 2.0 arcmin field. We describe ambient and cryogenic optical testing of the IRMOS mirrors across a broad range in spatial frequency (figure error, mid-frequency error, and microroughness). The mirrors include three rotationally symmetric, off-axis conic sections, one off-axis biconic, and several flat fold mirrors. The symmetric mirrors include convex and concave prolate and oblate ellipsoids. They range in aperture from 94x86 mm to 286x269 mm and in f-number from 0.9 to 2.4. The biconic mirror is concave and has a 94x76 mm aperture, R(sub x)=377 mm, k(sub x)=0.0778, R(sub y)=407 mm, and k(sub y)=0.1265 and is decentered by -2 mm in X and 227 mm in Y. All of the mirrors have an aspect ratio of approximately 6:1. The surface error fabrication tolerances are less than 10 nm RMS microroughness, 'best effort' for mid-frequency error, and less than 63.3 nm RMS figure error. Ambient temperature (approximately 293 K) testing is performed for each of the three surface error regimes, and figure testing is also performed at approximately 80 K. Operation of the ADE Phaseshift MicroXAM white light interferometer (micro-roughness) and the Bauer Model 200 profilometer (mid-frequency error) is described. Both the sag and conic values of the aspheric mirrors make these tests challenging. Figure testing is performed using a Zygo GPI interferometer, custom computer generated holograms (CGH), and optomechanical alignment fiducials. Cryogenic CGH null testing is discussed in detail. We discuss complications such as the change in prescription with temperature and thermal gradients. Correction for the effect of the dewar window is also covered. We discuss the error budget for the optical test and alignment procedure. Data reduction is accomplished using commercial optical design and data analysis software packages. Results from CGH testing at cryogenic temperatures are encouraging thus far.

Chambers, V. John↗

Design and Construction of a Field Capable Snapshot Hyperspectral Imaging Spectrometer

The computed-tomography imaging spectrometer (CTIS) is a device which captures the spatial and spectral content of a rapidly evolving same in a single image frame. The most recent CTIS design is optically all reflective and uses as its dispersive device a stated the-art reflective computer generated hologram (CGH). This project focuses on the instrument's transition from laboratory to field. This design will enable the CTIS to withstand a harsh desert environment. The system is modeled in optical design software using a tolerance analysis. The tolerances guide the design of the athermal mount and component parts. The parts are assembled into a working mount shell where the performance of the mounts is tested for thermal integrity. An interferometric analysis of the reflective CGH is also performed.

Arik, Glenda H.↗

Monolithic prestressed ceramic devices and method for making same

Monolithic, internally asymmetrically stress biased electrically active ceramic devices and a method for making same is disclosed. The first step in the method of the present invention is to fabricate a ceramic element having first and second opposing surfaces. Next, only the first surface is chemically reduced by heat treatment in a reducing atmosphere. This produces a concave shaped, internally asymmetrically stress biased ceramic element and an electrically conducting, chemically reduced layer on the first surface which serves as one of the electrodes of the device. Another electrode can be deposited on the second surface to complete the device. In another embodiment of the present invention two dome shaped ceramic devices can be placed together to form a completed clamshell structure or an accordion type structure. In a further embodiment, the clamshell or accordion type structures can be placed on top of one another. In another embodiment, a pair of dome shaped ceramic devices having opposing temperature characteristics can be placed on top of each other to produce an athermalized ceramic device.

Haertling, Gene H.↗