Search NASA⌕ Search

SEARCH · Search NASA

Results for “atom interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Generation of gamma radiation by a subterawatt ultrashort laser pulse: optimisation of preplasma and pulse duration

We report an experimental and numerical study of the acceleration of electrons in a plasma interacting with a subterawatt laser pulse (intensity of ∼3 × 10{sup 18} W cm{sup −2} at a pulse duration of 50 fs). A preplasma layer on the surface of a molybdenum target is formed by an additional laser pulse with a duration of 8 ns and an intensity of ∼2 × 10{sup 12} W cm{sup −2}. It is shown that an increase in the laser pulse duration to 1700 fs at a constant energy (and a proportional decrease in intensity) leads to an increase in the yield of bremsstrahlung γ-radiation by more than an order of magnitude when the nanosecond pulse is ahead of the femtosecond one by 15 − 25 ns. Interferometry data and results of diagnostics of optical and γ-radiation of a plasma demonstrate that the collisional ionisation of atoms by electrons oscillating in the field of such a laser pulse plays an essential role in the formation of electron density profile. The sensitivity of the described effect to the level of amplified spontaneous emission is determined, despite the nanosecond pulse impact. Numerical simulations show that at a large pulse duration, the acceleration of electrons is stipulated by the beaking of plasma waves excited during stimulated Raman scattering of laser radiation. (paper)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Complete spectroscopy in the attosecond regime

Harnessing light waveforms at attosecond time scales provides information of the structure and dynamics of matter on it's natural time scales. For this reason attosecond metrology has been at the forefront of the optical sciences for more than a decade, and it represents the latest time-domain frontier of the quantum world. Attosecond light pulses are commonly generated using higher-order harmonic generation (HHG) , a process capable of generating XUV coherent pulses. In addition to generate attosecond pulses, HHG can be used to study the structure and dynamics of atoms and molecules by analyzing the spectral content of the XUV pulses. This approach is known as HHG spectroscopy and it provides a coherent, time-dependent approach to study structure and dynamics in the quantum world. In this proposal we will generate harmonics from two optical foci produced by a system of a two-dimensional spatial light modulator (SLM) and a lens. In the far eld the train of attosecond pulses will interfere creating harmonic-dependent fringes. The position of such fringes is a direct measurement of the relative phase between the two foci and they also carry information about the quantum state of the target atom or molecule. Therefore, by measuring the amplitude and relative phase of the emitted harmonics we will have access to both, the amplitude and phase of the dipole moments of the studied target. Because the two beams are completely indistinguishable from each other up to a few millimeters from the focus, both driving pulses share the exact beam path. So far we have measured a jitter of 700 zeptoseconds with a 12.5 attosecond resolution in the delay control of the two foci. These two time scales represent some of the best time controls ever achieved to date.

74 ATOMIC AND MOLECULAR PHYSICS↗

Shock compression of crystalline TeO 2 to the high-pressure fluid regime: Insights from ab initio molecular dynamics simulations

The shock response of fully-dense and porous crystalline tellurium dioxide (TeO 2 ⁠) to the high-pressure and high-temperature fluid regime was investigated within the framework of density functional theory with Mermin’s generalization to finite temperatures. The principal and porous shock Hugoniot curves were predicted from canonical ab initio molecular dynamics (AIMD) simulations, with the phase space sampled along isotherms up to 80 000 K, for densities ranging from ρ = 3 to 17 g/cm 3 . The polymorphs investigated are α-TeO 2 paratellurite (⁠P4 1 2 1 2), TeO 2 cotunnite (⁠Pnma⁠), and TeO 2 post-cotunnite (⁠P2 1 /m⁠). Based on the discontinuity found in the calculated U s – u p slope of TeO 2 post-cotunnite at a shock velocity of U s ≃ 8.35km/s and a particle velocity of u p ≃ 3.64 km/s, the shock melting temperature and pressure are predicted to be ≃ 6500 K and ≃ 170 GPa. Results from the AIMD simulations are in line with the static compression data of TeO 2 paratellurite and cotunnite, and with the recent shock Hugoniot data for single-crystal α- TeO 2 for pressures up to 85 GPa, obtained using the inclined-mirror method and the velocity interferometer system for any reflector combined with powder gun and two-stage light-gas gun.

74 ATOMIC AND MOLECULAR PHYSICS↗

Roadmap on Atomtronics: State of the art and perspective

Atomtronics deals with matter-wave circuits of ultracold atoms manipulated through magnetic or laser-generated guides with different shapes and intensities. In this way, new types of quantum networks can be constructed in which coherent fluids are controlled with the know-how developed in the atomic and molecular physics community. In particular, quantum devices with enhanced precision, control, and flexibility of their operating conditions can be accessed. Concomitantly, new quantum simulators and emulators harnessing on the coherent current flows can also be developed. Here, the authors survey the landscape of atomtronics-enabled quantum technology and draw a roadmap for the field in the near future. The authors review some of the latest progress achieved in matter-wave circuits' design and atom-chips. Atomtronic networks are deployed as promising platforms for probing many-body physics with a new angle and a new twist. The latter can be done at the level of both equilibrium and nonequilibrium situations. Numerous relevant problems in mesoscopic physics, such as persistent currents and quantum transport in circuits of fermionic or bosonic atoms, are studied through a new lens. The authors summarize some of the atomtronics quantum devices and sensors. Finally, the authors discuss alkali-earth and Rydberg atoms as potential platforms for the realization of atomtronic circuits with special features.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiloop and multiaxis atomtronic Sagnac interferometry

We report the experimental realization of a large-area and multiaxis atomtronic interferometer in an optical waveguide for rotation sensing. A large enclosed area is achieved through multiloop operation in a guided-atom interferometer using Bose-Einstein condensates. We demonstrate a three-loop interferometer with a total interrogation time of ∼ 0.4 s and an enclosed area of 8.7 mm 2 —the largest reported in a fully guided or one-dimensional setup. High-contrast interference fringes are observed for up to five Sagnac orbits in a smaller loop-area configuration. Our approach enables interleaved rotation measurements about multiple arbitrary axes within the same experimental setup. We present results for area-enclosing interferometers in both horizontal and vertical planes, demonstrating that the interferometer contrast remains comparable across orthogonal orientations of the enclosed area vectors.

74 ATOMIC AND MOLECULAR PHYSICS↗

Quantum beats in two-color photoionization to the spin-orbit split continuum of Ar

We report a study of the quantum beats in two-color photoionization of argon. An attosecond extreme ultraviolet pulse train prepares an electronic wave packet of definite odd parity, with total angular momentum J = 1, targeting the states between 14.0 and 14.5 eV from the ground state. Two-photon ionization of this wave packet with a tunable infrared probe pulse makes the constituent states interfere in both continuum channels, corresponding to the core angular momenta j c = 1/2 and 3/2, respectively. We analyze photoelectron spectrograms as a function of the time delay of the probe pulse and identify oscillations due to several pairs of states through Fourier decomposition. We observe phase differences between the corresponding beat signals in the two spin-orbit split continua. Comparison of theoretical simulations with the experimental measurements allows us to interpret the amplitudes and phases of ionization signals. Furthermore, we express the observed phase differences in terms of the off-diagonal elements of the short-range scattering matrix and the dipole matrix elements to the continuum eigenchannels.

74 ATOMIC AND MOLECULAR PHYSICS↗

Uniform, Large-Area, Highly Ordered Peptoid Monolayer and Bilayer Films for Sensing Applications

The production of atomically defined, uniform, large-area 2D materials remains as a challenge in materials chemistry. Many methods to produce 2D nanomaterials suffer from limited lateral film dimensions, lack of film uniformity, or limited chemical diversity. These issues have hindered the application of these materials to sensing applications, which require large-area uniform films to achieve reliable and consistent signals. Furthermore, the development of a 2D material system that is biocompatible and readily chemically tunable has been a fundamental challenge. Here, we report a simple, robust method for the production of large-area, uniform, and highly tunable monolayer and bilayer films, from sequence-defined peptoid polymers, and their application as highly selective molecular recognition elements in sensor production. Monolayers and bilayer films were produced on the centimeter scale using Langmuir-Blodgett methods and exhibited a high degree of uniformity and ordering as evidenced by atomic force microscopy, electron diffraction, and grazing incidence X-ray scattering. We further demonstrated the utility of these films in sensing applications by employing the biolayer interferometry technique to detect the specific binding of the pathogen derived proteins, shiga toxin and anthrax protective antigen, to peptoid-coated sensors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanometer flat blazed x-ray gratings using ion beam figure correction

With the development of nanometer accuracy stitching interferometry, ion beam figuring (IBF) of x-ray mirrors can now be achieved with unprecedented performance. However, the process of producing x-ray diffraction gratings on these surfaces may degrade the figure quality due to process errors introduced during the ruling of the grating grooves. To address this challenge, we have investigated the post-production correction of gratings using IBF, where stitching interferometry is used to provide in-process feedback. A concern with ion beam correction in this case is that ions will induce enough surface mobility of atoms to cause smoothing of the grating structure and degradation of diffraction efficiency. In this study we found however that it is possible to achieve a nanometer-level planarity of the global grating surface with IBF, while preserving the grating structure. The preservation was so good, that we could not detect a change in the diffraction efficiency after ion beam correction. This is of major importance in achieving ultra-high spectral resolution, and the preservation of brightness for coherent x-ray beams.

36 MATERIALS SCIENCE↗

Squeezing Noise in Microscopy with Quantum Light

Quantum-enhanced microscopes capable of probing classically inaccessible material properties have drawn increasing interest, but most proof-of-principle quantum microscopes have not surpassed classical limits. Here, we discuss the promise and obstacles associated with the use of quantum light with reduced noise (‘squeezed’ light) for quantum-enhanced atomic force microscopy, bioimaging, magneto-optical measurements, and Raman spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TiO 2 Nanocoatings with Controllable Crystal Type and Nanoscale Topography on Zirconia Implants to Accelerate Bone Formation

In dentistry, zirconia implants have emerged as a promising alternative for replacing missing teeth due to their superior aesthetic performance and chemical stability. To improve the osseointegration of zirconia implants, modifying their surface with hierarchical micro/nanotopography and bioactive chemical composition are two effective ways. In this work, a microscale topography was prepared on a zirconia surface using hydrofluoric acid etching, and then a 50 nm TiO 2 nanocoating was deposited via atomic layer deposition (ALD). Subsequently, an annealing treatment was used to transform the TiO 2 from amorphous to anatase and simultaneously generate nanoscale topography. Various investigations into the coating surface morphology, topography, wettability, and chemical composition were carried out using scanning electron microscopy, white light interferometry, contact‐angle measurement, X‐ray diffraction, and X‐ray photoelectron spectroscopy. In addition, in vitro cytocompatibility and osteogenic potential performance of the coatings were evaluated by human bone marrow mesenchymal stem cells (hBMSCs), and in vivo osseointegration performance was assessed in a rat femoral condyle model. Moreover, the possible mechanism was also investigated. The deposition of TiO 2 film with/without annealing treatment did not alter the microscale roughness of the zirconia surface, whereas the nanotopography changed significantly after annealing. The in vitro studies revealed that the anatase TiO 2 coating with regular wavelike nanostructure could promote the adhesion and proliferation of osteoblasts and further improve the osteogenic potential in vitro and osseointegration in vivo. These positive effects may be caused by nanoscale topography via the canonical Wnt/ β ‐catenin pathway. The results suggest that using ALD in combination with annealing treatment to fabricate a nanotopographic TiO 2 coating is a promising way to improve the osteogenic properties of zirconia implants.

Li, Nan (ORCID:0000000255156737)↗

Microscopic changes governing melting anisotropy: Real-time nanosecond x-ray diffraction

To understand the microscopic origins governing melting anisotropy, in-situ x-ray diffraction (XRD) measurements were obtained in aluminum single crystals shocked along $\langle$100$\rangle$ and $\langle$110$\rangle$ to stresses below and above the melting threshold for each orientation. XRD results and analysis for the two orientations showed significant differences in the microstructure prior to the melting threshold stresses, demonstrating the key role of deformation induced microstructure – in addition to temperature and pressure – on the melting transition. As a result, our findings make a strong case for reconsidering theoretical approaches to melting, specifically for dislocation mediated melting, in shock compressed solids.

crystal melting↗

Integrative Quantitative-Phase and Airy Light-Sheet Imaging

Light-sheet microscopy enables considerable speed and phototoxicity gains, while quantitative-phase imaging confers label-free organelle recognition and metabolic information that are inaccessible by conventional methods. We report the fusion of these two modalities onto a standard inverted microscope that retains compatibility with microfluidics. We describe the utilization of an accelerating Airy-beam light-sheet yielding identical imaging areas with interferometry, and an application in unmasking the effects of cellular noise on metabolic compartmentalization.

Biological sciences, Biological techniques, Micros↗

Improved Spatial Resolution Achieved by Chromatic Intensity Interferometry

Interferometers are widely used in imaging technologies to achieve enhanced spatial resolution, but require that the incoming photons be indistinguishable. In previous work, we built and analyzed color erasure detectors which expand the scope of intensity interferometry to accommodate sources of different colors. Here we demonstrate experimentally how color erasure detectors can achieve improved spatial resolution in an imaging task, well beyond the diffraction limit. Utilizing two 10.9 mm-aperture telescopes and a 0.8 m baseline, we measure the distance between a 1063.6 nm source and a 1064.4 nm source separated by 4.2 mm at a distance of 1.43 km, which surpasses the diffraction limit of a single telescope by about 40 times. Moreover, chromatic intensity interferometry allows us to recover the phase of the Fourier transform of the imaged objects – a quantity that is, in the presence of modest noise, inaccessible to conventional intensity interferometry.

74 ATOMIC AND MOLECULAR PHYSICS↗

High-Power Clock Laser Spectrally Tailored for High-Fidelity Quantum State Engineering

Highly frequency-stable lasers are ubiquitous tools for optical-frequency metrology, precision interferometry, and quantum information science. While making a universally applicable laser is unrealistic, spectral noise can be tailored for specific applications. Here we report a high-power 698-nm clock laser with a maximum output of 4W and minimized frequency noise up to a few kHz Fourier frequency, together with long-term instability of 3.5 × 10 −17 at one to thousands of seconds. The laser-frequency noise is precisely characterized with atom-based spectral analysis that employs a pulse sequence designed to suppress sensitivity to intensity noise. This method provides universally applicable tunability of the spectral response and analysis of quantum sensors over a wide frequency range. With the optimized laser system characterized by this technique, we achieve an average single-qubit Clifford gate fidelity of up to 𝐹$^2_1$ = 0.999⁢64⁢(3) when simultaneously driving 3000 optical qubits with a homogeneous Rabi frequency ranging from 10 Hz to 1 kHz. This result represents the highest single optical-qubit-gate fidelity for a large number of atoms.

atomic gases↗

A Synoptic VLBI Technique for Localizing Nonrepeating Fast Radio Bursts with CHIME/FRB

We demonstrate the blind interferometric detection and localization of two fast radio bursts (FRBs) with subarcminute precision on the 400 m baseline between the Canadian Hydrogen Intensity Mapping Experiment (CHIME) and the CHIME Pathfinder. In the same spirit as Very Long Baseline Interferometry (VLBI), the telescopes were synchronized to separate clocks, and the channelized voltage (herein referred to as baseband) data were saved to a disk with correlation performed offline. The simultaneous wide field of view and high sensitivity required for blind FRB searches implies a high data rate—6.5 terabits per second (Tb/s) for CHIME and 0.8 Tb s{sup −1} for the Pathfinder. Since such high data rates cannot be continuously saved, we buffer data from both telescopes locally in memory for ≈40 s, and write to the disk upon receipt of a low-latency trigger from the CHIME Fast Radio Burst Instrument (CHIME/FRB). The ≈200 deg{sup 2} field of view of the two telescopes allows us to use in-field calibrators to synchronize the two telescopes without needing either separate calibrator observations or an atomic timing standard. In addition to our FRB observations, we analyze bright single pulses from the pulsars B0329+54 and B0355+54 to characterize systematic localization errors. Our results demonstrate the successful implementation of key software, triggering, and calibration challenges for CHIME/FRB Outriggers: cylindrical VLBI outrigger telescopes which, along with the CHIME telescope, will localize thousands of single FRB events with sufficient precision to unambiguously associate a host galaxy with each burst.

47 OTHER INSTRUMENTATION↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Fast quantum interferometry at the nanometer and attosecond scales with energy-entangled photons

In classical optical interferometry, loss and background complicate achieving fast nanometer-resolution measurements with illumination at low light levels. Conversely, quantum two-photon interference is unaffected by loss and background, but nanometer-scale resolution is physically difficult to realize. As a solution, we enhance two-photon interference with highly nondegenerate energy entanglement featuring photon frequencies separated by 177 THz. We observe measurement resolution at the nanometer (attosecond) scale with only O(10 4 ) photon pairs, despite the presence of background and loss. Our nondestructive thickness measurement of a metallic thin film agrees with atomic force microscopy, which often achieves better resolution via destructive means. With contactless, nondestructive measurements in seconds or faster, our instrument enables metrological studies in optically challenging contexts where background, loss, or photosensitivity are factors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗