Search NASA⌕ Search

SEARCH · Search NASA

Results for “atomic mass”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Exploring the mass surface near the rare-earth abundance peak via precision mass measurements at JYFLTRAP

The JYFLTRAP double Penning trap at the Ion Guide Isotope Separator On-Line facility has been used to measure the atomic masses of 13 neutron-rich rare-earth isotopes. Eight of the nuclides, 161 Pm, 163 Sm, 164,165 Eu, 167 Gd, and 165,167,168 Tb, were measured for the first time. The systematics of the mass surface has been studied via one- and two-neutron separation energies as well as neutron pairing-gap and shell-gap energies. The proton-neutron pairing strength has also been investigated. Furthermore, the impact of the new mass values on the astrophysical rapid neutron capture process has been studied. The calculated abundance distribution results in a better agreement with the solar abundance pattern near the top of the rare-earth abundance peak at around A≈165.

74 ATOMIC AND MOLECULAR PHYSICS↗

Understanding the Quadrupole Mass Filter and Testing a High-Resolution QMS RGA for ITER

A common type of residual gas analyzer is the quadrupole mass spectrometer. One of the main components within this instrument is a mass filter known as the quadrupole. It is responsible for the selective throughput of the ionized gas particles - by ascending mass number - prior to ion impacts on the analyzer (or detector) surface from which the ion current signal is generated for processing. However, the quadrupole is not fully described in relation to the electric field characteristics and the function as an ion mass separator. This paper describes the basic origins of the electrical design, the intricate assembly criteria, and performance of the quadrupole within the spectrometer. A specialized quadrupole mass spectrometer is part of a configuration for a diagnostic gas analyzer system planned for ITER, a fusion research machine. It has a verified capability, essential as a diagnostic criterion for this reactor project, to successfully deconvolute the mass signals of Helium-4 and deuterium (reactor fuel exhaust gases, separated by only 0.026 atomic mass units), down to a relative three-percent concentration of the former gas. The associated preliminary testing, performed at the Oak Ridge National Laboratory, is also addressed. Finally, one of the key parameters used to express gas concentration, the relative sensitivity factor, will be explained, including an evaluation of dependency on other variables.

Marcus, Chris [ORNL] (ORCID:0000000190139636)↗

PIA update: Correlation analyses of mass spectra

The PIA instrument aboard the Giotto spacecraft (a time of flight spectrometer) has been presented elsewhere. The mass spectra used in this analysis were decoded and mass numbers assigned according to the presence of carbon and silver, using the global values for these elements in their spectral absence. The results presented here were obtained using a frequency of occurrence based on analysis which correlated how often mass numbers appear in the mass spectra and which mass numbers tend to occur together in the same spectra; no amplitude information is utilized. The data are presented as plots of mass vs coincident mass for different subsets of the PIA data set, with both axes having units of atomic mass. Frequency contours are plotted at approximately five percent contour intervals, relative to the maximum AMU occurrence in that plot. The plots presented are symmetrical about the matrix diagonal, i.e., every mass is coincident with itself in a given spectra.

Mason, L. W.↗

Astrophysical significance of the isomer 119⁢𝑚 Ag demonstrated through a direct mass measurement

Here, the abundance of elements heavier than iron produced via the astrophysical rapid-neutron-capture process depends sensitively on the atomic mass of the involved nuclei as well as the behavior of a few special types of nuclear isomers called “astromers.” High-precision mass measurements of 119 Cd and 119 Ag and their respective isomeric states have been performed with the phase-imaging ion cyclotron resonance (PI-ICR) method with a precision of 𝛿⁢𝑚/𝑚 ≈ 10 −8 using the Canadian Penning trap. The ground-state mass excess, as well as the excitation energy, agrees with recent Penning trap measurements from JYFLTRAP. Network calculations using these new measurements have revealed that, contrary to previous expectations, 119⁢𝑚 Ag behaves as an astromer, which significantly affects the population of 119 Ag .

Rivero, F. [University of Notre Dame, IN (United S↗

High-precision Penning trap mass measurements of neutron-rich chlorine isotopes at the 𝑁 = 28 shell closure

Although it is known that the N = 28 spherical shell closure erodes, the strength of the closure with decreasing proton number Z < 20 is an open question in nuclear structure. Here, in this region of interest, high-precision mass measurements of neutron-rich 43-45 Cl isotopes were performed at the Low Energy Beam and Ion Trap (LEBIT) when coupled to the National Superconducting Cyclotron Lab. The resulting mass excesses (MEs) are ME(⁴³Cl) = -24114.4(1.7) keV, ME(⁴⁴Cl) = -20450.8(10.6) keV, and ME(⁴⁵Cl) = -18240.1(3.7) keV, and improve the uncertainty of these masses by up to a factor of ∼40 compared to the previous values reported in the 2020 Atomic Mass Evaluation. Comparison to ab initio calculations using the Valence-Space In-Medium Similarity Renormalization Group (VS-IMSRG) shows good agreement up to and including the closure.

Erington, H. [Michigan State Univ., East Lansing, ↗

Miniature Focusing Time-of-Flight Mass Spectrometer

An improved miniature time-of-flight mass spectrometer has been developed in a continuing effort to minimize the sizes, weights, power demands, and costs of mass spectrometers for such diverse applications as measurement of concentrations of pollutants in the atmosphere, detecting poisonous gases in mines, and analyzing exhaust gases of automobiles. Advantageous characteristics of this mass spectrometer include the following: It is simple and rugged. Relative to prior mass spectrometers, it is inexpensive to build. There is no need for precise alignment of its components. Its mass range is practically unlimited Relative to prior mass spectrometers, it offers high sensitivity (ability to measure relative concentrations as small as parts per billion). Its resolution is one dalton (one atomic mass unit). An entire mass spectrum is recorded in a single pulse. (In a conventional mass spectrometer, a spectrum is recorded mass by mass.) The data-acquisition process takes only seconds. It is a lightweight, low-power, portable instrument. Although time-of-flight mass spectrometers (TOF-MSs) have been miniaturized previously, their performances have not been completely satisfactory. An inherent adverse effect of miniaturization of a TOF-MS is a loss of resolution caused by reduction of the length of its flight tube. In the present improved TOF-MS, the adverse effect of shortening the flight tube is counteracted by (1) using charged-particle optics to constrain ion trajectories to the flight-tube axis while (2) reducing ion velocities to increase ion flight times. In the present improved TOF-MS, a stream of gas is generated by use of a hypodermic needle. The stream of gas is crossed by an energy-selected, pulsed beam of electrons (see Figure 1). The ions generated by impingement of the electrons on the gas atoms are then focused by three cylindrical electrostatic lenses, which constitute a segmented flight tube. After traveling along the flight tube, the ions enter a charged-particle detector. The output of the detector is fed to a counting circuit to obtain data on the counting rate as a function of time. Inasmuch as time of flight is directly proportional to the ion mass, a plot of the counting rate versus time of flight is equivalent to a mass spectrum (see Figure 2).

Kanik, Isik↗

Influence of isoelectronic mass modulation on phonon decay and transport in layered pnictogen-carbon systems

This study systematically investigates the structural, electronic, and thermal transport properties of layered pnictogen–carbon (Pn 2 C 2 ; Pn = P, As, Sb, Bi) monolayers, revealing a profound influence of isoelectronic mass modulation on phonon dynamics and thermal conductivity. Through first-principles calculations and lattice dynamics analysis, we demonstrate that increasing the atomic mass of pnictogens leads to elongated Pn-C bonds, weakened interatomic interactions, and enhanced phonon-phonon scattering, resulting in a dramatic reduction in lattice thermal conductivity (κ). Specifically, κ decreases exponentially from 65.6 W/m-K in P 2 C 2 to an ultralow 0.37 W/m-K in Bi 2 C 2 , driven by suppressed acoustic-optical phonon gaps Δ$^{Γ}_{A-0}$, increased anharmonicity, and reduced phonon lifetimes and group velocities. The transition from semiconducting to metallic behavior in heavier pnictogen-based systems further enhances phonon-electron scattering, contributing to thermal conductivity suppression. Structural analysis highlights the strengthening of out-of-plane C—C bonds and the contraction of C—Pn—C bond angles, which disrupt in-plane phonon transport. Further, these findings establish a design framework for engineering ultralow-κ materials through chemical substitution and structural tuning, offering significant potential for thermoelectric and thermal management applications. This work provides fundamental insights into phonon decay mechanisms and thermal transport in 2D materials, paving the way for advanced phononic and energy-efficient devices.

2D materials↗

Low-Pressure, Field-Ionizing Mass Spectrometer

A small mass spectrometer utilizing a miniature field ionization source is now undergoing development. It is designed for use in a variety of applications in which there are requirements for a lightweight, low-power-consumption instrument that can analyze the masses of a wide variety of molecules and ions. The device can operate without need for a high-vacuum, carrier-gas feed radioactive ionizing source, or thermal ionizer. This mass spectrometer can operate either in the natural vacuum of outer space or on Earth at any ambient pressure below 50 torr (below about 6.7 kPa) - a partial vacuum that can easily be reached by use of a small sampling pump. This mass spectrometer also has a large dynamic range - from singly charged small gas ions to deoxyribonucleic acid (DNA) fragments larger than 104 atomic mass units - with sensitivity adequate for detecting some molecules and ions at relative abundances of less than one part per billion. This instrument (see figure) includes a field ionizer integrated with a rotating-field mass spectrometer (RFMS). The field ionizer effects ionization of a type characterized as "soft" in the art because it does not fragment molecules or initiate avalanche arcing. What makes the "soft" ionization mode possible is that the distance between the ionizing electrodes is less than mean free path for ions at the maximum anticipated operating pressure, so that the ionizer always operates on the non-breakdown side of the applicable Paschen curve (a standard plot of breakdown potential on the ordinate and pressure electrode separation on the abscissa). The field ionizer in this instrument is fabricated by micromachining a submicron-thick membrane out of an electrically nonconductive substrate, coating the membrane on both sides to form electrodes, then micromachining small holes through the electrodes and membrane. Because of the submicron electrode separation, even a potential of only 1 V applied between the electrodes gives rise to an electric field with a strength of in excess of a megavolt per meter strong enough to ionize any gas molecules passing through the holes. An accelerator grid and an electrostatic deflector focus the ions from the field ionizer into the rotating-field cell of the RFMS. The potentials applied to the electrodes of the cell to generate the rotating electric field typically range from 1 to 13 V. The ions travel in well-defined helices within this cell, after which they are collected in a Faraday cup. The mass of most of the molecules reaching the Faraday cup decreases with increasing frequency of rotation of the electric field in the cell. Therefore, the frequency of rotation of the electric field is made to vary in order to scan through a desired range of ion masses: For example, lightweight gas molecules are scanned at frequencies in the megahertz range, while DNA and other large organic molecules are scanned at kilohertz frequencies.

Hartley, Frank↗

Mapping Thermoelectric Transport in a Multicomponent Alloy Space

Abstract Interest in high entropy alloy thermoelectric materials is predicated on achieving ultralow lattice thermal conductivity κ L through large compositional disorder. However, here it is shown that for a given mechanism, such as mass contrast phonon scattering, κ L will be minimized along the binary alloy with highest mass contrast, such that adding an intermediate mass atom to increase atomic disorder can increase thermal conductivity. Only when each component adds an independent scattering mechanism (such as adding strain fluctuation to an existing mass fluctuation) is there a benefit. In addition, both charge carriers and heat‐carrying phonons are known to experience scattering due to alloying effects, leading to a trade‐off in thermoelectric performance. Analytic transport models are applied, based on perturbation and effective medium theories, to predict how alloy scattering will affect the thermal and electronic transport across the full compositional range of several pseudo‐ternary and pseudo‐quaternary alloy systems. To do so, a multicomponent extension is demonstrated to both thermal and electronic binary alloy scattering models based on the virtual crystal approximation. Finally, it is shown that common functional forms used in computational thermodynamics can be applied to this problem to further generalize the scattering behavior that is modeled.

36 MATERIALS SCIENCE↗

High-precision mass measurement of Si 24 and a refined determination of the r p process at the A = 22 waiting point

We report a high-precision mass measurement of 24 Si, performed with the Low Energy Beam and Ion Trap (LEBIT) facility at the National Superconducting Cyclotron Laboratory. The atomic mass excess, 10 753.8 (37) keV, is a factor of 5 more precise than previous results. This substantially reduces the uncertainty of the 23 Al(p ,γ) 24 Si reaction rate, which is a key part of the rapid proton capture (rp) process powering type I x-ray bursts. Furthermore, the updated rate constrains the onset temperature of the (α,p) process at the 22 Mg waiting point to a precision of 9%.

20 ≤ A ≤ 38↗

Smaller, Lighter Magnetic Sector For Mass Spectrometer

Miniature, lightweight focal-plane magnetic sector of mass spectrometer (Mattauch-Herzog type) developed. Magnetic sector integral part of portable gas-chromatograph/mass spectrometer (GC/MS). Focal plane covers nominal range of 40 to 240 atomic mass units for 1-keV ion energy. System used for analyzing pollutants in field environments.

Sinha, Mahadeva P.↗

An application of a space technique for pollution detection.

Description of the hazardous gas detection system (HGDS) used during Apollo-Saturn launch tests for identifying and analyzing extremely minute amounts of gases escaping during cryogenic loading. These gases included hydrogen, helium, nitrogen, oxygen, nitrogen tetroxide, and hydrazine N2H3 radical. The heart of the HGDS is a mass spectrometer operating under high vacuum and capable to measure both qualitatively and quantitatively the presence and percentage of any gas whose molecular weight is between 2 and 150 atomic mass units. It is suggested that such a system could be utilized to detect environmental pollutants.

Hall, J. J.↗

Athermal phonon collection efficiency in diamond crystals for low mass dark matter detection

Here, we explored the efficacy of lab-grown diamonds as potential target materials for the direct detection of sub-GeV dark matter (DM) using metallic magnetic calorimeters (MMCs). Diamond, with its excellent phononic properties and the low atomic mass of the constituent carbon, can play a crucial role in detecting low mass dark matter particles. The relatively long electron-hole pair lifetime inside the crystal may provide discrimination power between the DM-induced nuclear recoil events and the background-induced electron recoil events. Utilizing the fast response times of the MMCs and their unique geometric versatility, we deployed a novel methodology for quantifying phonon dynamics inside diamond crystals. We demonstrated that lab-grown diamond crystals fabricated via the chemical vapor deposition (CVD) technique can satisfy the stringent quality requirements for sub-GeV dark matter searches. The high-quality polycrystalline CVD diamond showed a superior athermal phonon collection efficiency compared to that of the reference sapphire crystal, and achieved energy resolution 62.7 eV at the 8.05 keV copper fluorescence line. With this energy resolution, we explored the low-energy range below 100 eV and confirmed the existence of so-called low-energy excess (LEE) reported by multiple cryogenic experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Chapter 13: Time-of-Flight Secondary-Ion Mass Spectrometry and Atom Probe Tomography

Time-of-flight secondary-ion mass spectrometry (TOF-SIMS) and atom probe tomography (APT) have many similarities. Both detect the chemical makeup of a solid material at ppm or better sensitivity, while retaining the spatial location information from the signal. Both use a similar principle to measure a signal associated with a given charged secondary ion—the flight time it takes a secondary ion to reach the detector after it is generated. Both are destructive techniques—albeit destructive of very small volumes—because the signal measured is generated by the removal of material from the sample itself. Importantly, both techniques require ultra-high vacuum (UHV) to ensure that the secondary ions, once generated, can reach the detector without collision with other atoms in the gas phase. In the case of TOF-SIMS, the samples can vary from several mm to several inches in size, whereas for APT, the samples are cones several hundred microns in size that are prepared in a special manner (covered in detail later in the chapter). We will discuss the basic fundamentals of each technique and cover several examples of the technique applied to photovoltaic materials, which should give a good idea of the types of information one can gain from TOF-SIMS and APT and how they are complementary as they both operate at different length scales: at the hundreds of microns to hundreds of nanometer scale for TOF-SIMS and at the nanometer to a few angstroms scale for APT.

41 EE - Solar Energy Technologies Office (EE-4S)↗

High-flux source of low-energy neutral beams using reflection of ions from metals

Reflection of low-energy ions from surfaces can be applied as a method of producing high-flux beams of low-energy neutral particles, and is an important effect in several areas of plasma technology, such as in the edge region of fusion devices. We have developed a beam source based on acceleration and reflection of ions from a magnetically confined coaxial RF plasma source. The beam provides a large enough flux to allow the energy distribution of the reflected neutrals to be measured despite the inefficiency of detection, by means of an electrostatic cylindrical mirror analyzer coupled with a quadrupole mass spectrometer. Energy distributions have been measured for oxygen, nitrogen, and inert gas ions incident with from 15 to 70 eV reflected from amorphous metal surfaces of several compositions. For ions of lighter atomic mass than the reflecting metal, reflected beams have peaked energy distributions; beams with the peak at 4-32 eV have been measured. The energy and mass dependences of the energy distributions as well as measurements of absolute flux, and angular distribution and divergence are reported. Applications of the neutral beams produced are described.

Cuthbertson, John W.↗

Correlation of materials properties with the atomic density concept

Based on the hypothesis that the number of atoms per unit volume, accurately calculable for any substance of known real density and chemical composition, various characterizing parameters (energy levels of electrons interacting among atoms of the same or different kinds, atomic mass, bond intensity) were chosen for study. A multiple exponential equation was derived to express the relationship. Various properties were examined, and correlated with the various parameters. Some of the properties considered were: (1) heat of atomization, (2) boiling point, (3) melting point, (4) shear elastic modulus of cubic crystals, (5) thermal conductivity, and (6) refractive index for transparent substances. The solid elements and alkali halides were the materials studied. It is concluded that the number of different properties can quantitively be described by a common group of parameters for the solid elements, and a wide variety of compounds.

Source record↗

Mass fractionation in hydrodynamic escape

In mass fractionation during the hydrodynamic escape of gases from an inner planet's atmosphere, the readier escape of light gases generates a linear or concave downward line in a plotting of the log of remaining inventory against atomic mass. Just as such an episode of hydrodynamic escape during Mars' early history could have led to the mass-dependent depletion of the noble gases that has been noted in the Martian atmosphere, in the event that the Martian atmosphere was initially hydrogen-rich, an early earth-history episode may have resulted in a mass-dependent fractionation of the xenon isotopes.

Hunten, Donald M.↗